Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros




Base de datos
Asunto de la revista
Intervalo de año de publicación
1.
BMC Vet Res ; 20(1): 215, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38773537

RESUMEN

CONTEXT: Recently, prioritize has been given to using natural phytogenic or nano compounds as growth promoters and immunostimulants in fish diets as an alternative to antibiotics. AIMS: The main propose of this trial was to determine the impact of supplementing diets with spirulina or curcumin nanoparticles on the performance and health indicators of Nile tilapia fingerlings. METHODS: In a 56-day feeding trial, 180 tilapia fingerlings were assigned into three main groups, as follows: 1st, control group, 2nd, Spirulina platensis (SP; 5 g kg-1 diet) and 3rd, curcumin nanoparticles (CUR-NPs; 30 mg kg-1 diet). KEY RESULTS: Incorporating tilapia diets with SP or CUR-NPs significantly improved performance, body chemical analysis, blood biochemical and hematological indices, digestive enzyme activities, and antioxidant and immunostimulant features compared to the control. CONCLUSION: Fortified tilapia diets with CUR-NPs or SP efficiently boost the productivity and health of Nile tilapia fingerlings. IMPLICATIONS: The research introduces new practical solutions for applying safe feed additives as alternatives to antibiotics in tilapia farming.


Asunto(s)
Alimentación Animal , Antioxidantes , Cíclidos , Curcumina , Dieta , Suplementos Dietéticos , Nanopartículas , Spirulina , Animales , Curcumina/farmacología , Curcumina/administración & dosificación , Spirulina/química , Cíclidos/inmunología , Cíclidos/sangre , Alimentación Animal/análisis , Nanopartículas/administración & dosificación , Nanopartículas/química , Dieta/veterinaria , Antioxidantes/farmacología , Composición Corporal/efectos de los fármacos
2.
Innovations (Phila) ; 8(1): 56-66, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23571795

RESUMEN

OBJECTIVE: Ensuring the transmurality of the mitral isthmus lesion, a critical component of the cryomaze, entails mirror-image application of the cryoprobe both on endocardial and epicardial surfaces when carrying out ablation. Concerns of circumflex artery injury have been expressed during the epicardial application of the cryoprobe over the coronary sinus as the artery courses on the posterior surface of the sinus in the atrioventricular (AV) groove. The objective of this study was to analyze the incidence of significant injury to the circumflex artery and its impact on outcomes, if any, in those patients who have undergone cryomaze. METHODS: Between August 2004 and December 2009, a total of 223 patients underwent argon-based cryoablation (120-second application at -140°C). After Western Institutional Review Board approval, 20 consecutive patients with normal results of preoperative coronary angiograms (right dominance, 75%; left dominance, 15%; codominant circulation, 10%) and who were at least 6 months postablation were enrolled in this study. The mean ± SD age was 60.74 ± 14.99 years, 35% were men, and 50% belonged to New York Heart Association class III/IV. The mean ± SD atrial fibrillation duration was 23.83 ± 36.28 months (65% were paroxysmal). Ten percent (n = 2) underwent primary cryomaze, 40% (n = 8) underwent cryomaze plus mitral valve repair, and 50% (n = 10) underwent two or more concomitant valvular procedures. Twelve patients underwent biatrial cryomaze, and eight underwent only left-sided cryomaze. All patients underwent a 24-hour Holter monitoring, electrocardiogram stress test, and a coronary computed tomographic angiogram, as per the protocol of this study. RESULTS: At discharge, 85% had normal sinus rhythm, whereas 15% of the patients were paced. On a mean ± SD follow-up at 32.57 ± 19.51 months, the Holter and/or pacemaker interrogation revealed AV synchrony in all patients-16 in sinus rhythm and 4 with heart block who converted to AV synchrony after subsequent pacemaker implantation. The stress test was available for 18 patients, and its results were negative in all of them. On the computed tomographic angiogram, 95% of the patients had a completely patent circumflex artery. Stenosis was noticed in only one patient (right dominant circulation), with a 30% to 40% tubular stenosis of the circumflex artery. However, this lesion corresponded to the P1 area of the mitral annulus and was significantly proximal on the circumflex to the P3 area, where the cryoprobe was applied during the cryomaze procedure. CONCLUSIONS: Barring one case of partial circumflex stenosis, likely due to the ongoing normal progression of coronary artery disease, these data derived from a limited prospective trial suggest that epicardial application during the cryomaze procedure does not cause anatomic or physiological compromise of the circumflex artery. Nevertheless, laboratory and anecdotal evidence exist that conflict with this conclusion, and caution should be exercised when applying cryothermy in the vicinity of coronary arteries.


Asunto(s)
Fibrilación Atrial/cirugía , Estenosis Coronaria/etiología , Vasos Coronarios/lesiones , Criocirugía/efectos adversos , Anciano , Fibrilación Atrial/diagnóstico , Estudios de Cohortes , Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/epidemiología , Vasos Coronarios/diagnóstico por imagen , Criocirugía/métodos , Electrocardiografía Ambulatoria , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos/efectos adversos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Seguridad del Paciente , Cuidados Posoperatorios/métodos , Complicaciones Posoperatorias/diagnóstico , Estudios Retrospectivos , Medición de Riesgo , Índice de Severidad de la Enfermedad , Tomografía Computarizada por Rayos X/métodos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA