Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Plast Reconstr Surg ; 153(3): 619-622, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-37159902

RESUMEN

SUMMARY: Rhinoplasty is a challenging procedure with a steep learning curve. Surgical simulators provide a safe platform to gain hands-on experience without compromising patient outcomes. Therefore, rhinoplasty is an ideal procedure to benefit from an effective surgical simulator. A high-fidelity rhinoplasty simulator was developed using three-dimensional computer modeling, three-dimensional printing, and polymer techniques. The simulator was tested by six surgeons with experience in rhinoplasty to assess realism, anatomic accuracy, and value as a training tool. The surgeons performed common rhinoplasty techniques and were provided a Likert-type questionnaire assessing the anatomic features of the simulator. A variety of surgical techniques were performed successfully using the simulator, including open and closed approaches. Bony techniques performed included endonasal osteotomies and rasping. Submucous resection with harvest of septal cartilage, cephalic trim, and tip suturing, as well as grafting techniques including alar rim, columellar strut, spreader, and shield grafts, were performed successfully. Overall, there was agreement on the simulator's anatomic accuracy of bony and soft-tissue features. There was strong agreement on the simulator's overall realism and value as a training tool. The simulator provides a high-fidelity, comprehensive training platform to learn rhinoplasty techniques to augment real operating experience without compromising patient outcomes.


Asunto(s)
Rinoplastia , Humanos , Rinoplastia/métodos , Tabique Nasal/cirugía , Cartílago/trasplante , Encuestas y Cuestionarios , Impresión Tridimensional
2.
Plast Reconstr Surg Glob Open ; 10(11): e4656, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36348749

RESUMEN

Concomitant with such a shift toward competency-based curricula, there has been increasing adoption of surgical simulation coupled with virtual, mixed, and augmented reality. These technologies have become more commonplace across multiple surgical disciplines, in domains such as preoperative planning, surgical education, and intraoperative navigation. However, there is a relative paucity of literature pertaining to the application of this technology to plastic surgery education. This review outlines the advantages of mixed and augmented reality in the pursuit of an ideal simulation environment, their benefits for the education of plastic surgery trainees, and their role in standardized assessments. In addition, we offer practical solutions to commonly encountered problems with this technology. Augmented reality has tremendous untapped potential in the next phase of plastic surgery education, and we outline steps toward broader implementation to enhance the learning environment for our trainees and to improve patient outcomes.

3.
Plast Reconstr Surg ; 148(6): 1335-1346, 2021 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-34847122

RESUMEN

BACKGROUND: Passive orthodontic appliances and gingivosupraperiosteoplasty are adjuncts that can be used by surgeons at the time of primary cleft lip repair. These treatments, along with the surgical technique of cleft lip and palate repair, may impact midface growth. The objective of this study was to describe the authors' protocol for unilateral and bilateral cleft lip repair and to evaluate midfacial growth in a cohort of patients at mixed dentition who had undergone presurgical passive orthodontic appliance therapy and gingivosupraperiosteoplasty at the time of unilateral and bilateral cleft lip repair. METHODS: Fifteen complete unilateral and 15 complete bilateral cleft lip and palate patients underwent passive orthodontic appliance treatment and primary lip repair with gingivosupraperiosteoplasty. Lateral cephalograms were analyzed by three blinded reviewers. Mean cephalometric measurements at mixed dentition were compared to cephalometric values for noncleft patients, unilateral cleft lip and palate patients who did not undergo gingivoperiosteoplasty or presurgical treatment, and unilateral cleft lip and palate patients who underwent gingivoperiosteoplasty/nasoalveolar molding with independent samples t tests. RESULTS: Mean cephalometric values were within age-specific normal values for sella-nasion-A point, sella-nasion-B point, A point-nasion-B point, and facial axis. Eighty-seven (13/15) percent of unilateral cleft lip and palate patients and 93 percent (14/15) of bilateral cleft lip and palate patients did not exhibit skeletal class III malocclusion. There was no significant difference between cephalometric values for our patients and patients who did not receive gingivosupraperiosteoplasty or presurgical treatment or who underwent the gingivoperiosteoplasty/nasoalveolar molding protocol. CONCLUSIONS: Presurgical passive orthodontic appliances, combined with gingivosupraperiosteoplasty at the time of lip repair, leads to normal maxillary development in most patients at mixed dentition. Assessment of midface growth at skeletal maturity is required. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, IV.


Asunto(s)
Labio Leporino/terapia , Fisura del Paladar/cirugía , Gingivoplastia/métodos , Desarrollo Maxilofacial , Obturadores Palatinos , Cefalometría , Labio Leporino/complicaciones , Fisura del Paladar/complicaciones , Dentición Mixta , Cara/anatomía & histología , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Maxilar/crecimiento & desarrollo , Maxilar/cirugía , Aparatos Ortodóncicos , Periostio/cirugía , Resultado del Tratamiento
4.
Hand (N Y) ; 15(1): 23-26, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-30003815

RESUMEN

Background: Scapholunate advanced collapse (SLAC) is the most common pattern of wrist arthritis. Sparse data exist regarding the SLAC wrist pattern of arthritis. This study aimed to document the epidemiology of advanced SLAC in terms of patients' sociodemographics and possible association with trauma. Methods: Sixty-one patients with severe SLAC wrist were included. Baseline sociodemographic characteristics were reviewed. To evaluate the relationship to injury, this group of cases was compared with a control group of 61 patients with first carpometacarpal osteoarthritis (CMC OA). The following data were collected for both groups: age, gender, history of traumatic injury, history of manual labor, duration of symptoms, and dominant hand involvement. Pearson chi-square tests for categorical variables and independent samples t test for continuous variables were performed to determine differences between groups. Results: Patients with SLAC wrist were more likely to be male (80.3% vs 31.1%; p<0.001), have a history of a traumatic injury (69.5% vs 25.9%, P < .001), have longer symptom duration (10.3 ± 13.3 vs 3.5 ± 2.5 years, P = .001), be involved in a manual labor job (49.0% vs 20.0%, P = .002), and be younger (53.1 ± 10.4 vs 58.3 ± 9.8; P = .006) compared with patients with CMC OA. There was no difference in dominant hand involvement (49.2% vs 53.3%; P = .571) between the groups. Conclusions: This study identified the characteristics of patients with advanced SLAC wrist. Compared with a control cohort of CMC OA, patients with SLAC wrist were more likely to be male, have a history of a traumatic injury, and be younger.


Asunto(s)
Artritis/epidemiología , Artrodesis/estadística & datos numéricos , Hueso Semilunar/patología , Hueso Escafoides/patología , Traumatismos de la Muñeca/epidemiología , Artritis/etiología , Estudios de Casos y Controles , Femenino , Humanos , Hueso Semilunar/lesiones , Hueso Semilunar/cirugía , Masculino , Persona de Mediana Edad , Osteoartritis/epidemiología , Osteoartritis/etiología , Osteoartritis/cirugía , Hueso Escafoides/lesiones , Hueso Escafoides/cirugía , Traumatismos de la Muñeca/complicaciones , Traumatismos de la Muñeca/cirugía , Articulación de la Muñeca/patología , Articulación de la Muñeca/cirugía
5.
Clin Plast Surg ; 45(1): 83-91, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29080663

RESUMEN

This article reviews the indications and controversies in abdominally based autologous breast reconstruction. The evidence regarding these indications and controversies will be appraised and summarized. Finally, we will provide a summary of our approach and technique for the patient undergoing autologous breast reconstruction using abdominally based free flaps.


Asunto(s)
Músculos Abdominales , Colgajos Tisulares Libres , Mamoplastia/métodos , Neoplasias de la Mama/cirugía , Femenino , Humanos , Mamoplastia/efectos adversos , Mastectomía , Selección de Paciente
6.
Aesthet Surg J ; 38(6): 616-622, 2018 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-29272355

RESUMEN

BACKGROUND: Outcomes in aesthetic breast surgery are dependent on preoperative breast measurements. The accuracy of 3-dimensional (3D) imaging in measuring critical landmarks in augmentation mammaplasty surgery has not been described. OBJECTIVES: We aimed to determine the predictability of 3D imaging compared to direct measurements. METHODS: Two raters measured the breasts of 28 women using four anthropometric (direct) measurements: sternal notch to nipple distance (Sn-N), nipple to midline (N-M), nipple to inframammary-fold distance under maximal stretch (N-IMF), and base width (BW). Measurements (indirect) were also obtained using 3D imaging. Statistical analysis was completed with Bland-Altman plots. RESULTS: Each rater collected 56 data points for each of the four measurements. This resulted in 224 data points per rater. The Sn-N measurement had a 0.05 cm (SD, 0.65) difference in the mean values obtained between direct and indirect measurements. N-M had a mean difference of 0.20 cm (SD, 0.62). The mean difference for BW was 1.26 cm (SD, 0.69 cm), and N-IMF showed a mean difference of 1.22 cm (SD, 0.74 cm). Three-dimensional imaging overestimated Sn-N, N-M, and BW, while it underestimated N-IMF. CONCLUSIONS: Three-dimensional imaging has good utility and is most accurate for Sn-N and N-M measurements, which require frontal imaging of a standing patient. BW and N-IMF are less accurate due to obscured landmarks on frontal imaging. The medial and lateral aspects of the breast may be obscured when measuring BW on 3D imaging, which may explain this difference. N-IMF is a dynamic measurement, and as a result, 3D imaging has limited ability to measure this distance accurately.


Asunto(s)
Antropometría/métodos , Mama/diagnóstico por imagen , Imagenología Tridimensional/métodos , Mamoplastia/métodos , Adulto , Mama/anatomía & histología , Mama/cirugía , Estética , Estudios de Factibilidad , Femenino , Humanos , Planificación de Atención al Paciente , Periodo Preoperatorio , Adulto Joven
7.
J Craniofac Surg ; 28(5): 1179-1184, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28538065

RESUMEN

Squamosal suture craniosynostosis is thought to be a relatively rare entity. In the authors' experience, it is underreported in imaging examinations and the existing literature. The authors sought to determine the incidence of squamosal synostosis, whether it is increasing in frequency, and its relationship with synostosis of the major calvarial sutures.Patients undergoing computed tomography imaging for suspected craniosynostosis over a 15-year period were reviewed by a plastic surgeon and pediatric neuroradiologist. Patients with synostosis of the squamosal sutures were identified and involvement of additional sutures, gender, and the presence of a known syndromic diagnosis were recorded. Patients greater than 4 years of age or those with prior craniofacial surgery were excluded.One hundred twenty-five patients met inclusion criteria, 26 of whom had squamosal suture synostosis (26/125, 20.8%). Squamosal synostosis was found in isolation in 3 patients (3/26, 11.5%), with 1 additional major suture in 10 patients (10/26, 38.5%), and ≥2 major sutures in 13 patients (13/26, 50%). Squamosal synostosis was more common in patients with a syndromic diagnosis (11/26 syndromic, 15/99 nonsyndromic, P < 0.001). Eleven of 26 patients with squamosal synostosis were identified in the radiology report (42.3%).Craniosynostosis of the squamosal suture is much more common than previously reported and can contribute to abnormal head shape in isolation, or in combination with major sutures. Squamosal suture synostosis is underdiagnosed clinically and radiologically, although insufficient evidence exists to determine if its true incidence is increasing.


Asunto(s)
Suturas Craneales/cirugía , Craneosinostosis/epidemiología , Craneosinostosis/cirugía , Plagiocefalia/cirugía , Preescolar , Suturas Craneales/diagnóstico por imagen , Craneosinostosis/diagnóstico por imagen , Estudios Transversales , Femenino , Humanos , Incidencia , Lactante , Masculino , Plagiocefalia/diagnóstico por imagen , Plagiocefalia/epidemiología , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
8.
Aesthet Surg J ; 36(4): 431-7, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26647138

RESUMEN

BACKGROUND: Patient outcomes in aesthetic breast surgery are highly dependent on breast measurements used in preoperative planning. OBJECTIVES: The purpose of this study is to determine the reliability of anthropometric breast measurements. METHODS: Four raters measured 28 women using 7 measurements: sternal notch to nipple distance (Sn-N), nipple to midline (N-M), nipple to inframammary-fold distance under maximal stretch (N-IMF), breast base width (BW), soft tissue pinch thickness of the upper pole (STPT:UP), STPT at the inframammary fold (STPT:IMF), and anterior pull skin stretch (APSS). Reliability was assessed using intra-class correlation coefficients (ICCs). RESULTS: Inter-rater reliability was excellent for Sn-N, N-M, and BW (ICC = 0.94, 0.90, and 0.76, respectively) and was good for N-IMF (ICC = 0.70). The STPT:UP, STPT:IMF, and APSS measurements were not reliable between raters (ICC < 0.2). Intra-rater reliability was excellent for Sn-N, N-M, and BW for all raters (all ICC > 0.75). The N-IMF intra-rater reliability was excellent in senior raters (ICC > 0.75) and good in junior raters (ICC > 0.6). The STPT:UP, STPT:IMF, and APSS measurements showed fair or poor reliability for most raters (ICC < 0.6). CONCLUSIONS: The Sn-N, N-M, and BW measurements are very reliable. Dynamic measurements including APSS, STPT:UP, and STUP:IMF are unreliable. N-IMF is the only reliable dynamic measurement, and its reliability improves with increasing clinical experience. The variable reliability of preoperative measurements must be considered in the planning of aesthetic breast surgery. LEVEL OF EVIDENCE: 4 Diagnostic.


Asunto(s)
Antropometría/métodos , Mama/anatomía & histología , Cuidados Preoperatorios , Adolescente , Adulto , Puntos Anatómicos de Referencia , Mama/cirugía , Técnicas Cosméticas , Estética , Femenino , Humanos , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Procedimientos de Cirugía Plástica , Reproducibilidad de los Resultados , Adulto Joven
9.
J Plast Reconstr Aesthet Surg ; 66(11): 1449-55, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23867239

RESUMEN

BACKGROUND: In vascularized composite allotransplantation, multiple types of tissue are transferred from donor to recipient as a single functional unit. This technique has been performed for upper extremity, face, and abdominal wall transplants, among many others. OBJECTIVE: To review the existing cases of face and upper extremity vascularized composite allotransplantation performed to date and to describe the functional outcomes and challenges associated with this new procedure. We also review the immune suppression protocols required for these procedures. METHODS: A literature review was performed using PubMed and online registries where available to identify patients who have undergone upper extremity and face transplant procedures. These were compiled and cross-referenced to abstracts, conference presentations, and press releases in the media to create a list of procedures performed to date. RESULTS: More than seventy patients have undergone upper extremity transplantation with very good functional outcomes routinely achieved. Twenty-five face transplants were identified that have been completed to date and details regarding patient outcome are included. One cases of human face allotransplantation with pre- and post-operative images is included as an example of what can be achieved with this technique. CONCLUSIONS: Vascularized composite allotransplantation is an emerging field that provides an exciting new avenue for reconstructive procedures and achieves functional and cosmetic outcomes not previously possible with existing techniques. However, it is not without its challenges and considerable work is still required prior to widespread adoption of these new reconstructive techniques.


Asunto(s)
Trasplante Facial , Trasplante de Mano , Terapia de Inmunosupresión , Trasplante Facial/efectos adversos , Trasplante de Mano/efectos adversos , Humanos , Terapia de Inmunosupresión/efectos adversos , Trasplante Homólogo
10.
Radiology ; 250(3): 867-77, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19244051

RESUMEN

PURPOSE: To determine whether admission computed tomography (CT) perfusion-derived permeability-surface area product (PS) maps differ between patients with hemorrhagic acute stroke and those with nonhemorrhagic acute stroke. MATERIALS AND METHODS: This prospective study was institutional review board approved, and all participants gave written informed consent. Forty-one patients who presented with acute stroke within 3 hours after stroke symptom onset underwent two-phase CT perfusion imaging, which enabled PS measurement. Patients were assigned to groups according to whether they had hemorrhage transformation (HT) at follow-up magnetic resonance (MR) imaging and CT and/or whether they received tissue plasminogen activator (TPA) treatment. Clinical, demographic, and CT perfusion variables were compared between the HT and non-HT patient groups. Associations between PS and HT were tested at univariate and multivariate logistic regression analyses and receiver operating characteristic (ROC) analysis. RESULTS: HT developed in 23 (56%) patients. Patients with HT had higher National Institutes of Health Stroke Scale (NIHSS) scores (P = .005), poorer outcomes (P = .001), and a higher likelihood of having received TPA (P = .005) compared with patients without HT. Baseline blood flow (P = .17) and blood volume (P = .11) defects and extent of flow reduction (P = .27) were comparable between the two groups. The mean PS for the HT group, 0.49 mL x min(-1) x (100 g)(-1), was significantly higher than that for the non-HT group, 0.09 mL x min(-1) x (100 g)(-1) (P < .0001). PS (odds ratio, 3.5; 95% confidence interval [CI]: 1.69, 7.06; P = .0007) and size of hypoattenuating area at nonenhanced admission CT (odds ratio, 0.4; 95% CI: 0.2, 0.7; P = .002) were the only independent variables associated with HT at stepwise multivariate analysis. The mean area under the ROC curve was 0.918 (95% CI: 0.828, 1.00). The PS threshold of 0.23 mL x min(-1) x (100 g)(-1) had 77% sensitivity and 94% specificity for detection of HT. CONCLUSION: Admission PS measurement appears promising for distinguishing patients with acute stroke who are likely from those who are not likely to develop HT. SUPPLEMENTAL MATERIAL: http://radiology.rsnajnls.org/cgi/content/full/250/3/867/DC1.


Asunto(s)
Isquemia Encefálica/complicaciones , Isquemia Encefálica/diagnóstico por imagen , Hemorragias Intracraneales/diagnóstico por imagen , Hemorragias Intracraneales/etiología , Accidente Cerebrovascular/complicaciones , Accidente Cerebrovascular/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Anciano , Angiografía Cerebral/métodos , Femenino , Humanos , Masculino , Perfusión/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
11.
Radiology ; 247(3): 818-25, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18424687

RESUMEN

PURPOSE: To prospectively determine the parameters derived at admission computed tomographic (CT) perfusion imaging admission that best differentiate ischemic white matter that recovers from that which infarcts, with the latter retrospectively defined at a CT examination performed without contrast material (unenhanced CT) 5-7 days after the event. MATERIALS AND METHODS: Ethics committee approval and informed consent were obtained. Thirty patients with stroke underwent unenhanced CT, CT angiography, and CT perfusion studies at admission. Additionally, CT angiography was performed 24 hours after the stroke, and an unenhanced CT study was performed 5-7 days after the stroke. Five patients were excluded; the remaining patients (10 men, 15 women; mean age, 70 years +/- 13 [standard deviation]) were separated into those with recanalization (n = 16) and those without recanalization (n = 9) at 24 hours. For patients with recanalization, the final infarct was outlined on unenhanced CT images obtained 5-7 days after the event and was superimposed on coregistered maps from the CT perfusion study performed at admission. Ischemic white matter tissue (cerebral blood flow [CBF] < 14 mL/min/100 g) was identified at the admission CT perfusion study, and the penumbra was defined as the difference between the ischemic region and the infarct region. RESULTS: Infarct regions showed a matched decrease in CBF and cerebral blood volume (CBV) at admission, whereas penumbra regions showed a significant (P < .05) decrease in CBF but no change in CBV (P > .05) from contralateral values. A threshold CBF . CBV value of 8.14 was the most sensitive (95%, 20 of 21 regions) and specific (94%, 32 of 34 regions) parameter for differentiating between regions of ischemic white matter that recovered and regions of ischemic white matter that infarcted. CONCLUSION: The product of CBF and CBV derived from CT perfusion data provided the best differentiation between regions of ischemic white matter that infarcted and regions of ischemic white matter that recovered 5-7 days after a stroke.


Asunto(s)
Isquemia Encefálica/diagnóstico por imagen , Accidente Cerebrovascular/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Adulto , Anciano , Anciano de 80 o más Años , Velocidad del Flujo Sanguíneo , Volumen Sanguíneo , Isquemia Encefálica/fisiopatología , Angiografía Cerebral , Circulación Cerebrovascular , Medios de Contraste , Femenino , Humanos , Yohexol , Modelos Logísticos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Interpretación de Imagen Radiográfica Asistida por Computador , Estudios Retrospectivos , Sensibilidad y Especificidad , Accidente Cerebrovascular/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA