Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J Prosthet Dent ; 2024 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-38616155

RESUMEN

STATEMENT OF PROBLEM: Manually sculpting a wax pattern of a facial prosthesis is a time-, skill-, and resource-intensive process. Computer-aided design (CAD) methods have been proposed as a substitute for manual sculpting, but these techniques can still require high technical or artistic abilities. Three-dimensional morphable models (3DMMs) could semi-automate facial prosthesis CAD. Systematic comparisons of different design approaches are needed. PURPOSE: The purpose of this study was to compare the trueness and repeatability of replacing facial features with 3 methods of facial prosthesis design involving 3DMM, traditional CAD, and conventional manual sculpting techniques. MATERIAL AND METHODS: Fifteen participants without facial defects were scanned with a structured light scanner. The facial meshes were manipulated to generate artificial orbital, nasal, or combined defects. Three methods of facial prosthesis design were compared for the 15 participants and repeated to produce 5 of each design for 2 participants. For the 3DMM approach, the Leeds face model informed the designs in a statistically meaningful way. For the traditional CAD methods, designs were created by using mirroring techniques or from a nose model database. For the conventional manual sculpting techniques, wax patterns were manually created on 3D printed full face baseplates. For analysis, the unedited facial feature was the standard. The unsigned distance was calculated from each of the several thousand vertices on the unedited facial feature to the closest point on the external surface of the prosthesis prototype. The mean absolute error was calculated, and a Friedman test was performed (α=.05). RESULTS: The median mean absolute error was 1.13 mm for the 3DMM group, 1.54 mm for the traditional CAD group, and 1.49 mm for the manual sculpting group, with no statistically significant differences among groups (P=.549). Boxplots showed substantial differences in the distribution of mean absolute error among groups, with the 3DMM group showing the greatest consistency. The 3DMM approach produced repeat designs with the lowest coefficient of variation. CONCLUSIONS: The 3DMM approach shows potential as a semi-automated method of CAD. Further clinical research is planned to explore the 3DMM approach in a feasibility trial.

2.
Pilot Feasibility Stud ; 9(1): 110, 2023 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-37400919

RESUMEN

BACKGROUND: Facial prostheses can have a profound impact on patients' appearance, function and quality of life. There has been increasing interest in the digital manufacturing of facial prostheses which may offer many benefits to patients and healthcare services compared with conventional manufacturing processes. Most facial prosthesis research has adopted observational study designs with very few randomised controlled trials (RCTs) documented. There is a clear need for a well-designed RCT to compare the clinical and cost-effectiveness of digitally manufactured facial prostheses versus conventionally manufactured facial prostheses. This study protocol describes the planned conduct of a feasibility RCT which aims to address this knowledge gap and determine whether it is feasible to conduct a future definitive RCT. METHODS: The IMPRESSeD study is a multi-centre, 2-arm, crossover, feasibility RCT with early health technology assessment and qualitative research. Up to 30 participants with acquired orbital or nasal defects will be recruited from the Maxillofacial Prosthetic Departments of participating NHS hospitals. All trial participants will receive 2 new facial prostheses manufactured using digital and conventional manufacturing methods. The order of receiving the facial prostheses will be allocated centrally using minimisation. The 2 prostheses will be made in tandem and marked with a colour label to mask the manufacturing method to the participants. Participants will be reviewed 4 weeks following the delivery of the first prosthesis and 4 weeks following the delivery of the second prosthesis. Primary feasibility outcomes include eligibility, recruitment, conversion, and attrition rates. Data will also be collected on patient preference, quality of life and resource use from the healthcare perspective. A qualitative sub-study will evaluate patients' perception, lived experience and preference of the different manufacturing methods. DISCUSSION: There is uncertainty regarding the best method of manufacturing facial prostheses in terms of clinical effectiveness, cost-effectiveness and patient acceptability. There is a need for a well-designed RCT to compare digital and conventional manufacturing of facial prostheses to better inform clinical practice. The feasibility study will evaluate key parameters needed to design a definitive trial and will incorporate early health technology assessment and a qualitative sub-study to identify the potential benefits of further research. TRIAL REGISTRATION: ISRCTN ISRCTN10516986). Prospectively registered on 08 June 2021,  https://www.isrctn.com/ISRCTN10516986 .

3.
J Prosthet Dent ; 2023 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-37019749

RESUMEN

Designing nasal prostheses can be challenging because of the unpaired nature of the facial feature, especially in patients lacking preoperative information. Various nose model databases have been developed as a helpful starting point for the computer-aided design of nasal prostheses, but these do not appear to be readily accessible. Therefore, an open-access digital database of nose models has been generated based on a 3-dimensional (3D) morphable face model approach. This article describes the generation of the database, highlights steps for designing a nasal prosthesis, and points readers to the database for future clinical application and research.

4.
J Prosthet Dent ; 126(6): 805-815, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33581868

RESUMEN

STATEMENT OF PROBLEM: Facial prosthesis research uses a wide variety of outcome measures, which results in challenges when comparing the effectiveness of interventions among studies. Consensus is lacking regarding the most appropriate and meaningful outcome measures to use in facial prosthesis research to capture important perspectives. PURPOSE: The purpose of the systematic review was to identify and synthesize outcome measures used in facial prosthesis research. MATERIAL AND METHODS: Electronic searches were performed in 11 databases (including nonpeer-reviewed literature). The citations were searched, and expert societies were contacted to identify additional studies. Inclusion criteria comprised studies of participants with facial defects who required or had received prosthetic rehabilitation with an external facial prosthesis. Exclusion criteria comprised participants with ocular prostheses, case reports, case series with fewer than 5 participants, laboratory-based studies, and studies published before 1980. Study selection was performed independently by 2 reviewers. Discrepancies were resolved through discussion or by a third reviewer. Outcome measures were synthesized with a categorization approach based on the perspective, theme, and subtheme of the outcome measures. Quality assessment was performed with an appraisal tool that enabled evaluation of studies with diverse designs. RESULTS: Database searching identified 13 058 records, and 7406 remained after duplications were removed. After initial screening, 189 potentially relevant records remained, and 186 full texts were located (98% retrieval rate). After full-text screening, 124 records were excluded. Citation searches and contact with expert societies identified 4 further records. In total, 69 articles (grouped into 65 studies) were included. Studies were categorized as per the perspective of their outcome measures, with the following findings: patient-reported (74% of studies), clinical indicators (34%), clinician-reported (8%), multiple viewpoints (6%), and independent observer-reported (3%). Patient-reported outcome measures included tools to assess satisfaction, quality of life, and psychologic health. Variability in the choice of outcome measures was evident among the studies, with many self-designed, unvalidated, condition-specific questionnaires reported. A greater number of outcome measure themes emerged over time; themes such as service delivery and health state utility have recently been evaluated. CONCLUSIONS: Over the past 40 years, facial prosthesis research has focused on patient-reported outcome measures. Outcome measures relating to other perspectives have been used less frequently, although new themes appear to be emerging in the literature. Future research should use outcome measures with appropriate measurement properties for use with facial prosthetics.


Asunto(s)
Implantes Dentales , Calidad de Vida , Humanos , Evaluación de Resultado en la Atención de Salud
5.
J Prosthet Dent ; 122(3): 333-338, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30955940

RESUMEN

STATEMENT OF PROBLEM: Fabrication of conventional facial prostheses is a labor-intensive process which traditionally requires an impression of the facial defect and surrounding tissues. Inaccuracies occur during the facial moulage because of soft-tissue compression, the patient's reflex movements, or the lack of support for the impression material. A variety of 3D imaging techniques have been introduced during the production of facial prostheses. However, the accuracy of the different imaging techniques has not been evaluated sufficiently in this clinical context. PURPOSE: The purpose of this in vitro study was to compare the difference in accuracy of capturing oncology facial defects with multimodal image fusion and laser scanning against a cone beam computed tomography (CBCT) reference scan. MATERIAL AND METHODS: Ten gypsum casts of oncology facial defects were acquired. To produce reference models, a 3D volumetric scan was obtained using a CBCT scanner and converted into surface data using open-source medical segmentation software. This model was cropped to produce a CBCT mask using an open-source system for editing meshes. The multimodal image fusion model was created using stereophotogrammetry to capture the external facial features and a custom optical structured light scanner to record the defect. The gypsum casts were also scanned using a commercial 3D laser scanner to create the laser-scanned model. Analysis of the best fit of each experimental model to the CBCT mask was performed in MeshLab. The unsigned mean distance was used to measure the absolute deviation of each model from the CBCT mask. A paired-samples t test was conducted to compare the mean global deviation of the 2 imaging modalities from the CBCT masks (α=.05). RESULTS: A statistically significant difference was found in the mean global deviation between the multimodal imaging model (220 ±50 µm) and the laser-scanned model (170 ±70 µm); (t(9)=2.56, P=.031). The color error maps illustrated that the greatest error was located at sites distant to the prosthesis margins. CONCLUSIONS: The laser-scanned models were more accurate; however, the mean difference of 50 µm is unlikely to be clinically significant. The laser scanner had limited viewing angles and a longer scan time which may limit its transferability to maxillofacial practice.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Cara , Humanos , Imagenología Tridimensional , Rayos Láser , Fotogrametría
6.
Dent Mater ; 35(6): e113-e121, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30948229

RESUMEN

OBJECTIVE: To compare the retention force of individual clasps made from cobalt chromium (CoCr) or new aryl ketone polymer (AKP) material, Ultaire™ AKP, following prolonged fatigue testing along ideal and non-ideal paths of removal and to assess 3D deformation of the active and passive clasp tips. METHODS: CoCr and AKP clasps were manufactured in their standard, respective processes, digitally scanned prior to testing, then cycled 15,000 times over an e.max analogue crown in artificial saliva. Retentive load was measured in situ, as a function of cycles. Clasps were rescanned to assess deformation and along with their antagonists subjected to SEM to assess localised wear. RESULTS: Distortion of the CoCr clasps was consistently larger than Ultaire™ AKP clasps, irrespective of removal path. CoCr clasps had significantly higher retentive forces than AKP clasps, for both removal paths. Ultaire™ AKP clasps showed a lower but relatively constant retentive force. The non-ideal path of removal affected retentive forces for both clasp materials. SEM showed localised removal of glaze for e.max crowns used with CoCr clasps. SIGNIFICANCE: Ultaire™ AKP clasps showed significantly less permanent deformation and lower retentive force than CoCr clasps. Unlike CoCr, the Ultaire™ AKP clasps did not work harden, nor had as large a reduction in retentive force and accompanying permanent deformation; the retentive force for the Ultaire™ AKP clasps was consistent over 15,000 cycles of fatigue mimicking prolonged clinical use. The AKP material was more robust; showing minimal deformation even in non-ideal paths of removal, as many patients would routinely use.


Asunto(s)
Abrazadera Dental , Polímeros , Aleaciones de Cromo , Cobalto , Análisis del Estrés Dental , Retención de Dentadura , Humanos , Cetonas
7.
Surgeon ; 16(5): 265-270, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29275932

RESUMEN

AIM: Assess the feasibility, validity and precision of multimodal image fusion to capture oncology facial defects based on plaster casts. METHODS: Ten casts of oncology facial defects were acquired. To create gold standard models, a 3D volumetric scan of each cast was obtained with a cone beam computed tomography (CBCT) scanner (NewTomVG). This was converted into surface data using open-source medical segmentation software and cropped to produce a CBCT mask using an open-source system for editing meshes. For the experimental model, the external facial features were captured using stereophotogrammetry (DI4D) and the defect was recorded with a custom optical structured light scanner. The two meshes were aligned, merged and resurfaced using MeshLab to produce a fused model. Analysis was performed in MeshLab on the best fit of the fused model to the CBCT mask. The unsigned mean distance was used to measure the absolute deviation of each model from the CBCT mask. To assess the precision of the technique, the process of producing the fused model was repeated to create five models each for the casts representing the best, middle and worst results. RESULTS: Global mean deviation was 0.22 mm (standard deviation 0.05 mm). The precision of the method appeared to be acceptable although there was variability in the location of the error for the worst cast. CONCLUSION: This method for merging two independent scans to produce a fused model shows strong potential as an accurate and repeatable method of capturing facial defects. Further research is required to explore its clinical use.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Cara/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/cirugía , Procedimientos de Cirugía Plástica , Heridas y Lesiones/diagnóstico por imagen , Moldes Quirúrgicos , Simulación por Computador , Estudios de Factibilidad , Humanos , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Imagen Multimodal , Nariz/diagnóstico por imagen , Imagen Óptica , Órbita/diagnóstico por imagen , Fotogrametría , Prótesis e Implantes , Procedimientos de Cirugía Plástica/efectos adversos , Reproducibilidad de los Resultados , Heridas y Lesiones/etiología , Heridas y Lesiones/cirugía
8.
Dent Update ; 41(5): 386-8, 390-2, 394, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25073219

RESUMEN

Failure of a post-retained restoration can provide a challenge to the general dental practitioner (GDP) in terms of diagnosis, treatment planning and communication with the patient. The cause of failure must be identified, and a thorough assessment of the restoration, remaining tooth and its functional and aesthetic demands carried out in order to plan treatment to provide the most reliable result. Clinical Relevance: This article discusses the assessment of failing post-retained crowns, with discussion of reasons for failure, thereby assisting the GDP in decision-making and treatment planning for such teeth.


Asunto(s)
Fracaso de la Restauración Dental , Planificación de Atención al Paciente , Técnica de Perno Muñón , Coronas , Caries Dental/diagnóstico , Cementos Dentales/química , Diseño de Prótesis Dental , Fracaso de la Restauración Dental/clasificación , Humanos , Enfermedad Iatrogénica , Enfermedades Periapicales/diagnóstico , Retratamiento , Tratamiento del Conducto Radicular , Fracturas de los Dientes/diagnóstico , Preparación Protodóncica del Diente , Raíz del Diente/lesiones
9.
Eur J Prosthodont Restor Dent ; 13(3): 135-8, 2005 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-16180640

RESUMEN

UNLABELLED: The treatment of burning mouth Syndrome, in all its forms, is a challenge to the management of some older patients. The multi-factorial aetiology of this problem requires careful diagnosis and treatment planning to address the major aetiological factors for a given individual. This case report describes the treatment given to an elderly dentate female patient, whose main symptom was intense burning of her lower lip. The patient was aware of tooth clenching and various splints had been provided in the past, with limited improvement in symptoms. A simple removable appliance to prevent trapping of the soft tissues of the lower lip was provided, which produced a rapid and sustained reduction in symptoms. CLINICAL RELEVANCE: Solutions to some common, yet distressing, problems may well be appropriate for use in the Primary Dental Care setting. This solution to the problem of burning lower lip, may be useful for other patients with similar symptoms. It may be adapted for different clinical situations and is relatively non-invasive and reversible.


Asunto(s)
Síndrome de Boca Ardiente/terapia , Labio , Ferulas Oclusales , Anciano , Bruxismo/terapia , Femenino , Humanos
10.
Eur J Prosthodont Restor Dent ; 12(1): 29-32, 2004 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15058179

RESUMEN

Challenges in the treatment of our older dentate patients are arising more frequently, and novel solutions may be required to overcome them. This case report describes the treatment given to an elderly dentate female patient, whose lax peri-oral musculature was preventing a satisfactory oral seal from being achieved. This resulted in constant "drooling" and much social disability in an otherwise fit and gregarious lady. A simple removable appliance was provided to increase support to the tissues at the angles of the mouth. An immediate relief of the salivary leakage was achieved and maintained. Simple solutions may be available to problems which may cause great distress to our patients reducing the quality of their lives. This solution to the problem of peri-oral leakage, of a normal volume of saliva, may be useful for many other patients with similar problems, following loss of peri-oral muscle tone with age.


Asunto(s)
Ferulas Oclusales , Sialorrea/prevención & control , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Prótesis e Implantes
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA