Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros




Base de datos
Asunto de la revista
Intervalo de año de publicación
1.
J Synchrotron Radiat ; 30(Pt 6): 1076-1085, 2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-37815374

RESUMEN

Microbeam radiation therapy (MRT) is a radiotherapy technique combining spatial fractionation of the dose distribution on a micrometric scale, X-rays in the 50-500 keV range and dose rates up to 16 × 103 Gy s-1. Nowadays, in vivo dosimetry remains a challenge due to the ultra-high radiation fluxes involved and the need for high-spatial-resolution detectors. The aim here was to develop a striped diamond portal detector enabling online microbeam monitoring during synchrotron MRT treatments. The detector, a 550 µm bulk monocrystalline diamond, is an eight-strip device, of height 3 mm, width 178 µm and with 60 µm spaced strips, surrounded by a guard ring. An eight-channel ASIC circuit for charge integration and digitization has been designed and tested. Characterization tests were performed at the ID17 biomedical beamline of the European Synchrotron Radiation Facility (ESRF). The detector measured direct and attenuated microbeams as well as interbeam fluxes with a precision level of 1%. Tests on phantoms (RW3 and anthropomorphic head phantoms) were performed and compared with simulations. Synchrotron radiation measurements were performed on an RW3 phantom for strips facing a microbeam and for strips facing an interbeam area. A 2% difference between experiments and simulations was found. In more complex geometries, a preliminary study showed that the absolute differences between simulated and recorded transmitted beams were within 2%. Obtained results showed the feasibility of performing MRT portal monitoring using a microstriped diamond detector. Online dosimetric measurements are currently ongoing during clinical veterinary trials at ESRF, and the next 153-strip detector prototype, covering the entire irradiation field, is being finalized at our institution.


Asunto(s)
Radiometría , Sincrotrones , Radiometría/métodos , Fraccionamiento de la Dosis de Radiación , Rayos X , Fantasmas de Imagen , Radioterapia , Método de Montecarlo , Diamante
2.
Sci Rep ; 12(1): 7788, 2022 May 12.
Artículo en Inglés | MEDLINE | ID: mdl-35552495

RESUMEN

Practical applications of heat transport control with artificial metamaterials will heavily depend on the realization of thermal diodes/rectifiers, in which thermal conductivity depends on the heat flux direction. Whereas various macroscale implementations have been made experimentally, nanoscales realizations remain challenging and efficient rectification still requires a better fundamental understanding of heat carriers' transport and nonlinear mechanisms. Here, we propose an experimental realization of a thermal rectifier based on two leads with asymmetric mass gradients separated by a ballistic spacer, as proposed in a recent numerical investigation, and measure its thermal properties electrically with the microbridge technique. We use a Si[Formula: see text]N[Formula: see text] nanobeam on which an asymmetric mass gradient has been engineered and demonstrate that in its current form, this structure does not allow for thermal rectification. We explain this by a combination of too weak asymmetry and non-linearities. Our experimental observations provide important information towards fabricating rigorous thermal rectifiers in the ballistic phonon transport regime, which are expected to open new possibilities for applications in thermal management and quantum thermal devices.

3.
Nano Lett ; 18(9): 5726-5730, 2018 09 12.
Artículo en Inglés | MEDLINE | ID: mdl-30068080

RESUMEN

Nanofluidics finds its root in the study of fluids and flows at the nanoscale. Flow rate is a quantity that is both central when dealing with flows and notoriously difficult to measure experimentally at the scale of an individual nanopore or nanochannel. We show in this letter that minute flow rate can be directly measured accumulating liquid over time within the compliant membrane of a commercial piezoresistive pressure sensor. Our flow rate sensor is versatile and can be operated independently of the nature of the liquid, flow profile, and type of nanochannel. We demonstrate this method by measuring the pressure-driven flow of silicon oil in a single nanochannel of average radius 200 nm. This approach gives reliable measurement of the flow rate up to 1 pL/min. Unlike other nanoscale flow measurements methods based, for instance, on particle tracking, our sensor delivers a direct voltage output suitable for nanoflow control applications.

4.
Appl Opt ; 52(26): 6620-5, 2013 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-24085141

RESUMEN

The optical transmission and reflection in between two metalized optical fiber tips is studied in the optical near-field and far-field domains. In addition to aluminum-coated tips for near-field scanning optical microscopy (NSOM), specifically developed gold-coated fiber tips cut by focused ion beam are investigated. Transverse transmission maps of subwavelength width clearly indicate optical near-field coupling between the tips for short tip distances and become essentially Gaussian-shaped for larger distances in the far-field regime. Moreover, concentric reflection fringes observed for NSOM-type tips illustrate the influence of the receiving fiber tip on the emission pattern of the source tip.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA