Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 519
Filtrar
1.
J Arthroplasty ; 2024 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-38871065

RESUMEN

BACKGROUND: Although the direct anterior (DA) approach has increased in popularity for primary total hip arthroplasty (THA), there is limited evidence regarding its use for revision THA. It is unknown whether the dislocation benefit seen in the primary setting translates to revision cases. METHODS: This retrospective review compared the dislocation rates of revision THA performed through DA versus postero-lateral (PL) approaches at a single institution (2011 to 2021). Exclusion criteria included revision for instability, ≥ 2 prior revisions, approaches other than DA or PL, and placement of dual-mobility or constrained liners. There were 182 hips in 173 patients that met inclusion criteria. The average follow-up was 6.5 years (range, 2 to 8 years). RESULTS: There was a trend towards more both-component revisions being performed through the PL approach. There were no differences in dislocation rates between the DA revision and PL revision cohorts, which were 8.1% (5 of 72) and 7.5% (9 of 120), respectively (P = 0.999). Dislocation trended lower when the revision approach was discordant from the primary approach compared to cases where primary and revision had a concordant approach (4.9 versus 8.5%), but this was not statistically significant (P = 0.740). No significant differences were found in return to operating room (OR), 90-day emergency department (ED) visits, or 90-day readmissions. However, the length of stay was significantly shorter in patients who had DA revisions after a primary PL procedure (P = 0.021). CONCLUSION: Dislocation rates following revision THA did not differ between the DA and PL approaches irrespective of the primary approach. Surgeons should choose their revision approach based on their experience and the specific needs of the patient.

2.
BMC Med Inform Decis Mak ; 24(1): 154, 2024 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-38835009

RESUMEN

BACKGROUND: Extracting research of domain criteria (RDoC) from high-risk populations like those with post-traumatic stress disorder (PTSD) is crucial for positive mental health improvements and policy enhancements. The intricacies of collecting, integrating, and effectively leveraging clinical notes for this purpose introduce complexities. METHODS: In our study, we created a natural language processing (NLP) workflow to analyze electronic medical record (EMR) data and identify and extract research of domain criteria using a pre-trained transformer-based natural language model, all-mpnet-base-v2. We subsequently built dictionaries from 100,000 clinical notes and analyzed 5.67 million clinical notes from 38,807 PTSD patients from the University of Pittsburgh Medical Center. Subsequently, we showcased the significance of our approach by extracting and visualizing RDoC information in two use cases: (i) across multiple patient populations and (ii) throughout various disease trajectories. RESULTS: The sentence transformer model demonstrated high F1 macro scores across all RDoC domains, achieving the highest performance with a cosine similarity threshold value of 0.3. This ensured an F1 score of at least 80% across all RDoC domains. The study revealed consistent reductions in all six RDoC domains among PTSD patients after psychotherapy. We found that 60.6% of PTSD women have at least one abnormal instance of the six RDoC domains as compared to PTSD men (51.3%), with 45.1% of PTSD women with higher levels of sensorimotor disturbances compared to men (41.3%). We also found that 57.3% of PTSD patients have at least one abnormal instance of the six RDoC domains based on our records. Also, veterans had the higher abnormalities of negative and positive valence systems (60% and 51.9% of veterans respectively) compared to non-veterans (59.1% and 49.2% respectively). The domains following first diagnoses of PTSD were associated with heightened cue reactivity to trauma, suicide, alcohol, and substance consumption. CONCLUSIONS: The findings provide initial insights into RDoC functioning in different populations and disease trajectories. Natural language processing proves valuable for capturing real-time, context dependent RDoC instances from extensive clinical notes.


Asunto(s)
Registros Electrónicos de Salud , Procesamiento de Lenguaje Natural , Trastornos por Estrés Postraumático , Humanos , Trastornos por Estrés Postraumático/terapia , Masculino , Femenino , Adulto , Persona de Mediana Edad
3.
J Diabetes Sci Technol ; : 19322968241247568, 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38715259

RESUMEN

The older population is increasing worldwide and up to 30% of older adults have diabetes. Older adults with diabetes are at risk of glucose-related acute and chronic complications. Recently, mostly in type 1 diabetes (T1D), continuous glucose monitoring (CGM) devices have proven beneficial in improving time in range (TIR glucose, 70-180 mg/dL or glucose 3.9-10 mmol/L), glycated hemoglobin (HbA1c), and in lowering hypoglycemia (time below range [TBR] glucose <70 mg/dL or glucose <3.9 mmol/L). The international consensus group formulated CGM glycemic targets relating to older adults with diabetes based on very limited data. Their recommendations, based on expert opinion, were aimed at mitigating hypoglycemia in all older adults. However, older adults with diabetes are a heterogeneous group, ranging from healthy to very complex frail individuals based on chronological, biological, and functional aging. Recent clinical trial and real-world data, mostly from healthy older adults with T1D, demonstrated that older adults often achieve CGM targets, including TIR recommended for non-vulnerable groups, but less often meet the recommended TBR <1%. Existing data also support that hypoglycemia avoidance may be more strongly related to minimization of glucose variability (coefficient of variation [CV]) rather than lower TIR. Very limited data are available for glucose goals in older adults adjusted for the complexity of their health status. Herein, we review the bidirectional associations between glucose and health status in older adults with diabetes; use of diabetes technologies, and their impact on glucose control; discuss current guidelines; and propose a new set of CGM targets for older adults with insulin-treated diabetes that are individualized for health and living status.

4.
Aging Ment Health ; : 1-14, 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38708873

RESUMEN

OBJECTIVES: Despite growing interest, the cost-effectiveness of eHealth interventions for supporting quality of life of people with dementia and their caregivers remains unclear. This study evaluated the cost-effectiveness of the FindMyApps intervention, compared to digital care-as-usual. FindMyApps aims to help people with dementia and their caregivers find and learn to use tablet apps that may support social participation and self-management of people with dementia and sense of competence of caregivers. METHOD: A randomised controlled trial (Netherlands Trial Register NL8157) was conducted, including people with mild cognitive impairment (MCI) or mild dementia and their informal caregivers (FindMyApps n = 76, digital care-as-usual n = 74). Outcomes for people with MCI/dementia were Quality-Adjusted Life-Years (QALYs), calculated from EQ-5D-5L data and the Dutch tariff for utility scores, social participation (Maastricht Social Participation Profile) and quality of life (Adult Social Care Outcomes Toolkit), and for caregivers, QALYs and sense of competence (Short Sense of Competence Questionnaire). Societal costs were calculated using data collected with the RUD-lite instrument and the Dutch costing guideline. Multiple imputation was employed to fill in missing cost and effect data. Bootstrapped multilevel models were used to estimate incremental total societal costs and incremental effects between groups which were then used to calculate Incremental Cost-Effectiveness Ratios (ICERs). Cost-effectiveness acceptability curves were estimated. RESULTS: In the FindMyApps group, caregiver SSCQ scores were significantly higher compared to care-as-usual, n = 150, mean difference = 0.75, 95% CI [0.14, 1.38]. Other outcomes did not significantly differ between groups. Total societal costs for people with dementia were not significantly different, n = 150, mean difference = €-774, 95%CI [-2.643, .,079]. Total societal costs for caregivers were significantly lower in the FindMyApps group compared to care-as-usual, n = 150, mean difference = € -392, 95% CI [-1.254, -26], largely due to lower supportive care costs, mean difference = €-252, 95% CI [-1.009, 42]. For all outcomes, the probability that FindMyApps was cost-effective at a willingness-to-pay threshold of €0 per point of improvement was 0.72 for people with dementia and 0.93 for caregivers. CONCLUSION: FindMyApps is a cost-effective intervention for supporting caregivers' sense of competence. Further implementation of FindMyApps is warranted.

5.
J Diabetes Sci Technol ; : 19322968241245627, 2024 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-38613225

RESUMEN

BACKGROUND: Benefits of hybrid closed-loop (HCL) systems in a high-risk group with type 1 diabetes and impaired awareness of hypoglycemia (IAH) have not been well-explored. METHODS: Adults with Edmonton HYPO scores ≥1047 were randomized to 26-weeks HCL (MiniMed™ 670G) vs standard therapy (multiple daily injections or insulin pump) without continuous glucose monitoring (CGM) (control). Primary outcome was percentage CGM time-in-range (TIR; 70-180 mg/dL) at 23 to 26 weeks post-randomization. Major secondary endpoints included magnitude of change in counter-regulatory hormones and autonomic symptom responses to hypoglycemia at 26-weeks post-randomization. A post hoc analysis evaluated glycemia risk index (GRI) comparing HCL with control groups at 26 weeks post-randomization. RESULTS: Nine participants (median [interquartile range (IQR)] age 51 [41, 59] years; 44% male; enrolment HYPO score 1183 [1058, 1308]; Clarke score 6 [6, 6]; n = 5 [HCL]; n = 4 [control]) completed the study. Time-in-range was higher using HCL vs control (70% [68, 74%] vs 48% [44, 50%], P = .014). Time <70 mg/dL did not differ (HCL 3.8% [2.7, 3.9] vs control 6.5% [4.3, 8.6], P = .14) although hypoglycemia episode duration was shorter (30 vs 50 minutes, P < .001) with HCL. Glycemia risk index was lower with HCL vs control (38.1 [30.0, 39.2] vs 70.8 [58.5, 72.4], P = .014). Following 6 months of HCL use, greater dopamine (24.0 [12.3, 27.6] vs -18.5 [-36.5, -4.8], P = .014), and growth hormone (6.3 [4.6, 16.8] vs 0.5 [-0.8, 3.0], P = .050) responses to hypoglycemia were observed. CONCLUSIONS: Six months of HCL use in high-risk adults with severe IAH increased glucose TIR and improved GRI without increased hypoglycemia, and partially restored counter-regulatory responses. CLINICAL TRIAL REGISTRATION: ACTRN12617000520336.

6.
JAMA ; 331(17): 1460-1470, 2024 05 07.
Artículo en Inglés | MEDLINE | ID: mdl-38581198

RESUMEN

Importance: The Cluster Randomized Trial of PSA Testing for Prostate Cancer (CAP) reported no effect of prostate-specific antigen (PSA) screening on prostate cancer mortality at a median 10-year follow-up (primary outcome), but the long-term effects of PSA screening on prostate cancer mortality remain unclear. Objective: To evaluate the effect of a single invitation for PSA screening on prostate cancer-specific mortality at a median 15-year follow-up compared with no invitation for screening. Design, Setting, and Participants: This secondary analysis of the CAP randomized clinical trial included men aged 50 to 69 years identified at 573 primary care practices in England and Wales. Primary care practices were randomized between September 25, 2001, and August 24, 2007, and men were enrolled between January 8, 2002, and January 20, 2009. Follow-up was completed on March 31, 2021. Intervention: Men received a single invitation for a PSA screening test with subsequent diagnostic tests if the PSA level was 3.0 ng/mL or higher. The control group received standard practice (no invitation). Main Outcomes and Measures: The primary outcome was reported previously. Of 8 prespecified secondary outcomes, results of 4 were reported previously. The 4 remaining prespecified secondary outcomes at 15-year follow-up were prostate cancer-specific mortality, all-cause mortality, and prostate cancer stage and Gleason grade at diagnosis. Results: Of 415 357 eligible men (mean [SD] age, 59.0 [5.6] years), 98% were included in these analyses. Overall, 12 013 and 12 958 men with a prostate cancer diagnosis were in the intervention and control groups, respectively (15-year cumulative risk, 7.08% [95% CI, 6.95%-7.21%] and 6.94% [95% CI, 6.82%-7.06%], respectively). At a median 15-year follow-up, 1199 men in the intervention group (0.69% [95% CI, 0.65%-0.73%]) and 1451 men in the control group (0.78% [95% CI, 0.73%-0.82%]) died of prostate cancer (rate ratio [RR], 0.92 [95% CI, 0.85-0.99]; P = .03). Compared with the control, the PSA screening intervention increased detection of low-grade (Gleason score [GS] ≤6: 2.2% vs 1.6%; P < .001) and localized (T1/T2: 3.6% vs 3.1%; P < .001) disease but not intermediate (GS of 7), high-grade (GS ≥8), locally advanced (T3), or distally advanced (T4/N1/M1) tumors. There were 45 084 all-cause deaths in the intervention group (23.2% [95% CI, 23.0%-23.4%]) and 50 336 deaths in the control group (23.3% [95% CI, 23.1%-23.5%]) (RR, 0.97 [95% CI, 0.94-1.01]; P = .11). Eight of the prostate cancer deaths in the intervention group (0.7%) and 7 deaths in the control group (0.5%) were related to a diagnostic biopsy or prostate cancer treatment. Conclusions and Relevance: In this secondary analysis of a randomized clinical trial, a single invitation for PSA screening compared with standard practice without routine screening reduced prostate cancer deaths at a median follow-up of 15 years. However, the absolute reduction in deaths was small. Trial Registration: isrctn.org Identifier: ISRCTN92187251.


Asunto(s)
Detección Precoz del Cáncer , Antígeno Prostático Específico , Neoplasias de la Próstata , Anciano , Humanos , Masculino , Persona de Mediana Edad , Detección Precoz del Cáncer/métodos , Detección Precoz del Cáncer/estadística & datos numéricos , Inglaterra/epidemiología , Estudios de Seguimiento , Tamizaje Masivo/métodos , Tamizaje Masivo/estadística & datos numéricos , Clasificación del Tumor , Antígeno Prostático Específico/sangre , Neoplasias de la Próstata/diagnóstico , Neoplasias de la Próstata/epidemiología , Neoplasias de la Próstata/mortalidad , Neoplasias de la Próstata/terapia , Gales/epidemiología , Ultrasonografía , Biopsia Guiada por Imagen
7.
JCEM Case Rep ; 2(4): luae051, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38601064

RESUMEN

Primary aldosteronism (PA) is the most common form of secondary hypertension. Accurate subtyping of PA is essential to identify unilateral disease, as adrenalectomy improves outcomes. Subtyping PA requires adrenal vein sampling (AVS), which is technically challenging and results from AVS may not always be conclusive. We present a case of a 37-year-old man with PA whose AVS studies were inconclusive due to apparent bilateral aldosterone suppression (ABAS). As a result, our patient was misdiagnosed as having bilateral PA and medically managed until a repeat AVS showed lateralization to the right adrenal gland. ABAS is an underrecognized phenomenon that may confound the subtyping of PA. We recommend repeating AVS in such cases and discuss strategies to minimize ABAS.

8.
Res Sq ; 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38464073

RESUMEN

Background: Extracting research of domain criteria (RDoC) from high-risk populations like those with post-traumatic stress disorder (PTSD) is crucial for positive mental health improvements and policy enhancements. The intricacies of collecting, integrating, and effectively leveraging clinical notes for this purpose introduce complexities. Methods: In our study, we created an NLP workflow to analyze electronic medical record (EMR) data, and identify and extract research of domain criteria using a pre-trained transformer-based natural language model, allmpnet-base-v2. We subsequently built dictionaries from 100,000 clinical notes and analyzed 5.67 million clinical notes from 38,807 PTSD patients from the University of Pittsburgh Medical Center. Subsequently, we showcased the significance of our approach by extracting and visualizing RDoC information in two use cases: (i) across multiple patient populations and (ii) throughout various disease trajectories. Results: The sentence transformer model demonstrated superior F1 macro scores across all RDoC domains, achieving the highest performance with a cosine similarity threshold value of 0.3. This ensured an F1 score of at least 80% across all RDoC domains. The study revealed consistent reductions in all six RDoC domains among PTSD patients after psychotherapy. Women had the highest abnormalities of sensorimotor systems, while veterans had the highest abnormalities of negative and positive valence systems. The domains following first diagnoses of PTSD were associated with heightened cue reactivity to trauma, suicide, alcohol, and substance consumption. Conclusions: The findings provide initial insights into RDoC functioning in different populations and disease trajectories. Natural language processing proves valuable for capturing real-time, context dependent RDoC instances from extensive clinical notes.

9.
J Diabetes Sci Technol ; : 19322968241236771, 2024 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-38491800

RESUMEN

BACKGROUND: Combining a continuous glucose monitor with an insulin delivery cannula (CGM-IS) could benefit clinical outcomes. We evaluated the feasibility of a single-needle insertion electrochemical investigational CGM-IS (Pacific Diabetes Technologies, Portland, Oregon) in type 1 diabetes adults. METHODS: Following 48 hours run-in using a Medtronic 780G in manual mode with a commercial insulin set, 12 participants commenced insulin delivery using the CGM-IS. A standardized test meal was eaten on the mornings of days 1 and 4. Venous samples were collected every 10 minutes one hour prior to and 15 minutes post-meal for four hours. CGM-IS glucose measurements were post-processed with a single capillary blood calibration during warm-up and benchmarked against YSI. A Dexcom G6 sensor was worn post-consent to study end. RESULTS: Mean absolute relative difference (MARD) for the CGM-IS glucose measurements was 9.2% (484 paired data points). Consensus error grid revealed 88.6% within zone A and 100% in A + B. Mean (SD) % bias was -3.5 (11.7) %. There were 35 paired YSI readings <100 mg/dL cutoff and 449 ≥100 mg/dL with 81.4% within ±15 mg/dL or ±15%, and 89.9% within ±20 mg/dL or ±20%. Two cannula occlusions required discontinuation of insulin delivery: one at 70 hours post insertion and another during the day 4 meal test. Mean (SD) Dexcom glucose measurements during run-in and between meal tests was respectively 161.3 ± 27.3 mg/dL versus 158.0 ± 25.6 mg/dL; P = .39 and corresponding mean total daily insulin delivered by the pump was 58.0 ± 25.4 Units versus 57.1 ± 28.8 Units; P = .47. CONCLUSIONS: Insulin delivery and glucose sensing with the investigational CGM-IS was feasible. Longer duration studies are needed.

10.
Diabetes Technol Ther ; 26(3): 190-197, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38444313

RESUMEN

Aim: To assess the real-world performance of MiniMed™ 780G for Australians with type 1 diabetes (T1D) following advanced hybrid closed loop (AHCL) activation and to evaluate the effect of changing from MiniMed 670/770G to 780G. Methods: We analyzed deidentified Carelink™ continuous glucose monitoring (CGM) data from Australian users from January 2020 to December 2022, including the proportion attaining three major consensus targets: Glucose management indicator (GMI <7.0%), time in range (TIR 70-180 mg/dL >70%), and time below range (TBR 70 mg/dL <4%). Results: Comparing 670/770G users (n = 5676) for mean ± standard deviation 364 ± 244 days with 780G users (n = 3566) for 146 ± 145 days, the latter achieved a higher TIR (72.6% ± 10.6% vs. 67.3% ± 11.4%; P < 0.001), lower time above range (TAR) (25.5% ± 10.9% vs. 30.6% ± 11.7%; P < 0.001), and lower GMI (6.9% ± 0.4% vs. 7.2% ± 0.4%; P < 0.001) without compromising TBR (1.9% ± 1.8% vs. 2.0% ± 1.8%; P = 0.0015). Of 1051 670/770G users transitioning to 780G, TIR increased (70.0% ± 10.7% to 74.0% ± 10.2%; P < 0.001), TAR decreased (28.1% ± 10.9% to 24.0% ± 10.7%; P < 0.001), and TBR was unchanged. The percentage of users attaining all three CGM targets was higher in 780G users (50.1% vs. 29.5%; P < 0.001). CGM metrics were stable at 12 months post-transition. Conclusion: Real-world data from Australia shows that a higher proportion of MiniMed 780G users meet clinical targets for CGM consensus metrics compared to MiniMed 670/770G users and glucose control was sustained over 12 months.


Asunto(s)
Pueblos de Australasia , Automonitorización de la Glucosa Sanguínea , Insulina , Humanos , Australia , Glucemia , Insulina/uso terapéutico , Insulina Regular Humana
11.
Cell Genom ; 4(3): 100511, 2024 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-38428419

RESUMEN

The development of cancer is an evolutionary process involving the sequential acquisition of genetic alterations that disrupt normal biological processes, enabling tumor cells to rapidly proliferate and eventually invade and metastasize to other tissues. We investigated the genomic evolution of prostate cancer through the application of three separate classification methods, each designed to investigate a different aspect of tumor evolution. Integrating the results revealed the existence of two distinct types of prostate cancer that arise from divergent evolutionary trajectories, designated as the Canonical and Alternative evolutionary disease types. We therefore propose the evotype model for prostate cancer evolution wherein Alternative-evotype tumors diverge from those of the Canonical-evotype through the stochastic accumulation of genetic alterations associated with disruptions to androgen receptor DNA binding. Our model unifies many previous molecular observations, providing a powerful new framework to investigate prostate cancer disease progression.


Asunto(s)
Neoplasias de la Próstata , Masculino , Humanos , Neoplasias de la Próstata/genética , Próstata/metabolismo , Mutación , Genómica , Evolución Molecular
12.
Artículo en Inglés | MEDLINE | ID: mdl-38373265

RESUMEN

OBJECTIVE: We compared treatment satisfaction with a tubeless insulin pump (Omnipod DASH® Insulin Management System) to usual care (multiple daily injections [MDI] or tubed insulin pump therapy [IPT]) in adults with type 1 diabetes using self-monitoring blood glucose (SMBG). RESEARCH DESIGN AND METHODS: Adults with type 1 diabetes on MDI (n = 40) or IPT (n = 25) from four diabetes centers in Australia were randomized in a 1:1 non-blinded manner to Omnipod DASH System (Omnipod group) or continue usual care (Usual Care group) for 12 weeks, followed by a further 12-week extension where all participants used the device. The primary outcome was treatment satisfaction assessed by change in Diabetes Technology Questionnaire 'current' (ΔDTQ-current) score at 12-weeks (study-end). Secondary outcomes included ΔDTQ-current following extension and other participant-reported outcomes (PROs) measuring quality of life, burden of disease treatment, glycemic and device-related outcomes at 12-weeks (study-end) and 24-weeks (end-extension). RESULTS: Treatment satisfaction improved more in Omnipod group vs. Usual Care group (ΔDTQ-current score of 16.4 [21.2] vs. 0.0 [12.8]; p < 0.001) at study-end. Significantly greater improvements in other PROs and HbA1c were also observed. Improvements in DTQ-current and other PROs comparing study-end and end-extension were similar. While %TIR change from baseline did not differ at study-end (-2.0 [12.7] %), it was significantly greater at end-extension (5.6 [10.9] %; p = 0.016). CONCLUSIONS: Omnipod DASH System resulted in greater treatment satisfaction at 12 weeks in adults with type 1 diabetes using SMBG which was sustained after 24 weeks of device use without compromising sleep quality and fear of hypoglycemia. Improvements in glycemia were also observed.

13.
Diabetes Technol Ther ; 26(S3): 84-96, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38377316

RESUMEN

The physical and psychological benefits of exercise are particularly pertinent to people with type 1 diabetes (T1D). The variability in subcutaneous insulin absorption and the delay in offset and onset in glucose lowering action impose limitations, given the rapidly varying insulin requirements with exercise. Simultaneously, there are challenges to glucose monitoring. Consequently, those with T1D are less likely to exercise because of concerns regarding glucose instability. While glucose control with exercise can be enhanced using automated insulin delivery (AID), all commercially available AID systems remain limited by the pharmacokinetics of subcutaneous insulin delivery. Although glycemic responses may vary with exercises of differing intensities and durations, the principles providing the foundation for guidelines include minimization of insulin on board before exercise commencement, judicious and timely carbohydrate supplementation, and when possible, a reduction in insulin delivered in anticipation of planned exercise. There is an increasing body of evidence in support of superior glucose control with AID over manual insulin dosing in people in T1D who wish to exercise. The MiniMed™ 780G AID system varies basal insulin delivery with superimposed automated correction boluses. It incorporates a temporary (elevated glucose) target of 8.3 mmol/L (150 mg/dL) and when it is functioning, the autocorrection boluses are stopped. As the device has recently become commercially available, there are limited data assessing glucose control with the MiniMed™ 780G under exercise conditions. Importantly, when exercise was planned and implemented within consensus guidelines, %time in range and %time below range targets were met. A practical approach to exercising with the device is provided with illustrative case studies. While there are limitations to spontaneity imposed on any AID device due to the pharmacokinetics associated with the subcutaneous delivery of current insulin formulations, the MiniMed™ 780G system provides people with T1D an excellent option for exercising safely if the appropriate strategies are implemented.


Asunto(s)
Diabetes Mellitus Tipo 1 , Insulina , Humanos , Insulina/uso terapéutico , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/uso terapéutico , Glucemia , Automonitorización de la Glucosa Sanguínea , Sistemas de Infusión de Insulina , Insulina Regular Humana/uso terapéutico
14.
Diabetes Res Clin Pract ; 208: 111123, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38309532

RESUMEN

AIMS: Understanding the lived experience of using a tubeless insulin pump and how this differs compared to usual care (tubed insulin pump therapy (IPT) vs multiple daily injections (MDI)). METHODS: Interviews were conducted after 12-weeks of using the Omnipod DASH Insulin Management System (Insulet, Acton, MA) and analysed using thematic analysis. RESULTS: Fifty-eight adults (35 female; mean age 42;SD 13 years; 35 previous MDI) were interviewed. Most (84 %) wanted to continue using the device. Experiences fit two themes: 1. Taking back control of my diabetes: many previous MDI users perceived improved glycaemic control, explained by more "nuanced" control, with some reporting positive effects during exercise and sleep. Many previous MDI and IPT users endorsed positive experiences in concealing or disclosing their diabetes to others. However, some previous MDI users reported negative psychosocial experiences due to feeling continuously "attached" to their diabetes. 2. Barriers and facilitators of device acceptability: both MDI and IPT users cited wearability, alarms and the financial cost impacted their choice to continue device use. IPT users reported positive wearability experiences. CONCLUSIONS: The tubeless pump improved diabetes management perceptions for both MDI and tubed pump users. However, participants' prior glucose management affected perceptions of its advantages and disadvantages.


Asunto(s)
Diabetes Mellitus Tipo 1 , Adulto , Humanos , Femenino , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/psicología , Hipoglucemiantes/uso terapéutico , Australia , Insulina/uso terapéutico , Inyecciones , Sistemas de Infusión de Insulina , Glucemia
15.
J Diabetes Sci Technol ; : 19322968241231307, 2024 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-38372246

RESUMEN

BACKGROUND: Glycemia risk index (GRI) is a novel composite metric assessing overall glycemic risk, accounting for both hypoglycemia and hyperglycemia and weighted toward extremes. Data assessing GRI as an outcome measure in closed-loop studies and its relation with conventional key continuous glucose monitoring (CGM) metrics are limited. METHODS: A post hoc analysis was performed to evaluate the sensitivity of GRI in assessing glycemic quality in adults with type 1 diabetes randomized to 26 weeks hybrid closed-loop (HCL) or manual insulin delivery (control). The primary outcome was GRI comparing HCL with control. Comparisons were made with changes in other CGM metrics including time in range (TIR), time above range (TAR), time below range (TBR), and glycemic variability (standard deviation [SD] and coefficient of variation [CV]). RESULTS: GRI with HCL (N = 61) compared with control (N = 59) was significantly lower (mean [SD] 33.5 [11.7] vs 56.1 [14.4], respectively; mean difference -22.8 [-27.2, -18.3], P = .001). The mean increase in TIR was +14.8 (11.0, 18.5)%. GRI negatively correlated with TIR for combined arms (r = -.954; P = .001), and positively with TAR >250 mg/dL (r = .901; P = .001), TBR < 54 mg/dL (r = .416; P = .001), and glycemic variability (SD [r = .916] and CV [r = .732]; P = .001 for both). CONCLUSIONS: Twenty-six weeks of HCL improved GRI, in addition to other CGM metrics, compared with standard insulin therapy. The improvement in GRI was proportionally greater than the change in TIR, and GRI correlated with all CGM metrics. We suggest that GRI may be an appropriate primary outcome for closed-loop trials.

16.
Diabetes Care ; 47(4): 747-755, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38381515

RESUMEN

OBJECTIVE: To determine feasibility and compare acceptance of an investigational Medtronic enhanced advanced hybrid closed-loop (e-AHCL) system in adults with type 1 diabetes with earlier iterations. RESEARCH DESIGN AND METHODS: This nonrandomized three-stage (12 weeks each) exploratory study compared e-AHCL (Bluetooth-enabled MiniMed 780G insulin pump with automatic data upload [780G] incorporating an updated algorithm; calibration-free all-in-one disposable sensor; 7-day infusion set) preceded by a run-in (non-Bluetooth 780G [670G V4.0 insulin pump] requiring manual data upload; Guardian Sensor 3 [GS3] requiring calibration; 3-day infusion set), stage 1 (780G; GS3; 3-day infusion set), and stage 2 (780G; calibration-free Guardian Sensor 4; 3-day infusion set). Treatment satisfaction was assessed by Diabetes Technology Questionnaire (DTQ)-current (primary outcome) and other validated treatment satisfaction tools with glucose outcomes by continuous glucose monitoring metrics. RESULTS: Twenty-one of 22 (11 women) participants (baseline HbA1c 6.7%/50 mmol/mol) completed the study. DTQ-current scores favored e-AHCL (123.1 [17.8]) versus run-in (101.6 [24.2]) and versus stage 1 (110.6 [20.8]) (both P < 0.001) but did not differ from stage 2 (119.4 [16.0]; P = 0.271). Diabetes Medication System Rating Questionnaire short-form scores for "Convenience and Efficacy" favored e-AHCL over run-in and all stages. Percent time in range 70-180 mg/dL was greater with e-AHCL versus run-in and stage 2 (+2.9% and +3.6%, respectively; both P < 0.001). Percent times of <70 mg/dL for e-AHCL were significantly lower than run-in, stage 1, and stage 2 (-0.9%, -0.6%, and -0.5%, respectively; all P < 0.01). CONCLUSIONS: e-AHCL was feasible. User satisfaction increased compared with earlier Medtronic HCL iterations without compromising glucose control.


Asunto(s)
Diabetes Mellitus Tipo 1 , Insulinas , Adulto , Humanos , Femenino , Glucemia , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Algoritmos , Sistemas de Infusión de Insulina , Insulina/uso terapéutico , Hipoglucemiantes/uso terapéutico
17.
Diabetes Technol Ther ; 26(5): 335-340, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38315502

RESUMEN

Older adults with type 1 diabetes may face challenges driving safely. Glucose "above-5-to-drive" is often recommended for insulin-treated diabetes to minimize hypoglycemia while driving. However, the effectiveness of this recommendation among older adults has not been evaluated. Older drivers with type 1 diabetes were assessed while using sensor-augmented insulin pumps during a 2-week clinical trial run-in. Twenty-three drivers (median age 69 years [interquartile range; IQR 65-72]; diabetes duration 37 years [20-45]) undertook 618 trips (duration 10 min [5-21]). Most trips (n = 535; 87%) were <30 min duration; 9 trips (1.5%) exceeded 90 min and 3 trips (0.5%) exceeded 120 min. Pre-trip continuous glucose monitoring (CGM) was >5.0 mmol/L for 577 trips (93%) and none of these had CGM <3.9 mmol/L during driving (including 8 trips >90 min and 3 trips >120 min). During 41 trips with pre-trip CGM ≤5.0 mmol/L, 11 trips had CGM <3.9 mmol/L. Seventy-one CGM alerts occurred during 60 trips (10%), of which 54 of 71 alerts (76%) were unrelated to hypoglycemia. Our findings support a glucose "above-5-to-drive" recommendation to avoid CGM-detected hypoglycemia among older drivers, including for prolonged drives, and highlight the importance of active CGM low-glucose alerts to prevent hypoglycemia during driving. Driving-related CGM usability and alert functionality warrant investigation. Clinical trial ACTRN1261900515190.


Asunto(s)
Conducción de Automóvil , Automonitorización de la Glucosa Sanguínea , Glucemia , Diabetes Mellitus Tipo 1 , Hipoglucemia , Hipoglucemiantes , Sistemas de Infusión de Insulina , Insulina , Humanos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/sangre , Anciano , Masculino , Femenino , Glucemia/análisis , Hipoglucemia/prevención & control , Hipoglucemiantes/uso terapéutico , Hipoglucemiantes/administración & dosificación , Insulina/administración & dosificación , Insulina/uso terapéutico , Persona de Mediana Edad
18.
J Diabetes Investig ; 15(5): 594-597, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38366869

RESUMEN

The gold standard for measuring insulin sensitivity (IS) is the hyperinsulinemic-euglycemic clamp, a time, costly, and labor-intensive research tool. A low insulin sensitivity is associated with a complication-risk in type 1 diabetes. Various formulae using clinical data have been developed and correlated with measured IS in type 1 diabetes. We consolidated multiple formulae into an online calculator (bit.ly/estimated-GDR), enabling comparison of IS and its probability of IS <4.45 mg/kg/min (low) or >6.50 mg/kg/min (high), as measured in a validation set of clamps in 104 adults with type 1 diabetes. Insulin sensitivity calculations using different formulae varied significantly, with correlations (R2) ranging 0.005-0.87 with agreement in detecting low and high glucose disposal rates in the range 49-93% and 89-100%, respectively. We demonstrate that although the calculated IS varies between formulae, their interpretation remains consistent. Our free online calculator offers a user-friendly tool for individual IS calculations and also offers efficient batch processing of data for research.


Asunto(s)
Diabetes Mellitus Tipo 1 , Técnica de Clampeo de la Glucosa , Resistencia a la Insulina , Humanos , Diabetes Mellitus Tipo 1/sangre , Femenino , Adulto , Masculino , Glucemia/análisis , Persona de Mediana Edad , Insulina
19.
J Diabetes Complications ; 38(3): 108702, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38387103

RESUMEN

AIMS: To relate adverse events with glucose correction rates in diabetic ketoacidosis (DKA) using variable rate intravenous insulin-infusions (VRIII). METHODS: Retrospective, observational study in adults with DKA who received insulin infusions between 2012 and 2017 at St Vincent's Hospital, Melbourne. Early correction of hyperglycaemia (<10 mmol/L) was evaluated for association with hypoglycaemia (<4.0 mmol/L), hypokalaemia (potassium <3.3 mmol/L) and clinical outcomes via regression analysis. RESULTS: The study involved 97 patients, with 93 % having type 1 diabetes. The mean age was 38 years, 47 % were women and 35 % were admitted to intensive care. Hypoglycaemia rates during 12 and 24 h of treatment were 6.2 % and 8.2 %, respectively with 58 % of patients recording their first BGL <10 mmol/L within 12 h and 88 % within 24 h. Ketone clearance time averaged at 15.6 h. Hyperglycaemia correction rates to <10 mmol/L were not different in those with/without hypoglycaemia at 12/24 h, in multivariate analysis including admission BGL. Hypokalaemia occurred in 40.2 % of patients and was associated with lower pH but not BGL correction rates. CONCLUSION: The VRIII protocol achieved early hyperglycaemia correction and ketoacidosis reversal with low hypoglycaemia risk. However, high hypokalaemia rates suggest the need for aggressive potassium replacement, especially in markedly acidotic patients.


Asunto(s)
Diabetes Mellitus , Cetoacidosis Diabética , Hiperglucemia , Hipoglucemia , Hipopotasemia , Adulto , Femenino , Humanos , Masculino , Cetoacidosis Diabética/tratamiento farmacológico , Cetoacidosis Diabética/epidemiología , Hiperglucemia/prevención & control , Hipoglucemia/inducido químicamente , Hipoglucemia/prevención & control , Hipopotasemia/inducido químicamente , Hipopotasemia/epidemiología , Insulina/efectos adversos , Insulina Regular Humana , Potasio , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA