Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Paediatr Perinat Epidemiol ; 36(3): 390-398, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34431114

RESUMEN

BACKGROUND: For initial respiratory management, continuous positive airway pressure (CPAP) is increasingly used for preterm infants, especially for gestational age less than 32 weeks. However, neonatologists are concerned about the potential risks of CPAP support failure. OBJECTIVES: To examine the association between different initial respiratory support modalities and the outcomes of preterm infants at <32 weeks of gestation across multiple neonatal intensive care units (NICU) in China. METHODS: This study was carried out over a period of 12 months in 2018. Unadjusted relative risks (RR) for demographic and clinical characteristics were calculated for CPAP failure and CPAP success in the total cohort using log-linear model based on generalised estimating equations for clustered observations. RESULTS: Among 1560 preterm infants delivered at <32 weeks, the incidence of CPAP failure was 10.3%. After adjustment for demographic and clinical factors, the relative risk of mortality (RR 7.54, 95% CI 5.56, 10.44), pneumothorax (RR 9.85, 95% CI 2.89, 61.53), pulmonary haemorrhage (RR 7.78, 95% CI 4.51, 14.64) and BPD (RR 3.65, 95% CI 3.65, 4.51) were considerably higher for infants in the CPAP failure group than those in the CPAP-S group. However, the risk of poor outcomes in CPAP failure infants was similar to that of those in the initial mechanical ventilation (MV) group. CONCLUSIONS: Continuous positive airway pressure failure was associated with an increased risk of mortality and major morbidities, including BPD, pulmonary haemorrhage and pneumothorax, and was comparable to the risk associated with initial MV.


Asunto(s)
Neumotórax , Síndrome de Dificultad Respiratoria del Recién Nacido , Presión de las Vías Aéreas Positiva Contínua/efectos adversos , Femenino , Humanos , Lactante , Recién Nacido , Recien Nacido Prematuro , Neumotórax/etiología , Embarazo , Síndrome de Dificultad Respiratoria del Recién Nacido/complicaciones , Síndrome de Dificultad Respiratoria del Recién Nacido/epidemiología , Síndrome de Dificultad Respiratoria del Recién Nacido/terapia , Estudios Retrospectivos
2.
Zhongguo Dang Dai Er Ke Za Zhi ; 23(8): 809-813, 2021 Aug 15.
Artículo en Inglés, Chino | MEDLINE | ID: mdl-34511170

RESUMEN

OBJECTIVES: To evaluate the accuracy and safety of measurements of transcutaneous carbon dioxide partial pressure (TcPCO2) and transcutaneous oxygen partial pressure (TcPO2) at electrode temperatures lower than the value used in clinical practice in very low birth weight infants. METHODS: A total of 45 very low birth weight infants were enrolled. TcPCO2 and TcPO2 measurements were performed in these infants. Two transcutaneous monitors were placed simultaneously for each subject. One electrode was set and maintained at 42℃ used in clinical practice for neonates (control group), and the other was successively set at 38℃, 39℃, 40°C, and 41℃ (experimental group). The paired t-test was used to compare the measurement results between the groups. A Pearson correlation analysis was used to analyze the correlation between the measurement results of the experimental group and control group, and between the measurement results of experimental group and arterial blood gas parameters. RESULTS: There was no significant difference in TcPCO2 between each experimental subgroup (38-41℃) and the control group. TcPCO2 in each experimental subgroup (38-41℃) was strongly positively correlated with TcPCO2 in the control group (r>0.9, P<0.05) and arterial carbon dioxide partial pressure (r>0.8, P<0.05). There were significant differences in TcPO2 between each experimental subgroup (38-41℃) and the control group (P<0.05), but TcPO2 in each experimental subgroup (38-41℃) was positively correlated with TcPO2 in the control group (r=0.493-0.574, P<0.05) and arterial oxygen partial pressure (r=0.324-0.399, P<0.05). No skin injury occurred during transcutaneous measurements at all electrode temperatures. CONCLUSIONS: Lower electrode temperatures (38-41℃) can accurately measure blood carbon dioxide partial pressure in very low birth weight infants, and thus can be used to replace the electrode temperature of 42°C. Transcutaneous measurements at the lower electrode temperatures may be helpful for understanding the changing trend of blood oxygen partial pressure.


Asunto(s)
Monitoreo de Gas Sanguíneo Transcutáneo , Dióxido de Carbono , Electrodos , Humanos , Lactante , Recién Nacido , Recién Nacido de muy Bajo Peso , Oxígeno , Presión Parcial , Temperatura
3.
BMC Pediatr ; 20(1): 321, 2020 06 29.
Artículo en Inglés | MEDLINE | ID: mdl-32600275

RESUMEN

BACKGROUND: The objective of this prospective, multicentre, observational cohort study was to evaluate the association between admission hypothermia and neonatal outcomes in very low-birth weight (VLBW) infants in multiple neonatal intensive care units (NICUs) in China. METHODS: Since January 1, 2018, a neonatal homogeneous cooperative research platform-Shandong Neonatal Network (SNN) has been established. The platform collects clinical data in a prospective manner on preterm infants with birth weights (BWs) < 1500 g and gestational ages (GAs) < 34 weeks born in 28 NICUs in Shandong Province. These infants were divided into normothermia, mild or moderate/severe hypothermia groups according to the World Health Organization (WHO) classifications of hypothermia. Associations between outcomes and hypothermia were tested in a bivariate analysis, followed by a logistic regression analysis. RESULTS: A total of 1247 VLBW infants were included in this analysis, of which 1100 infants (88.2%) were included in the hypothermia group, 554 infants (44.4%) in the mild hypothermia group and 546 infants (43.8%) in the moderate/severe hypothermia group. Small for gestational age (SGA), caesarean section, a low Apgar score at 5 min and intubation in the delivery room (DR) were related to admission hypothermia (AH). Mortality was the lowest when their admission temperature was 36.5 ~ 37.5 °C, and after adjustment for maternal and infant characteristics, mortality was significantly associated with AH. Compared with infants with normothermia (36.5 ~ 37.5 °C), the adjusted ORs of all deaths increased to 4.148 (95% CI 1.505-11.437) and 1.806 (95% CI 0.651-5.009) for infants with moderate/severe hypothermia and mild hypothermia, respectively. AH was also associated with a high likelihood of respiratory distress syndrome (RDS), intraventricular haemorrhage (IVH), and late-onset neonatal sepsis (LOS). CONCLUSIONS: AH is still very high in VLBW infants in NICUs in China. SGA, caesarean section, a low Apgar score at 5 min and intubation in the DR were associated with increased odds of hypothermia. Moderate/severe hypothermia was associated with mortality and poor outcomes, such as RDS, IVH, LOS.


Asunto(s)
Hipotermia , Cesárea , China/epidemiología , Femenino , Humanos , Hipotermia/epidemiología , Hipotermia/etiología , Lactante , Recién Nacido , Recien Nacido Prematuro , Recién Nacido de muy Bajo Peso , Unidades de Cuidado Intensivo Neonatal , Embarazo , Estudios Prospectivos
4.
Indian J Pediatr ; 85(10): 855-860, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29368111

RESUMEN

OBJECTIVE: To summarize the available randomized controlled trials (RCTs) to evaluate the effect of taurine supplementation on growth in low birth weight infants (LBW). METHODS: PubMed, EmBase, and Cochrane Library electronic databases were searched for published articles through March 2017. Analysis was done to examine the effect of taurine supplementation on growth, and sensitivity analysis was performed by removing each individual study from meta-analysis. RESULTS: Results of 9 trials totaling 216 LBW infants in the present meta-analysis were collected and analyzed. The conclusion of included studies demonstrated that taurine supplementation significantly reduced length gain (WMD:-0.18; P < 0.001), plasma glycine (WMD:-106.71; P = 0.033), alanine (WMD:-229.30; P = 0.002), leucine (WMD:-64.76; P < 0.001), tyrosine (WMD:-118.11; P < 0.001), histidine (WMD:-52.16; P < 0.001), proline (WMD: -84.29; P = 0.033), and asparagine-glutamine (WMD:-356.30; P < 0.001). However, taurine supplementation was associated with higher levels of acidic sterols (WMD:0.61; P = 0.024), total fatty acids (WMD:7.94; P = 0.050), total saturated fatty acids (WMD:9.70; P < 0.001), and unsaturated fatty acids (WMD:6.63; P < 0.001). Finally, taurine supplementation had little or no significant effect on weight gain, head circumference gain, plasma taurine, threonine, serine, citrulline, valine, methionine, isoleucine, phenylalanine, ornithine, lysine, arginine, glutamate, hydroxyproline, aspartate, dietary cholesterol, endogenous neutral sterols, cholesterol synthesis, and medium-chain triglycerides. CONCLUSIONS: The findings suggest that although there are several significant differences in plasma indeces, no significant effect on growth in LBW infants was observed with taurine supplementation.


Asunto(s)
Alimentos Fortificados , Fórmulas Infantiles , Recién Nacido de Bajo Peso/crecimiento & desarrollo , Taurina/uso terapéutico , Estatura , Cefalometría , Humanos , Recién Nacido de Bajo Peso/sangre , Recién Nacido , Aumento de Peso
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA