Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Analyst ; 146(6): 2065-2073, 2021 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-33538714

RESUMEN

Biosensing platforms are answering the increasing demand for analytical tools for environmental monitoring of small molecules, such as per- and polyfluoroalkyl substances (PFAS). By transferring toxicological findings in bioreceptor design we can develop innovative pathways for biosensor design. Indeed, toxicological studies provide fundamental information about PFAS-biomolecule complexes that can help evaluate the applicability of the latter as bioreceptors. The toolbox of native mass spectrometry (MS) can support this evaluation, as shown by the two case studies reported in this work. The analysis of model proteins' (i.e. albumin, haemoglobin, cytochrome c and neuroglobin) interactions with well-known PFAS, such as perfluorooctanoic acid (PFOA) and perfluorooctanesulfonic acid (PFOS), demonstrated the potential of this native MS screening approach. In the first case study, untreated albumin and delipidated albumin were compared in the presence and absence of PFOA confirming that the delipidation step increases albumin affinity for PFOA without affecting protein stability. In the second case study, the applicability of our methodology to identify potential bioreceptors for PFOS/PFOA was extended to other proteins. Structurally related haemoglobin and neuroglobin revealed a 1 : 1 complex, whereas no binding was observed for cytochrome c. These studies have value as a proof-of-concept for a general application of native MS to identify bioreceptors for toxic compounds.


Asunto(s)
Fluorocarburos , Albúminas , Fluorocarburos/toxicidad , Espectrometría de Masas
2.
Protein Sci ; 30(4): 830-841, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33550662

RESUMEN

Perfluorooctanoic acid (PFOA) is a toxic compound that is absorbed and distributed throughout the body by noncovalent binding to serum proteins such as human serum albumin (hSA). Though the interaction between PFOA and hSA has been already assessed using various analytical techniques, a high resolution and detailed analysis of the binding mode is still lacking. We report here the crystal structure of hSA in complex with PFOA and a medium-chain saturated fatty acid (FA). A total of eight distinct binding sites, four occupied by PFOAs and four by FAs, have been identified. In solution binding studies confirmed the 4:1 PFOA-hSA stoichiometry and revealed the presence of one high and three low affinity binding sites. Competition experiments with known hSA-binding drugs allowed locating the high affinity binding site in sub-domain IIIA. The elucidation of the molecular basis of the interaction between PFOA and hSA might provide not only a better assessment of the absorption and elimination mechanisms of these compounds in vivo but also have implications for the development of novel molecular receptors for diagnostic and biotechnological applications.


Asunto(s)
Caprilatos/química , Fluorocarburos/química , Modelos Moleculares , Albúmina Sérica Humana/química , Cristalografía por Rayos X , Humanos , Dominios Proteicos
3.
Talanta ; 210: 120667, 2020 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-31987161

RESUMEN

In this paper we present a novel combined electrochemical-spectroscopic approach suitable to monitor trace levels of heavy metals directly in edible oils. The method is based on the electrochemical preconcentration/extraction of the analyte from the tested real matrix by cathodic deposition onto a Pt working electrode, then transfer and anodic re-oxidation of the metallic deposit to a "clean" aqueous solution, suitable for the subsequent spectroscopic analysis. The procedure has been here focused to the determination of lead in extra virgin olive oil (EVOO), performed by applying ICP-QMS or GFAAS techniques. To this aim, the EVOO samples were mixed with proper amounts of the room temperature ionic liquid (RTIL) [P14,6,6,6]+[NTf2]-, in order to obtain a non-aqueous supporting electrolyte suitable for the electrodeposition process. The feasibility and performance of the analytical strategy were at first tested in standard solutions of Pb(II) in RTIL, produced by anodic dissolution of lead in the RTIL, as well as in olive oil samples mixed with 0.5 M RTIL and spiked with known amounts of Pb(II). The optimisation of the electrochemical parameters was achieved by applying a D-Optimal Design, properly set up to optimise the efficiency of the deposition and re-oxidation steps, quantitative recovery and measurement time. Finally, the analytical procedure was applied to the determination of Pb content in some Italian EVOOs, without any need of performing mineralization pretreatments. Data obtained with the proposed procedure satisfactorily agree with those achieved by ICP-QMS analysis after microwave digestion, being differences between the two approaches within 10%, with the advantage of reducing to half the pretreatment time, operating at room temperature and avoiding the use of aggressive solvents.


Asunto(s)
Técnicas Electroquímicas , Plomo/análisis , Aceite de Oliva/química , Espectrometría de Masas
4.
Materials (Basel) ; 12(18)2019 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-31540392

RESUMEN

External surfaces of stones used in historic buildings often carry high artistic value and need to be preserved from the damages of time, especially from the detrimental effects of the weathering. This study aimed to test the effectiveness and compatibility of some new environmentally-friendly materials for stone consolidation, as the use thereof has been so far poorly investigated. The treatments were based on combinations of an aqueous solution of di-ammonium phosphate (DAP) and two calcium-based nanomaterials, namely a commercial nanosuspension of Ca(OH)2 and a novel nanosuspension of calcite. The treatments were applied to samples of two porous stones: a limestone and a sandstone. The effectiveness of the treatments was assessed using scanning electron microscopy coupled with energy-dispersive X-ray spectroscopy, Fourier-transform infrared spectroscopy, ultrasound pulse velocity test, colour measurements, and capillary water absorption test. The results suggest that the combined use of DAP and Ca-based nanosuspensions can be advantageous over other commonly used consolidants in terms of retreatability and physical-chemical compatibility with the stone. Some limitations are also highlighted, such as the uneven distribution and low penetration of the consolidants.

5.
Sensors (Basel) ; 19(5)2019 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-30862087

RESUMEN

Celiac disease (CD) is a gluten-dependent autoimmune disorder affecting a significant percentage of the general population, with increasing incidence particularly for children. Reliable analytical methods suitable for the serological diagnosis of the disorder are urgently required for performing both the early diagnosis and the follow-up of a patient adhering to a gluten-free diet. Herein we report on the preparation and application of a novel electrochemical immunosensor based on the use of ensembles of gold nanoelectrodes (NEEs) for the detection of anti-tissue transglutaminase (anti-tTG), which is considered one reliable serological marker for CD. To this end, we take advantage of the composite nature of the nanostructured surface of membrane-templated NEEs by functionalizing the polycarbonate surface of the track-etched membrane with tissue transglutaminase. Incubation of the functionalized NEE in anti-tTG samples results in the capture of the anti-tTG antibody. Confirmation of the recognition event is achieved by incubating the NEE with a secondary antibody labelled with horseradish peroxidase (HRP): in the presence of H2O2 as substrate and hydroquinone as redox mediator, an electrocatalytic current is indeed generated whose increment is proportional to the amount of anti-tTG captured from the sample. The optimized sensor allows a detection limit of 1.8 ng mL-1, with satisfactory selectivity and reproducibility. Analysis of serum samples from 28 individuals, some healthy and some affected by CD, furnished analytical results comparable with those achieved by classical fluoroenzyme immunoassay (FEIA). We note that the NEE-based immunosensor developed here detects the IgG isotype of anti-tTG, while FEIA detects the IgA isotype, which is not a suitable diagnostic marker for IgA-deficient patients.


Asunto(s)
Técnicas Biosensibles/métodos , Proteínas de Unión al GTP/metabolismo , Inmunoglobulina G/metabolismo , Transglutaminasas/metabolismo , Enfermedad Celíaca/metabolismo , Electroquímica/métodos , Electrodos , Humanos , Inmunoensayo , Proteína Glutamina Gamma Glutamiltransferasa 2
6.
ACS Sens ; 3(7): 1291-1298, 2018 07 27.
Artículo en Inglés | MEDLINE | ID: mdl-29911865

RESUMEN

This work is aimed at developing an electrochemical sensor for the sensitive and selective detection of trace levels of perfluorooctanesulfonate (PFOS) in water. Contamination of waters by perfluorinated alkyl substances (PFAS) is a problem of global concern due to their suspected toxicity and ability to bioaccumulate. PFOS is the perfluorinated compound of major concern, as it has the lowest suggested control concentrations. The sensor reported here is based on a gold electrode modified with a thin coating of a molecularly imprinted polymer (MIP), prepared by anodic electropolymerization of o-phenylenediamine (o-PD) in the presence of PFOS as the template. Activation of the sensor is achieved by template removal with suitable a solvent mixture. Voltammetry, a quartz crystal microbalance, scanning electron microscopy and elemental analysis were used to monitor the electropolymerization process, template removal, and binding of the analyte. Ferrocenecarboxylic acid (FcCOOH) has been exploited as an electrochemical probe able to generate analytically useful voltammetric signals by competing for the binding sites with PFOS, as the latter is not electroactive. The sensor has a low detection limit (0.04 nM), a satisfactory selectivity, and is reproducible and repeatable, giving analytical results in good agreement with those obtained by HPLC-MS/MS analyses.


Asunto(s)
Ácidos Alcanesulfónicos/análisis , Agua Potable/análisis , Técnicas Electroquímicas , Fluorocarburos/análisis , Impresión Molecular , Fenilendiaminas/química , Contaminantes Químicos del Agua/análisis , Técnicas Electroquímicas/instrumentación , Técnicas Electroquímicas/métodos , Electrodos , Diseño de Equipo , Oro/química , Límite de Detección , Impresión Molecular/instrumentación , Impresión Molecular/métodos
7.
Angew Chem Int Ed Engl ; 57(25): 7401-7407, 2018 06 18.
Artículo en Inglés | MEDLINE | ID: mdl-29701294

RESUMEN

Knowledge of the techniques employed by artists, such as the composition of the paints, colour palette, and painting style, is of crucial importance not only to attribute works of art to the workshop or artist but also to develop strategies and measures for the conservation and restoration of the art. While much research has been devoted to investigating the composition of an artist's materials from a qualitative point of view, little effort has been made in terms of quantitative analyses. This study aims to quantify the relative concentrations of binders (acrylic and alkyd) and inorganic pigments in different paint samples by IR and Raman spectroscopies. To perform this quantitative evaluation, reference samples of known concentrations were prepared to obtain calibration plots. In a further step, the quantification method was verified by additional test samples and commercially available paint tubes. The results obtained confirm that the quantitative method developed for IR and Raman spectroscopy is able to efficiently determine different pigment and binder concentrations of paint samples with high accuracy.

8.
Talanta ; 172: 133-138, 2017 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-28602285

RESUMEN

In this paper we present an electrochemical approach to prepare standard solutions of metal ions in a room temperature ionic liquid (IL), which can find useful application for analysis in hydrophobic matrices. The method, developed here for the case of lead ions, is based on the galvanostatic dissolution of a lead anode dipped directly in a suitable IL, namely tri-hexyl(tetradecyl)phosphonium bis (trifluoromethylsulfonyl) imide ([P14,6,6,6]+[NTf2]-). After each oxidation step, the metal dissolution process in the IL solutions was monitored by cyclic voltammetric measurements at a glassy carbon disk electrode. The results indicated that the peak current relevant to the reduction of the electro-generated Pb(II) increased linearly while increasing the oxidation time. By varying the oxidation time from 200 to 6000s, a set of Pb(II)/[P14,6,6,6]+[NTf2]- solutions at concentrations ranging between 10 and 300µgg-1 was prepared. To validate the efficiency of the electrochemical procedure to produce metal ion standard solutions, the Pb content was quantified by developing a microwave digestion procedure specifically suitable for the IL medium, followed by ICP-QMS analysis in the digested standards. The results indicated a satisfactory agreement between concentrations found by ICP-QMS and calculated from electrochemical data, with a coulometric efficiency of Pb(II) generation in ionic liquid ≥95.6%. Finally, the applicability of the Pb(II)/IL solutions as standards for analyses in hydrophobic media was tested by determining, by ICP-QMS, the Pb content in an extra-virgin olive oil spiked with known amounts of a Pb(II)/IL standard. Satisfactory Pb recoveries, ≥96%, were measured.


Asunto(s)
Electroquímica/normas , Interacciones Hidrofóbicas e Hidrofílicas , Líquidos Iónicos/química , Plomo/química , Aceite de Oliva/análisis , Aceite de Oliva/química , Minerales/química , Oxidación-Reducción , Estándares de Referencia , Soluciones
9.
Sensors (Basel) ; 17(1)2016 Dec 30.
Artículo en Inglés | MEDLINE | ID: mdl-28042840

RESUMEN

Since the first reports dating back to the mid-1990s, ensembles and arrays of nanoelectrodes (NEEs and NEAs, respectively) have gained an important role as advanced electroanalytical tools thank to their unique characteristics which include, among others, dramatically improved signal/noise ratios, enhanced mass transport and suitability for extreme miniaturization. From the year 2000 onward, these properties have been exploited to develop electrochemical biosensors in which the surfaces of NEEs/NEAs have been functionalized with biorecognition layers using immobilization modes able to take the maximum advantage from the special morphology and composite nature of their surface. This paper presents an updated overview of this field. It consists of two parts. In the first, we discuss nanofabrication methods and the principles of functioning of NEEs/NEAs, focusing, in particular, on those features which are important for the development of highly sensitive and miniaturized biosensors. In the second part, we review literature references dealing the bioanalytical and biosensing applications of sensors based on biofunctionalized arrays/ensembles of nanoelectrodes, focusing our attention on the most recent advances, published in the last five years. The goal of this review is both to furnish fundamental knowledge to researchers starting their activity in this field and provide critical information on recent achievements which can stimulate new ideas for future developments to experienced scientists.

10.
Anal Bioanal Chem ; 407(12): 3377-91, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25716469

RESUMEN

In general the analysis of archeological glass represents a challenge for a wide variety of objects because of the presence of physical and/or chemical damage on the surface of the artifact, also known as weathering or corrosion. To retrieve accurate bulk elemental information by laser ablation-inductively coupled plasma-mass spectrometry (ICP-MS), the original, pristine glass needs to be "reached", thereby penetrating the alteration layer which is often more than 10 µm thick. To study this alteration layer the laser was operated in the drilling mode, either with a low (1 Hz) or a high (10 Hz) pulse repetition rate for a period of 50 s yielding detailed spatial information for ca. 20 elements over a shallow depth (ca. 5 µm) or less-detailed spatial information for 50-60 elements over a greater depth (ca. 50 µm). Quantitative elemental depth profiles (in wt%) were obtained with the so-called sum normalization calibration protocol, based on summation of the elements as their oxides to 100 wt%. We were able to associate the increase of SiO2 (in wt%) in the alteration layer to the volumetric mass density change in the glass as a result of depletion of Na2O and K2O. Also the interaction of the number of laser shots with the alteration layer is shown experimentally via depth measurements using profilometry. Chemical and physical changes in four ancient glass artifacts, directly and indirectly measureable by laser drilling, were studied as a function of internal and external factors such as age, composition, and exposure conditions.

11.
Anal Chim Acta ; 575(1): 16-24, 2006 Aug 04.
Artículo en Inglés | MEDLINE | ID: mdl-17723566

RESUMEN

A procedure for the standardization of ensembles of gold nanodisk electrodes (NEE) of 30 nm diameter is presented, which is based on the analytical comparison between experimental cyclic voltammograms (CV) obtained at the NEEs in diluted solutions of redox probes and CV patterns obtained by digital simulation. Possible origins of defects sometimes found in NEEs are discussed. Selected NEEs are then employed for the study of the electrochemical oxidation of iodide in acidic solutions. CV patterns display typical quasi-reversible behavior which involves associated chemical reactions between adsorbed and solution species. The main CV characteristics at the NEE compare with those observed at millimeter sized gold disk electrodes (Au-macro), apart a slight shift in E1/2 values and slightly higher peak to peak separation at the NEE. The detection limit (DL) at NEEs is 0.3 microM, which is more than one order of magnitude lower than DL at the Au-macro (4 microM). The mechanism of the electrochemical oxidation of iodide at NEEs is discussed. Finally, NEEs are applied to the direct determination of iodide at micromolar concentration levels in real samples, namely in some ophthalmic drugs and iodized table salt.

12.
Bioelectrochemistry ; 66(1-2): 29-34, 2005 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-15833699

RESUMEN

Ultrathin films of Nafion and Eastman-AQ 55 loaded with cytochrome c (cyt c) were obtained and transferred on indium tin oxide (ITO) electrodes via the Langmuir-Blodgett (LB) technique. The pressure-area isotherms for mixed ionomer-protein films indicate that the miscibility of cyt c in the interfacial layer is better for Nafion than for AQ 55. Interestingly, these composite films maintain the electroactivity of cyt c without requiring the addition of promoters or mediators. Both for AQ 55-cyt c and Nafion-cyt c films, the half-wave potential for the reversible reduction of ferricytochrome c corresponds to the value expected for the weakly adsorbed protein. The modified electrodes show electrocatalytic reaction with ascorbate anion. Comparison with previous literature reports indicate that for Nafion the LB coating procedure is unique in keeping the electroactivity of cyt c.


Asunto(s)
Grupo Citocromo c/química , Éteres/química , Polímeros de Fluorocarbono/química , Membranas Artificiales , Polímeros/química , Electroquímica , Potenciales de la Membrana , Propiedades de Superficie
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA