Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Semin Thorac Cardiovasc Surg ; 33(2): 328-334, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-32853740

RESUMEN

Quality of life and patient satisfaction after ministernotomy have never been compared to conventional full sternotomy in randomized trials. The QUALITY-AVR trial is a single-blind, single-center, independent, randomized clinical trial comparing ministernotomy to full sternotomy in patients with isolated severe aortic stenosis scheduled for elective aortic valve replacement. One hundred patients were randomized in a 1:1 computational fashion. The primary endpoint was a difference between intervention groups of ≥0.10 points in change from baseline quality of life Questionnaire EuroQOL-index, measured at 1, 6, or 12 months. Secondary endpoints were differences in change from other baseline EuroQOL-index utilities, cardiac surgery-specific satisfaction questionnaire (SATISCORE), a combined safety endpoint of 4 major adverse complications at 1 month (all-cause mortality, acute myocardial infarction, neurologic events, and acute renal failure), bleeding through drains within the first 24 hours, intubation time, and other minor endpoints. Clinical follow-up was scheduled at baseline, 1, 6, and 12 months after randomization. Change from baseline mean difference EQ-5D-index was +0.20 points (95% confidence interval 0.10-0.30, P < 0.001) and median difference +0.14 (95% confidence interval 0.06-0.22, P < 0.001), favoring the ministernotomy group at 1 month. Patient satisfaction was also better at 1 month (Satiscore 83 ± 9 vs 77 ± 13 points; P = 0.010). The ministernotomy group had significantly less bleeding in the first 24 hours (299 ± 140 vs 509 ± 251 mL, P = 0.001). Ministernotomy provides a faster recovery with improved quality of life and satisfaction at 1 month compared to full sternotomy.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Procedimientos Quirúrgicos Mínimamente Invasivos , Calidad de Vida , Método Simple Ciego , Esternotomía/efectos adversos , Resultado del Tratamiento
2.
Heart Surg Forum ; 23(6): E763-E769, 2020 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-33234222

RESUMEN

BACKGROUND: Isolated tricuspid valve surgery is a rarely performed procedure and traditionally is associated with a bad prognosis, although its clinical outcomes still are little known. The aim of this study was to assess the short- and long-term clinical outcomes obtained at our center after isolated tricuspid valve surgery as treatment for severe tricuspid regurgitation. METHODS: This retrospective study included 71 consecutive patients with severe tricuspid regurgitation who underwent isolated tricuspid valve surgery between December 1996 and December 2017. Perioperative and long-term mortality, tricuspid valve reoperation, and functional class were analyzed after follow up. RESULTS: Regarding surgery, 7% of patients received a De Vega annuloplasty, 14.1% an annuloplasty ring, 11.3% a mechanical prosthesis, and 67.6% a biological prosthesis. Perioperative mortality was 12.7% and no variable was shown to be predictive of this event. After a median follow up of 45.5 months, long-term mortality was 36.6%, and the multivariate analysis identified atrial fibrillation as the only predictor (Hazard Ratio 3.014, 95% confidence interval 1.06-8.566; P = 0.038). At the end of follow up, 63.6% of survivors had functional class I. CONCLUSIONS: Isolated tricuspid valve surgery was infrequent in our center. Perioperative mortality was high, as was long-term mortality. However, a high percentage of survivors were barely symptomatic after follow up.


Asunto(s)
Anuloplastia de la Válvula Cardíaca/métodos , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Tricúspide/cirugía , Válvula Tricúspide/cirugía , Anciano , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Reoperación , Estudios Retrospectivos , Factores de Riesgo , España/epidemiología , Tasa de Supervivencia/tendencias , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/diagnóstico , Insuficiencia de la Válvula Tricúspide/mortalidad
3.
Trials ; 19(1): 114, 2018 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-29454380

RESUMEN

BACKGROUND: During the last decade, the use of ministernotomy in cardiac surgery has increased. Quality of life and patient satisfaction after ministernotomy have never been compared to conventional full sternotomy in randomised trials. The aim of the study is to determine if this minimally invasive approach improves quality of life, satisfaction and clinical morbimortality outcomes. METHODS/DESIGN: The QUALITY-AVR trial is a single-blind, single-centre, independent, and pragmatic randomised clinical trial comparing ministernotomy ("J" shaped upper hemisternotomy toward right 4th intercostal space) to full sternotomy in patients with isolated severe aortic stenosis scheduled for elective aortic valve replacement. One hundred patients will be randomised in a 1:1 computational fashion. Sample size was determined for the primary end point with alpha error of 0.05 and with power of 90% in detecting differences between intervention groups of ≥ 0.10 points in change from baseline quality of life Questionnaire EuroQOL-index (EQ-5D-5 L®), measured at 1, 6 or 12 months. Secondary endpoints are: the differences in change from other baseline EQ-5D-5 L® utilities (visual analogue scale, Health Index and Severity Index), cardiac surgery specific satisfaction questionnaire (SATISCORE®), a combined safety endpoint of four major adverse complications at 1 month (all-cause mortality, acute myocardial infarction, neurologic events and acute renal failure), bleeding through drains within the first 24 h, intubation time, postoperative hospital and intensive care unit length of stay, transfusion needs during the first 72 h and 1-year survival rates. Clinical follow up is scheduled at baseline, 1, 6, and 12 months after randomization. All clinical outcomes are recorded following the Valve Academic Research Consortium 2 criteria. DISCUSSION: The QUALITY-AVR trial aims to test the hypothesis that ministernotomy improves quality of life, satisfaction and clinical outcomes in patients referred for isolated aortic valve replacement. Statistically significant differences favouring ministernotomy could modify the surgical "gold standard" for aortic stenosis surgery, and subsequently the need to change the control group in transcatheter aortic valve implantation trials. Recruitment started on 18 March 2016. In November 2017, 75 patients were enrolled. TRIAL REGISTRATION: ClinicalTrials.gov , NCT02726087 . Registered on 13 March 2016.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Satisfacción del Paciente , Calidad de Vida , Esternotomía/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Humanos , Procedimientos Quirúrgicos Mínimamente Invasivos , Complicaciones Posoperatorias/etiología , Ensayos Clínicos Pragmáticos como Asunto , Índice de Severidad de la Enfermedad , Método Simple Ciego , España , Esternotomía/efectos adversos , Encuestas y Cuestionarios , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA