Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Transl Vis Sci Technol ; 13(8): 11, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39110574

RESUMEN

Purpose: To predict 10-2 Humphrey visual fields (VFs) from 24-2 VFs and associated non-total deviation features using deep learning. Methods: We included 5189 reliable 24-2 and 10-2 VF pairs from 2236 patients, and 28,409 reliable pairs of macular OCT scans and 24-2 VF from 19,527 eyes of 11,560 patients. We developed a transformer-based deep learning model using 52 total deviation values and nine VF test features to predict 68 10-2 total deviation values. The mean absolute error, root mean square error, and the R2 were evaluation metrics. We further evaluated whether the predicted 10-2 VFs can improve the structure-function relationship between macular thinning and paracentral VF loss in glaucoma. Results: The average mean absolute error and R2 for 68 10-2 VF test points were 3.30 ± 0.52 dB and 0.70 ± 0.11, respectively. The accuracy was lower in the inferior temporal region. The model placed greater emphasis on 24-2 VF points near the central fixation point when predicting the 10-2 VFs. The inclusion of nine VF test features improved the mean absolute error and R2 up to 0.17 ± 0.06 dB and 0.01 ± 0.01, respectively. Age was the most important 24-2 VF test parameter for 10-2 VF prediction. The predicted 10-2 VFs achieved an improved structure-function relationship between macular thinning and paracentral VF loss, with the R2 at the central 4, 12, and 16 locations of 24-2 VFs increased by 0.04, 0.05 and 0.05, respectively (P < 0.001). Conclusions: The 10-2 VFs may be predicted from 24-2 data. Translational Relevance: The predicted 10-2 VF has the potential to improve glaucoma diagnosis.


Asunto(s)
Aprendizaje Profundo , Glaucoma , Tomografía de Coherencia Óptica , Pruebas del Campo Visual , Campos Visuales , Humanos , Pruebas del Campo Visual/métodos , Campos Visuales/fisiología , Femenino , Masculino , Persona de Mediana Edad , Glaucoma/fisiopatología , Glaucoma/diagnóstico , Tomografía de Coherencia Óptica/métodos , Anciano , Adulto , Trastornos de la Visión/fisiopatología , Trastornos de la Visión/diagnóstico
2.
Int Ophthalmol ; 44(1): 260, 2024 Jun 23.
Artículo en Inglés | MEDLINE | ID: mdl-38910200

RESUMEN

PURPOSE: To evaluate factors associated with differences in intraocular pressure (IOP) readings between iCare and Goldmann applanation tonometry (GAT) in established glaucoma patients. METHODS: This retrospective comparative study included clinical data of 350 eyes from 350 established glaucoma patients who had iCare and GAT IOP measured by an ophthalmic technician and a glaucoma specialist, respectively. The main outcome measure was the difference in IOP measurements of the right eyes with iCare and GAT. RESULTS: The intraclass correlation coefficient (ICC) between GAT and iCare was 0.90. The mean IOP difference between tonometers was - 0.18 ± 2.89 mmHg. Bland-Altman plots indicated a 95% limit of agreement of - 5.8 to 5.5 mmHg. Central corneal thickness (CCT) and age were significantly correlated with the difference in IOPs of the iCare and GAT. GAT-IOP and age were significantly associated with the absolute difference in measured IOP of the two tonometers. The difference in measurements was not significantly associated with prior glaucoma surgery, average global index of optical coherence tomography, axial length, technician years of experience and certification, and IOP range. CONCLUSION: Although there is good agreement between the iCare and GAT mean values, these devices are not interchangeable in glaucoma patients due to the wide range of the limit of agreement.


Asunto(s)
COVID-19 , Glaucoma , Presión Intraocular , Tonometría Ocular , Humanos , Estudios Retrospectivos , Tonometría Ocular/instrumentación , Masculino , Femenino , Presión Intraocular/fisiología , COVID-19/epidemiología , COVID-19/diagnóstico , Anciano , Persona de Mediana Edad , Glaucoma/diagnóstico , Glaucoma/fisiopatología , SARS-CoV-2 , Adulto , Reproducibilidad de los Resultados , Anciano de 80 o más Años , Pandemias
3.
Eur J Ophthalmol ; : 11206721241237305, 2024 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-38470322

RESUMEN

PURPOSE: To compare the intraocular pressure (IOP) profile and the incidence of IOP spikes following selective laser trabeculoplasty (SLT) between pigmentary glaucoma (PG) and primary open-angle glaucoma (POAG). MATERIALS AND METHODS: Retrospective comparative study of 65 PG eyes of 51 patients matched with 65 POAG eyes of 65 patients who received SLT. Matching was done based on age, gender, glaucoma severity, pre-laser IOP, and number of medications. Post-SLT IOP spike was defined as IOP elevation ≥5mmHg, 30-45 min after the laser. RESULTS: In PG and POAG groups, the average age was 62.33 ± 9.18 and 62.58 ± 9.19 years (p = 0.95). The glaucoma severity (p = 0.708), baseline IOP (PG = 21.61 ± 1.34mmHg vs. POAG = 21.13 ± 5.09mmHg, p = 0.943), and number of topical glaucoma medications(PG = 2.34 ± 1.34 vs. POAG = 2.1 ± 1.41, p = 0.342) were comparable. More PG patients were on oral acetazolamide (PG = 26.15% vs. POAG = 1.5%, p < 0.001). Average logMAR visual acuity was significantly higher in the POAG group (0.207 ± 0.3 vs. 0.192 ± 0.37, p = 0.012). Eyes with PG received lower laser energy (POAG = 63.65 ± 22.03 mJ vs. PG = 43.71 ± 25.68 mJ, p < 0.001). IOP spikes were recorded in 5 PG eyes (7.6%) and none in the POAG group (p = 0.058). Failure rates were similar (PG = 50.7% and POAG = 43.1%, p = 0.205). In multivariable analysis, only pre-laser IOP (coefficient = 2.154 [CI: 0.765-3.543], p = 0.003) was a significant predictor of IOP change percentage after 12 months. CONCLUSIONS: SLT was comparably effective in both PG and POAG. IOP spikes were observed only in the PG group, though the total laser energy was lower in this group compared with POAG.

4.
Curr Opin Ophthalmol ; 35(3): 225-231, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38484223

RESUMEN

PURPOSE OF REVIEW: The field of corneal biomechanics has rapidly progressed in recent years, reflecting technological advances and an increased understanding of the clinical significance of measuring these properties. This review will evaluate in-vivo biomechanical properties obtained by current technologies and compare them regarding their relevance to established biomechanical properties obtained by gold-standard ex-vivo techniques normally conducted on elastic materials. RECENT FINDINGS: Several new technologies have appeared in recent years, including vibrational optical coherence tomography (VOCT) and the corneal indentation device (CID). These techniques provide promising new opportunities for minimally invasive and accurate measurements of corneal viscoelastic properties. SUMMARY: Alterations in corneal biomechanics are known to occur in several corneal degenerative diseases and after refractive surgical procedures. The measurement of corneal biomechanical properties has the capability to diagnose early disease and monitor corneal disease progression. Several new technologies have emerged in recent years, allowing for more accurate and less invasive measurements of corneal biomechanical properties, most notably the elastic modulus.


Asunto(s)
Enfermedades de la Córnea , Procedimientos Quirúrgicos Refractivos , Humanos , Fenómenos Biomecánicos , Córnea/cirugía , Tomografía de Coherencia Óptica , Enfermedades de la Córnea/cirugía
5.
J Ophthalmol ; 2024: 6624021, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38304290

RESUMEN

Background: This retrospective review reports on patients who underwent glaucoma drainage implant (GDI) surgery and had baseline intraocular pressure (IOP) of ≤18 mmHg with at least one year of follow-up. Methods: Clinical data of 67 eyes of 67 patients were collected from patients' charts, and the outcomes of GDI were evaluated until 7 years. GDI failure was defined as IOP reduction of less than 20% from the baseline at two consecutive visits three months after surgery, decline to no light perception, or if additional glaucoma surgery was performed. Results: The average age was 65.9 ± 13.2 years. Most cases were male (52.2%), White (53.7%), and had primary open-angle glaucoma (62.7%). Forty-four eyes had prior glaucoma surgery (68.6%) and 46 (68.6%) had severe glaucoma. Though postoperative (postop) IOP changes were insignificant, the average postop number of medications dropped from 2.4 ± 1.4 to 1.9 ± 1.2 medications two years after surgery (p = 0.0451). Postop complications (23.9%) included GDI exposure (7.5%), inflammation (4.5%), shallow anterior chamber (4.5%), and strabismus (1.5%). Hypotony was observed in 4 eyes (5.9%), none of which developed hypotony maculopathy. The cumulative one-year failure rate was 56.7%, most of which were due to failure to lower IOP. Conclusion: In patients with baseline IOP ≤18 mmHg who had GDI surgery, though the change in IOP was not statistically significant, the number of medications dropped and visual field progression slowed in a subset of patients with adequate perimetric data. Due to a relatively high rate of complications and limited effectiveness in lowering IOP, GDI should be cautiously used in these eyes.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA