Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 247
Filtrar
2.
Respirol Case Rep ; 12(7): e01427, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39006515

RESUMEN

Acute exacerbation of idiopathic interstitial pneumonias (AE-IIPs) is a disease associated with a poor prognosis in patients with IIPs. However, the specific characteristics of fluorine-18 2-fluoro-2-deoxy-d-glucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) imaging for AE-IIPs remain unclear. Herein, we present the case of a patient with lung cancer combined with IIPs who underwent 18F-FDG PET/CT at the early onset of AE-IIPs. The scan, conducted 18 days post-bronchoscopy for lung cancer evaluation, revealed AE-IIPs before the onset of respiratory failure. New ground-glass opacities appeared, accompanied by significant 18F-FDG accumulation extending beyond these regions. To the best of our knowledge, this report represents the first assessment of 18F-FDG PET/CT images at the early onset of AE-IIPs before respiratory failure in humans. The observed features in this PET image could potentially contribute to our understanding of the pathophysiology of AE-IIPs.

3.
Eur Radiol ; 2024 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-38985184

RESUMEN

OBJECTIVES: To compare the diagnostic performance of conventional non-contrast CT, dual-energy spectral CT, and chemical-shift MRI (CS-MRI) in discriminating lipid-poor adenomas (> 10-HU on non-contrast CT) from non-adenomas. METHODS: A total of 110 patients (69 men; 41 women; mean age 66.5 ± 13.4 years) with 80 lipid-poor adenomas and 30 non-adenomas who underwent non-contrast dual-layer spectral CT and CS-MRI were retrospectively identified. For each lesion, non-contrast attenuation on conventional 120-kVp images, ΔHU-index ([attenuation difference between virtual monoenergetic 140-keV and 40-keV images]/conventional attenuation × 100), and signal intensity index (SI-index) were quantified. Each parameter was compared between adenomas and non-adenomas using the Mann-Whitney U-test. The area under the receiver operating characteristic curve (AUC) and sensitivity to achieve > 95% specificity for adenoma diagnosis were determined. RESULTS: Conventional non-contrast attenuation was lower in adenomas than in non-adenomas (22.4 ± 8.6 HU vs 32.8 ± 48.5 HU), whereas ΔHU-index (148.0 ± 103.2 vs 19.4 ± 25.8) and SI-index (41.6 ± 19.6 vs 4.2 ± 10.2) were higher in adenomas (all, p < 0.001). ΔHU-index showed superior performance to conventional non-contrast attenuation (AUC: 0.919 [95% CI: 0.852-0.963] vs 0.791 [95% CI: 0.703-0.863]; sensitivity: 75.0% [60/80] vs 27.5% [22/80], both p < 0.001), and near equivalent to SI-index (AUC: 0.952 [95% CI: 0.894-0.984], sensitivity 85.0% [68/80], both p > 0.05). Both the ΔHU-index and SI-index provided a sensitivity of 96.0% (48/50) for hypoattenuating adenomas (≤ 25 HU). For hyperattenuating (> 25 HU) adenomas, SI-index showed higher sensitivity than ΔHU-index (66.7% [20/30] vs 40.0% [12/30], p = 0.022). CONCLUSIONS: Non-contrast spectral CT and CS-MRI outperformed conventional non-contrast CT in distinguishing lipid-poor adenomas from non-adenomas. While CS-MRI demonstrated superior sensitivity for adenomas measuring > 25 HU, non-contrast spectral CT provided high discriminative values for adenomas measuring ≤ 25 HU. CLINICAL RELEVANCE STATEMENT: Spectral attenuation analysis improves the diagnostic performance of non-contrast CT in discriminating lipid-poor adrenal adenomas, potentially serving as an alternative to CS-MRI and obviating the necessity for additional diagnostic workup in indeterminate adrenal incidentalomas, particularly for lesions measuring ≤ 25 HU. KEY POINTS: Incidental adrenal lesion detection has increased as abdominal CT use has become more frequent. Non-contrast spectral CT and CS-MRI differentiated lipid-poor adenomas from non-adenomas better than conventional non-contrast CT. For lesions measuring ≤ 25 HU, spectral CT may obviate the need for additional evaluation.

4.
Phys Eng Sci Med ; 2024 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-38884668

RESUMEN

This study aimed to evaluate the impact of radiation dose and focal spot size on the image quality of super-resolution deep-learning reconstruction (SR-DLR) in comparison with iterative reconstruction (IR) and normal-resolution DLR (NR-DLR) algorithms for cardiac CT. Catphan-700 phantom was scanned on a 320-row scanner at six radiation doses (small and large focal spots at 1.4-4.3 and 5.8-8.8 mGy, respectively). Images were reconstructed using hybrid-IR, model-based-IR, NR-DLR, and SR-DLR algorithms. Noise properties were evaluated through plotting noise power spectrum (NPS). Spatial resolution was quantified with task-based transfer function (TTF); Polystyrene, Delrin, and Bone-50% inserts were used for low-, intermediate, and high-contrast spatial resolution. The detectability index (d') was calculated. Image noise, noise texture, edge sharpness of low- and intermediate-contrast objects, delineation of fine high-contrast objects, and overall quality of four reconstructions were visually ranked. Results indicated that among four reconstructions, SR-DLR yielded the lowest noise magnitude and NPS peak, as well as the highest average NPS frequency, TTF50%, d' values, and visual rank at each radiation dose. For all reconstructions, the intermediate- to high-contrast spatial resolution was maximized at 4.3 mGy, while the lowest noise magnitude and highest d' were attained at 8.8 mGy. SR-DLR at 4.3 mGy exhibited superior noise performance, intermediate- to high-contrast spatial resolution, d' values, and visual rank compared to the other reconstructions at 8.8 mGy. Therefore, SR-DLR may yield superior diagnostic image quality and facilitate radiation dose reduction compared to the other reconstructions, particularly when combined with small focal spot scanning.

5.
Sci Rep ; 14(1): 14902, 2024 06 28.
Artículo en Inglés | MEDLINE | ID: mdl-38942790

RESUMEN

Subclinical leaflet thrombosis (SLT) can be one of the causes of transcatheter heart valve (THV) failure after transcatheter aortic valve implantation (TAVI). We sought to clarify the formation process of SLT and thrombogenicity during the perioperative period of TAVI. This multicenter, prospective, single-arm interventional study enrolled 26 patients treated with edoxaban for atrial fibrillation and who underwent TAVI for severe aortic stenosis between September 2018 and September 2022. We investigated changes in maximal leaflet thickness detected by contrast-enhanced computed tomography between 1 week and 3 months after TAVI in 18 patients and measured the thrombogenicity by Total Thrombus-formation Analysis System (T-TAS) and flow stagnation volume by computational fluid dynamics (CFD) (n = 11). SLT was observed in 16.7% (3/18) at 1 week, but decreased to 5.9% (1/17) at 3 months after TAVI. Patients with SLT at 1 week had a significantly decreased maximal leaflet thickness compared to those without SLT. Thrombogenicity assessed by T-TAS decreased markedly at 1 week and tended to increase at 3 months. The stagnation volume assessed by CFD was positively associated with a higher maximum leaflet thickness. This study showed the course of leaflet thrombus formation and visualization of stagnation in neo-sinus of THV in the acute phase after TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Fibrilación Atrial , Trombosis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Trombosis/etiología , Femenino , Masculino , Anciano de 80 o más Años , Anciano , Estudios Prospectivos , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/patología , Índice de Severidad de la Enfermedad , Piridinas/uso terapéutico , Tiazoles
6.
J Med Phys ; 49(1): 127-132, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38828063

RESUMEN

The study aimed to compare the performance of photon-counting detector computed tomography (PCD CT) with high-resolution (HR)-plaque kernel with that of the energy-integrating detector CT (EID CT) in terms of the visualization of the lumen size and the in-stent stenotic portion at different coronary vessel angles. The lumen sizes in PCD CT and EID CT images were 2.13 and 1.80 mm at 0°, 2.20 and 1.77 mm at 45°, and 2.27 mm and 1.67 mm at 90°, respectively. The lumen sizes in PCD CT with HR-plaque kernel were wider than those in EID CT. The mean degree of the in-stent stenotic portion at 50% was 69.7% for PCD CT and 90.4% for EID CT. PCD CT images with HR-plaque kernel enable improved visualization of lumen size and accurate measurements of the in-stent stenotic portion compared to conventional EID CT images regardless of the stent direction.

7.
J Am Heart Assoc ; 13(10): e034518, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38761073

RESUMEN

BACKGROUND: Although tafamidis treatment improves prognosis in patients with wild-type transthyretin amyloid cardiomyopathy, an optimal surrogate marker monitoring its therapeutic effect remains unclear. This study investigated the association between changes in cardiac biomarkers, high-sensitivity cardiac troponin T (hs-cTnT) and B-type natriuretic peptide (BNP) during the first year after tafamidis treatment and clinical outcomes. METHODS AND RESULTS: In 101 patients with wild-type transthyretin amyloid cardiomyopathy receiving tafamidis at our institution, change in cardiac biomarkers from baseline to 1 year after tafamidis administration and its association with composite outcomes (composite of all-cause death and hospitalization attributable to heart failure) was assessed. During the follow-up period (median, 17 months), 16 (16%) patients experienced composite outcomes. The hs-cTnT level significantly decreased at 1 year after tafamidis treatment, unlike the BNP level. The frequencies of increased hs-cTnT and BNP levels were significantly higher in those with composite outcomes than in those without (44% versus 15%; P=0.01). Kaplan-Meier survival analysis showed that patients in whom both hs-cTnT and BNP levels increased at 1 year after tafamidis had a higher probability of composite outcomes compared with those with decreased hs-cTnT and BNP levels (log-rank P<0.01). Cox regression analysis identified increased hs-cTnT and BNP levels at 1 year after tafamidis administration as an independent predictor of higher cumulative risk of composite outcomes. CONCLUSIONS: Deterioration in cardiac biomarkers during the first year after tafamidis treatment predicted a worse prognosis, suggesting the utility of serial assessment of cardiac biomarkers for monitoring the therapeutic response to tafamidis in patients with wild-type transthyretin amyloid cardiomyopathy.


Asunto(s)
Neuropatías Amiloides Familiares , Benzoxazoles , Biomarcadores , Cardiomiopatías , Péptido Natriurético Encefálico , Troponina T , Humanos , Masculino , Femenino , Biomarcadores/sangre , Péptido Natriurético Encefálico/sangre , Anciano , Neuropatías Amiloides Familiares/sangre , Neuropatías Amiloides Familiares/tratamiento farmacológico , Neuropatías Amiloides Familiares/mortalidad , Neuropatías Amiloides Familiares/diagnóstico , Benzoxazoles/uso terapéutico , Troponina T/sangre , Cardiomiopatías/sangre , Cardiomiopatías/tratamiento farmacológico , Cardiomiopatías/mortalidad , Cardiomiopatías/diagnóstico , Resultado del Tratamiento , Factores de Tiempo , Persona de Mediana Edad , Anciano de 80 o más Años , Insuficiencia Cardíaca/sangre , Insuficiencia Cardíaca/tratamiento farmacológico , Insuficiencia Cardíaca/mortalidad , Estudios Retrospectivos , Prealbúmina/metabolismo
8.
Artículo en Inglés | MEDLINE | ID: mdl-38718419

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate the usefulness of the injection pressure-to-injection rate (IPIR) ratio for the early detection of contrast extravasation at the venipuncture site during contrast-enhanced computed tomography. METHODS: We retrospectively enrolled 57,528 patients who underwent contrast-enhanced computed tomography examinations in a single hospital. The power injector recorded the contrast injection pressure at 0.25-second intervals. We constructed logistic regression models using the IPIR ratio as the independent variable and extravasation occurrence as the dependent variable (IPIR ratio models) at 1, 2, 3, 4, 5, and 6 seconds after the start of contrast administration. Univariate logistic regression models in which injection pressure is used as an independent variable (injection pressure models) were also constructed as a reference baseline. The performance of the models was evaluated with the area under the receiver operating characteristic curves. RESULTS: Of the 57,528 cases, 46,022 were assigned to the training group and 11,506 were assigned to the test group, which included 112 extravasation cases (0.24%) in the training group and 28 (0.24%) in the test group. The area under the receiver operating characteristic curves for the IPIR ratio models and injection pressure models were 0.555 versus 0.563 at t = 1 (P = 0.270), 0.712 versus 0.678 at t = 2 (P = 0.305), 0.758 versus 0.693 at t = 3 (P = 0.032), 0.776 versus 0.688 at t = 4 (P = 0.005), 0.810 versus 0.699 at t = 5 (P = 0.002), and 0.811 versus 0.706 at t = 6 (P = 0.002). CONCLUSIONS: The IPIR ratio models perform better in detecting contrast extravasation at 3 to 6 seconds after the start of contrast administration than injection pressure models.

9.
ESC Heart Fail ; 2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38803046

RESUMEN

AIMS: The human epididymis protein 4 (HE4), a novel fibrosis marker, is expressed only in activated fibroblasts and is thought to reflect ongoing left ventricular (LV) fibrosis. LV fibrosis is a feature of severe aortic stenosis (AS) and is related to the post-operative outcome of patients with AS. We investigated the relationship between serum levels of HE4 and the post-operative prognosis of patients with severe AS. METHODS AND RESULTS: We measured the serum HE4 levels of 55 participants (80.8 ± 8.0 years old, male n = 26, 46%) with severe AS prior to surgical aortic valve replacement (n = 31, 56%) or transcatheter aortic valve implantation (n = 24, 44%) at Kumamoto University Hospital in 2018. We followed them for cardiovascular (CV) death or hospitalization for heart failure (HF) for 3 years. Serum HE4 levels were positively correlated with computed tomography-extracellular volume (CT-ECV) values (r = 0.53, P = 0.004). Kaplan-Meier curves demonstrated a significantly higher probability of hospitalization for HF or CV-related death in the patients with high HE4 (greater than the median HE4 value) compared with the patients with low HE4 (lower than the median HE4 value) (log-rank P = 0.003). Multivariate analysis showed HE4 (log(HE4)) to be an independent prognostic factor [hazard ratio (HR): 7.50; 95% confidence interval (CI): 1.81-31.1; P = 0.005]. Receiver operating characteristic (ROC) curve analysis suggested that HE4 is a marker of increased risk of CV-related death or hospitalization for HF at 3 years after surgery, with an area under the curve (AUC) of 0.76 (95% CI: 0.62-0.90; P = 0.003). CONCLUSIONS: We found that HE4 is a potentially useful biomarker for predicting future CV events in patients scheduled for AS surgery. Measuring serum HE4 values could help consider AS surgery.

10.
Eur Heart J Open ; 4(3): oeae036, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38751455

RESUMEN

Aims: This study aims to evaluate the distribution of extracellular volume fraction detected via computed tomography, clinical characteristics of high extracellular volume fraction detected via computed tomography, and the rate of incidental detection of cardiac amyloidosis in patients undergoing cardiac computed tomography for coronary artery evaluation. Methods and results: This study included 874 consecutive patients (mean age, 74.4 ± 7.1 years; men, 65%), comprising men aged ≥60 years and women aged ≥70 years, who had undergone cardiac computed tomography between January 2020 and September 2022. The mean extracellular volume fraction detected via computed tomography was 29.7 ± 5.2%, and 108 patients (12.4%) had an extracellular volume fraction detected via computed tomography of ≥35%. Older age (75.9 ± 8.2 years vs. 74.2 ± 6.9 years; P = 0.042), male sex (75.9% vs. 63.0%; P = 0.007), impaired left ventricular ejection fraction, increased high-sensitivity cardiac troponin T and B-type natriuretic peptide levels, and increased left ventricular thickness showed significant associations with an extracellular volume fraction detected via computed tomography of ≥35%. Cardiac amyloidosis was diagnosed incidentally in 15 patients based on an increase in extracellular volume fraction detected via computed tomography. The prevalence of cardiac amyloidosis was 1.7% (15/874) and 14.3% (15/105) in the entire study population and in patients with an extracellular volume fraction detected via computed tomography of ≥35%, respectively. An increase in the extracellular volume fraction detected via computed tomography was suggestive of cardiac amyloidosis. Conclusion: Elevated extracellular volume fraction detected via computed tomography, associated with elevated cardiac biomarker levels and myocardial structural changes, may lead to the incidental diagnosis of cardiac amyloidosis.

11.
Medicine (Baltimore) ; 103(20): e38295, 2024 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-38758838

RESUMEN

To assess the diagnostic performance of unenhanced electrocardiogram (ECG)-gated cardiac computed tomography (CT) for detecting myocardial edema, using MRI T2 mapping as the reference standard. This retrospective study protocol was approved by our institutional review board, which waived the requirement for written informed consent. Between December 2017 to February 2019, consecutive patients who had undergone T2 mapping for myocardial tissue characterization were identified. We excluded patients who did not undergo unenhanced ECG-gated cardiac CT within 3 months from MRI T2 mapping or who had poor CT image quality. All patients underwent unenhanced ECG-gated cardiac CT with an axial scan using a third-generation, 320 × 0.5 mm detector-row CT unit. Two radiologists together drew regions of interest (ROIs) in the interventricular septum on the unenhanced ECG-gated cardiac CT images. Using T2 mapping as the reference standard, the diagnostic performance of unenhanced cardiac CT for detecting myocardial edema was evaluated by using the area under the receiver operating characteristic curve with sensitivity and specificity. Youden index was used to find an optimal sensitivity-specificity cutoff point. A cardiovascular radiologist independently performed the measurements, and interobserver reliability was assessed using intraclass correlation coefficients for CT value measurements. A P value of <.05 was considered statistically significant. We included 257 patients who had undergone MRI T2 mapping. Of the 257 patients, 35 patients underwent unenhanced ECG-gated cardiac CT. One patient was excluded from the study because of poor CT image quality. Finally, 34 patients (23 men; age 64.7 ±â€…14.6 years) comprised our study group. Using T2 mapping, we identified myocardial edema in 19 patients. Mean CT and T2 values for 34 patients were 46.3 ±â€…2.7 Hounsfield unit and 49.0 ±â€…4.9 ms, respectively. Mean CT values moderately correlated with mean T2 values (Rho = -0.41; P < .05). Mean CT values provided a sensitivity of 63.2% and a specificity of 93.3% for detecting myocardial edema, with a cutoff value of ≤45.0 Hounsfield unit (area under the receiver operating characteristic curve = 0.77; P < .01). Inter-observer reproducibility in measuring mean CT values was excellent (intraclass correlation coefficient = 0.93; [95% confidence interval: 0.86, 0.96]). Myocardial edema could be detected by CT value of myocardium in unenhanced ECG-gated cardiac CT.


Asunto(s)
Electrocardiografía , Tomografía Computarizada por Rayos X , Humanos , Masculino , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Electrocardiografía/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Imagen por Resonancia Magnética/métodos , Sensibilidad y Especificidad , Reproducibilidad de los Resultados , Edema/diagnóstico por imagen , Edema Cardíaco/diagnóstico por imagen , Técnicas de Imagen Sincronizada Cardíacas/métodos , Curva ROC , Adulto
12.
Quant Imaging Med Surg ; 14(4): 2870-2883, 2024 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-38617144

RESUMEN

Background: Despite advancements in coronary computed tomography angiography (CTA), challenges in positive predictive value and specificity remain due to limited spatial resolution. The purpose of this experimental study was to investigate the effect of 2nd generation deep learning-based reconstruction (DLR) on the quantitative and qualitative image quality in coronary CTA. Methods: A vessel model with stepwise non-calcified plaque was scanned using 320-detector CT. Image reconstruction was performed using four techniques: hybrid iterative reconstruction (HIR), model-based iterative reconstruction (MBIR), DLR, and 2nd generation DLR. The luminal peak CT number, contrast-to-noise ratio (CNR), and edge rise slope (ERS) were quantitatively evaluated via profile curve analysis. Two observers qualitatively graded the graininess, lumen sharpness, and overall lumen visibility on the basis of the degree of confidence for the stenosis severity using a five-point scale. Results: The image noise with HIR, MBIR, DLR, and 2nd generation DLR was 23.0, 21.0, 16.9, and 9.5 HU, respectively. The corresponding CNR (25% stenosis) was 15.5, 15.9, 22.1, and 38.3, respectively. The corresponding ERS (25% stenosis) was 203.2, 198.6, 228.9, and 262.4 HU/mm, respectively. Among the four reconstruction methods, the 2nd generation DLR achieved the significantly highest CNR and ERS values. The score of 2nd generation DLR in all evaluation points (graininess, sharpness, and overall lumen visibility) was higher than those of the other methods (overall vessel visibility score, 2.6±0.5, 3.8±0.6, 3.7±0.5, and 4.6±0.5 with HIR, MBIR, DLR, and 2nd generation DLR, respectively). Conclusions: 2nd generation DLR provided better CNR and ERS in coronary CTA than HIR, MBIR, and previous-generation DLR, leading to the highest subjective image quality in the assessment of vessel stenosis.

14.
Abdom Radiol (NY) ; 49(5): 1626-1637, 2024 05.
Artículo en Inglés | MEDLINE | ID: mdl-38456897

RESUMEN

PURPOSE: To evaluate the diagnostic performance of multiphase hepatic CT parameters (non-contrast attenuation, absolute and relative washout ratios [APW and RPW, respectively], and relative enhancement ratio [RER]) and chemical-shift MRI (CS-MRI) for discriminating lipid-poor adrenal adenomas (with non-contrast CT attenuation > 10 HU) from metastases in patients with hepatocellular carcinoma (HCC). METHODS: This retrospective study included HCC patients with lipid-poor adrenal lesions who underwent multiphase hepatic CT between January 2010 and December 2021. For each adrenal lesion, non-contrast attenuation, APW, RPW, RER, and signal-intensity index (SI-index) were measured. Each parameter was compared between adenomas and metastases. The area under the receiver operating characteristic curves (AUCs) and sensitivities to achieve 100% specificity for adenoma diagnoses were determined. RESULTS: 104 HCC patients (78 men; mean age, 71.8 ± 9.6 years) with 63 adenomas and 48 metastases were identified; CS-MRI was performed in 66 patients with 49 adenomas and 21 metastases within one year of CT. Lipid-poor adenomas showed lower non-contrast attenuation (22.9 ± 7.1 vs. 37.9 ± 9.4 HU) and higher APW (40.5% ± 12.8% vs. 23.7% ± 17.4%), RPW (30.0% ± 10.2% vs. 12.4% ± 9.6%), RER (329% ± 152% vs. 111% ± 43.0%), and SI-index (43.3 ± 20.7 vs. 10.8 ± 13.4) than HCC metastases (all p < .001). AUC for non-contrast attenuation, APW, RPW, RER, and SI-index were 0.894, 0.786, 0.904, 0.969, and 0.902, respectively. The sensitivities to achieve 100% specificity were 7.9%, 25.4%, 30.2%, 63.5%, and 24.5%, respectively. Combined RER and APW achieved the highest sensitivity of 73.0%. CONCLUSION: Multiphase hepatic CT allows for better discrimination between lipid-poor adrenal adenomas and metastases relative to CS-MRI, especially when combined with RER and washout parameters.


Asunto(s)
Neoplasias de las Glándulas Suprarrenales , Carcinoma Hepatocelular , Neoplasias Hepáticas , Imagen por Resonancia Magnética , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Masculino , Femenino , Carcinoma Hepatocelular/diagnóstico por imagen , Estudios Retrospectivos , Anciano , Imagen por Resonancia Magnética/métodos , Neoplasias de las Glándulas Suprarrenales/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Diagnóstico Diferencial , Persona de Mediana Edad , Adenoma/diagnóstico por imagen , Medios de Contraste
15.
J Vasc Interv Radiol ; 35(7): 979-988.e1, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38537737

RESUMEN

PURPOSE: To assess the different adjunctive catheter techniques required to achieve complete occlusion of renal arteriovenous malformations (rAVMs) of different angioarchitectural types. MATERIALS AND METHODS: Overall, data on 18 patients with rAVM (Type 1, n = 7; Type 2, n = 2; Type 3, n = 9; mean age, 53.8 years) who underwent 25 procedures between 2011 and 2022 were reviewed. The clinical presentations, endovascular techniques, arteriovenous malformation (AVM) occlusion rate, adverse events (including the incidence of renal infarction), and clinical symptoms and outcomes (including recurrence/increase of AVM) were analyzed according to the Cho-Do angioarchitectural classification. Posttreatment renal infarction was classified as no infarction, small infarction (<12.5%), medium infarction (12.5%-25%), and large infarction (>25%) using contrast-enhanced computed tomography or magnetic resonance imaging. RESULTS: Hematuria and heart failure were presenting symptoms in 10 and 2 patients, respectively. The embolic materials used were as follows: Type 1 rAVM, coils alone or with n-butyl-2-cyanoacrylate (nBCA); Type 2 rAVM, nBCA alone or with coils; and Type 3 rAVMs, nBCA alone. Fourteen patients underwent adjunctive catheter techniques, including flow control with a balloon catheter and multiple microcatheter placement, alone or in combination. Immediate postprocedural angiography revealed complete occlusion in 15 patients (83%) and marked regression of rAVM in 3 (17%). Small asymptomatic renal infarctions were observed in 6 patients with Type 3 rAVMs without any decrease in renal function. No major adverse events were observed. All symptomatic patients experienced symptom resolution. Recurrence/increase of rAVM was not observed during the mean 32-month follow-up period (range, 2-120 months). CONCLUSIONS: Transarterial embolization using adjunctive catheter techniques according to angioarchitectural types can be an effective treatment for rAVMs.


Asunto(s)
Malformaciones Arteriovenosas , Embolización Terapéutica , Arteria Renal , Venas Renales , Humanos , Persona de Mediana Edad , Femenino , Masculino , Embolización Terapéutica/efectos adversos , Malformaciones Arteriovenosas/terapia , Malformaciones Arteriovenosas/diagnóstico por imagen , Resultado del Tratamiento , Adulto , Estudios Retrospectivos , Anciano , Arteria Renal/diagnóstico por imagen , Arteria Renal/anomalías , Venas Renales/diagnóstico por imagen , Venas Renales/anomalías , Angiografía por Tomografía Computarizada , Valor Predictivo de las Pruebas , Recurrencia , Factores de Tiempo , Adulto Joven , Factores de Riesgo , Enbucrilato/administración & dosificación , Infarto/diagnóstico por imagen , Infarto/etiología , Infarto/terapia , Angiografía por Resonancia Magnética
16.
ESC Heart Fail ; 11(3): 1612-1624, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38400613

RESUMEN

AIMS: There are minimal data on the prognostic impact of right atrial strain during the reservoir phase (RASr) in patients with immunoglobulin light-chain (AL) cardiac amyloidosis. METHODS AND RESULTS: Among 78 patients who were diagnosed with AL cardiac amyloidosis at Kumamoto University Hospital from 2007 to 2022, 72 patients with sufficient two-dimensional speckle tracking imaging data without chemotherapy before the diagnosis were retrospectively analysed. During a median follow-up of 403 days, 31 deaths occurred. Age and the rate of male sex were not significantly different between the all-cause death group and the survival group (age, 70.4 ± 8.8 years vs. 67.0 ± 10.0 years, P = 0.14, male sex, 65% vs. 66%, P = 0.91). The estimated glomerular filtration rate (eGFR) was significantly lower, and B-type natriuretic peptide (BNP) and high sensitivity cardiac troponin T (hs-cTnT) were significantly higher, in the all-cause death group versus the survival group (eGFR, 48.2 ± 21.0 mL/min/1.73 m2 vs. 59.4 ± 24.4 mL/min/1.73 m2, P < 0.05, BNP, 725 [360-1312] pg/mL vs. 123 [81-310] pg/mL, P < 0.01, hs-cTnT, 0.12 [0.07-0.18] ng/mL vs. 0.05 [0.03-0.08] ng/mL, P < 0.01). Left ventricular (LV) global longitudinal strain (GLS) (LV-GLS), left atrial strain during the reservoir phase (LASr), right ventricular GLS (RV-GLS), and RASr were significantly lower in the all-cause death group versus the survival group (LV-GLS, 8.5 ± 4.3% vs. 11.8 ± 3.8%, P < 0.01, LASr, 8.8 ± 7.1% vs. 14.3 ± 8.1%, P < 0.01, RV-GLS, 11.6 ± 5.1% vs. 16.4 ± 3.9%, P < 0.01, RASr, 10.2 ± 7.3% vs. 20.7 ± 9.5%, P < 0.01). RASr was significantly associated with all-cause death after adjusting for RV-GLS, LV-GLS and LASr (hazard ratio [HR]: 0.91, 95% confidence interval [95% CI]: 0.83-0.99, P < 0.05). RASr and log-transformed BNP were significantly associated with all-cause death after adjusting for log-transformed troponin T and eGFR (RASr, HR: 0.93, 95% CI: 0.87-1.00, P < 0.05; log-transformed BNP, HR: 2.10, 95% CI: 1.17-3.79, P < 0.05). The optimal cut-off values were RASr: 16.4% (sensitivity: 66%, specificity: 84%, area under curve [AUC]: 0.81) and BNP: 311.2 pg/mL (sensitivity: 83%, specificity: 78%, AUC: 0.82) to predict all-cause mortality using ROC analysis. Kaplan-Meier analysis revealed that patients with low RASr (<16.4%) or high BNP (>311.2 pg/mL) had a significantly high probability of all-cause death (both, P < 0.01). We devised a new staging score by adding 1 point if RASr decreased or BNP levels increased more than each cut-off value. The HR for all-cause death using score 0 as a reference was 5.95 (95% CI: 1.19-29.79; P < 0.05) for score 1 and 23.29 (95% CI: 5.37-100.98; P < 0.01) for score 2. CONCLUSIONS: The new staging system using RASr and BNP predicted prognosis in patients with AL cardiac amyloidosis.


Asunto(s)
Cardiomiopatías , Atrios Cardíacos , Amiloidosis de Cadenas Ligeras de las Inmunoglobulinas , Humanos , Masculino , Femenino , Estudios Retrospectivos , Anciano , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/diagnóstico por imagen , Amiloidosis de Cadenas Ligeras de las Inmunoglobulinas/fisiopatología , Amiloidosis de Cadenas Ligeras de las Inmunoglobulinas/mortalidad , Pronóstico , Cardiomiopatías/fisiopatología , Cardiomiopatías/diagnóstico , Ecocardiografía/métodos , Estudios de Seguimiento , Tasa de Supervivencia/tendencias , Persona de Mediana Edad
17.
J Cardiovasc Comput Tomogr ; 18(1): 3-10, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38218665

RESUMEN

Computed tomography late enhancement (CT-LE) is emerging as a non-invasive technique for cardiac diagnosis with wider accessibility compared to MRI, despite its typically lower contrast-to-noise ratio. Optimizing CT-LE image quality necessitates a thorough methodology addressing contrast administration, timing, and radiation dose, alongside a robust understanding of extracellular volume (ECV) quantification methods. This review summarizes CT-LE protocols, clinical utility, and advances in ECV measurement through both single-energy and dual-energy CT. It also highlights photon-counting detector CT technology as an innovative means to potentially improve image quality and reduce radiation exposure.


Asunto(s)
Miocardio , Tomografía Computarizada por Rayos X , Humanos , Valor Predictivo de las Pruebas , Tomografía Computarizada por Rayos X/métodos , Corazón/diagnóstico por imagen , Imagen por Resonancia Magnética , Fantasmas de Imagen
18.
Eur Radiol ; 34(2): 1016-1025, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37597032

RESUMEN

OBJECTIVES: Myocardial extracellular volume (ECV) on computed tomography (CT), an alternative to cardiac magnetic resonance (CMR), has significant practical clinical advantages. However, the consistency between ECVs quantified via CT and CMR in cardiac amyloidosis (CA) has not been investigated sufficiently. Therefore, the current study investigated the application of CT-ECV in CA with CMR-ECV as the reference standard. METHODS: We retrospectively evaluated 31 patients with CA who underwent cardiac CT and CMR. Pearson correlation analysis was performed to investigate correlations between CT-ECV and CMR-ECV at each segment. Further, correlations between ECV and clinical parameters were assessed. RESULTS: There were no significant differences in the mean global ECVs between CT scan and CMR (51.3% ± 10.2% vs 50.0% ± 10.5%). CT-ECV was correlated with CMR-ECV at the septal (r = 0.88), lateral (r = 0.80), inferior (r = 0.79), anterior (r = 0.77) segments, and global (r = 0.87). In both CT and CMR, the ECV had a weak to strong correlation with high-sensitivity cardiac troponin T level, a moderate correlation with global longitudinal strain, and an inverse correlation with left ventricular ejection fraction. Further, the septal ECV and global ECV had a slightly higher correlation with the clinical parameters. CONCLUSIONS: Cardiac CT can quantify myocardial ECV and yield results comparable to CMR in patients with CA. Moreover, a significant correlation between CT-ECV and clinical parameters was observed. Thus, CT-ECV can be an imaging biomarker and alternative to CMR-ECV. CLINICAL RELEVANCE STATEMENT: Cardiac CT can quantify myocardial ECV and yield results comparable to CMR in patients with CA, and CT-ECV can be used clinically as an imaging biomarker and alternative to CMR-ECV. KEY POINTS: • A significant correlation was found between CT myocardial extracellular volume and cardiac MR myocardial extracellular volume in patients with cardiac amyloidosis. • In CT and cardiac MR, the myocardial extracellular volume correlated well with high-sensitivity cardiac troponin T level, global longitudinal strain, and left ventricular ejection fraction. • CT myocardial extracellular volume can be an imaging biomarker and alternative to cardiac MR myocardial extracellular volume.


Asunto(s)
Amiloidosis , Troponina T , Humanos , Volumen Sistólico , Estudios Retrospectivos , Imagen por Resonancia Cinemagnética/métodos , Función Ventricular Izquierda , Miocardio/patología , Imagen por Resonancia Magnética , Amiloidosis/diagnóstico por imagen , Biomarcadores , Valor Predictivo de las Pruebas
19.
Acad Radiol ; 31(2): 514-522, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37775448

RESUMEN

RATIONALE AND OBJECTIVES: This study aimed to assess the utility of cardiac magnetic resonance imaging (MRI) T1 and T2 mapping as quantitative imaging biomarkers in transthyretin amyloid cardiomyopathy (ATTR-CM). MATERIALS AND METHODS: This study retrospectively evaluated 74 patients with confirmed wild-type ATTR-CM who underwent cardiac MRI, 99mTc-labeled pyrophosphate (99mTc-PYP) scintigraphy, and echocardiography. We assessed the quantitative disease parameters, for example, left ventricular ejection fraction (LVEF), and global longitudinal strain (GLS) by echocardiography, native T1, extracellular volume fraction (ECV), and native T2 value by cardiac MRI, heart-to-contralateral ratio (H/CL) by 99mTc-PYP, and high-sensitive cardiac troponin T. Myocardial native T2 of ≥50 ms was defined as myocardial edema. Correlations between the disease's quantitative parameters were evaluated, and the ECV was compared to other parameters in ATTR-CM with/without myocardial edema. RESULTS: ECV in all patients with ATTR-CM revealed a strong correlation with native T1 (r = 0.62), a moderate correlation with hs-TnT (r = 0.59), LVEF (r = -0.48), GLS (r = 0.58), and H/CL (r = 0.48). Correlations between ECV and other quantitative parameters decreased in ATTR-CM with myocardial edema except for H/CL. Meanwhile, the correlations increased in ATTR-CM without myocardial edema. CONCLUSION: The presence of myocardial edema affected the interpretation of ECV assessment, although ECV can be a comprehensive imaging biomarker for ATTR-CM. ECV showed a significant correlation with various quantitative disease parameters and can be a reliable disease monitoring marker in patients with ATTR-CM when myocardial edema was excluded.


Asunto(s)
Amiloidosis , Cardiomiopatías , Humanos , Prealbúmina , Cardiomiopatías/diagnóstico por imagen , Pirofosfato de Tecnecio Tc 99m , Estudios Retrospectivos , Volumen Sistólico , Función Ventricular Izquierda , Amiloidosis/diagnóstico por imagen , Imagen por Resonancia Magnética , Edema , Biomarcadores
20.
Radiol Case Rep ; 19(2): 671-674, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38111546

RESUMEN

Pulmonary arterial hypertension associated with portal hypertension, known as portopulmonary hypertension (PoPH) is one of the important and serious pulmonary complications in patients with portal hypertension. Although there are a large number of patients with portal hypertension due to mainly liver cirrhosis, the number of cases diagnosed with PoPH are far fewer because the causes of dyspnea in patients with cirrhosis are diverse and the disease entity of PoPH is poorly recognized by clinicians. We report here the case with PoPH suggested and assessed comprehensively by dual energy computed tomography (CT) including high-resolution pulmonary CT angiography, pulmonary perfusion imaging, myocardial late iodine enhancement imaging, and myocardial extracellular volume analysis. This refined CT imaging protocol can be used in conjunction with standard chest evaluation and offers a practical and useful approach for the noninvasive "one-stop shop" evaluation of PoPH.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA