Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
J Korean Soc Radiol ; 84(5): 1185-1190, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37869117

RESUMEN

Pseudoaneurysms are among the most serious complications of percutaneous balloon angioplasty. Although pseudoaneurysm rupture rarely happens, when it does, the result can be fatal; thus, early detection and management are crucial. In this report, we disclose the case of a 34-year-old male with end-stage renal disease who presented with a huge symptomatic pseudoaneurysm of the left popliteal artery, following percutaneous balloon angioplasty three months prior. The pseudoaneurysm was successfully excluded using interventional treatment. The patient recovered well, and the follow-up was uneventful, with excellent patency of the covered stent.

2.
J Korean Soc Radiol ; 83(5): 1128-1133, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36276209

RESUMEN

Common carotid artery (CCA) rupture during parathyroid cancer surgery is extremely rare and is generally life-threatening. We present a case of successful management of a ruptured CCA following the emergency placement of stent-graft in a 59-year-old male diagnosed with recurrent parathyroid cancer. During recurrent parathyroid cancer surgery, his right CCA ruptured unexpectedly, and his vital signs deteriorated rapidly despite surgical management. After stent replacement, his unstable vital signs improved and, thereafter, he was discharged without any complications.

3.
Taehan Yongsang Uihakhoe Chi ; 81(1): 119-134, 2020 Jan.
Artículo en Coreano | MEDLINE | ID: mdl-36238116

RESUMEN

It is essential to identify the causative artery in case of active intra-abdominal or gastrointestinal bleeding. A thorough understanding of the basic arterial anatomy is required to identify the causative artery on contrast-enhanced CT angiography and conventional catheter angiography. If one is familiar with the basic arterial anatomy, obtaining access to the bleeding artery will be easier, despite the variations in the origin and course of the vessels. We describe the basic arterial anatomy that will help beginners in diagnostic radiology to identify the blood vessels that can cause active intra-abdominal or gastrointestinal bleeding.

4.
Cardiovasc Intervent Radiol ; 40(1): 99-105, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27671155

RESUMEN

PURPOSE: To evaluate the safety, feasibility, and patency rates of radiologic placement of uncovered stents for the treatment of malignant colonic obstruction proximal to the descending colon. MATERIALS AND METHODS: This was a retrospective, single-center study. From May 2003 to March 2015, 53 image-guided placements of uncovered stents (44 initial placements, 9 secondary placements) were attempted in 44 patients (male:female = 23:21; mean age, 71.8 years). The technical and clinical success, complication rates, and patency rates of the stents were also evaluated. Technical success was defined as the successful deployment of the stent under fluoroscopic guidance alone and clinical success was defined as the relief of obstructive symptoms or signs within 48 h of stent deployment. RESULTS: In total, 12 (27.3 %) patients underwent preoperative decompression, while 32 (72.7 %) underwent decompression with palliative intent. The technical success rate was 93.2 % (41/44) for initial placement and 88.9 % (8/9) for secondary placement. Secondary stent placement in the palliative group was required in nine patients after successful initial stent placement due to stent obstruction from tumor ingrowth (n = 7) and stent migration (n = 2). The symptoms of obstruction were relieved in all successful cases (100 %). In the palliative group, the patency rates were 94.4 % at 1 month, 84.0 % at 3 months, 64.8 % at 6 months, and 48.6 % at 12 months. CONCLUSIONS: The radiologic placement of uncovered stents for the treatment of malignant obstruction proximal to the descending colon is feasible and safe, and provides acceptable clinical results.


Asunto(s)
Colon Descendente/cirugía , Neoplasias Colorrectales/complicaciones , Neoplasias Colorrectales/cirugía , Obstrucción Intestinal/complicaciones , Obstrucción Intestinal/cirugía , Stents , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
5.
Vasc Endovascular Surg ; 50(4): 270-6, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-27114444

RESUMEN

PURPOSE: To evaluate the effect of an inferior vena cava (IVC) filter during aspiration thrombectomy for acute deep vein thrombosis (DVT) in the lower extremity. MATERIALS AND METHODS: From July 2004 to December 2013, a retrospective analysis of 106 patients with acute DVT was performed. All patients received an IVC filter and were treated initially with aspiration thrombectomy. Among the 106 patients, DVT extension into the IVC was noted in 27 but was not evident in 79. We evaluated the presence of trapped thrombi in the filters after the procedure. The sizes of the trapped thrombi were classified into 2 grades based on the ratio of the maximum transverse length of the trapped thrombus to the diameter of the IVC (Grades I [≤ 50%] and II [> 50%]). RESULTS: A trapped thrombus in the filter was detected in 46 (43%) of 106 patients on final venograms. The sizes of the trapped thrombi were grade I in 12 (26.1%) patients and grade II in 34 (73.9%). Among the 27 patients with DVT extension into the IVC, 20 (74.1%) showed a trapped thrombus in the filter, 75% (15 of 20) of which were grade II. Among the 79 patients without DVT extension into the IVC, 26 (32.9%) showed a trapped thrombus in the IVC filter, 73% (19 of 26) of which were grade II. CONCLUSIONS: Thrombus migration occurred frequently during aspiration thrombectomy of patients with acute DVT in the lower extremity. However, further studies are needed to establish a standard protocol for the prophylactic placement of an IVC filter during aspiration thrombectomy.


Asunto(s)
Extremidad Inferior/irrigación sanguínea , Implantación de Prótesis/instrumentación , Embolia Pulmonar/prevención & control , Trombectomía , Filtros de Vena Cava , Vena Cava Inferior , Trombosis de la Vena/terapia , Adulto , Anciano , Angiografía por Tomografía Computarizada , Femenino , Humanos , Masculino , Persona de Mediana Edad , Flebografía/métodos , Implantación de Prótesis/efectos adversos , Embolia Pulmonar/etiología , Estudios Retrospectivos , Factores de Riesgo , Trombectomía/efectos adversos , Factores de Tiempo , Resultado del Tratamiento , Vena Cava Inferior/diagnóstico por imagen , Trombosis de la Vena/complicaciones , Trombosis de la Vena/diagnóstico por imagen , Adulto Joven
9.
Cardiovasc Intervent Radiol ; 38(2): 484-7, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25005566

RESUMEN

We describe successful transumbilical retrieval of a broken umbilical venous catheter in a 37-week gestation, 2530-g female infant on her 1 day of life under fluoroscopic guidance.


Asunto(s)
Cateterismo Periférico/instrumentación , Falla de Equipo , Cuerpos Extraños/diagnóstico por imagen , Radiografía Intervencional , Venas Umbilicales/diagnóstico por imagen , Femenino , Fluoroscopía , Humanos , Recién Nacido
12.
J Vasc Interv Radiol ; 25(6): 904-10, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24685919

RESUMEN

PURPOSE: To assess the efficacy of fluoroscopic guide wire manipulation in patients with malfunctioning peritoneal dialysis (PD) catheters that were initially placed by interventional radiologists under fluoroscopic guidance. MATERIALS AND METHODS: From January 2002 to April 2012, 52 patients (mean age, 52.8 y ± 2.10s; range, 12-79 y) with malfunctioning PD catheters in whom fluoroscopic guide wire manipulation was performed were retrospectively reviewed. Technical success, clinical success, and complications were evaluated. Technical success was defined as fluoroscopically verified, successful catheter repositioning and adequate dialysate drainage after the procedure. Clinical success was defined as maintenance of PD catheter function for at least 30 days after the manipulation. RESULTS: During the study period, 72 manipulations (68 initial manipulations and 4 remanipulations) for malfunctioning PD catheters were done. The technical success rate was 74% (50 of 68) for initial manipulations and 75% (3 of 4) for remanipulations. The overall clinical success rate was 47% (32 of 68) for initial manipulations and 0% (0 of 4) for remanipulations. The primary causes of catheter malfunction were extraluminal obstruction by omental wrapping or adhesions in 43 of 68 cases (63.2%) and catheter malposition in 25 of 68 (36.8%) cases. There were no procedure-related major complications. CONCLUSIONS: Fluoroscopic guide wire manipulation in patients with malfunctioning PD catheters initially placed by interventional radiologists is a simple procedure, an effective way of prolonging PD catheter life, and a recommended procedure before invasive surgical procedures.


Asunto(s)
Obstrucción del Catéter/etiología , Catéteres de Permanencia , Falla de Equipo , Diálisis Peritoneal , Radiografía Intervencional/métodos , Adolescente , Adulto , Anciano , Niño , Diseño de Equipo , Femenino , Fluoroscopía , Humanos , Masculino , Persona de Mediana Edad , Diálisis Peritoneal/efectos adversos , Diálisis Peritoneal/instrumentación , Diálisis Peritoneal/métodos , Retratamiento , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
13.
Korean J Radiol ; 14(5): 789-96, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24043974

RESUMEN

OBJECTIVE: To evaluate the outcomes of patients undergoing percutaneous placements of a biliary stent for obstructive jaundice secondary to metastatic gastric cancer after gastrectomy. MATERIALS AND METHODS: Fifty patients (mean age, 62.4 years; range, 27-86 years) who underwent percutaneous placements of a biliary stent for obstructive jaundice secondary to metastatic gastric cancer after gastrectomy were included. The technical success rate, clinical success rate, complication rate, stent patency, patient survival and factors associated with stent patency were being evaluated. RESULTS: The median interval between the gastrectomy and stent placement was 23.1 months (range, 3.9-94.6 months). The 50 patients received a total of 65 stents without any major procedure-related complications. Technical success was achieved in all patients. The mean total serum bilirubin level, which had been 7.19 mg/dL ± 6.8 before stent insertion, decreased to 4.58 mg/dL ± 5.4 during the first week of follow-up (p < 0.001). Clinical success was achieved in 42 patients (84%). Percutaneous transhepatic biliary drainage catheters were removed from 45 patients (90%). Infectious complications were noted in two patients (4%), and stent malfunction occurred in seven patients (14%). The median stent patency was 233 ± 99 days, and the median patient survival was 179 ± 83 days. Total serum bilirubin level after stenting was an independent factor for stent patency (p = 0.009). CONCLUSION: Percutaneous transhepatic placement of a biliary stent for obstructive jaundice secondary to metastatic gastric cancer after gastrectomy is a technically feasible and clinically effective palliative procedure.


Asunto(s)
Neoplasias de los Conductos Biliares/cirugía , Conductos Biliares Extrahepáticos/cirugía , Ictericia Obstructiva/cirugía , Stents , Neoplasias Gástricas/complicaciones , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias de los Conductos Biliares/complicaciones , Neoplasias de los Conductos Biliares/secundario , Femenino , Estudios de Seguimiento , Gastrectomía , Humanos , Ictericia Obstructiva/diagnóstico , Ictericia Obstructiva/etiología , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Estudios Retrospectivos , Neoplasias Gástricas/secundario , Neoplasias Gástricas/cirugía , Resultado del Tratamiento
16.
J Thorac Imaging ; 26(4): W137-9, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21099439

RESUMEN

We describe a 75-year-old woman with previously undiagnosed situs inversus totalis with congenitally corrected transposition of the great arteries, who was admitted to the hospital due to exertional dyspnea and orthopnea. Diagnosis was made by electrocardiogram-gated 64-slice multidetector-row computed tomography.


Asunto(s)
Situs Inversus/complicaciones , Situs Inversus/diagnóstico , Transposición de los Grandes Vasos/complicaciones , Transposición de los Grandes Vasos/diagnóstico , Anciano , Electrocardiografía , Femenino , Humanos , Tomografía Computarizada Multidetector , Transposición de los Grandes Vasos/diagnóstico por imagen
18.
J Vasc Interv Radiol ; 21(8): 1244-9, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20598564

RESUMEN

PURPOSE: To evaluate the effectiveness of radiologic placement of uncovered stents for the treatment of malignant colorectal obstruction. MATERIALS AND METHODS: From May 2003 to January 2008, 116 radiologic placements of uncovered stents were attempted in 99 patients (M:F, 59:40; mean age, 65 years) with malignant colorectal obstructions. The location of stent insertion, technical and clinical success, complication rates, and patency rates of the stents in a palliative group were also evaluated. In the palliative group, the follow-up period was 2-455 days (mean, 100 +/- 129 days). RESULTS: Radiologic stent placement was technically successful in 110 of 116 cases (94.8%). Fifty cases of stent placement were preoperative (45.5%, 50 of 110) and 60 (54.5%, 60 of 110) were performed with palliative intents. In five of six failed cases, the replacement of the stent was later performed with the assistance of colonoscopy. One patient underwent an emergency operation. In 98 of 110 cases, the symptoms of obstruction were relieved, for a clinical success rate of 89.1%. Of the 50 stents that were placed successfully with preoperative intent, 44 patients underwent surgery within a mean of 10.3 days. In the palliative group, the patency rates were 89.7% at 1 month, 85.6% at 3 months, 80.8% at 6 months, and 72.7% at 12 months. CONCLUSIONS: The radiologic placement of uncovered stents for the treatment of malignant colorectal obstruction is feasible and safe and provides acceptable clinical results not only for preoperative decompression but also for palliative cases, especially in left-sided colonic obstructions.


Asunto(s)
Enfermedades del Colon/terapia , Neoplasias Colorrectales/complicaciones , Descompresión/instrumentación , Obstrucción Intestinal/terapia , Radiografía Intervencional , Enfermedades del Recto/terapia , Stents , Adulto , Anciano , Anciano de 80 o más Años , Enfermedades del Colon/diagnóstico por imagen , Enfermedades del Colon/etiología , Colonoscopía , Descompresión/efectos adversos , Femenino , Humanos , Obstrucción Intestinal/diagnóstico por imagen , Obstrucción Intestinal/etiología , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Cuidados Paliativos , Falla de Prótesis , Enfermedades del Recto/diagnóstico por imagen , Enfermedades del Recto/etiología , República de Corea , Estudios Retrospectivos , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA