Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Nat Mater ; 22(3): 369-379, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36443576

RESUMEN

Messenger RNA has now been used to vaccinate millions of people. However, the diversity of pulmonary pathologies, including infections, genetic disorders, asthma and others, reveals the lung as an important organ to directly target for future RNA therapeutics and preventatives. Here we report the screening of 166 polymeric nanoparticle formulations for functional delivery to the lungs, obtained from a combinatorial synthesis approach combined with a low-dead-volume nose-only inhalation system for mice. We identify P76, a poly-ß-amino-thio-ester polymer, that exhibits increased expression over formulations lacking the thiol component, delivery to different animal species with varying RNA cargos and low toxicity. P76 allows for dose sparing when delivering an mRNA-expressed Cas13a-mediated treatment in a SARS-CoV-2 challenge model, resulting in similar efficacy to a 20-fold higher dose of a neutralizing antibody. Overall, the combinatorial synthesis approach allowed for the discovery of promising polymeric formulations for future RNA pharmaceutical development for the lungs.


Asunto(s)
COVID-19 , Animales , Ratones , ARN Mensajero/genética , SARS-CoV-2/genética , Polímeros/metabolismo , Pulmón , ARN/metabolismo
2.
Neurotoxicology ; 86: 162-165, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34363843

RESUMEN

The persisting need for effective clinical treatment of chemotherapy-induced neurotoxicity (CIN) motivates critical evaluation of preclinical models of CIN for their translational relevance. The present study aimed to provide the first quantitative evaluation of neural tissue exposed in vivo to a platinum-based anticancer compound, oxaliplatin (OX) during and after two commonly used dosing regimens: slow IV infusion used clinically and bolus IP injection used preclinically. Inductively-coupled plasma mass spectrometry analysis of dorsal root ganglia indicated that while differences in the temporal dynamics of platinum distribution exist, key drivers of neurotoxicity, e.g. peak concentrations and exposure, were not different across the two routes of administration. We conclude that the IP route of OX administration achieves clinically relevant pharmacokinetic exposure of neural tissues in a rodent model of CIN.


Asunto(s)
Antineoplásicos/administración & dosificación , Antineoplásicos/farmacocinética , Ganglios Espinales/efectos de los fármacos , Ganglios Espinales/metabolismo , Oxaliplatino/administración & dosificación , Oxaliplatino/farmacocinética , Administración Intravenosa , Animales , Vías de Administración de Medicamentos , Infusiones Parenterales , Compuestos de Platino/administración & dosificación , Compuestos de Platino/farmacocinética , Ratas , Ratas Endogámicas F344
3.
Nat Med ; 26(3): 341-347, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32152581

RESUMEN

Drug delivery to the skin is highly constrained by the stratum corneum barrier layer1. Here, we developed star-shaped particles, termed STAR particles, to dramatically increase skin permeability. STAR particles are millimeter-scale particles made of aluminum oxide or stainless steel with micron-scale projections designed to create microscopic pores across the stratum corneum. After gentle topical application for 10 s to porcine skin ex vivo, delivery of dermatological drugs and macromolecules, including those that cannot be given topically, was increased by 1 to 2 orders of magnitude. In mice treated with topical 5-fluorouracil, use of STAR particles increased the efficacy of the drug in suppressing the growth of subcutaneous melanoma tumors and prolonging survival. Moreover, topical delivery of tetanus toxoid vaccine to mice using STAR particles generated immune responses that were at least as strong as delivery of the vaccine by intramuscular injection, albeit at a higher dose for topical than intramuscular vaccine administration. STAR particles were well tolerated and effective at creating micropores when applied to the skin of human participants. Use of STAR particles provides a simple, low-cost and well-tolerated method for increasing drug and vaccine delivery to the skin and could widen the range of compounds that can be topically administered.


Asunto(s)
Sistemas de Liberación de Medicamentos , Vacunas/administración & dosificación , Administración Tópica , Animales , Cerámica , Melanoma/tratamiento farmacológico , Melanoma/patología , Metales , Ratones , Permeabilidad , Ratas , Piel , Acero Inoxidable , Porcinos
4.
Sci Adv ; 5(11): eaaw8145, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31723599

RESUMEN

To increase access to long-acting contraception, we developed a reversible contraceptive microneedle patch that is simple-to-administer, slowly releases contraceptive hormone (levonorgestrel) for >1 month, and generates no biohazardous sharps waste. After manually pressing the patch to skin for 1 min, microneedles rapidly separate from the patch within the skin due to effervescence triggered by contact with skin's interstitial fluid, as demonstrated in rats and human participants. Long-acting contraception is achieved by formulating microneedles with a biodegradable polymer [poly(lactic-co-glycolic) acid] that slowly releases levonorgestrel for ~1 month in vitro. In rats, the patch maintained levonorgestrel concentration above the human contraceptive threshold level for >1 month, and a placebo microneedle patch was well-tolerated in human participants. Women of reproductive age in three continents demonstrated interest in and preference for long-acting contraception by microneedle patch. These studies indicate that an effervescent microneedle patch could facilitate greater access to long-acting contraception.


Asunto(s)
Sistemas de Liberación de Medicamentos/métodos , Levonorgestrel/administración & dosificación , Anticoncepción Reversible de Larga Duración/instrumentación , Anticoncepción Reversible de Larga Duración/métodos , Adulto , Animales , Anticonceptivos Femeninos/administración & dosificación , Femenino , Humanos , Ratas Sprague-Dawley , Reproducibilidad de los Resultados , Adulto Joven
5.
ACS Sens ; 4(6): 1569-1576, 2019 06 28.
Artículo en Inglés | MEDLINE | ID: mdl-31070358

RESUMEN

Minimally invasive devices to detect molecules in dermal interstitial fluid (ISF) are desirable for point-of-care diagnostic and monitoring applications. In this study, we developed a microneedle (MN) patch that collects ISF for on-patch biomarker analysis by surface-enhanced Raman scattering (SERS). The micrometer-scale MNs create micropores in the skin surface, through which microliter quantities of ISF are collected onto plasmonic paper on the patch backing. The plasmonic paper was prepared by immobilizing poly(styrenesulfonate) (PSS) coated gold nanorods (AuNRs) on a thin strip of filter paper using plasmonic calligraphy. Negatively charged PSS was used to bind positively charged rhodamine 6G (R6G), which served as a model compound, and thereby localize R6G on AuNR surface. R6G bound on the AuNR surface was detected and quantified by acquiring SERS spectra from the plasmonic paper MN patch. This approach was used to measure pharmacokinetic profiles of R6G in ISF and serum from rats in vivo. This proof-of-concept study indicates that a plasmonic paper MN patch has the potential to enable on-patch measurement of molecules in ISF for research and future medical applications.


Asunto(s)
Dermis/química , Líquido Extracelular/química , Agujas , Papel , Rodaminas/análisis , Animales , Femenino , Oro/química , Inyecciones Intradérmicas/instrumentación , Inyecciones Intradérmicas/métodos , Nanotubos/química , Pruebas en el Punto de Atención , Poliestirenos/química , Prueba de Estudio Conceptual , Ratas , Rodaminas/sangre , Rodaminas/farmacocinética , Espectrometría Raman/métodos
6.
Biomed Microdevices ; 21(1): 14, 2019 02 06.
Artículo en Inglés | MEDLINE | ID: mdl-30725230

RESUMEN

Minimally invasive point-of-care diagnostic devices are of great interest for rapid detection of biomarkers in diverse settings. Although blood is the most common source of biomarkers, interstitial fluid (ISF) is an alternate body fluid that does not clot or contain red blood cells that often complicate analysis. However, ISF is difficult to collect. In this study, we assessed the utility of a microneedle patch to sample microliter volumes of ISF in a simple and minimally invasive manner. We demonstrated the use of ISF collected in this way for therapeutic drug monitoring by showing similar vancomycin pharmacokinetic profiles in ISF and serum from rats. We also measured polio-specific neutralizing antibodies and anti-polio IgG in ISF similar to serum in rats immunized with polio vaccine. These studies demonstrate the potential utility of ISF collected by microneedle patch in therapeutic drug monitoring and immunodiagnostic applications.


Asunto(s)
Dermis/metabolismo , Monitoreo de Drogas , Líquido Extracelular/metabolismo , Agujas , Vancomicina , Animales , Anticuerpos Neutralizantes/metabolismo , Anticuerpos Antivirales/metabolismo , Biomarcadores/metabolismo , Monitoreo de Drogas/instrumentación , Monitoreo de Drogas/métodos , Femenino , Inmunoglobulina G/metabolismo , Inyecciones Intradérmicas/instrumentación , Inyecciones Intradérmicas/métodos , Poliovirus/metabolismo , Vacunas contra Poliovirus/farmacología , Ratas , Ratas Wistar , Vancomicina/farmacocinética , Vancomicina/farmacología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA