Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 120
Filtrar
1.
Adv Radiat Oncol ; 9(10): 101590, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39314904

RESUMEN

Purpose: The clinically accepted planning target volume margin for radiation therapy to the paraortic nodal region in cervical cancer patients is 5 mm. However, the comprehensive alignment and variability from the pelvic bone to all lumbar vertebrae are undetermined. This study aims to quantify the residual setup errors between the pelvic bone and lumbar vertebrae and determine the optimal correction strategy for patients with cervical cancer. Materials and Methods: Fifteen patients underwent pretreatment mega-voltage computed tomography scans (375 total fractions). Residual setup errors and required margins for each lumbar vertebra were calculated based on registrations accounting for pelvic rotation and translation. Results: The systematic residual errors (1 SD) at L1, L2, L3, L4, and L5 using pelvic bone registration were 6.5, 4.9, 3.1, 1.5, and 0.6 mm in the anterior-posterior (AP) direction, 3.1, 2.3, 1.4, 0.6, and 0.3 mm in the right-left direction, and 2.7, 2.2, 1.7, 1.0, and 0.5 mm in the superior-inferior direction, respectively. The residual setup errors were the largest in the AP direction. Registration based on the pelvic bone required margins in the AP direction of 16.0, 12.1, 7.7, 3.6, and 1.3 mm for L1, L2, L3, L4, and L5, respectively, whereas registration based on L3 required margins of 8.8, 4.8, 4.4, 7.1, and 7.7 mm for L1, L2, L4, L5, and pelvic bone, respectively. Conclusions: Considerable local setup variability was found in patients with cervical cancer. After reviewing the corrective strategies, we determined that L3-based registration effectively minimized the required margins.

2.
J Appl Clin Med Phys ; 25(9): e14413, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38923786

RESUMEN

PURPOSE: This study aimed to find descriptors that correlates with normal brain dose to determine the feasibility of performing fractionated stereotactic radiosurgery (SRS) for multiple brain metastases (BMs) using five linac machines. METHODS: Thirty-two patients with 1-30 BMs were enrolled. Treatment plans were created using TrueBeam, Novalis Tx, TrueBeam Edge, Halcyon, and Tomotherapy linacs. The sum of all planning target volumes (PTVs) was defined as PTVall, and the brain region excluding PTVall was defined as normal brain. The total surface area (TSA) of the PTV was calculated from the sum of the surface areas of the equivalent spheres for each PTV. Volumes receiving more than 5, 12, and 18 Gy (V5Gy, V12Gy, and V18Gy, respectively) were used for evaluation of normal brain dose. Correlations between normal brain dose and each tumor characteristic (number, PTVall, and TSA) were investigated using the Spearman rank correlation coefficient. RESULTS: Correlations between each characteristic and normal brain dose were statistically significant (p < 0.05) across all machines. The correlation coefficients between each characteristic and V18Gy for the five machines were as follows: tumor number, 0.39-0.60; PTVall, 0.79-0.93; TSA, 0.93-0.99. The fit equations between TSA and V18Gy exhibited high coefficients of determination, ranging from 0.92 to 0.99 across five machines. CONCLUSION: This study devised fractionated SRS plans using for 1-30 BMs across five linac machines to find descriptors for determining SRS feasibility based on normal brain dose. TSA proved to be a promising descriptor of SRS feasibility for treating multiple BMs.


Asunto(s)
Neoplasias Encefálicas , Estudios de Factibilidad , Aceleradores de Partículas , Radiocirugia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Humanos , Neoplasias Encefálicas/secundario , Neoplasias Encefálicas/cirugía , Neoplasias Encefálicas/radioterapia , Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Aceleradores de Partículas/instrumentación , Radioterapia de Intensidad Modulada/métodos , Órganos en Riesgo/efectos de la radiación , Pronóstico , Masculino , Femenino
3.
Cureus ; 16(4): e57415, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38694646

RESUMEN

Radiation therapy with X-rays for skin cancer uses a bolus to increase the surface dose. Commercial gel sheet boluses adhere poorly to the patient's body because of surface irregularities. This causes an air gap and reduces the surface dose. We have developed a novel shapeable bolus (HM bolus; Hayakawa Rubber Co., Ltd., Hiroshima, Japan), and we describe the first clinical application of this bolus here. The case was an 82-year-old male with a facial cutaneous squamous cell carcinoma. The postoperative radiotherapy plan using the HM bolus provided a more uniform dose to the target compared with a plan without the HM bolus. The HM bolus adhered stably to the patient's skin, and there were no issues with its clinical use.

4.
J Radiat Res ; 65(2): 223-230, 2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38264828

RESUMEN

The present study aimed to evaluate whether an adapted plan with Ethos™ could be used for pharyngeal cancer. Ten patients with pharyngeal cancer who underwent chemoradiotherapy with available daily cone-beam computed tomography (CBCT) data were included. Simulated treatments were generated on the Ethos™ treatment emulator using CBCTs every four to five fractions for two plans: adapted and scheduled. The simulated treatments were divided into three groups: early (first-second week), middle (third-fourth week), and late (fifth-seventh week) periods. Dose-volume histogram parameters were compared for each period between the adapted and scheduled plans in terms of the planning target volume (PTV) (D98%, D95%, D50% and D2%), spinal cord (Dmax and D1cc), brainstem (Dmax) and ipsilateral and contralateral parotid glands (Dmedian and Dmean). The PTV D98%, D95% and D2% of the adapted plan were significantly higher than those of the scheduled plans in all periods, except for D98% in the late period. The adapted plan significantly reduced the spinal cord Dmax and D1cc compared with the scheduled plan in all periods. Ipsilateral and contralateral parotid glands Dmean of the adapted plan were lower than those of scheduled plan in the late period. In conclusion, the present study revealed that the adapted plans could maintain PTV coverage while reducing the doses to organs at risk in each period compared with scheduled plans.


Asunto(s)
Neoplasias Faríngeas , Radioterapia de Intensidad Modulada , Humanos , Radioterapia de Intensidad Modulada/métodos , Órganos en Riesgo , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Tomografía Computarizada de Haz Cónico
5.
Cureus ; 15(10): e46805, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37954761

RESUMEN

BACKGROUND: To compare the doses calculated by the analytical anisotropic algorithm (AAA) and two dose reporting modes of Acuros XB (AXB(Dm) and AXB(Dw)) with varied CT values on the Eclipse (Varian Medical Systems, Palo Alto, CA). MATERIALS AND METHODS: Virtual phantoms with a central layer of heterogeneous material (thickness = 2 or 5 cm) were created with Eclipse. Using single or opposed fields, the field sizes were 5 x 5 cm2 or 10 x 10 cm2. The photon energies were 6 or 10 MV, and the source-to-target distance was 100 cm. The relative doses at the center of the heterogeneous material layer were evaluated with varied CT values, from -1000 to 3000 HU. Values were normalized with the dose at 0 HU (100%) for comparative analysis. RESULTS: The results obtained from continuous data for a single field, 6 MV, 5 x 5 cm2, and the heterogeneous material 5 cm, where the differences between algorithms were most pronounced, were as follows. In the low-density region (-1000 HU and -800 HU), the dose differences for AXB with reference to AAA were, respectively, -54.5% and +4.6% (AXB(Dm)) and -47.0% and +3.5% (AXB(Dw)), and in the high-density regions (1000 HU and 3000 HU) were -5.7% and -8.8% (AXB(Dm)) and +7.4% and +3.5% (AXB(Dw)), respectively. Consequently, dose differences at arbitrary CT values could be obtained. CONCLUSION: Dose differences between these algorithms were clarified for heterogeneous materials. The risk of dose reduction or escalation in clinical use was clearly visible between CT values from -1000 to 3000 HU.

6.
Radiol Phys Technol ; 16(4): 543-551, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37839000

RESUMEN

Skin marks are widely used in external radiation therapy to ensure the accuracy of the irradiation position. However, conventional skin markers contain harmful substance, so we developed an alternative skin marker. The purpose of this study was to investigate the feasibility of using a novel water-based pigment marker comprising safe materials commonly used in cosmetics for clinical radiation therapy. We investigated various properties of the marker, namely marker longevity, color variety, line visibility, ink bleeding, and line durability, and improved the marker in response to the feel when drawing or being drawn on. The durability of the ink was evaluated by simultaneously applying the new marker and oil-based pen and comparing the period until the marks faded and became invisible. In clinical trial, we applied marks on the skin of 56 patients over three months to observe symptoms and visible changes in the skin. There were no complications of discomfort or pain, owing to the improvements in the marker tip. The marks drawn on the arms of volunteers with the new marker and the oil-based pen remained visible for a mean of 7.2 days and 3.6 days, respectively (P value < 0.001). The percentages of participants with no symptoms and no visible changes were 100%, respectively. We developed an alternative skin marker that complies with current regulatory standards by excluding crystal violet. The newly developed marker has features suitable for clinical use, such as resistance to smudging and water, marker tip shape and texture, and color variations.


Asunto(s)
Violeta de Genciana , Piel , Humanos , Estándares de Referencia
7.
Rep Pract Oncol Radiother ; 28(3): 399-406, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37795404

RESUMEN

Background: We clarified the dose difference between the anisotropic analytical algorithm (AAA) and Acuros XB (AXB) with increasing target's air content using a virtual phantom and clinical cases. Materials and methods: Whole neck volumetric modulated arc therapy (VMAT) plan was transferred into a virtual phantom with a cylindrical air structure at the center. The diameter of the air structure was changed from 0 to 6 cm, and the target's air content defined as the air/planning target volume (PTV) in percent (air/PTV) was varied. VMAT plans were recalculated by AAA and AXB with the same monitor unit (MU) and multi-leaf collimator (MLC) motions. The dose at each air/PTV (5%-30%) was compared between each algorithm with D98%, D95%, D50% and D2% for the PTV. In addition, MUs were also compared with the same MLC motions between the D95% prescription with AAA (AAA_D95%), AXB_D95%, and the prescription to 100% minus air/PTV (AXB_D100%-air/PTV) in clinical cases of head and neck (HNC). Results: When air/PTV increased (5-30%), the dose differences between AAA and AXB for D98%, D95%, D50% and D2% were 3.08-15.72%, 2.35-13.92%, 0.63-4.59%, and 0.14-6.44%, respectively. At clinical cases with air/PTV of 5.61% and 28.19%, compared to AAA_D95%, the MUs differences were, respectively, 2.03% and 6.74% for AXB_D95% and 1.80% and 0.50% for AXB_D100%-air/PTV. Conclusion: The dose difference between AAA and AXB increased as the target's air content increased, and AXB_D95% resulted in a dose escalation over AAA_D95% when the target's air content was ≥ 5%. The D100%-air/PTV of PTV using AXB was comparable to the D95% of PTV using AAA.

8.
J Med Phys ; 48(2): 189-194, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37576099

RESUMEN

Aims: We investigated imaging dose and noise under clinical scan conditions at multiple institutions using a simple and unified method, and demonstrated the need for diagnostic reference levels in image-guided radiotherapy (IGRT). Materials and Methods: Nine cone-beam and helical computed tomography (CT) scanners (Varian, Elekta, Accuray Inc., and BrainLAB) from seven institutions were investigated in this study. The weighted cone-beam dose index (CBDIw) was calculated for head and pelvic protocols using a 100 mm pencil chamber under the conditions used in actual clinical practice at each institution. Cone-beam CT image noise was evaluated using polymethylmethacrylate head and body phantoms with diameters of 16 and 32 cm, respectively. Results: For head and pelvic protocols, CBDIw values ranged from 0.94-6.59 and 1.47-20.9 mGy, respectively. Similarly, standard deviation (SD) values ranged from 9.3-34.0 and 26.9-97.4 HU, respectively. The SD values tended to increase with decreasing imaging dose (r = -0.33 and -0.61 for the head and pelvic protocols, respectively). Conclusions: Among the nine machines, the imaging dose for high imaging dose institutions was approximately 20 mGy to the pelvic phantom, and there was a 14-fold difference in dose compared with the other institutions. These results suggest the need to establish DRLs for IGRT to guide clinical decision-making.

9.
Ann Nucl Med ; 37(11): 629-634, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37596439

RESUMEN

OBJECTIVE: The purpose of this study is to determine the dose reduction of different shielding materials at various distances from a 177Lu photon radiation source. METHODS: Two protective aprons with lead equivalent thicknesses of 0.25 mm and 0.35 mm and tungsten-containing rubber (TCR) were used as shielding materials. A vial containing 177Lu was sealed in a lead container so that a narrow beam went out through a 3 mm-diameter hole. The dose rate was measured at distances of 0, 10, 50, 100, and 200 cm from the source using a NaI scintillation survey meter to obtain the rate of dose reduction. TCR was tested with thicknesses ranging from 0.3 to 1.0 mm at 0.1 mm intervals and from 1.0 to 4.0 mm at 0.5 mm intervals. RESULTS: At distances of 0, 10, 50, 100, and 200 cm, the dose reduction for the lead equivalent thickness of 0.25 mm were 32.7%, 54.5%, 93.1%, 97.9%, and 99.6%, respectively; and for the lead equivalent thickness of 0.35 mm were 53.4%, 70.6%, 95.6%, 98.9%, and 99.6%, respectively. Without any shielding, the dose rate decreased by 34.4% at 10 cm and by 88.8% at 50 cm from the radiation source. The dose reduction for the TCR thickness of 3.5 mm was 89.8% at 0 cm and 93.3% at 10 cm. The TCR thickness of 0.4 mm provided a dose reduction comparable to or greater than that of the 0.25 mm lead equivalent, whereas the TCR thickness of 1.0 mm or greater provided a dose reduction comparable to that of the 0.35 mm lead equivalent. CONCLUSIONS: Achieving a reduction of 95% or more requires the 0.25 mm lead equivalent for a distance of 100 cm, the 0.35 mm lead equivalent for 50 cm, the TCR thickness of 0.3 mm for 100 cm, or the TCR thickness of 0.9 mm for 50 cm. Without wearing a protective apron, a reduction of approximately 95% is observed at distances greater than 100 cm. These findings would be useful for medical staff engaging in related activities.

10.
Phys Eng Sci Med ; 46(3): 1091-1100, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37247102

RESUMEN

PURPOSE: To evaluate whether knowledge-based volumetric modulated arc therapy plans for prostate cancer with a multi-institution model (broad model) are clinically useful and effective as a standardization method. METHODS: A knowledge-based planning (KBP) model was trained with 561 prostate VMAT plans from five institutions with different contouring and planning policies. Five clinical plans at each institution were reoptimized with the broad and single institution model, and the dosimetric parameters and relationship between Dmean and the overlapping volume (rectum or bladder and target) were compared. RESULTS: The differences between the broad and single institution models in the dosimetric parameters for V50, V80, V90, and Dmean were: rectum; 9.5% ± 10.3%, 3.3% ± 1.5%, 1.7% ± 1.6%, and 3.6% ± 3.6%, (p < 0.001), bladder; 8.7% ± 12.8%, 1.5% ± 2.6%, 0.7% ± 2.4%, and 2.7% ± 4.6% (p < 0.02), respectively. The differences between the broad model and clinical plans were: rectum; 2.4% ± 4.6%, 1.7% ± 1.7%, 0.7% ± 2.4%, and 1.5% ± 2.0%, (p = 0.004, 0.015, 0.112, and 0.009) bladder; 2.9% ± 5.8%, 1.6% ± 1.9%, 0.9% ± 1.7%, and 1.1% ± 4.8%, (p < 0.018), respectively. Positive values indicate that the broad model has a lower value. Strong correlations were observed (p < 0.001) in the relationship between Dmean and the rectal and bladder volume overlapping with the target in the broad model (R = 0.815 and 0.891, respectively). The broad model had the smallest R2 of the three plans. CONCLUSIONS: KBP with the broad model is clinically effective and applicable as a standardization method at multiple institutions.


Asunto(s)
Neoplasias de la Próstata , Radioterapia de Intensidad Modulada , Masculino , Humanos , Próstata , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Estándares de Referencia
11.
Anticancer Res ; 43(5): 1967-1972, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37097686

RESUMEN

BACKGROUND/AIM: This study compared two types of parallel-plate ionization chamber to clarify the pitfalls of dosimetry in electron radiation therapy. MATERIALS AND METHODS: The ion recombination correction factor and polarity effect correction factor, sensitivity, and percentage depth doses (PDDs) of PPC05 and PPC40 parallel-plate ionization chambers were compared in a small-field electron beam. The output ratios were measured for 4-20 MeV electron beams with field sizes of 10 cm × 10 cm, 6 cm × 6 cm, and 4 cm × 4 cm. Furthermore, the films were placed in water and positioned in the beam with their surface perpendicular to the beam axis, and lateral profiles were obtained for each beam energy and each field. RESULTS: Regarding PDDs, at depths greater than the peak dose, the percentage depth dose for PPC40 was smaller than that for PPC05 in small fields and at beam energies greater than 12 MeV, which could be attributed to the lack of lateral electron equilibrium at small depths and multiple scattering events at large depths. The output ratio of PPC40 was approximately 0.025-0.038, which was lower than that of PPC05 in a 4 cm × 4 cm field. For large fields, the lateral profiles were similar, regardless of the beam energy, however, for small fields, the flatness of the lateral profile was beam energy dependent. CONCLUSION: The PPC05 chamber, which has a smaller ionization volume, is therefore more suitable than the PPC40 chamber for small-field electron dosimetry, in particular at high beam energies.


Asunto(s)
Electrones , Radiometría , Humanos , Agua
12.
Med Dosim ; 48(3): 193-196, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37080819

RESUMEN

We performed daily cone-beam computed tomography (CBCT) to determine the impact of rectal gas on the movements of prostate and seminal vesicles (SVs). We aimed to determine the relationship between planning target volume (PTV) margins and rectal gas. In 30 treatments of 15 prostate cancer patients, excessive rectal gas was removed and CBCT images were analyzed. Image registration between planning CT and daily CBCT images before and after rectal gas removal was performed for pelvic bone and prostate matching. The couch movement distance between each matching was considered the prostate movement. In addition, we measured SV tip movement between each matching. The anterior-posterior movement of the prostate before rectal gas removal (3.1 ± 2.9 mm) was significantly greater than that after rectal gas removal (1.2 ± 1.2 mm; p < 0.01). The left-right and superior-inferior movements were similar regardless of the presence or absence of rectal gas. The SV movement distances before and after rectal gas removal were 11.0 ± 5.8 mm and 4.6 ± 3.8 mm, respectively (p < 0.01), in pelvic bone matching, and 8.0 ± 4.2 mm and 3.8 ± 3.2 mm, respectively (p < 0.01), in prostate matching. After rectal gas removal, the SV position did not differ significantly between each matching. In 26 of the 30 treatments, SV movement distance in the presence of rectal gas was >6 mm, which is the minimum PTV margin at our institution. In comparison, after rectal gas removal and prostate matching, only 6 treatments demonstrated an SV movement distance of >6 mm. In the presence of rectal gas, the SVs require greater PTV margins than the prostate. Rectal gas removal should be considered if the movement distance on prostate matching is greater than the minimum PTV margin at treating institution.

13.
Cureus ; 15(3): e36493, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37090359

RESUMEN

This study aims to determine the feasibility of using a new O-ring linear accelerator (Halcyon, Varian Medical Systems, CA, USA) to perform treatment planning using volumetric modulated arc therapy (VMAT) for craniospinal irradiation (CSI). A 20-year-old male patient with leukemia was selected. The planning target volume (PTV) was contoured to include the entire contents of the brain and spinal canal. The PTV margin was 10 mm applied to the clinical target volume (CTV). VMAT (RapidArc, Varian Medical Systems, CA, USA) planning was performed using four isocenter with five arcs, two full rotation arcs to cover the brain and upper part of the spinal cord, and one full rotation arc for the lower part of the spinal cord. The plan was created using the auto-feathering photon optimizer calculation of the planning system. The conformity index (CI) and heterogeneity index (HI) as well as dose-volume histograms of organs at risk (OAR) were evaluated. The patient position of ±3.0 mm in the craniocaudal direction was moved in to simulate the effect of treatment inaccuracy. The total treatment time was also measured. The CI and HI were 1.09 and 8.44, respectively. The mean dose (PTV) was 105.5%, and the mean dose (OARs) was lower than the planning dose constraints. Simulations with a patient position shift of ±3.0 mm resulted in an error of less than ±10.0% of the planned dose to the spinal cord. The total treatment time was within 15 minutes. VMAT planning for CSI with Halcyon achieved high conformality, uniform dose distribution, low dose to the surrounding normal tissues, and reduced treatment time.

14.
Phys Med Biol ; 68(10)2023 05 05.
Artículo en Inglés | MEDLINE | ID: mdl-36972591

RESUMEN

Objective.The purpose of this study was to develop a new bolus (HM bolus), with tissue equivalence, transparency, reusability, and free shaping at approximately 40 °C for excellent adhesion, and to evaluate the feasibility of clinically using this bolus as an ideal bolus.Approach.We summarized the advantages and disadvantages of existing boluses. To evaluate dose characteristics, a vinyl gel sheet bolus (Gel bolus) and HM bolus placed on a water-equivalent phantom were used to obtain the percentage depth dose (PDD) of electron (6 MeV, 9 MeV) and photon (4 MV, 6 MV) beams. The average dose difference of the HM bolus and Gel bolus was calculated. The Gel bolus, a soft rubber bolus (SR bolus), and HM bolus were placed in adherence to a pelvic phantom. CT images taken after shaping and 1, 2, and 3 weeks after shaping were used to evaluate the adhesion and reproducibility using air gap and dice similarity coefficient (DSC).Main results.The average dose difference for electron beams was 0.16% ± 0.79% and photon beams was 0.06% ± 0.34%, both within 1% of the PDD results. The HM bolus showed the same build-up effect and dose characteristics as the Gel bolus. The mean air gap values for the Gel bolus, SR bolus, and HM bolus were 96.02 ± 43.77 cm3, 34.93 ± 21.44 cm3, and 4.40 ± 1.50 cm3, respectively. The mean DSC values compared to initial images for the Gel bolus, SR bolus, and HM bolus were 0.363 ± 0.035, 0.556 ± 0.042, and 0.837 ± 0.018, respectively. Excellent adhesion was observed in the CT simulation and during the treatment period.Significance.The HM bolus has unique features, such as tissue equivalence, transparency, reusability, and free shaping for excellent adhesion, and is thus an ideal bolus for use in clinical cases.


Asunto(s)
Fotones , Planificación de la Radioterapia Asistida por Computador , Reproducibilidad de los Resultados , Método de Montecarlo , Planificación de la Radioterapia Asistida por Computador/métodos , Simulación por Computador , Fantasmas de Imagen , Dosificación Radioterapéutica , Radiometría/métodos , Radioterapia
15.
Cureus ; 15(1): e34287, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36843808

RESUMEN

Background Coronavirus disease 2019 and other viruses are transmissible by aerosols and droplets from infected persons. This study aimed to develop a portable device that can trap droplets and deactivate viruses, and verify whether the device in an enclosed room can suction droplets and sanitize them using a filter and an ultraviolet-C (UVC) light-emitting diode. Materials and methods The portable device was evaluated by placing it 50 cm away from the droplet initiation point. A particle image velocimetry laser dispersed into a sheet form was used to visualize the droplets splashed on the irradiated sagittal plane and captured using a charge-coupled device camera at 60 frames per second. The images were overlaid and calculated to determine the percentage of the droplets beyond the portable device. Droplets with a particle size larger than 50 µm that dispersed and were deposited more than 100 cm away were measured using a water-sensitive paper. The effect of UVC sanitization on viruses captured by a high-efficiency particulate air (HEPA) filter was determined using a plaque assay. Results The percentage of droplets was 13.4% and 1.1% with the portable device OFF and ON, respectively, indicating a 91.8% reduction. The deposited droplets were 86 pixels and 26 pixels with the portable device OFF and ON, respectively, indicating a 68.7% reduction. The UVC deactivated more than 99% of the viruses on the HEPA filter surface in 5 minutes. Conclusions Our novel portable device can suck and fall the dispersed droplets, and an active virus was not observed on the exhaust side.

16.
Radiat Prot Dosimetry ; 199(4): 366-372, 2023 Mar 17.
Artículo en Inglés | MEDLINE | ID: mdl-36617526

RESUMEN

This study aims to measure the shielding effect of a novel tungsten rubber sheet (TRS) on the exposure of male gonads to ionizing radiation during upper abdominal and abdominal plus pelvic computed tomography (CT) examinations. The air kerma at the gonad with and without shielding was measured using an anthropomorphic body phantom. Gonads were shielded using: (1) 360° wrap with TRS (0.5-mm thick) and (2) 180° wrap with TRS. The air kerma at a position of male gonads in a pelvic scan was 21.8 mGy, even when the gonads were in the off-axis range. The TRS reduced the dose to the male gonads in abdominal plus pelvic CT examinations by 61% and 38% for the 360° and 180° TRS wrap, respectively.


Asunto(s)
Tomografía Computarizada por Rayos X , Tungsteno , Masculino , Humanos , Adolescente , Adulto Joven , Dosis de Radiación , Gónadas , Radiación Ionizante , Fantasmas de Imagen
17.
Phys Eng Sci Med ; 46(1): 179-184, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36484890

RESUMEN

To clarify the dosimetric characteristics of a real-time variable shape rubber-containing tungsten (STR) bolus in a clinical plan and investigate the efficacy of the STR bolus in photon radiotherapy for keloids and other superficial tumors. A 5 mm gel bolus or 1 mm STR bolus was placed on a solid water phantom. Tangential irradiation was performed using a TomoTherapy Radixact-X9 and 6 MV X-ray flattening-filter-free beam, and the surface dose was measured with radiochromic film. Clinical-like plans (TomoDirect; TD and TomoHelical; TH) were applied with the same geometry and the dose distributions were measured. The increase in surface dose by the build-up effect and backscatter was 37.7% and 8.0% for the gel bolus, and 40.5% and 26.4% for the STR bolus, respectively. In the TD and TH plans, the increase in surface dose was 27.4% and 48.3% for the gel bolus, and 39.0% and 63.2% for the STR bolus. Similary, changes in the sagittal plane dose were - 3.9% and 6.1% for the gel bolus, and - 6.3% and 6.9% for the STR bolus. The STR bolus effectively increased the surface dose by the build-up effect and backscatter in photon radiotherapy for keloids and other superficial tumors.


Asunto(s)
Queloide , Neoplasias , Humanos , Queloide/diagnóstico por imagen , Queloide/radioterapia , Goma , Tungsteno , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador
18.
J Appl Clin Med Phys ; 24(2): e13836, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36333969

RESUMEN

OBJECTIVE: Dosimetric potential of knowledge-based RapidPlan planning model trained with HyperArc plans (Model-HA) for brain metastases has not been reported. We developed a Model-HA and compared its performance with that of clinical volumetric modulated arc therapy (VMAT) plans. METHODS: From 67 clinical stereotactic radiosurgery (SRS) HyperArc plans for brain metastases, 47 plans were used to build and train a Model-HA. The other 20 clinical HyperArc plans were recalculated in RapidPlan system with Model-HA. The model performance was validated with the 20 plans by comparing dosimetric parameters for normal brain tissue between clinical plans and model-generated plans. The 20 clinical conventional VMAT-based SRS or stereotactic radiotherapy plans (CL-VMAT) were reoptimized with Model-HA (RP) and HyperArc system (HA), respectively. The dosimetric parameters were compared among three plans (CL-VMAT vs. RP vs. HA) in terms of planning target volume (PTV), normal brain excluding PTVs (Brain - PTV), brainstem, chiasm, and both optic nerves. RESULTS: In model validation, the optimization performance of Model-HA was comparable to that of HyperArc system. In comparison to CL-VMAT, there were no significant differences among three plans with respect to PTV coverage (p > 0.17) and maximum dose for brainstem, chiasm, and optic nerves (p > 0.40). RP provided significantly lower V20 Gy , V12 Gy , and V4 Gy for Brain - PTV than CL-VMAT (p < 0.01). CONCLUSION: The Model-HA has the potential to significantly reduce the normal brain dose of the original VMAT plans for brain metastases.


Asunto(s)
Neoplasias Encefálicas , Radiocirugia , Radioterapia de Intensidad Modulada , Humanos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/cirugía , Neoplasias Encefálicas/secundario , Encéfalo , Radiocirugia/métodos , Radioterapia de Intensidad Modulada/métodos
19.
J Appl Clin Med Phys ; 24(1): e13807, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36265085

RESUMEN

Independent monitor unit verification (MUV) methods for the dynamic beam-flattening (DBF) technique have not been established. The purpose of this study was to clarify whether MU values for the DBF technique can be calculated using in-air and in-water output ratios (Sc and Scp ). Sc and Scp were measured in the DBF mode, and the phantom scatter factor (Sp ) was calculated. The difference between calculated and planned MUs with square and rectangle fields and clinical plans for different treatment sites was also evaluated. Sc values for the 4 × 4 to 24 × 24 cm2 fields of the distal multi-leaf collimator (MLC) layer at 2-cm intervals were 0.887, 0.815, 0.715, 0.716, 0.611, 0.612, 0.511, 0.373, 0.374, 0.375, and 0.374, respectively. No collimator exchange effect was observed. Sc also depends slightly on the field size of the distal MLC layer. If the distal-MLC-layered field size was less than 20% of the corresponding MLC sequence size in the proximal MLC layer, Sc was affected by >1%, which was compensated using a correction factor (CF). Sp increased as the field sizes of the MLC sequence and distal MLC leaves increased. MUs calculated using measured Sc , Sp , and CF for square and rectangle fields agreed with planned MUs within ±1.2%. A larger difference (-1.5%) between calculated and planned MUs was observed for clinical plans, whereas differences in MUs were within 2 MU for most fields (56 out of 64 fields). MU calculation for the DBF technique can be performed with Sc , Sp , and CF for independent MUV.


Asunto(s)
Aceleradores de Partículas , Planificación de la Radioterapia Asistida por Computador , Humanos , Fantasmas de Imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Dosificación Radioterapéutica , Radiometría
20.
J Med Phys ; 48(4): 365-372, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38223796

RESUMEN

Purpose: The purpose of the study is to investigate the impact of large target offset distances on the dose distribution and gamma passing rate (GPR) in single-isocenter multiple-target stereotactic radiosurgery (SIMT SRS) using volumetric modulated arc therapy (VMAT) with a flattening filter-free (FFF) beam from a linear accelerator. Methods: Two targets with a diameter of 1 cm were offset by "±2, ±4, and ±6 cm from the isocenter in a verification phantom for head SRS (20 Gy/fr). The VMAT plans were created using collimator angles that ensured the two targets did not share a leaf pair from the multi-leaf collimator. To evaluate the low-dose spread intermediate dose spill (R50%), GPRs were measured with a criterion of 3%/2 mm using an electronic portal imaging device and evaluated using monitor unit (MU), modulation complexity score for VMAT (MCSv), and leaf travel (LT) parameters. Results: For offsets of 2, 4, and 6 cm, the respective parameters were: R50%, 4.75 ± 0.36, 5.13 ± 0.36, and 5.11 ± 0.33; GPR, 95.01%, 93.82%, and 90.67%; MU, 5893 ± 186, 5825 ± 286, and 5810 ± 396; MCSv, 0.24, 0.16, and 0.13; and LT, 189.21 ± 36.04, 327.69 ± 67.01, and 430.39 ± 114.34 mm. There was a spread in the low-dose region from offsets of ≥4 cm and the GPR negatively correlated with LT (r = -0.762). There was minimal correlation between GPR and MU or MCSv. Conclusions: In SIMT SRS VMAT plans with an FFF beam from a linear accelerator, target offsets of <4 cm from the isocenter can minimize the volume of the low-dose region receiving 10 Gy or more. During treatment planning, it is important to choose gantry, couch, and collimator angles that minimize LT and thereby improve the GPR.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA