1.
Innovations (Phila) ; 19(2): 143-149, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38504149

RESUMEN

OBJECTIVE: This study evaluated the efficacy of the Minimally Invasive Targeted Resection (MiTR) device, a novel electrosurgical instrument that allows for targeted excision of a lung abnormality while using bipolar radiofrequency (RF) energy to seal blood vessels and airways. METHODS: The MiTR system was evaluated in 7 acute and 2 chronic porcine (7-day) models to evaluate the efficacy of tissue excision with bipolar RF sealing of blood vessels and airways and application of an autologous blood patch into the excised tissue cavity. Air leak was recorded for all evaluations. The study was approved by the institutional ethical board. RESULTS: Nineteen lung tissue samples, measuring 2.5 cm long × 1.2 cm diameter, were excised. In 8 of 9 animals (89%), hemostasis and pneumostasis were observed visually at the completion of the procedure. In 2 of 2 chronic animals (100%), hemostasis and pneumostasis persisted for the 7-day observation period. Histologic examination of the excised samples showed preservation of the core parenchymal architecture without evident tissue damage of the samples that would impair pathologic analysis. CONCLUSIONS: Percutaneous resection of targeted lung tissue with the MiTR system demonstrated hemostasis and pneumostasis while obtaining a histologically intact sample. After regulatory approval, the use of this device could offer more tissue for analysis than a transthoracic needle biopsy or bronchoscopy and a far less invasive alternative to video-assisted thoracic surgery or thoracotomy. This may also expand patient and physician options for the early diagnosis and treatment of lung cancer.


Asunto(s)
Pulmón , Animales , Porcinos , Pulmón/cirugía , Pulmón/patología , Neumonectomía/instrumentación , Neumonectomía/métodos , Electrocirugia/instrumentación , Electrocirugia/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos/instrumentación , Hemostasis Quirúrgica/instrumentación , Hemostasis Quirúrgica/métodos , Cirugía Asistida por Computador/métodos , Cirugía Asistida por Computador/instrumentación
2.
Tex Heart Inst J ; 41(4): 368-72, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25120388

RESUMEN

Obese patients undergoing conscious-sedation surgery have increased perioperative morbidity because their excess abdominal tissue limits diaphragmatic excursion. We describe a simple device that might help attenuate this risk. We created a noninvasive suction device for abdominal suspension. By lifting the burden of excess weight, this device should decrease respiratory effort. To test the feasibility of excess weight removal in relieving cardiac stress, we tested 22 supine, healthy, normal-weight subjects by measuring their heart rates with and without a 13-kg tissue model on their abdomen to simulate excess weight. There was no significant difference in blood oxygen saturation before and after weight removal (P=0.318). However, the decrease in heart rate was significant (P <0.0001; paired 2-sample, one-tailed t test), which implies decreased respiratory effort. This result suggests the possibility that abdominal mass suspension in obese patients is associated with decreased respiratory effort.


Asunto(s)
Grasa Abdominal/patología , Sedación Consciente/instrumentación , Corazón/fisiología , Pulmón/fisiología , Obesidad/patología , Procedimientos Quirúrgicos Operativos , Adolescente , Biomarcadores/sangre , Diseño de Equipo , Estudios de Factibilidad , Voluntarios Sanos , Frecuencia Cardíaca , Humanos , Ensayo de Materiales , Obesidad/complicaciones , Obesidad/fisiopatología , Oxígeno/sangre , Posicionamiento del Paciente , Respiración , Succión , Posición Supina , Factores de Tiempo , Soporte de Peso , Adulto Joven