Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 113
Filtrar
1.
J Maxillofac Oral Surg ; 23(5): 1138-1162, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39376783

RESUMEN

Objectives: Assess the available scientific literature regarding the direction and extent of condylar positional changes during the first year of post-surgical orthodontics interventions in class III patients. Materials and Methods: PubMed, Cochrane Library, Embase, and Google Scholar databases were searched up to March 2022 for studies involving the measurement of condylar positional changes after surgical treatment of Class III dentofacial deformity in adults with BSSO without or without Le Fort I osteotomies. The methodological index for non-randomized studies (MINORS) was utilized to assess the risk of bias and quality of non-randomized studies. Reporting of this review was based on the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Primary outcome was condyle positional changes between the following time points: T0: before treatment, T1: immediately post treatment, T2: 4, 6, or 9 months post treatment, T3: one year post treatment. Results: Nineteen studies were included in the systematic review. Eleven studies were deemed low quality, and the rest were of medium quality. The meta-analysis included 12 studies and showed statistically significant downward, outward positional changes at T1(Immediately after surgery). Inward Yaw rotation was significant at T1(1-4 month post-surgery) and T2(4-9 months post-surgery). Conclusion: Surgically induced condylar changes tend to go back to normal within the first year after surgery, except for condylar yaw rotations.

2.
ACS Omega ; 9(35): 37310-37329, 2024 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-39246493

RESUMEN

A series of novel 3,6-disubstituted pyridazine derivatives were designed, synthesized, and biologically evaluated as preclinical anticancer candidates. Compound 9e exhibited the highest growth inhibition against most of the NCI-60 cancer cell lines. The in vivo anticancer activity of 9e was subsequently investigated at two dose levels using the Ehrlich ascites carcinoma solid tumor animal model, where a reduction in the mean tumor volume allied with necrosis induction was reported without any signs of toxicity in the treated groups. Interestingly, compound 9e was capable of downregulating c-jun N-terminal kinase-1 (JNK1) gene expression and curbing the protein levels of its phosphorylated form, in parallel with a reduction in its downstream targets, namely, c-Jun and c-Fos in tumors, along with restoring p53 activity. Furthermore, molecular docking and dynamics simulations were carried out to predict the binding mode of 9e and prove its stability in the JNK1 binding pocket.

3.
BMC Oral Health ; 24(1): 712, 2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38902697

RESUMEN

OBJECTIVE: To evaluate the effects of different polishing techniques and coffee staining on the color stability of four commercially available bleach-shade composite resins, namely microhybrid, nanohybrid, nanofilled, and injectable nanohybrids. MATERIAL AND METHODS: A total of 224 discs (8 mm diameter and 2 mm thickness) were fabricated from four different bleach-shade composite resins, namely microhybrid (Gradia Direct Anterior), nanohybrid (Palfique LX5), nanofilled (Filtek Universal), and injectable nanohybrid (flowable G-aenial universal injectable). The composite resin groups were polished via four techniques: no polishing, 4-step polishing using aluminum oxide discs, 3-step polishing using silicon rubber diamond discs, and one-step polishing. Half of each group was immersed in water, while the other half was immersed in coffee for 12 days (n = 7). Colors were measured using a clinical spectrophotometer, and color differences were calculated (ΔE). The results were analyzed statistically. RESULTS: The alterations in color were significantly influenced by the techniques employed for finishing and polishing techniques, composite resin type, and degree of coffee staining. Regardless of the polishing technique and storage medium, different material types showed a significant color change (ΔE) at P < 0.001. Filtek exhibited the most significant color change, followed by Gradia and Palfique, with no significant differences between them. In addition, Different polishing techniques resulted in significant color changes (P < 0.001). The highest degree of color change was seen in the no-polishing group, followed by the 4-step and 1-step polishing groups, with negligible differences between each other. Also, Storage media had a significant effect on ΔE values. CONCLUSION: Appropriate finishing and polishing procedures can improve the color stability of bleach-shaded composite resins. Coffee has a deleterious effect on color; however, injectable flowable nanohybrid composites are more resistant to staining.


Asunto(s)
Óxido de Aluminio , Café , Color , Resinas Compuestas , Pulido Dental , Propiedades de Superficie , Resinas Compuestas/química , Pulido Dental/métodos , Óxido de Aluminio/química , Ensayo de Materiales , Espectrofotometría , Técnicas In Vitro , Humanos , Diamante/química , Nanocompuestos/química , Blanqueadores Dentales/química , Agua/química , Materiales Dentales/química , Factores de Tiempo
4.
J Prosthet Dent ; 132(1): 268.e1-268.e8, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38632027

RESUMEN

STATEMENT OF PROBLEM: Three-dimensional (3D) printing has become popular in dentistry, but studies on the influence of incorporating organic and inorganic nanofillers on 3D printed materials are lacking. PURPOSE: The purpose of this in vitro study was to assess the flexural strength, color, and antimicrobial efficacy of 3D printed photopolymerizable resin upon adding titanium dioxide nanoparticles (TiO2 NPs) and silanized chitosan nanoparticles (sCS NPs). MATERIAL AND METHODS: A stereolithographic material (VarseoSmile Crown plus; Bego) was used as a control group (VSC resin), and 3 nanocomposite resin groups were prepared by adding nanoparticles as follow: titanium dioxide group (VSC resin + 0.4% wt. TiO2 NPs), chitosan group (VSC resin + 0.4% wt. sCS NPs), and hybrid group (VSC resin + 0.2% wt. TiO2 NPs + 0.2% wt. sCS NPs). A total of 132 specimens were designed by using a free computer-aided design software program, printed, postpolymerized, and divided into 4 groups. The nanocomposite resins were characterized using scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), and Fourier-transform infrared spectroscopy (FTIR). Bar shaped specimens (n=44) were tested for 3-point flexural strength using a universal testing machine followed by the color measurement of disk-shaped specimens (n=44) with a spectrophotometer. Antimicrobial capacity was measured with Streptococcus mutans, and absorbance was measured using a microplate reader (n=44). Statistical assessments were made with 1-way ANOVA followed by the Tukey post hoc test with Bonferroni adjustment (α=.05). RESULTS: The hybrid group recorded the highest mean value of flexural strength 135.51 MPa, showing a significant difference compared with that of the control group (P=.022). Regarding color, the mean ∆E00 for titanium was 1.18, for chitosan was 4.26, and for the hybrid group was 3.23 (P<.001). The optical density of the chitosan (2.42) was significantly higher than that of the titanium 1.36 (P=.007) and that of the control 1.63 (P=.042). CONCLUSIONS: The incorporation of nanofillers resulted in an increase in flexural strength, but it adversely affected the color of nanocomposite resins. Antimicrobial efficacy was improved by incorporating titanium nanofillers.


Asunto(s)
Color , Resistencia Flexional , Nanocompuestos , Impresión Tridimensional , Titanio , Titanio/química , Nanocompuestos/química , Técnicas In Vitro , Quitosano/química , Ensayo de Materiales , Resinas Compuestas/química , Antiinfecciosos/farmacología , Nanopartículas/química , Streptococcus mutans/efectos de los fármacos , Polimerizacion , Microscopía Electrónica de Rastreo , Materiales Dentales/química , Humanos
5.
Int J Mol Sci ; 25(8)2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38674156

RESUMEN

This study investigated the association between apolipoprotein E (APOE) gene polymorphisms (rs429358 and rs7412) and primary angle-closure glaucoma (PACG) and pseudoexfoliation glaucoma (PXG) in a Saudi cohort. Genotyping of 437 DNA samples (251 controls, 92 PACG, 94 PXG) was conducted using PCR-based Sanger sequencing. The results showed no significant differences in the allele and genotype frequencies of rs429358 and rs7412 between the PACG/PXG cases and controls. Haplotype analysis revealed ε3 as predominant, followed by ε4 and ε2 alleles, with no significant variance in PACG/PXG. However, APOE genotype analysis indicated a significant association between ε2-carriers and PACG (odds ratio = 4.82, 95% CI 1.52-15.26, p = 0.007), whereas no notable association was observed with PXG. Logistic regression confirmed ε2-carriers as a significant predictor for PACG (p = 0.008), while age emerged as significant for PXG (p < 0.001). These findings suggest a potential role of ε2-carriers in PACG risk within the Saudi cohort. Further validation and larger-scale investigations are essential to elucidate the precise role of APOE in PACG pathogenesis and progression.


Asunto(s)
Apolipoproteína E2 , Predisposición Genética a la Enfermedad , Glaucoma de Ángulo Cerrado , Polimorfismo de Nucleótido Simple , Femenino , Humanos , Masculino , Alelos , Apolipoproteína E2/genética , Estudios de Casos y Controles , Frecuencia de los Genes , Genotipo , Glaucoma de Ángulo Cerrado/genética , Haplotipos , Heterocigoto , Factores de Riesgo , Arabia Saudita/epidemiología
6.
Biology (Basel) ; 13(1)2024 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-38275738

RESUMEN

Adult-onset glaucoma, an age-related neurodegenerative disease, is very prevalent among the elderly Arabs of Saudi origin. This study investigated the association between apolipoprotein E (APOE) gene variants (rs429358 and rs7412) and primary open-angle glaucoma (POAG) in Arabs of Saudi origin. A case-control genetic association study involving 179 POAG patients and 251 controls utilized Sanger sequencing to genotype APOE gene variants. The allele frequencies and genotype distributions for rs429358 and rs7412 did not show significant associations with POAG. The haplotype analysis revealed apoε3 (87.6% and 87.4%) as the most prevalent, followed by ε4 (2.8% and 3.6%) and ε2 (9.6% and 8.9%) in the controls and POAG patients, respectively. Although the ε2/ε3 genotype and ε2-carriers displayed a more than two-fold increased risk, statistical significance was not reached. Notably, these polymorphisms did not affect clinical markers, such as intraocular pressure and cup/disc ratio. The logistic regression analysis demonstrated no significant influence of age, sex, rs429358, or rs7412 polymorphisms on POAG. In conclusion, within the Saudi cohort, APOE variants (rs429358 and rs7412) do not appear to be associated with POAG and are not substantial risk factors for its development. However, additional population-based studies are required to validate these findings.

7.
Saudi J Ophthalmol ; 37(3): 211-217, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38074295

RESUMEN

PURPOSE: To investigate the impact of smart mobile phones utilization and applying Bandura's social learning theory in educating and raising awareness to glaucoma treatment compliance in primary chronic glaucoma Saudi patients, as well as examining the social learning process and determining the type of educational material (video, electronic document "brochure") with the highest efficacy in social learning as assessed by the change in Saudi patients' awareness. Finally to assess the variations contributing to chronic glaucoma patients' social learning. METHODS: A total of 150 Saudi patients with primary chronic glaucoma were recruited in our study. They were divided equally into three main groups: Control, electronic document brochure, and animated video. An electronic questionnaire was sent to them through WhatsApp twice, starting with the pretest and then after 1 week of the intervention the posttest questionnaire was sent. Results were collected for both the pretest and the posttest. The study was done at the outpatient clinic at King AbdulAziz University Hospital in Riyadh, Saudi Arabia. RESULTS: Upon comparison of the preintervention score for all groups, we found no significant difference. However, there was an improvement in the postintervention score among all groups in comparison to the preintervention score, with a statistically significant difference for the video group (P < 0.0001). Comparing the postintervention score for all groups, the video group was better than other two groups. CONCLUSION: Using mobile-based educational interventions may significantly increase patients' awareness. Both interventional methods were found to be effective in educating patients. However, video-based learning has been significantly more effective. Findings revealed that the most important factor is educational level, which enables better response to health education material.

8.
World J Clin Cases ; 11(19): 4635-4639, 2023 Jul 06.
Artículo en Inglés | MEDLINE | ID: mdl-37469722

RESUMEN

BACKGROUND: Congenital glaucoma associated with Roberts syndrome (RS) is an unusual and unique condition. No previous report describes this association. A multidisciplinary approach including molecular studies were conducted to reach the final diagnosis. CASE SUMMARY: We present a rare case of a 1-wk-old male with RS associated with bilateral congenital glaucoma, left ectopic kidney, and left-hand rudimentary digits. A comprehensive approach was applied by which bilateral non-penetrating glaucoma surgery was performed with good control of intraocular pressure for more than 6 mo. Cytogenetic and molecular testing were conducted and revealed normal measurements. CONCLUSION: This report described a case of a male baby with clinical features of RS but with a negative molecular analysis, presenting with left-hand rudimentary digits, bilateral congenital glaucoma, and left ectopic kidney. To the best of our knowledge, this is the first case reported with phocomelia, bilateral congenital glaucoma, and unilateral ectopic kidney.

9.
J Contemp Dent Pract ; 24(2): 89-96, 2023 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-37272139

RESUMEN

AIM: To compare marginal bone level (MBL) around the abutments in integrated and conventional reciprocation designs in attachment-retained removable partial prosthesis (A-RPP). MATERIALS AND METHODS: Around 14 participants were indiscriminately selected and separated into two groups. For every group, an A-RPP with one of the studied reciprocation types was fabricated and assessed. Group I received A-RPP with integrated reciprocation and group II received A-RPP with conventional reciprocation. MBL around the crowned primary and secondary abutments was assessed on the day of A-RPP insertion, at 6 and at 9 months of denture use. RESULTS: Comparison of MBL values at the primary and secondary abutments within each group showed no statistical difference from time of delivery and throughout the study. After using the A-RPP for 6 and 9 months, group I revealed lower mean values of MBL than group II which were statistically significant. CONCLUSION: Distal extension A-RPP with integrated and conventional reciprocation designs were associated with raise in bone loss. Integrated reciprocation design revealed a lesser amount of bone loss than the conventional reciprocation design and therefore, it is considered as more preferable to be used. CLINICAL SIGNIFICANCE: Distal extension A-RPP with integrated reciprocation is superior in terms of periodontium preservation around abutment teeth as compared to distal extension A-RPD with conventional reciprocation.


Asunto(s)
Implantes Dentales , Dentadura Parcial Removible , Humanos , Pilares Dentales , Análisis del Estrés Dental , Retención de Dentadura , Periodoncio
10.
PLoS One ; 18(4): e0284852, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37099569

RESUMEN

AIM: In a retrospective and exploratory case-control study, we examined the genetic association of two common polymorphisms in the 3' untranslated region (UTR) of DICER1 (rs3742330) and DROSHA (rs10719) genes in primary open-angle glaucoma (POAG) and primary angle-closure glaucoma (PACG), and its related clinical phenotypes in a Saudi cohort. METHODS: DNA genotyping was performed using TaqMan real-time PCR assays in 500 participants, including 152 POAG, 102 PACG, and 246 non-glaucomatous controls. Statistical analyses were performed to examine the association(s). RESULTS: Allele and genotype frequency of rs3742330 and rs10719 did not vary significantly in POAG and PACG compared to controls. No significant deviation was observed from Hardy-Weinberg Equilibrium (p > 0.05). Gender stratification revealed no significant allelic/genotype association with glaucoma types. Also, these polymorphisms showed no significant genotype effect on clinical markers such as intraocular pressure, cup/disc ratio, and the number of antiglaucoma medications. Logistic regression showed no effect of age, sex, rs3742330, and rs10719 genotypes on the risk of disease outcome. We also examined a combined allelic effect of rs3742330 (A>G) and rs10719 (A>G). However, none of the allelic combinations significantly affected POAG and PACG. CONCLUSIONS: The 3' UTR polymorphisms rs3742330 and rs10719 of DICER1 and DROSHA genes are not associated with POAG and PACG or its related glaucoma indices in this Middle-Eastern cohort of Saudi Arab ethnicity. However, there is a need to validate the results on a broader population and other ethnicities.


Asunto(s)
Glaucoma de Ángulo Cerrado , Glaucoma de Ángulo Abierto , Humanos , Regiones no Traducidas 3'/genética , Glaucoma de Ángulo Abierto/genética , Glaucoma de Ángulo Abierto/epidemiología , Predisposición Genética a la Enfermedad , Glaucoma de Ángulo Cerrado/genética , Estudios de Casos y Controles , Estudios Retrospectivos , Polimorfismo de Nucleótido Simple , Presión Intraocular , Ribonucleasa III/genética , ARN Helicasas DEAD-box/genética
11.
Genes (Basel) ; 14(3)2023 03 13.
Artículo en Inglés | MEDLINE | ID: mdl-36980976

RESUMEN

Polymorphisms rs2472493 near ABCA1, rs7636836 in FNDC3B, and rs61275591 near the ANKRD55-MAP3K1 genes were previously reported to exhibit genome-wide significance in primary open-angle glaucoma (POAG). Since these polymorphisms have not been investigated in the Arab population of Saudi Arabia, we examined their association with POAG in a Saudi cohort. Genotyping was performed in 152 POAG cases and 246 controls using Taqman real-time assays and their associations with POAG and clinical markers, such as intraocular pressure, cup/disc ratio, and the number of antiglaucoma medications, were tested by statistical methods. There was no association observed between POAG and the minor allele frequencies of rs2472493[G], rs7636836[T], or rs61275591[A]. None of the genetic models such as co-dominant, dominant, recessive, over-dominant, and log-additive demonstrated any genotype link. The Rs2472493 genotype showed a modest association (p = 0.044) with the number of antiglaucoma medications in the POAG group, but no significant genotype effect on post hoc analysis. In addition, a G-T allelic haplotype of rs2472493 (ABCA1) and rs7636836 (FNDC3B) did show an over two-fold increased risk of POAG (odds ratio = 2.18), albeit non-significantly (p = 0.092). Similarly, no other allelic haplotype of the three variants showed any significant association with POAG. Our study did not replicate the genetic association of rs2472493 (ABCA1), rs763683 (FNDC3B), and rs61275591 (ANKRD55-MAP3K1) in POAG and related clinical phenotypes, suggesting that these polymorphisms are not associated with POAG in a Saudi cohort of Arab ethnicity. However, large population-based multicenter studies are needed to validate these results.


Asunto(s)
Glaucoma de Ángulo Abierto , Quinasa 1 de Quinasa de Quinasa MAP , Humanos , Glaucoma de Ángulo Abierto/genética , Glaucoma de Ángulo Abierto/epidemiología , Agentes Antiglaucoma , Arabia Saudita/epidemiología , Estudios de Casos y Controles , Polimorfismo Genético , Quinasa 1 de Quinasa de Quinasa MAP/genética , Fibronectinas/genética , Transportador 1 de Casete de Unión a ATP/genética , Proteínas Portadoras/genética
12.
Sci Rep ; 13(1): 4144, 2023 03 13.
Artículo en Inglés | MEDLINE | ID: mdl-36914702

RESUMEN

To exploit the advantageous properties of approved drugs to hasten anticancer drug discovery, we designed and synthesized a series of fluoroquinolone (FQ) analogs via functionalization of the acid hydrazides of moxifloxacin, ofloxacin, and ciprofloxacin. Under the NCI-60 Human Tumor Cell Line Screening Assay, (IIIf) was the most potent among moxifloxacin derivatives, whereas (VIb) was the only ofloxacin derivative with significant effects and ciprofloxacin derivatives were devoid of activity. (IIIf) and (VIb) were further selected for five-dose evaluation, where they showed potent growth inhibition with a mean GI50 of 1.78 and 1.45 µM, respectively. (VIb) elicited a more potent effect reaching sub-micromolar level on many cell lines, including MDA-MB-468 and MCF-7 breast cancer cell lines (GI50 = 0.41 and 0.42 µM, respectively), NSCLC cell line HOP-92 (GI50 = 0.50 µM) and CNS cell lines SNB-19 and U-251 (GI50 = 0.51 and 0.61 µM, respectively). (IIIf) and (VIb) arrested MCF-7 cells at G1/S and G1, respectively, and induced apoptosis mainly through the intrinsic pathway as shown by the increased ratio of Bax/Bcl-2 and caspase-9 with a lesser activation of the extrinsic pathway through caspase-8. Both compounds inhibited topoisomerase (Topo) with preferential activity on type II over type I and (VIb) was marginally more potent than (IIIf). Docking study suggests that (IIIf) and (VIb) bind differently to Topo II compared to etoposide. (IIIf) and (VIb) possess high potential for oral absorption, low CNS permeability and low binding to plasma proteins as suggested by in silico ADME calculations. Collectively, (IIIf) and (VIb) represent excellent lead molecules for the development of cytotoxic agents from quinolone scaffolds.


Asunto(s)
Antineoplásicos , Fluoroquinolonas , Humanos , Estructura Molecular , Relación Estructura-Actividad , Fluoroquinolonas/farmacología , Moxifloxacino/farmacología , Proliferación Celular , Puntos de Control del Ciclo Celular , Antineoplásicos/química , Línea Celular Tumoral , Ciprofloxacina/farmacología , Apoptosis , Ofloxacino/farmacología , Ensayos de Selección de Medicamentos Antitumorales , Ciclo Celular
13.
J Glaucoma ; 32(5): 407-413, 2023 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-36795514

RESUMEN

PRCIS: Ultrasound cyclo plasty (UCP) can be useful in decreasing the intraocular pressure (IOP) and burden of antiglaucoma medications in eyes with primary angle closure glaucoma (PACG). Nevertheless, baselines IOP was an important determinant for failure. PURPOSE: To evaluate the intermediate-term outcomes of UCP in PACG. METHODS: This retrospective cohort study included patients with PACG who underwent UCP. The main outcome measures were IOP, number of antiglaucoma medications, visual acuity, and presence of complications. The surgical outcomes of each eye were classified as a complete success, qualified success, or failure based on the main outcome measures. Cox regression analysis was performed to identify possible predictors for failure. RESULTS: Sixty-two eyes of 56 patients were included in the study. The mean follow-up period was 28.81 months (±18.2). The IOP and number of antiglaucoma medications decreased from a mean of 23.03 (±6.4) mmHg and 3.42 (±0.9) to 15.57 (±6.4) mmHg and 2.04 (±1.3), respectively, in the 12 th month and to 14.22 (±5.0) mmHg and 1.91 (±1.5) in the 24 th month ( P <0.01 for all). The cumulative probabilities of overall success were 72.6±5.7% and 54.8±6.3% at 12 and 24 months, respectively. A high baseline IOP was associated with a higher risk of failure (hazard ratio=1.10, P =0.03). The most common complications were cataract development or progression (30.6%), rebound or prolonged anterior chamber reaction (8.1%), hypotony with choroidal detachment (3.2%), and phthisis bulbi (3.2%). CONCLUSIONS: UCP offers reasonable 2-year IOP control and reduction of the antiglaucoma medication burden. However, counseling on possible postoperative complications is needed.


Asunto(s)
Glaucoma de Ángulo Cerrado , Glaucoma , Humanos , Presión Intraocular , Glaucoma de Ángulo Cerrado/diagnóstico , Glaucoma de Ángulo Cerrado/tratamiento farmacológico , Glaucoma de Ángulo Cerrado/cirugía , Agentes Antiglaucoma , Estudios Retrospectivos , Glaucoma/cirugía , Resultado del Tratamiento , Estudios de Seguimiento
14.
Semin Ophthalmol ; 38(5): 482-489, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36762779

RESUMEN

PURPOSE: To evaluate the 2-year outcomes of ultrasound cyclo plasty (UCP) as a first procedure in glaucoma. METHODS: This retrospective cohort study included patients with uncontrolled glaucoma who underwent UCP as an initial glaucoma procedure. The main outcome measures were intraocular pressure (IOP), the number of antiglaucoma medications, visual acuity, and the presence of vision-threatening complications. Surgical outcomes of each eye were classified as either complete success, qualified success, or failure based on the main outcome measures. Differences in IOP control and success rates were compared in eyes with primary open-angle glaucoma (POAG) and primary angle-closure glaucoma (PACG). RESULTS: We included 98 eyes of 88 patients in the study. The mean follow-up period was 27.25 ± 10.1 months. At 12 and 24 months, mean IOP decreased significantly from 23.16 ± 6.4 mmHg to 16.57 ± 6.0 mmHg and 16.18 ± 5.2 mmHg, respectively, and the number of antiglaucoma medications decreased from 3.27 ± 0.9 to 1.86 ± 1.4 and 1.70 ± 1.7, respectively (p < .01 for all). There were no changes in visual acuity throughout the follow-up compared with preoperative levels. The cumulative probabilities of success were 64.3% (±4.8) [78.9% (±9.4) complete success, and 72.9% (±6.4) qualified success], and 42.9% (±5.0) [52.6% (±11.5) complete success, and 56.3% (±7.2) qualified success] at 12 and 24 months, respectively. The most common complications were cataract development/progression, anterior chamber inflammation, and macular edema. There were no significant differences in IOP, number of antiglaucoma medications, or survival rates between POAG and PACG groups. CONCLUSIONS: UCP can be used as an initial glaucoma procedure for reducing IOP and the number of antiglaucoma medications and offers comparable outcomes in POAG and PACG.


Asunto(s)
Glaucoma de Ángulo Abierto , Glaucoma , Humanos , Agentes Antiglaucoma/uso terapéutico , Estudios de Seguimiento , Glaucoma/cirugía , Glaucoma/complicaciones , Glaucoma de Ángulo Abierto/cirugía , Presión Intraocular , Estudios Retrospectivos , Resultado del Tratamiento , Agudeza Visual
15.
J Med Chem ; 66(3): 1990-2019, 2023 02 09.
Artículo en Inglés | MEDLINE | ID: mdl-36692906

RESUMEN

Sigma 2 receptor (σ2R) is overexpressed in select cancers and is regarded as a biomarker for tumor proliferation. σ2R ligands are emerging as promising theranostics for cancer and neurodegenerative diseases. Herein, we describe the design and synthesis of a series of novel quinolyl pyrazinamides as selective and potent σ2R ligands that show sub-micromolar potency in pancreatic cancer cell lines. Compounds 14 (JR1-157) and 17 (JR2-298) bind σ2R with Ki of 47 and 10 nM, respectively. Importantly, compound 14 has an oral bioavailability of 60% and shows significant in vivo efficacy without obvious toxicity in a syngeneic model of pancreatic cancer. The cytotoxicity of the quinolyl pyrazinamides significantly enhanced in the presence of copper and diminished in the presence of the copper-chelator tetrathiomolybdate. In conclusion, compound 14 is water-soluble, metabolically stable, orally active, and increases the expression of the autophagy marker LC3B and warrants further development for the treatment of pancreatic cancer.


Asunto(s)
Neoplasias Pancreáticas , Receptores sigma , Humanos , Ligandos , Pirazinamida , Cobre , Neoplasias Pancreáticas/tratamiento farmacológico , Neoplasias Pancreáticas/metabolismo , Receptores sigma/metabolismo , Neoplasias Pancreáticas
16.
BMC Oral Health ; 22(1): 567, 2022 12 03.
Artículo en Inglés | MEDLINE | ID: mdl-36463145

RESUMEN

BACKGROUND: The preparation of the implant bed has a major influence on the success rate and long-term survival of dental implants. Piezoelectric devices and special implant drilling inserts are now emerging to replace conventional drills showing improved bone response and healing around implants. The purpose of this study is to compare the piezoelectric inserts versus the traditional drills for implant site preparation. METHODS: Twelve male patients who received a total of twenty-four dental implants have been selected to participate in this split-mouth clinical trial. Each patient received two implants; one installed after piezosurgery assisted osteotomy, while the contralateral side received the implant with the original drilling protocol. The timing of surgery, implant stability, and bone density around the installed dental implants have been evaluated during a follow-up period extended to 4 months. RESULTS: a significant difference in terms of time of surgery (p < 0.005) and in implant stability at 4 months (p = 0.024) on the study side, while a non-statistical significance in terms of bone density was detected (p = 0.468). CONCLUSION: The piezoelectric implant site drilling protocol seemed to be a reliable and repeatable technique. Despite the limited sample size and lengthier operative time, the piezoelectric inserts enhanced bone quality and implant stability. Clinical trial registration Current Controlled Trials (ClinicalTrials.gov) https://clinicaltrials.gov/ct2/show/NCT05512273 ; the date of registration: 23/08/2022. Retrospectively registered.


Asunto(s)
Implantes Dentales , Piezocirugía , Humanos , Masculino , Tempo Operativo , Densidad Ósea , Boca
17.
J Clin Med ; 11(22)2022 Nov 16.
Artículo en Inglés | MEDLINE | ID: mdl-36431247

RESUMEN

Aims: To evaluate the outcomes of ultrasound cyclo plasty (UCP) for primary open-angle glaucoma (POAG) and identify the predictors of failure. Methods: This retrospective cohort study included patients with POAG who underwent UCP at King Abdul Aziz University Hospital, Riyadh, Saudi Arabia, between 2016 and 2021. The main outcome measures were the intraocular pressure (IOP), the number of antiglaucoma medications, and the presence of vision-threatening complications. The surgical outcome of each eye was based on the main outcome measures. Cox proportional hazard regression analysis was performed to identify the possible predictors of UCP failure. Results: Sixty-six eyes of fifty-five patients were included herein. The mean follow-up period was 28.95 (±16.9) months. The mean IOP decreased significantly from 23.02 (±6.1) to 18.22 (±7.0) and 16.44 (±5.3) mm Hg on the 12th and 24th months, respectively; the mean number of antiglaucoma medications decreased significantly from 3.23 (±0.9) to 2.15 (±1.5) and 2.09 (±1.6), respectively. The cumulative probabilities of overall success were 71.2 ± 5.6% and 40.9 ± 6.1% on the 12th and 24th months, respectively. High baseline IOP and the number of antiglaucoma medications were associated with a higher risk of failure (hazard ratio = 1.10 and 3.01, p = 0.04 and p < 0.01, respectively). The most common complications were cataract development or progression (30.8%) and prolonged or rebound anterior chamber reaction (10.6%). Conclusions: UCP reasonably controls the IOP and reduces the antiglaucoma medication burden in eyes with POAG. Nevertheless, the success rate is modest, with a high baseline IOP and number of medications.

18.
Biomed Res Int ; 2022: 2805343, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36065254

RESUMEN

Objective: This study is aimed at determining two main points. First, if the Canary System™ (CS), initially used to assess caries, can measure a decalcification depth of bleached enamel quantitatively, and second, whether or not whitening has a harmful effect on enamel. This device can be considered a useful tool in the clinical assessment of the progression of demineralization after bleaching. Materials and Methods: This study collected sixty human premolars that are in a good state recently extracted for orthodontic reason. To properly disinfect and preserve the premolars, they were stored in a saline solution and later in distilled water for a period of two weeks to allow the premolars to rehydrate. Later, 24 hours before the experiment, the premolars were introduced into a solution of artificial saliva to acquire back their minerals. The mineral content of the teeth was measured by the Canary System™ before bleaching. The teeth were bleached with 30% hydrogen peroxide (fläsh HP 30%), 30 min per week and for 3 consecutive weeks to simulate the conditions of strong bleaching in the clinic. The extent of demineralized enamel was measured by the Canary System™ at three points on the enamel surface of each tooth. The data were averaged for each application of the bleaching product. The demineralization extent of the teeth was measured by the Canary System™ before and after bleaching. The significance level was set at 0.05, and SPSS version 26 was used. The data were analyzed by using Wilcoxon's and Student's tests. Results: Mineral loss occurred after the first bleaching session; the Canary System™ detected a decalcification in the first bleaching session (532 ± 322 µm) compared to the other sessions (p ≤ 0.05), while no significant change was detected between the second and the third sessions (p > 0.05). Conclusion: Based on the findings of the present study, under in vitro conditions, it was possible to measure the demineralization extent of bleached enamel with the Canary System™.


Asunto(s)
Blanqueamiento de Dientes , Esmalte Dental , Humanos , Peróxido de Hidrógeno , Ácido Hipocloroso , Minerales , Saliva Artificial , Compuestos de Sodio , Blanqueamiento de Dientes/efectos adversos
19.
J Glaucoma ; 31(10): 834-838, 2022 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-35882024

RESUMEN

PRCIS: UCP offers reasonable IOP control and reduction of the antiglaucoma medication burden. PURPOSE: The purpose of this study is to evaluate the 2-year outcomes of Ultrasound Cyclo Plasty (UCP) in uncontrolled glaucoma. MATERIALS AND METHODS: A retrospective cohort study included patients with uncontrolled primary or secondary glaucoma who underwent UCP at King Abdul Aziz University Hospital, Riyadh, Saudi Arabia, between 2016 and 2021. The main outcome measures were intraocular pressure (IOP), number of antiglaucoma medications, and presence of vision-threatening complications. The surgical outcome of each eye was classified as complete success, qualified success, or failure based on the main outcome measures. RESULTS: One hundred and eighty-two eyes of 158 patients were included in the study. The mean follow-up period was 29.71 months (±18.1). The IOP and the number of antiglaucoma medications decreased significantly from a mean of 23.46 mm Hg (±6.3) and 3.33 (±0.9) to 17.33 (±7.1) and 2.14 (±1.4), and 16.24 (±6.3) and 1.90 (±1.5) on the 12th and 24 months, respectively. The overall success rates were 78.0% (143/182) and 85.6% (95/111), and the failure rates were 21.4% (39/182) and 14.4% (16/111) on the 12th and 24th months, respectively. The most common complications were cataract development/progression and anterior chamber reaction. CONCLUSIONS: UCP offers reasonable IOP control and reduction of the antiglaucoma medication burden.


Asunto(s)
Glaucoma , Presión Intraocular , Agentes Antiglaucoma , Estudios de Seguimiento , Glaucoma/diagnóstico , Glaucoma/cirugía , Humanos , Estudios Retrospectivos , Resultado del Tratamiento
20.
Front Genet ; 13: 877174, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35719397

RESUMEN

Objective: It is plausible that common disease mechanisms exist in glaucoma pathophysiology. Accordingly, we investigated the genetic association of two previously reported primary open-angle glaucoma (POAG)-related gene polymorphisms, rs2472493 (A > G) in ABCA1 and rs7636836 (C > T) in FNDC3B, in primary angle-closure glaucoma (PACG) and pseudoexfoliation glaucoma (PXG). Methods: TaqMan genotyping was performed in a total of 442 subjects consisting of 246 healthy controls, 102 PACG patients, and 94 PXG patients. Statistical evaluations were performed to detect allelic and genotype association of the variants with the disease and clinical variables such as intraocular pressure (IOP) and cup/disc ratio. Results: Overall, there was no allelic or genotype association of these variants in PACG and PXG. However, rs7636836[T] allele significantly increased the risk of PXG among men (p = 0.029, odds ratio [OR] = 2.69, 95% confidence interval = 1.11-6.51). Similarly, rs2472493 and rs7636836 genotypes also showed significant association with PXG among men in over-dominant model (p = 0.031, OR = 1.98, 95% CI = 1.06-3.71) and co-dominant model (p = 0.029, OR = 2.69, 95% CI = 1.11-6.51), respectively. However, none survived Bonferroni's correction. Besides, the synergic presence of rs2472493[G] and rs7636836[T] alleles (G-T) was found to significantly increase the risk of PACG (p = 0.026, OR = 2.85, 95% CI = 1.09-7.46). No significant genotype influence was observed on IOP and cup/disc ratio. Conclusion: Our results suggest that the polymorphisms rs2472493 in ABCA1 and rs7636836 in FNDC3B genes may be associated with PXG among men, and a G-T allelic combination may confer an increased risk of PACG in the middle-eastern Saudi cohort. Further research in a larger population-based sample is needed to validate these findings.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA