Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 120
Filtrar
1.
Heart Lung Circ ; 2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-38942621

RESUMEN

BACKGROUND: The impact of sex on outcomes following surgical aortic valve replacement (SAVR) remains unclear. It has been proposed that females experience inferior outcomes, but this has yet to be conclusively established, particularly in the long term. The objective of this study is to identify discrepancies in postoperative outcomes between males and females following SAVR to better inform consideration for surgical intervention. METHOD: We retrospectively reviewed the outcomes of 4,927 patients who underwent SAVR from 2004 to 2018 at our centre. In total, 531 propensity-matched males and females were included in the final analysis. The primary outcome was mortality at any point during the follow-up period. Secondary outcomes included various measures of postoperative morbidity. Follow-up duration was 15 years. RESULTS: In SAVR all-comers, females experienced inferior short-term mortality, but equivalent mid-term and long-term mortality. Rates of mediastinal bleeding, sternal wound infections, sepsis, heart failure, and pacemaker insertion were all equivalent between the sexes; however, males experienced a higher rate of acute kidney injury and readmission for stroke at the longest follow-up while females experienced a longer intensive care unit and hospital length of stay. In a sub-analysis of isolated SAVR, males and females experienced equivalent early, mid, and late mortality. Of note, a trend towards increased aortic valve reoperation was noted in females at the longest follow-up. CONCLUSIONS: Males and females experience equivalent long-term mortality following isolated SAVR. Sex is not an independent risk factor of poor outcomes post-SAVR; however, the increased preoperative risk profile of females requires diligent consideration.

2.
J Clin Med ; 13(9)2024 Apr 28.
Artículo en Inglés | MEDLINE | ID: mdl-38731123

RESUMEN

The treatment of DeBakey type I aortic dissection remains a major challenge in the field of aortic surgery. To upgrade the standard of care hemiarch replacement, a novel device called an "Ascyrus Medical Dissection Stent" (AMDS) is now available. This hybrid device composed of a proximal polytetrafluoroethylene cuff and a distal non-covered nitinol stent is inserted into the aortic arch and the descending thoracic aorta during hypothermic circulatory arrest in addition to hemiarch replacement. Due to its specific design, it may result in a reduced risk for distal anastomotic new entries, the effective restoration of branch vessel malperfusion and positive aortic remodeling. In this narrative review, we provide an overview about the indications and the technical use of the AMDS. Additionally, we summarize the current available literature and discuss potential pitfalls in the application of the AMDS regarding device failure and aortic re-intervention.

3.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38759115

RESUMEN

OBJECTIVES: The Dissected Aorta Repair Through Stent (DARTS) Implantation trial demonstrated positive proximal aortic remodelling following aortic dissection repair with the AMDS hybrid prosthesis. In this study, we look to identify predictors of aortic remodelling following aortic dissection repair with AMDS including whether communications between branch vessels and the false lumen (FL) predict aortic growth. METHODS: The DARTS implantation trial included patients who underwent acute DeBakey type I aortic dissection (ATAD I) repair with the AMDS from March 2017 to January 2019. Anatomic measurements were collected from original computerized tomography scans. Measurements were taken at zones 2, 3, 6 and 9. Patients were grouped based on the number of FL communications with the supra-aortic branch vessels or visceral branch vessels. RESULTS: Forty-seven patients were included in the original DARTS implantation trial. Patients with FL communications with the supra-aortic branch vessels tended to have significant growth at zone 3 (P = 0.02-0.0018), while greater numbers of visceral FL communications tended to predict aortic growth at zones 3 (P = 0.003), 6 (P = 0.017-0.0087) and 9 (P = 0.0016-0.0003). CONCLUSIONS: Aortic remodelling following ATAD I repair using the AMDS may be predicted by local FL communications with branch vessels. Patients undergoing ATAD I repair were more likely to experience significant aortic growth in zone 3 with more head vessel communications and in zones 3, 6 and 9 with more visceral FL communications. Predictors of aortic remodelling may help to guide initial surgical management for aortic dissection patients.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Stents , Remodelación Vascular , Humanos , Disección Aórtica/cirugía , Masculino , Femenino , Persona de Mediana Edad , Remodelación Vascular/fisiología , Implantación de Prótesis Vascular/métodos , Aneurisma de la Aorta Torácica/cirugía , Prótesis Vascular , Anciano , Procedimientos Endovasculares/métodos , Diseño de Prótesis , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
4.
CJC Open ; 6(4): 628-631, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38708052
5.
Neurophotonics ; 11(2): 024207, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38577628

RESUMEN

Significance: Genetically encoded calcium ion (Ca2+) indicators (GECIs) are powerful tools for monitoring intracellular Ca2+ concentration changes in living cells and model organisms. In particular, GECIs have found particular utility for monitoring the transient increase of Ca2+ concentration that is associated with the neuronal action potential. However, the palette of highly optimized GECIs for imaging of neuronal activity remains relatively limited. Expanding the selection of available GECIs to include new colors and distinct photophysical properties could create new opportunities for in vitro and in vivo fluorescence imaging of neuronal activity. In particular, blue-shifted variants of GECIs are expected to have enhanced two-photon brightness, which would facilitate multiphoton microscopy. Aim: We describe the development and applications of T-GECO1-a high-performance blue-shifted GECI based on the Clavularia sp.-derived mTFP1. Approach: We use protein engineering and extensive directed evolution to develop T-GECO1. We characterize the purified protein and assess its performance in vitro using one-photon excitation in cultured rat hippocampal neurons, in vivo using one-photon excitation fiber photometry in mice, and ex vivo using two-photon Ca2+ imaging in hippocampal slices. Results: The Ca2+-bound state of T-GECO1 has an excitation peak maximum of 468 nm, an emission peak maximum of 500 nm, an extinction coefficient of 49,300 M-1 cm-1, a quantum yield of 0.83, and two-photon brightness approximately double that of EGFP. The Ca2+-dependent fluorescence increase is 15-fold, and the apparent Kd for Ca2+ is 82 nM. With two-photon excitation conditions at 850 nm, T-GECO1 consistently enabled the detection of action potentials with higher signal-to-noise (SNR) than a late generation GCaMP variant. Conclusions: T-GECO1 is a high-performance blue-shifted GECI that, under two-photon excitation conditions, provides advantages relative to late generation GCaMP variants.

6.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38598445

RESUMEN

OBJECTIVES: The indications for use, evidence base and experience with the novel noncovered open hybrid surgical stents for acute type A aortic dissection repair for concurrent stabilization of the 'downstream' aorta remains limited. We review the evidence base and the development of these stents. METHODS: Data were collected from Pubmed/Medline literature search to develop and review the evidence base for safety and efficacy of non-covered surgical stents. Existing guidelines for use and developments were reviewed. RESULTS: A single randomized control trial and 4 single-centre studies were included in the review with a total worldwide experience of 241 patients. The deployment was easy and did not add significantly to the primary operation. The mortality and new stroke ranged from 6.3-18.7%. Safe and complete deployment was accomplished in 92-100%. There was no device-related reintervention. There was a significant improvement in malperfusion in over 90% of the cases with varying degrees of remodelling (60-90%) of the downstream aorta. CONCLUSIONS: Open noncovered stent grafts represent a major technical advancement as an adjunct procedure for acute dissection repairs, e.g. hemiarch repair. It has potential for wider use by non-aortic surgeons due to simplicity of technique. Limited safety and efficacy data confirm the device to be safe, feasible and reproducible with potential for wider adoption. However, long-term trial and registry data are required before recommendations for standard use outside of high-volume experienced aortic centres.


Asunto(s)
Disección Aórtica , Implantación de Prótesis Vascular , Stents , Humanos , Disección Aórtica/cirugía , Implantación de Prótesis Vascular/métodos , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/métodos , Procedimientos Endovasculares/efectos adversos , Enfermedad Aguda , Diseño de Prótesis , Aneurisma de la Aorta Torácica/cirugía , Resultado del Tratamiento , Aneurisma de la Aorta/cirugía
7.
Nutr Metab Cardiovasc Dis ; 34(6): 1371-1380, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38503618

RESUMEN

BACKGROUND AND AIMS: Studies have demonstrated that obesity is paradoxically associated with reduced mortality following cardiac surgery. However, these studies have treated various types of cardiac surgery as a single entity. With mitral valve (MV) surgeries being the fastest-growing cardiac surgical interventions in North America, the purpose of this study was to identify the impact of body mass index (BMI) on long-term survival and cardiac remodelling of patients undergoing MV replacement (MVR). METHODS AND RESULTS: In this retrospective, single-center study, 1071 adult patients who underwent an MVR between 2004 and 2018 were stratified into five BMI groups (<20, 20-24.9, 25-29.9, 30-34.9, >35). Cox proportional hazard regression models were used to determine the association between BMI and all-cause mortality. Patients who were underweight had significantly higher all-cause mortality rates at the longest follow-up (median 8.2 years) than patients with normal weight (p = 0.01). Patients who were in the obese group had significantly higher readmission rates due to myocardial infarction (MI) at the longest follow-up (p = 0.017). Subgroup analysis revealed a significant increase in long-term all-cause mortality for female patients who were underweight. Significant changes in left atrial size, mitral valve peak and mean gradients were seen in all BMI groups. CONCLUSIONS: For patients undergoing mitral valve replacement, BMI is unrelated to operative outcomes except for patients who are underweight.


Asunto(s)
Índice de Masa Corporal , Implantación de Prótesis de Válvulas Cardíacas , Válvula Mitral , Obesidad , Remodelación Ventricular , Humanos , Femenino , Masculino , Estudios Retrospectivos , Persona de Mediana Edad , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Factores de Tiempo , Válvula Mitral/cirugía , Válvula Mitral/fisiopatología , Factores de Riesgo , Resultado del Tratamiento , Anciano , Obesidad/mortalidad , Obesidad/fisiopatología , Obesidad/cirugía , Obesidad/complicaciones , Obesidad/diagnóstico , Medición de Riesgo , Adulto , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/mortalidad , Enfermedades de las Válvulas Cardíacas/fisiopatología , Causas de Muerte , Readmisión del Paciente
9.
Can J Cardiol ; 2024 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-38552791

RESUMEN

Minimally invasive mitral valve surgery (MiMVS) has been increasing in prevalence. This review focuses on the approaches, clinical outcomes, and patient selection for MiMVS. There are 4 minimally invasive approaches to the mitral valve: right mini-thoracotomy (including video-assisted and fully endoscopic), robotic mitral surgery, and transapical beating heart off-pump neochordal repair. Advantages over conventional surgery include less blood loss and transfusion, improved postoperative mobility, shorter length of stay, less postoperative atrial fibrillation, fewer surgical site infections, and improved cosmesis. This range of minimally invasive techniques will continue to evolve, providing options that are tailored for different patient populations.

10.
J Emerg Nurs ; 50(1): 84-94, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37480901

RESUMEN

INTRODUCTION: The study purpose was to obtain an understanding of both the types of questions mandated for the triage encounter in emergency departments across the United States and how emergency nurses perceive the relevance of these questions to the triage process. METHODS: A qualitative descriptive exploratory study using focus group data was used. Data were collected at an in-person emergency nursing conference held in September 2022. Data were analyzed using Mayring's 8-step process. RESULTS: Participants (n = 35) voiced concerns about a lack of expertise at all points in the triage process. The overarching problem is reported as data required by regulatory agencies are conflated with triage assessment information. Participants in this study reported that the conflation of the triage assessment with regulatory compliance is causing significant issues in the ability of emergency nurses to appropriately evaluate patient presentations. Thematic categories were identified as who's assessing the patients? assessment or compliance? important questions, situationally important questions, questions asked before discharge, and the lack of emergency nurse input. DISCUSSION: The conflation of regulatory data collection with patient assessment at the initial triage encounter challenges the ability of the emergency nurse to rapidly and accurately identify patients at risk of deterioration. We recommend that initial triage processes encompass questions that focus on establishing the stability of the patient and the safety of the waiting room and include inquiry relevant to the patient presentation.


Asunto(s)
Enfermería de Urgencia , Triaje , Humanos , Investigación Cualitativa , Grupos Focales , Servicio de Urgencia en Hospital , Recolección de Datos
11.
J Thorac Cardiovasc Surg ; 167(3): 935-943.e5, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37084820

RESUMEN

OBJECTIVE: We compared perioperative outcomes of patients with acute type A aortic dissection undergoing hemiarch (HA) versus extended arch (EA) repair with or without descending aortic intervention. METHODS: Nine hundred twenty-nine patients underwent acute type A aortic dissection repair (2002-2021, 9 centers) including open distal repair (HA) with or without additional EA repair. EA with intervention on the descending aorta (EAD) included elephant trunk, antegrade thoracic endovascular aortic replacement, or uncovered dissection stent. EA with no descending intervention (EAND), included unstented suture-only methods. Primary outcomes were in-hospital mortality, permanent neurologic deficit, computed tomography malperfusion resolution, and a composite. Multivariable logistic regression was also performed. RESULTS: Mean age was 66 ± 18 years, 30% (278 out of 929) were women, and HA was performed more frequently (75% [n = 695]) than EA (25% [n = 234]). EAD techniques included: dissection stent (39 out of 234 [17%]), thoracic endovascular aortic replacement (18 out of 234 [7.7%]), and elephant trunk (87 out of 234 [37%]). In-hospital mortality (EA: n = 49 [21%] and HA: n = 129 [19%]; P = .42), and neurological deficit (EA: n = 43 [18%] and HA: n = 121 [17%]; P = .74) were similar. EA was not independently associated with death (EA vs HA odds ratio, 1.09; 95% CI, 0.77-1.54; P = .63) or neurologic deficit (EA vs HA odds ratio, 0.85; 95% CI, 0.47-1.55; P = .59). Composite adverse events differed significantly (EA vs HA odds ratio, 1.47; 95% CI, 1.16-1.87; P = .001). Malperfusion resolved more frequently after EAD (EAD: n = 32 [80%], EAND: n = 18 [56%], HA: n = 71 [50%]; P = .004), although multivariable analysis was not significant (EAD vs HA odds ratio, 2.17; 95% CI, 0.83-5.66; P = .10). CONCLUSIONS: Extended arch interventions pose similar perioperative mortality and neurologic risks as Hemiarch. Descending aortic reinforcement may promote malperfusion restoration. Extended techniques should be approached with caution in acute dissection due to increased risk of adverse events.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Enfermedad Aguda , Resultado del Tratamiento , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Aorta/cirugía , Stents , Estudios Retrospectivos , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/etiología
12.
Can J Cardiol ; 40(3): 470-475, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37839655

RESUMEN

BACKGROUND: A distal anastomotic new entry tear (DANE) can occur at the time of surgical repair for acute type A aortic dissection (ATAAD). This study aimed to compare the occurrence of DANE following a standard hemiarch repair with that following a hemiarch repair with an uncovered arch dissection stent. METHODS: All patients who received a hemiarch repair or a hemiarch repair with an Ascyrus Medical Dissection Stent (AMDS) for ATAAD from 2017 to 2021 were included. Baseline and intra- and postoperative characteristics were collected. All available pre- and postoperative computed tomographic scans were analysed. The primary outcome measures were the incidence of DANE, positive aortic remodelling, mortality, and aortic reintervention rates at last follow-up. RESULTS: A total of 114 patients underwent repair of Debakey I ATAAD during the study period with either an isolated hemiarch (n = 77) or a hemiarch with AMDS (n = 37). There was no significant difference in mortality (P = 0.768) or other in-hospital adverse events. During the follow-up period, DANE occurred in 43.3% (n = 26) of the isolated hemiarch group and in 11.8% (n = 4) of the hemiarch with AMDS group (P = 0.002). The incidence of false lumen thrombosis and obliteration favoured the AMDS group in the aortic arch (P = 0.029), the proximal descending thoracic aorta (P = 0.031), and level of pulmonary artery bifurcation (P = 0.044). CONCLUSIONS: The incidence of DANE is significantly reduced with the addition of an AMDS at the time of hemiarch repair for ATAAD repair. Further follow-up is necessary to identify late aortic complications that may have been prevented by reducing the incidence of postoperative DANE.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Humanos , Aneurisma de la Aorta Torácica/diagnóstico , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/etiología , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/métodos , Resultado del Tratamiento , Enfermedad Aguda , Estudios Retrospectivos , Disección Aórtica/diagnóstico , Disección Aórtica/cirugía , Stents , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Complicaciones Posoperatorias/etiología
14.
Simul Healthc ; 2023 Oct 18.
Artículo en Inglés | MEDLINE | ID: mdl-37851383

RESUMEN

INTRODUCTION: A recent needs assessment in Canadian cardiac surgery programs identified the desire for a coronary artery bypass (CABG) and aortic valve replacement (AVR) simulation model for home practice. We aimed to develop and assess a portable, adjustable task trainer for cardiac surgical skills with high functional task alignment. METHODS: Intraoperative measurements were taken from patients undergoing elective CABG and AVR (N = 30). Measurements were taken in 3 axes and used to create a chest cavity that resembles the mediastinal constraints of a patient undergoing CABG and AVR. The task trainer is adjustable on the following 3 levels: (1) size of the incision, (2) depth of the chest, and (3) relative position of coronary artery or aortic valve model within the chest. Three groups (novices, intermediates, and experts) of cardiac surgery members evaluated the task trainer for functional task alignment and construct validity. RESULTS: The CABG and AVR model had high functional task alignment. There was a high satisfaction for both models and all participants would recommend the AVR and CABG model as an educational tool. Performance time significantly differed between the groups for both models (CABG: P = 0.032 and AVR: P = 0.001), as well as number of errors (CABG: P = 0.04 and AVR: P = 0.043). CONCLUSIONS: Using real patient data, we were able to develop an adjustable task trainer for training principles of CABG and AVR. Our pilot study provides preliminary sources of evidence for validity and future study will look to assess transferability of skill to the operating room.

15.
bioRxiv ; 2023 Oct 17.
Artículo en Inglés | MEDLINE | ID: mdl-37905143

RESUMEN

Significance: Genetically encoded calcium ion (Ca2+) indicators (GECIs) are powerful tools for monitoring intracellular Ca2+ concentration changes in living cells and model organisms. In particular, GECIs have found particular utility for monitoring the transient increase of Ca2+ concentration that is associated with the neuronal action potential. However, the palette of highly optimized GECIs for imaging of neuronal activity remains relatively limited. Expanding the selection of available GECIs to include new colors and distinct photophysical properties could create new opportunities for in vitro and in vivo fluorescence imaging of neuronal activity. In particular, blue-shifted variants of GECIs are expected to have enhanced two-photon brightness, which would facilitate multiphoton microscopy. Aim: We describe the development and applications of T-GECO1 - a high-performance blue-shifted GECI based on the Clavularia sp.-derived mTFP1. Approach: We used protein engineering and extensive directed evolution to develop T-GECO1. We characterize the purified protein and assess its performance in vitro using one-photon excitation in cultured rat hippocampal neurons, in vivo using one-photon excitation fiber photometry in mice, and ex vivo using two-photon Ca2+ imaging in hippocampal slices. Results: The Ca2+-bound state of T-GECO1 has an excitation peak maximum of 468 nm, an emission peak maximum of 500 nm, an extinction coefficient of 49,300 M-1cm-1, a quantum yield of 0.83, and two-photon brightness approximately double that of EGFP. The Ca2+-dependent fluorescence increase is 15-fold and the apparent Kd for Ca2+ is 82 nM. With two-photon excitation conditions at 850 nm, T-GECO1 consistently enabled detection of action potentials with higher signal-to-noise (SNR) than a late generation GCaMP variant. Conclusion: T-GECO1 is a high performance blue-shifted GECI that, under two-photon excitation conditions, provides advantages relative to late generation GCaMP variants.

17.
J Emerg Nurs ; 49(5): 714-723, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37480900

RESUMEN

INTRODUCTION: Previous research describes a significant knowledge deficit in obstetrical care in emergency settings. In a post-Roe environment, additional medicolegal challenges are documented across the obstetrics and gynecology landscape, but an understudied care setting is the emergency department, where patients may present to a practice environment where there is limited or no obstetrical care available. It is unknown how emergency nurses make decisions around these types of presentations. The purpose of this study was to explore the clinical decision-making processes of emergency nurses in the care of patients with obstetrical emergencies in the context of limited or absent access to abortion care and the impact of those processes on patient care. METHODS: Qualitative exploratory approach using interview data (n = 13) and situational analysis was used. RESULTS: Situational mapping uncovered human elements comprised nurses, providers, pregnant people, and families; nonhuman elements comprised legislation, education, and legal understanding. Social worlds mapping included challenges of inexperience, conflict about clinical responsibility, uncertainty about the meaning of legislation, and passivity around implications for patient care. Positional mapping yielded both the overlapping discourses around the phenomenon of interest and the area of silence around abortion-limiting legislation. DISCUSSION: We found that emergency nurses in states with abortion care-limiting laws had significant self-reported deficits in both education and training around the management of obstetrical emergencies. In this sample, there was a surprising lack of awareness of care-limiting legislation and the clinical, ethical, and legal implications for both emergency care staff and for patients.


Asunto(s)
Servicios Médicos de Urgencia , Enfermeras y Enfermeros , Femenino , Embarazo , Humanos , Urgencias Médicas , Escolaridad , Toma de Decisiones Clínicas
20.
Future Cardiol ; 19(2): 65-69, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36786237

RESUMEN

Enterococcus faecalis is the third most common organism to cause infective endocarditis and is associated with high rates of morbidity and mortality. E. faecalis infective endocarditis often presents with a subacute course and with nonspecific constitutional symptoms. Complications related to E. faecalis infective endocarditis are common and include embolic events, abscess formation and pseudoaneurysm formation. Contained annular rupture is a complication of E. faecalis infective endocarditis that, to the authors knowledge, has not been previously described in the literature. Herein, we present an unusual case of a 62-year-old male presenting with classical symptoms of E. faecalis infective endocarditis which resulted in an unusual complication of this condition, a contained annular rupture and the surgical management undertaken to correct this condition.


Enterococcus faecalis is the third most common organism to cause infection of the heart and heart valves and is associated with high rates of complications and death. Complications related to E. faecalis heart infections are common and include dislodging of infected material, abscess formation and injury to blood vessel walls. Contained rupture of the aortic valve annulus is a complication of E. faecalis infections that, to the authors knowledge, has not been previously described in the literature. Herein, we present an unusual case of a 62-year-old male presenting with classical symptoms of E. faecalis infection of the heart which resulted in an unusual complication of this condition, a contained annular rupture and the surgical management undertaken to correct this condition.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Infecciones por Bacterias Grampositivas , Masculino , Humanos , Persona de Mediana Edad , Enterococcus faecalis , Infecciones por Bacterias Grampositivas/complicaciones , Infecciones por Bacterias Grampositivas/diagnóstico , Endocarditis Bacteriana/complicaciones , Endocarditis Bacteriana/diagnóstico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA