Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
1.
Int Dent J ; 2024 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-39030097

RESUMEN

INTRODUCTION AND AIMS: Root canal therapy is a crucial aspect of endodontic treatment aimed at preserving natural dentition. Over the years, advancements in three-dimensional (3D) technology have revolutionized diagnosis and treatment planning. Different 3D technologies are used in dental care, such as cone-beam computed tomography (CBCT), which ensures 3D slice visualization, root canal microanatomy, and dynamic navigation throughout the pulp cavity. By exploring the latest technological progress in this field, we seek to understand how these innovations are enhancing precision, efficiency, and patient outcomes, shedding light on the benefits and potential impact of 3D imaging in improving root canal procedures. METHODS: Literature was searched from different databases, including PubMed, ScienceDirect, The Cochrane Library, Scopus, and Google Scholar. Inclusion criteria involved studies on 3D technology in root canal therapy with comparison groups, including RCTs and non-RCTs. Excluded studies lacked 3D imaging advancements, a control group, or were review articles or case studies. Quality assessment utilized QUIN for in vitro studies and ROBINS-I for non-RCTs to evaluate the studies' validity. RESULTS: According to the PRISMA guidelines, among 5015 initial articles, 16 were included. CBCT was the most used 3D imaging technique for root imaging followed by micro-computed tomography (MCT) and limited CBCT (LCBCT) imaging methods. 2D radiographs and 2D histological methods and clearing techniques were the most common comparative modalities. Overall, 3D imaging streamlined dental treatment as clinicians could visualize much clearer and higher-quality images. Different resolutions and voxel sizes were applied to improve imaging quality. CONCLUSION: Three-dimensional imaging, especially CBCT, improves root canal treatments by providing superior image quality. CBCT outperforms other techniques like MCT and LCBCT, enhancing clarity. Varying resolutions and voxel sizes optimize the effectiveness of 3D imaging in root canal therapy. CLINICAL RELEVANCE: The advancements in 3D imaging technology, particularly CBCT, have significantly enhanced the diagnosis and treatment planning for root canal therapy. CBCT provides detailed insights into intricate root canal anatomy, improving diagnostic accuracy.

2.
Photodiagnosis Photodyn Ther ; 48: 104256, 2024 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-38914185

RESUMEN

AIM: This study aimed to assess the effectiveness of photobiomodulation therapy (PBM) in enhancing bone integration with dental implants. METHOD: PubMed, ScienceDirect, the Cochrane Library, Scopus, and Google Scholar were searched. Studies assessing PBM effectiveness with defined intervention/control groups were included, while those lacking specified laser types, involving severe maxillofacial defects or surgery, and not reporting outcomes related to dental implant osseointegration post-PBM therapy were excluded. The studies' risk of bias was assessed using Robvis for randomized controlled trials (RCTs) and ROBINS-I for non-RCTs. The meta-analysis was conducted utilizing a random-effects model at a significance level of 0.01. RESULTS: The study reviewed 26 papers involving 571 patients undergoing dental implant procedures with PBM/Low-Level Laser Therapy (LLLT) or placebo/control. Implant stability quotients (ISQ) analysis showed a non-significant difference (p = 0.06, mean difference: 1.02, 95 % CI: 0.28 to 1.75, I2=28 %), while the Periotest method indicated significant improvement in stability (p < 0.01, mean difference: -0.51, 95 % CI: -0.78 to -0.24, I2=71 %). PBM resulted in a significant bone density increase (p < 0.01, mean difference: 26, 95 % CI: 6.93 to 45.06, I2=91 %), but marginal bone loss showed no significant difference (p = 0.11, mean difference: 0.00, 95 % CI: -0.06 to 0.05, I2=45 %). Implant survival rate did not significantly differ (p = 0.73, mean difference: 1.56, 95 % CI: 0.38 to 6.46, I2=0 %). Most studies raised concerns regarding randomization. CONCLUSION: PBM could improve implant stability, as assessed with Periotest, and increase bone density, enhancing osseointegration. However, implant stability assessed with ISQ, marginal bone loss, and implant survival rate were comparable between the study groups.

3.
J Mater Sci Mater Med ; 35(1): 28, 2024 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-38833196

RESUMEN

AIM: This study aimed to comprehensively assess the biocompatibility and toxicity profiles of poly(methyl methacrylate) (PMMA) and its monomeric unit, methyl methacrylate (MMA), crucial components in dental materials for interim prosthetic restorations. METHODOLOGY: Molecular docking was employed to predict the binding affinities, energetics, and steric features of MMA and PMMA with selected receptors involved in bone metabolism and tissue development, including RANKL, Fibronectin, BMP9, NOTCH2, and other related receptors. The HADDOCK standalone version was utilized for docking calculations, employing a Lamarckian genetic algorithm to explore the conformational space of ligand-receptor interactions. Furthermore, molecular dynamics (MD) simulations over 100 nanoseconds were conducted using the GROMACS package to evaluate dynamic actions and structural stability. The LigandScout was utilized for pharmacophore modeling, which employs a shape-based screening approach to identify potential ligand binding sites on protein targets. RESULTS: The molecular docking studies elucidated promising interactions between PMMA and MMA with key biomolecular targets relevant to dental applications. MD simulation results provided strong evidence supporting the structural stability of PMMA complexes over time. Pharmacophore modeling highlighted the significance of carbonyl and hydroxyl groups as pharmacophoric features, indicating compounds with favorable biocompatibility profiles. CONCLUSION: This study underscores the potential of PMMA in dental applications, emphasizing its structural stability, molecular interactions, and safety considerations. These findings lay a foundation for future advancements in dental biomaterials, guiding the design and optimization of materials for enhanced biocompatibility. Future directions include experimental validation of computational findings and the development of PMMA-based dental materials with improved biocompatibility and clinical performance.


Asunto(s)
Materiales Biocompatibles , Materiales Dentales , Ensayo de Materiales , Simulación del Acoplamiento Molecular , Simulación de Dinámica Molecular , Polimetil Metacrilato , Materiales Biocompatibles/química , Polimetil Metacrilato/química , Materiales Dentales/química , Humanos , Ligandos , Simulación por Computador , Sitios de Unión
4.
BMC Oral Health ; 24(1): 676, 2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38858745

RESUMEN

BACKGROUND: Clinicians often utilize both flowable and packable composites concurrently in bonding fixed retainers. Thus, this study aimed to assess the synergistic effect of these composites in the bonding process. METHODS: This in vitro study divided specimens into three groups: flowable composite (nano-hybrid, Tetric N-Flow, Ivoclar Vivadent), packable composite (nano-hybrid, Tetric N-ceram, Ivoclar Vivadent), and combined use of flowable and packable composite. Shear bond strength (SBS), adhesive remnant index (ARI), and wire pull-out resistance were compared among the groups. Statistical analyses were conducted using ANOVA and Tukey tests to compare study groups. Additionally, Chi-square and Kruskal-Wallis tests were employed to analyze the ARI index among the groups. RESULTS: ANOVA results indicated no statistically significant differences among test groups (P = 0.129) regarding SBS. However, a significant difference existed between flowable and packable composite groups (P = 0.01) regarding ARI scores. Among the study groups, flowable composite exhibited the highest frequencies of ARI scores of 1 and 2, whereas packable composite showed the highest frequency of ARI scores of 0. The combined group had higher frequencies of ARI scores of 0 and 1 compared to the flowable composite. The wire pull-out test revealed that the combined application of flowable and packable composite resulted in significantly lower detachments compared to the packable composite alone (P = 0.008). However, no significant differences were observed in the comparisons between the flowable-packable (P = 0.522) and combined-flowable (P = 0.128) groups. CONCLUSION: The combined use of flowable and packable composites for fixed retainers demonstrated adequate shear bond strength and ideal ARI scores, suggesting it as a suitable adhesive system for bonding orthodontic fixed retainers.


Asunto(s)
Resinas Compuestas , Ensayo de Materiales , Retenedores Ortodóncicos , Resistencia al Corte , Resinas Compuestas/química , Técnicas In Vitro , Recubrimiento Dental Adhesivo/métodos , Análisis del Estrés Dental , Humanos
5.
Arch Oral Biol ; 166: 106032, 2024 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-38943858

RESUMEN

OBJECTIVE: This study aimed to investigate the correlation between genetic factors and the occurrence and progression of temporomandibular disorders (TMDs) using a comprehensive review and meta-analysis. DESIGN: A comprehensive search was conducted using the ScienceDirect, PubMed, Cochrane Library, Dimensions, and Emerald databases. A reviewer selected the study using modified PICO criteria, considering human subjects with TMDs, comparing different genetic factors among TMD and non-TMD patients, and reporting TMD signs and symptoms as outcomes. The methodological standards of the eligible papers were assessed using the Joanna Briggs Institute (JBI) Critical Appraisal Checklist for Non-randomized Experimental Investigations. Information was collected methodically and examined. RESULTS: The electronic database search yielded 851 articles, 19 of which were included in this study. The data analysis showed a significant influence of genetic factors, such as polymorphisms and gene differences, on the development of TMD signs and symptoms, such as myofascial pain, chronic pain, and disc displacement. In addition, gene polymorphism significantly influenced TMD development, with an odds ratio of 2.46 (1.93-3.14) and p of 0.00001. CONCLUSIONS: Genetic factors significantly influenced TMD signs and symptoms, and genetic polymorphisms significantly influenced TMD onset and progression. Further research should be conducted in diverse settings with larger sample sizes to verify and validate these findings.

6.
Maxillofac Plast Reconstr Surg ; 46(1): 23, 2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38900334

RESUMEN

BACKGROUND: Focal and florid cemento-osseous dysplasia are benign fibro-osseous lesions affecting the quality and quantity of the jawbones. This study aimed to determine the viability of implant-based approaches in the affected patients. MAIN TEXT: Different scientific databases, including PubMed/MEDLINE, Scopus, Web of Science, Embase, the Cochrane Library, and Google Scholar, were searched until October 8, 2023, using a pre-determined search strategy. Two reviewers screened the retrieved reports and extracted the required information from the included studies. The eligibility criteria included English-language case reports/series or clinical trials. The JBI critical appraisal checklist for case reports was used to assess the methodological quality of the included studies. Three studies were deemed eligible to be included in this study out of the initial 202 records found. Five implants were placed in three patients, positioned in the proximity of the lesion area, without any additional treatment to remove the pathology. The mandibular posterior area was the affected site in all patients. Only one implant failed in one patient after 16 years, which was attributed to peri-implantitis and not the lesion. Other implants demonstrated successful maintenance over follow-up periods. CONCLUSIONS: Although the number of the included records was relatively low to draw firm conclusions, it seems that implant-based treatments in patients with focal/florid cemento-osseous dysplasia could be viable, considering a conservative and well-planned approach.

7.
BMC Oral Health ; 24(1): 693, 2024 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-38877446

RESUMEN

BACKGROUND: The effectiveness of alveolar ridge preservation on bone regeneration and tissue healing has been thoroughly documented in the literature. This study aimed to evaluate the peri-implant soft and hard tissue changes after alveolar ridge preservation using either platelet-rich fibrin (PRF) or freeze-dried bone allograft (FDBA) over a 12-month period following the prosthetic loading of implants. METHODS: In this randomized clinical trial, 40 individuals were recruited for alveolar ridge preservation using (1) FDBA or (2) PRF in incisal/premolar areas. At two follow-up sessions (six- and 12-months post-implant insertion), radiographic imaging and clinical examinations assessed marginal bone loss and soft tissue factors, including gingival recession and bleeding on probing. The differences between study groups were analyzed using Generalized estimating Equations, the Binary logistic regression model, and Cochran's Q test. RESULTS: There was a statistically significant difference regarding gingival recession at both follow-up evaluations; values in the PRF group were considerably lower compared to the FDBA group (p < 0.05). The mean values for vertical marginal bone loss and bleeding on probing showed no significant differences between the two study groups (p > 0.05). CONCLUSIONS: Except for gingival recession, applying PRF yielded comparable clinical results to FDBA after one year of implant loading and could be recommended as a potential biomaterial for alveolar ridge preservation following tooth extractions. CLINICAL TRIAL REGISTRATION: The research protocol was registered in the Protocol Registration and Results System on 13/08/2021, available at https://clinicaltrials.gov/ (NCT05005377).


Asunto(s)
Pérdida de Hueso Alveolar , Trasplante Óseo , Liofilización , Fibrina Rica en Plaquetas , Humanos , Femenino , Masculino , Trasplante Óseo/métodos , Persona de Mediana Edad , Pérdida de Hueso Alveolar/prevención & control , Pérdida de Hueso Alveolar/diagnóstico por imagen , Adulto , Aumento de la Cresta Alveolar/métodos , Recesión Gingival/prevención & control , Recesión Gingival/cirugía , Aloinjertos
8.
J Dent Educ ; 2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38807268

RESUMEN

PURPOSE: Virtual reality (VR) simulations have been increasingly employed to train dental students prior to clinical practice. According to the literature, blended learning designs in the form of VR simulations can be utilized by both dental students and instructors to provide quality education. They can also save time and improve motor skills before students enter clinical stages. Therefore, this study was designed to review the importance of available VR simulators and their impact on student learning and outcomes. METHOD: The Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines were followed to review the literature systematically, and different databases such as PubMed, ScienceDirect, Cochrane Library, Scopus, and Google Scholar were searched (up to December 2023) for relevant articles using keywords: "virtual reality," "virtual reality simulators," "virtual reality simulation," and "dental education." The Mixed Methods Appraisal Tool was used to assess the study quality. RESULTS: After a comprehensive literature search, 1477 research articles were identified, of which 16 were included in the present study. In terms of students' learning outcomes, engagement, and optimal approach, a significant improvement was observed compared to conventional training methods, specifically in their knowledge, performance, confidence, and psychomotor skills. CONCLUSION: The findings suggest that VR simulators enhance the overall learning abilities of dental students and should be regarded as an integral component of the current curriculum. However, it is important to recognize that VR simulators cannot fully substitute traditional training methods; rather, they can effectively complement them.

9.
BMC Oral Health ; 24(1): 557, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38735940

RESUMEN

BACKGROUND: Dental resin-based composites are widely recognized for their aesthetic appeal and adhesive properties, which make them integral to modern restorative dentistry. Despite their advantages, adhesion and biomechanical performance challenges persist, necessitating innovative strategies for improvement. This study addressed the challenges associated with adhesion and biomechanical properties in dental resin-based composites by employing molecular docking and dynamics simulation. METHODS: Molecular docking assesses the binding energies and provides valuable insights into the interactions between monomers, fillers, and coupling agents. This investigation prioritizes SiO2 and TRIS, considering their consistent influence. Molecular dynamics simulations, executed with the Forcite module and COMPASS II force field, extend the analysis to the mechanical properties of dental composite complexes. The simulations encompassed energy minimization, controlled NVT and NPT ensemble simulations, and equilibration stages. Notably, the molecular dynamics simulations spanned a duration of 50 ns. RESULTS: SiO2 and TRIS consistently emerged as influential components, showcasing their versatility in promoting solid interactions. A correlation matrix underscores the significant roles of van der Waals and desolvation energies in determining the overall binding energy. Molecular dynamics simulations provide in-depth insights into the mechanical properties of dental composite complexes. HEMA-SiO2-TRIS excelled in stiffness, BisGMA-SiO2-TRIS prevailed in terms of flexural strength, and EBPADMA-SiO2-TRIS offered a balanced combination of mechanical properties. CONCLUSION: These findings provide valuable insights into optimizing dental composites tailored to diverse clinical requirements. While EBPADMA-SiO2-TRIS demonstrates distinct strengths, this study emphasizes the need for further research. Future investigations should validate the computational findings experimentally and assess the material's response to dynamic environmental factors.


Asunto(s)
Materiales Biocompatibles , Resinas Compuestas , Simulación del Acoplamiento Molecular , Simulación de Dinámica Molecular , Dióxido de Silicio , Resinas Compuestas/química , Dióxido de Silicio/química , Materiales Biocompatibles/química , Materiales Dentales/química , Metacrilatos/química , Poliuretanos/química , Ácidos Polimetacrílicos/química , Polietilenglicoles/química , Resinas Acrílicas/química
10.
Discov Nano ; 19(1): 95, 2024 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-38814562

RESUMEN

BACKGROUND: Nanoparticles are increasingly used in dentistry for various applications, including enhancing the mechanical properties of denture base resins. This study aimed to comprehensively review and analyze the research landscape of nanoparticles and their effect on the flexural strength of denture base resins to identify key research areas and trends and to highlight the importance of collaboration between authors and institutions. METHODS: A Bibliometric Analysis was conducted using the Keywords "Nanoparticle*" AND "Denture*" OR "CAD/CAM." The literature search from the WOS database was restricted to the publication years 2011 to 2022. RESULTS: Key findings encompass an increase in research publications but a decline in citations. Saudi Arabia, China, and Iraq led this research, with specific institutions excelling. Notable journals with high impact factors were identified. Authorship patterns show variations in citation impact. Additionally, keyword analysis revealed that current research trends offer insights into influential authors and their networks. CONCLUSIONS: The analysis of nanoparticles and denture base resins reveals a dynamic and evolving landscape that emphasizes the importance of collaboration, staying current with research trends, and conducting high-quality research in this ever-evolving domain.

11.
J Prosthet Dent ; 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38772783

RESUMEN

STATEMENT OF PROBLEM: Additive (3-dimensional printing) and subtractive (milling) methods are digital approaches to fabricating zirconia restorations. Comparisons of their resultant fabrication accuracy and restoration fit are lacking. PURPOSE: The purpose of this systematic review and meta-analysis was to evaluate the accuracy and fit of monolithic zirconia crowns fabricated by 3-dimensional printing and milling. MATERIAL AND METHODS: The PubMed (Medline), Scopus, Embase, Web of Science, Cochrane Library, and Google Scholar databases were searched up to August 2023. Eligible records were included, and the standardized mean difference (SMD) analyzed 4 outcomes: marginal fit, intaglio fit, trueness, and precision. Publication bias was analyzed with Trim-and-fill, the Egger regression test, and Begg funnel plot. Methodological quality was rated using the QUIN tool. RESULTS: A total of 15 publications were found eligible out of the initial 6539 records. The 3-dimensional printing group demonstrated a lower marginal fit (SMD=1.46, 95% CI=[0.67, 2.26], P<.001; I2=83%, P<.001) and trueness (SMD=0.69, 95% CI=[0.20, 1.18], P=.006; I2=88%, P<.001) and a significantly higher precision (SMD=-2.19, 95% CI=[-2.90, -1.48], P<.001; I2=56%, P=.045). The intaglio fit did not differ significantly across the study groups (SMD=0.77, 95% CI=[-0.22, 1.77], P=.127; I2=87%, P<.001). CONCLUSIONS: Given the high degree of heterogeneity, it can be cautiously concluded that while 3-dimensional printing led to greater precision, the outcomes of the 2 accuracy and adaptation parameters most crucial to the longevity of the restorations-trueness and marginal fit-showed the superiority of the milling technique.

12.
J Appl Biomater Funct Mater ; 22: 22808000241250118, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38706266

RESUMEN

Despite the development of implant-supported prostheses, there are still patients for whom conservative treatments such as resin-bonded fixed dental prostheses (RBFDPs) are more appropriate. This study's objective was to analyze the available research on full-ceramic RBFDPs. In this study, Web of Science, MEDLINE/PubMed, Scopus, Embase, Cochrane Library, and Google Scholar databases were searched for articles published in English between 2010 and 2020. A total of 14 studies were reviewed based on the eligibility criteria. The results showed that using a cantilever design with one abutment had an advantage over two abutments. Additionally, it was proposed that preparations designed with retentive aids, such as a proximal box, groove, and pinhole, could improve RBFDP survival rates. IPS e.max ZirCAD, In-Ceram alumina, and zirconia CAD/CAM were the most commonly used framework materials. Most studies used air abrasion, salinization, or hydrofluoric acid for surface treatment. Adhesive resin cements were the most frequently used type of cement. The survival rate of In-Ceram ceramics (85.3%-94.8%) was lower than that of In-Ceram zirconia and IPS e.max ZirCAD. Debonding, followed by framework fracture, was the leading cause of failure. Following 3-10 years follow-up, the survival percentage of all-ceramic RBFDPs ranged from 76% to 100%. Although RBFDPs have demonstrated satisfactory success as a conservative treatment, long-term follow-ups and higher sample sizes in clinical research are required to gain more reliable outcomes on the clinical success rate of various RBFDP designs.


Asunto(s)
Cerámica , Humanos , Cerámica/química , Cementos de Resina/química , Porcelana Dental/química , Prótesis Dental de Soporte Implantado , Dentadura Parcial Fija con Resina Consolidada , Circonio/química
13.
J Oral Rehabil ; 51(7): 1250-1302, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38570927

RESUMEN

BACKGROUND: Various medical conditions and the drugs used to treat them have been shown to impede or complicate dental implant surgery. It is crucial to carefully monitor the medical status and potential post-operative complications of patients with systemic diseases, particularly elderly patients, to minimize the risk of health complications that may arise. AIM: The purpose of this study was to review the existing evidence on the viability of dental implants in patients with systemic diseases and to provide practical recommendations to achieve the best possible results in the corresponding patient population. METHODS: The information for our study was compiled using data from PubMed, Scopus, Web of Science and Google Scholar databases and searched separately for each systemic disease included in our work until October 2023. An additional manual search was also performed to increase the search sensitivity. Only English-language publications were included and assessed according to titles, abstracts and full texts. RESULTS: In total, 6784 studies were found. After checking for duplicates and full-text availability, screening for the inclusion criteria and manually searching reference lists, 570 articles remained to be considered in this study. CONCLUSION: In treating patients with systemic conditions, the cost-benefit analysis should consider the patient's quality of life and expected lifespan. The success of dental implants depends heavily on ensuring appropriate maintenance therapy, ideal oral hygiene standards, no smoking and avoiding other risk factors. Indications and contraindications for dental implants in cases of systemic diseases are yet to be more understood; broader and hardcore research needs to be done for a guideline foundation.


Asunto(s)
Implantes Dentales , Humanos , Implantes Dentales/efectos adversos , Calidad de Vida , Implantación Dental Endoósea/efectos adversos , Complicaciones Posoperatorias/prevención & control , Análisis Costo-Beneficio , Factores de Riesgo , Atención Dental para Enfermos Crónicos
14.
J Oral Biol Craniofac Res ; 14(3): 335-338, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38680473

RESUMEN

The P2X7 receptor, a member of the P2X receptor family, plays a crucial role in various physiological processes, particularly pain perception. Its expression across immune, neuronal, and glial cells facilitates the release of pro-inflammatory molecules, thereby influencing pain development and maintenance, as evidenced by its association with pulpitis in rats. Notably, P2X receptors such as P2X3 and P2X7 are pivotal in dental pain pathways, making them promising targets for novel analgesic interventions. Leveraging graph neural networks (GNNs) presents an innovative approach to model graph data, aiding in the identification of drug targets and prediction of their efficacy, complementing advancements in genomics and proteomics for therapeutic development. In this study, 921 drug-gene interactions involving P2X receptors were accessed through https://www.probes-drugs.org/. These interactions underwent meticulous annotation, preprocessing, and subsequent utilization to train and assess GNNs. Furthermore, leveraging Cytoscape, the CytoHubba plugin, and other bioinformatics tools, gene expression networks were constructed to pinpoint hub genes within these interactions. Through analysis, SLC6A3, SLC6A2, FGF1, GRK2, and PLA2G2A were identified as central hub genes within the context of P2X receptor-mediated drug-gene interactions. Despite achieving a 65 percent accuracy rate, the GNN model demonstrated suboptimal predictive power for gene-drug interactions associated with oral pain. Hence, further refinements and enhancements are imperative to unlock its full potential in elucidating and targeting pathways underlying oral pain mechanisms.

15.
BMC Oral Health ; 24(1): 458, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38622548

RESUMEN

BACKGROUND: Various methods, chemical and physical, disinfect dental impressions. Common chemicals include 1% Sodium Hypochlorite and 2% glutaraldehyde, while UV radiation is a prevalent physical method. Few studies compare their effects on dimensional stability in polyether impressions. This study aims to assess such stability using different disinfection methods. Therefore, this study was planned to evaluate the dimensional stability of polyether impression material using different disinfection methods. METHODS: This in vitro study compared the effects of chemical disinfectants (1% Sodium Hypochlorite and 2% glutaraldehyde) and UV irradiation on the dimensional stability of polyether impression material. Groups A, B, C, and D, each with ten samples (N = 10), were studied. Group A was untreated (control). Group B was treated with 2% glutaraldehyde for 20 min, Group C with 1% Sodium Hypochlorite for 20 min, and Group D with UV rays for 20 min. A pilot milling machine drill was used to make four parallel holes labeled A, B, C, and D in the anterior and premolar regions from right to left. After sequential drilling, four implant analogs were positioned using a surveyor for accuracy. Ten open-tray polyether impressions were made and treated as described in the groups, followed by pouring the corresponding casts. Distortion values for each disinfection method were measured using a coordinate measuring machine capable of recording on the X- and Y-axes. RESULTS: A comprehensive analysis was conducted using the one-way ANOVA test for distinct groups labeled A, B, C, and D, revealing significant differences in the mean distances for X1, X2, X4, X5, and X6 among the groups, with p-values ranging from 0.001 to 0.000. However, no significant differences were observed in X3. Notably, mean distances for the Y variables exhibited substantial differences among the groups, emphasizing parameter variations, with p-values ranging from 0.000 to 0.033. The results compared the four groups using the one-way ANOVA test, revealing statistically significant distance differences for most X and Y variables, except for X3 and Y4. Similarly, post-hoc Tukey's tests provided specific pairwise comparisons, underlining the distinctions between group C and the others in the mean and deviation distances for various variables on both the X- and Y-axes. CONCLUSIONS: This study found that disinfection with 1% sodium hypochlorite or UV rays for 20 min maintained dimensional stability in polyether impressions.


Asunto(s)
Desinfectantes , Desinfección , Humanos , Desinfección/métodos , Glutaral , Hipoclorito de Sodio , Materiales de Impresión Dental , Técnica de Impresión Dental
16.
PLoS One ; 19(4): e0301361, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38625957

RESUMEN

OBJECTIVES: The impression technique highly influences the adaptation of ceramic restorations. Not enough information is available to compare the marginal (MF) and internal fit (IF) of endocrowns fabricated with various digitization techniques. Therefore, this in-vitro study aimed to compare the MF and IF of lithium disilicate (LDS) endocrowns fabricated through direct and indirect digital scanning methods. MATERIALS AND METHODS: One extracted maxillary molar was used to fabricate endocrowns. The digitization of the model was performed with (G1) direct scanning (n = 10) utilizing an intraoral scanner (IOS), (G2) indirectly scanning the conventional impression taken from the model using the same IOS (n = 10), (G3) indirectly digitalizing the obtained impression using an extraoral scanner (EOS) (n = 10), and (G4) scanning the poured cast using the same EOS (n = 10). The MF and IF of the endocrowns were measured using the replica method and a digital stereomicroscope. The Kruskal-Wallis test was used to analyze data. RESULTS: The studied groups differed significantly (p<0.001). G2 (130.31±7.87 µm) and G3 (48.43±19.14 µm) showed the largest and smallest mean vertical marginal gap, respectively. G2 and G3 led to the highest and lowest internal gaps in all regions, respectively. With significant differences among the internal regions (p<0.001), the pulpal area demonstrated the most considerable misfit in all groups. CONCLUSIONS: Scanning the impression using an extraoral scanner showed smaller marginal and internal gaps.


Asunto(s)
Diseño Asistido por Computadora , Porcelana Dental , Cerámica , Diente Molar , Diseño de Prótesis Dental , Técnica de Impresión Dental
17.
PLoS One ; 19(3): e0300157, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38483856

RESUMEN

OBJECTIVE: The current body of research on utilizing botulinum toxin (BTX) to manage temporomandibular disorders (TMDs) has not yet yielded definitive conclusions. The primary objective of this study was to determine the effectiveness of BTX in pain reduction for TMDs compared to placebo and other treatments. The secondary outcomes evaluated were adverse events, maximum mouth opening, bruxism events, and maximum occlusal force. MATERIALS AND METHODS: A literature search was performed on PubMed, Dimension Publication, Scopus, and Google Scholar. The RoB 2 tool was used for quality assessment. The mean differences in pain scores were estimated to measure the effect of BTX on pain reduction. For adverse events, the risk ratio for the incidence of side effects was calculated. RESULTS: Two hundred and sixty non-duplicate articles were identified; however, only 14 RCTS were included in this review. The total study population included 395 patients. The overall risk of bias showed a low to moderate quality of evidence. Results from 6 studies were reported only narratively; four studies were used for meta-analysis on pain reduction, and five were used for meta-analysis on adverse events. The control used in the meta-analysis was placebo injections. Results of the meta-analysis for pain reduction were statistically insignificant for the BTX group with mean differences at MD = -1.71 (95% CI, -2.87 to -0.5) at one month, -1.53 (95% CI, -2.80 to -0.27) at three months, and -1.33 (95% CI, -2.74 to 0.77) at six months. This showed that BTX treatment was not significantly better than placebo for a reduction in pain scores at 1, 3, and 6 months. Regarding safety, the placebo group showed a relative risk of 1.34 (95%CI, 0.48-6.78) and 1.17 (95%CI, 0.54-3.88) at 1 and 3 months respectively. However, the risks were not statistically significant. There was also no difference in the effectiveness of BTX compared to placebo and other treatments for maximum mouth opening, bruxism events, and maximum occlusal force. CONCLUSION: BTX was not associated with better outcomes in terms of pain reduction, adverse events, maximum mouth opening, bruxism events, and maximum occlusal force. More high-quality RCTs are needed to better understand this topic.

18.
BMC Oral Health ; 24(1): 401, 2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38553673

RESUMEN

BACKGROUND: This study aimed to evaluate dentist perceptions of attractive smiles in the Pakistani population, considering different dental proportions. METHODS: Maxillary casts and digital images were used to create symmetrical representations of anterior teeth. dentists' preferences for good and bad teeth proportions, width/height ratios, and various dental proportions (golden, recurring esthetic dental (RED), golden percentage, Preston, and local/observed) were assessed using one sample and paired t-test. The Chi-square test was used to determine the gender disparities and factors affecting smile attractiveness. A p-value of ≤ 0.05 was taken as significant. RESULTS: The RED proportion emerged as the preferred choice for normal-sized teeth, with specialists and general dentists favoring it over the golden proportion. For tall teeth, the golden proportion was predominantly preferred. The golden percentage received limited preference for aesthetic smile construction. CONCLUSIONS: The smiles created using the principles of RED proportion were opted as the most attractive by local dentists. Factors such as tooth arrangement, color, and midline were highlighted as essential considerations in aesthetic smile construction.


Asunto(s)
Estética Dental , Incisivo , Humanos , Pakistán , Sonrisa , Maxilar , Recurrencia , Odontólogos
19.
BMC Oral Health ; 24(1): 366, 2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38515128

RESUMEN

BACKGROUND: The success of implants in the socket shield technique relies on stress experienced by root fragments within the socket. Although there is no consensus on optimal root fragment thickness, varying thicknesses and dynamic implant placement induce stress in various directions and degrees. This study aimed to assess biomechanical response and stress distribution across different root fragment thicknesses in the socket shield procedure. METHODS: This in vitro study was conducted to assess and compare the stress distribution on residual root structures of varying thicknesses positioned within the labial aspect of the maxillary incisor socket during immediate implant placement of standard dimensions. The procedure involved applying an insertional torque of 40 Ncm, and the analysis was conducted using finite element analysis software. RESULTS: Utilizing the Numerical Technique with Abaqus software for explicit dynamics, von Mises stress and principal strain were analyzed on the root structure and bone under nonlinear contact conditions during implant torque application. For Model A, a loading torque of 40 Ncm was applied vertically on the implant, along with a horizontal force of 20 N on the root structure and bone. Results indicated maximum stress of 12.68 MPa on the root structure with a thickness of 0.5 mm and 5.61 MPa on the bone, with principal strains of 6.82E-03 and 4.10E-03, respectively. In Model B, with a root structure thickness of 1.0 mm, the maximum stress increased to 19.70 MPa, while the bone stress rose to 9.51 MPa, with principal strains of 1.03E-02 and 6.09E-03. Model C, with a root structure thickness of 1.5 mm, exhibited a maximum stress of 21.58 MPa on the root and 10.12 MPa on the bone, with principal strains of 1.16E-02 and 6.10E-03. Lastly, in Model D, with a root structure thickness of 2.0 mm, the maximum stress on the root structure and bone escalated to 28.74 MPa and 11.38 MPa, respectively, with principal strains of 1.55E-02 and 8.31E-03. CONCLUSIONS: As the thickness of the shield increases (ranging from 0.5 to 2 mm) in socket shield procedures with immediate implant placement, both stress on the root fragment and bone and principal micro-strain escalate. However, employing a shield thickness within the range of 0.5 to 2 mm does not lead to any adverse stress generation on the residual root fragment. However, for enhanced safety, it is recommended to restrict the maximum diameter and extension of the root fragment to 1.5 mm when considering implant sizes and socket diameter for the socket shield technique.


Asunto(s)
Implantes Dentales de Diente Único , Implantes Dentales , Carga Inmediata del Implante Dental , Humanos , Análisis de Elementos Finitos , Alveolo Dental/cirugía , Análisis del Estrés Dental
20.
Psych J ; 2024 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-38363639

RESUMEN

Dental anxiety is a common problem encountered in dental clinics that affects both patients and dentists. Adequate management of dental anxiety is critical for optimal treatment outcomes for the patient. This study aims to assess the efficacy of two anxiety-reduction techniques (iatrosedation and music listening) for dental crown preparation in adult patients. In this clinical trial, 60 patients were randomly assigned to three groups: Group 1, iatrosedation; Group 2, music listening; and Group 3, control. Patients in all three groups underwent dental crown preparation. To measure the anxiety levels of the patients, heart rate was calculated using a pulse oximeter, and verbal rating scale scores were assessed. One-way analysis of variance, post hoc analysis, and Spearman's correlation were used to compare the mean values of the three groups. Significant differences were observed in the heart rate and verbal rating scale scores among individuals in the study groups. A more substantial reduction in anxiety levels was found in patients exposed to iatrosedation (Group 1), which was followed by music listening (Group 2). Recorded heart rate and verbal rating scores were the highest in the control group patients. The iatrosedation technique significantly reduced dental anxiety for patients undergoing dental crown treatment; however, music listening was less effective than iatrosedation. Educating patients regarding the dental care they are about to receive is vital for reducing their anxiety.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA