Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
1.
J Vasc Interv Radiol ; 2024 Aug 24.
Artículo en Inglés | MEDLINE | ID: mdl-39187125

RESUMEN

PURPOSE: To assess compare the efficacy effectiveness and safety of percutaneous microwave ablation (MWA) for subdiaphragmatic versus non-subdiaphragmatic colorectal liver metastasis (CLM). MATERIALS AND METHODS: This is a retrospective analysis of a prospectively created microwave ablation (MWA) database, from two prospective clinical trials for CLM patients treated in a single-tertiary center from 2012-2023. Subdiaphragmatic CLM was defined as a tumor located <1 cm from the diaphragm. Minimal Ablation Margin (MM) was calculated with 3D software using the post-ablation contrast enhanced CT. Adverse events were assessed with SIR classification for 6 months. RESULTS: 209 CLMs underwent 191 MWA sessions in 143 patients. Mean tumor diameter was 1.52±0.53 cm. 83/209(39.7%) CLMs were subdiaphragmatic. There was no difference in local tumor progression-free survival (LTPFS) between subdiaphragmatic and non-subdiaphragmatic CLMs (HR:0.65,95%CI:0.37-1.16, p=0.15). MM of 5-10 mm, and >10 mm was documented in 49.3% vs 46.8%, (p=0.83) and in 21.6% vs12.6% (p=0.16) for subdiaphragmatic and non-subdiaphragmatic CLMs.12-month LTPFS was similar between groups (HR:0.65,95%CI:0.37-1.16, p=0.15) without LTP for MM >10mm. There were 3 grade IV adverse events: one diaphragmatic perforation, one liver abscess and one biloma. Pneumothorax was associated with subdiaphragmatic location (p<0.001) and transpulmonary approach (p<0.001). Median hospital stay was 2 days (IQR: 1-3) for patients necessitating thoracostomy (n=20, 9.6%) compared to 1 day for those that did not (IQR: 1-8) without long-term sequelae. CONCLUSION: MWA of subdiaphragmatic CLM is effective and safe, without difference in success and 12-month LTPFS. Pneumothorax was associated with subdiaphragmatic location and thoracostomy that resulted in longer hospitalization without long-term sequelae.

2.
Eur Urol Oncol ; 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39095299

RESUMEN

BACKGROUND AND OBJECTIVE: The source of tissue for genomic profiling of metastatic castration-resistant prostate cancer (mCRPC) is often limited to osseous metastases. To guide patient management, metastatic site selection and the technique for targeted bone biopsies are critical for identifying deleterious gene mutations. Our objective was to identify key parameters associated with successful large-panel DNA sequencing. METHODS: We analyzed parameters for 243 men with progressing mCRPC who underwent 269 bone biopsies for genomic profiling between 2014 and 2018. Univariate and multivariate analyses were performed for clinical, imaging (bone scan; fluorodeoxyglucose [FDG] positron emission tomography [PET]; computed tomography [CT]; magnetic resonance imaging), and technical (biopsy site, number of samples, needle gauge) features associated with successful genomic profiling. KEY FINDINGS AND LIMITATIONS: Overall, 159 of 269 biopsies (59%) generated sufficient tumor material for a genomic profile. Seventy (26%) of the failures were histopathologically negative for mCRPC and 40 (15%) had insufficient tumor for genomic profiling. Of 199 mCRPC samples submitted for molecular testing, 159 (80%) yielded a genomic profile. On univariate analysis, PSA, serum acid phosphatase, number of biopsy samples, FDG PET positivity, CT attenuation, and CT morphology were significantly associated with genomic profiling success. On multivariate analysis, higher FDG maximum standardized uptake value (odds ratio [OR] 7.51, 95% confidence interval [CI] 3.01-18.78; p < 0.001), higher number of biopsy samples (OR 4.73, 95% CI 1.49-15.02; p = 0.008), and lower mean CT attenuation (OR 0.4, 95% CI 0.18-0.89; p = 0.025) were significantly associated with sequencing success. CONCLUSIONS AND CLINICAL IMPLICATIONS: In patients with mCRPC, bone biopsies from sites with metabolic activity and lower CT attenuation are associated with higher success rates for genomic profiling via a large-panel DNA sequencing platform. PATIENT SUMMARY: We identified factors associated with successful genetic testing of bone tissue for patients with metastatic prostate cancer. Our findings may help in guiding the right scan technique and biopsy site for personalized treatment planning.

3.
Surg Oncol ; 55: 102102, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38970935

RESUMEN

OBJECTIVES: Assess safety and efficacy of thermal ablation for adrenal metastases (AM) secondary to non-small cell lung cancer (NSCLC). MATERIALS AND METHODS: This retrospective study included patients with NSCLC AM treated with thermal ablation between 2/2010-11/2021. Local tumor progression free survival (LTPFS) and overall survival (OS) were calculated using Kaplan-Meier method. Adverse events were graded using Common Terminology Criteria for Adverse Events v5. RESULTS: Seven patients (mean age ± SD, 63.9 ± 12.5 years; 6 males) with seven AM were treated in eight sessions. Retreatment was performed in one patient with residual disease. Five sessions were with microwave ablation and 3 with radiofrequency ablation. Mean tumor size was 20.1 ± 7.0 mm. Median number of ablation probes used was 1 (range, 1-5), with a median of 3 activations (range, 1-3), and average ablation time of 14.4 ± 15.0 minutes. Response based on RECIST v 1.1 or PERCIST criteria revealed stable disease in 1 tumor, progression of disease in 3 tumors (one was re-ablated), and partial response in 3 tumors. Median LTPFS was not reached (NR) [95 % CI: 1- NR]. Median OS was 47.97 months (95 % CI: 18.63- NR). Intraprocedural hypertension (blood pressure ≥180 mmHg) occurred during 5/8 (62.5 %) sessions and intraoperative tachycardia occurred during 2/8 (25 %) sessions. Complications within one month of ablation occurred in 3/8 (37.5 %) sessions: grade 2 pneumothorax, grade 1 hematuria, and grade 2 adrenal insufficiency. CONCLUSIONS: In this small series, thermal ablation for NSCLC AM resulted in prolonged local control and OS with no major complications.


Asunto(s)
Neoplasias de las Glándulas Suprarrenales , Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Humanos , Masculino , Persona de Mediana Edad , Femenino , Neoplasias de las Glándulas Suprarrenales/secundario , Neoplasias de las Glándulas Suprarrenales/cirugía , Neoplasias de las Glándulas Suprarrenales/patología , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/cirugía , Neoplasias Pulmonares/secundario , Estudios Retrospectivos , Anciano , Tasa de Supervivencia , Carcinoma de Pulmón de Células no Pequeñas/patología , Carcinoma de Pulmón de Células no Pequeñas/cirugía , Carcinoma de Pulmón de Células no Pequeñas/secundario , Estudios de Seguimiento , Pronóstico , Ablación por Radiofrecuencia/métodos , Ablación por Radiofrecuencia/efectos adversos , Ablación por Catéter/métodos , Ablación por Catéter/efectos adversos
4.
Acad Radiol ; 2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38702213

RESUMEN

PURPOSE: The purpose of this study was to evaluate the technical and clinical success of middle meningeal artery (MMA) embolization performed for symptomatic subacute subdural hematoma (SDH) in patients with cancer. METHODS: This study retrospectively included 23 consecutive patients (12 men, 11 women; median age 61 years, interquartile range: 55.5-75.5) who underwent 34 MMA angiograms for symptomatic SDH in 2022 and 2023. Median SDH thickness was 10.5 mm (7-12). Median platelet count was 117 K/mcL (54.5-218). 10 patients (43.5%, 10/23) had hematologic malignancies, seven patients (30.4%, 7/23) had surgery. Fluoroscopy time (FT), reference dose (RD), and kerma area product (Kap) were analyzed. Adverse events and outcomes were recorded. RESULTS: The median imaging and clinical follow-up were 65 days (36.5-190.5) and 163 days (86-274), respectively. The technical success rate was 91.2% (31/34) as three MMA were not identified in two patients. Median procedure duration was 61 min (55.5-75.5). Median FT was 21.6 min (15.5-31.8); median RD was 158 mGy (96-256); and median Kap was 32.9 Gy.cm2 (20.4-45.1). No further intervention was needed. For 16 patients, SDH resolved after in median 59.5 days (50-90). For seven patients, SDH remained visible on the last imaging follow-up performed at 24 days in median (6.5-36.5). No predictive factor of failure was identified. The adverse event rate was 1/23 (4.3%). Eight patients (34.8%, 8/23) died during follow-up from progression of cancer. CONCLUSION: MMA embolization of symptomatic SDH in patients with cancer appears safe and is associated with improvement in clinical symptoms.

5.
J Vasc Interv Radiol ; 35(6): 883-889, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38789205

RESUMEN

PURPOSE: To investigate the safety and effectiveness of intranodal lymphangiography (INL) and lymphatic embolization (LE) in management of chylous ascites after oncologic surgery. MATERIALS AND METHODS: Retrospective review of records of patients who underwent INL with or without LE from January 2017 to June 2022 was performed. Adult patients with chylous ascites after oncologic surgery referred to interventional radiology after failure of conservative treatment were included. Thirty-nine patients who underwent 55 procedures were included (34 males and 5 females). Data on patient demographics, procedural technique, outcomes, and follow-up were collected. Descriptive statistics were used to illustrate technical success, clinical success, and adverse events. Univariate logistic regression analysis was performed to evaluate factors predicting clinical success. RESULTS: INL was technically successful in 54 of 55 procedures (98%; 95% confidence interval [CI], 90%-100%). A lymphatic leak was identified in 40 procedures, and LE was attempted in 36. LE was technically successful in 33 of the 36 procedures (92%; 95% CI, 78%-98%). Clinical success, defined as resolution of ascites with no need for peritoneovenous shunt placement or additional surgery, was achieved in 22 of 39 patients (56%; 95% CI, 40%-72%). Clinical success was achieved in 18 patients after 1 procedure, and patients who required repeat procedures were less likely to achieve clinical success (odds ratio, 0.16; 95% CI, 0.04-0.66; P = .012). Four grade 1 procedural adverse events were recorded. CONCLUSIONS: INL with or without LE is a safe minimally invasive tool that can help patients with chylous ascites after oncologic surgery who failed conservative treatment avoid more invasive interventions.


Asunto(s)
Ascitis Quilosa , Embolización Terapéutica , Enfermedad Iatrogénica , Linfografía , Valor Predictivo de las Pruebas , Humanos , Ascitis Quilosa/etiología , Ascitis Quilosa/terapia , Ascitis Quilosa/diagnóstico por imagen , Masculino , Femenino , Estudios Retrospectivos , Embolización Terapéutica/efectos adversos , Persona de Mediana Edad , Anciano , Resultado del Tratamiento , Adulto , Neoplasias/cirugía , Neoplasias/complicaciones , Factores de Riesgo , Radiografía Intervencional/efectos adversos , Anciano de 80 o más Años , Factores de Tiempo
6.
Eur J Radiol ; 175: 111465, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38621339

RESUMEN

PURPOSE: Assess safety and local tumor progression-free survival (LTPFS) of percutaneous cryoablation for pleural-based thoracic malignancies. MATERIALS AND METHODS: Retrospective study of 46 patients (17 treated for palliation; 9 for oligoprogression; 20 for curative intent), with 62 pleural-based thoracic lesions, treated in 59 cryoablation sessions. Patients were treated from 9/2005-11/2021 with CryoCare CS (Varian, Irvine, CA) or IceFORCE (Boston Scientific, Marlborough, MA) systems. For tumors treated with curative intent and/or oligoprogression, LTPFS of the treated tumor(s) and overall survival (OS) were estimated using Kaplan-Meier method. Post-operative complications were reported for all sessions, including those with palliative intent; univariate analyses were used to calculate factors associated with increased complication risk. RESULTS: Median number of tumors treated in a single treatment session was 1 (range 1-4). Largest dimension of the treated tumor was 2.1 cm [IQR:0.9-5 cm]. Of the 59 treatments, 98.3 % were technically successful. Median LTPFS was 14.4 (95 % CI: 9.4-25.6) months. Tumor size was a significant predictor of LTPFS (HR: 1.21, 95 % CI: 1.03-1.44, p = 0.023). Median OS was 52.4 (28.1-NR) months. Complications occurred in 28/59 sessions (47.5 %); 2/59 (3.4 %) were ≥ grade D by Society of Interventional Radiology adverse event criteria (death; hypoxia requiring supplemental oxygen upon discharge). Pain and pneumothorax were the most common complications. The length of lung parenchyma traversed was a significant predictor of pneumothorax: HR 0.48 (95 %CI: 0.14-0.83), p = 0.0024. CONCLUSION: Percutaneous cryoablation for pleural lesions is associated with a long duration of local control and most complications were minor and self-limited.


Asunto(s)
Criocirugía , Neoplasias Pleurales , Humanos , Criocirugía/métodos , Criocirugía/efectos adversos , Masculino , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Anciano , Resultado del Tratamiento , Neoplasias Pleurales/cirugía , Adulto , Anciano de 80 o más Años , Complicaciones Posoperatorias , Tasa de Supervivencia
7.
Can Assoc Radiol J ; 75(4): 907-920, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38581355

RESUMEN

Objectives: This systematic review aims to assess existing research concerning the use of robotic systems to execute percutaneous lung biopsy. Methods: A systematic review was performed and identified 4 studies involving robotic systems used for lung biopsy. Outcomes assessed were operation time, radiation dose to patients and operators, technical success rate, diagnostic yield, and complication rate. Results: One hundred and thirteen robot-guided percutaneous lung biopsies were included. Technical success and diagnostic yield were close to 100%, comparable to manual procedures. Technical accuracy, illustrated by needle positioning, showed less frequent needle adjustments in robotic guidance than in manual guidance (P < .001): 2.7 ± 2.6 (range 1-4) versus 6 ± 4 (range 2-12). Procedure time ranged from comparable to reduced by 35% on average (20.1 ± 11.3 minutes vs 31.4 ± 10.2 minutes, P = .001) compared to manual procedures. Patient irradiation ranged from comparable to reduced by an average of 40% (324 ± 114.5 mGy vs 541.2 ± 446.8 mGy, P = .001). There was no significant difference in reported complications between manual biopsy and biopsies that utilized robotic guidance. Conclusion: Robotic systems demonstrate promising results for percutaneous lung biopsy. These devices provide adequate accuracy in probe placement and could both reduce procedural duration and mitigate radiation exposure to patients and practitioners. However, this review underscores the need for larger, controlled trials to validate and extend these findings.


Asunto(s)
Pulmón , Procedimientos Quirúrgicos Robotizados , Humanos , Pulmón/diagnóstico por imagen , Pulmón/patología , Procedimientos Quirúrgicos Robotizados/métodos , Biopsia Guiada por Imagen/métodos , Biopsia Guiada por Imagen/instrumentación , Biopsia con Aguja/métodos , Biopsia con Aguja/instrumentación , Enfermedades Pulmonares/patología , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/diagnóstico por imagen
8.
Br J Radiol ; 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38588564

RESUMEN

OBJECTIVES: To assess the safety and efficacy of percutaneous cryoablation (CA) of soft-tissue tumors (desmoid tumors (DT), vascular malformations (VM), and abdominal wall endometriosis (AWE)). METHODS: This systematic review of studies published before January 2024 encompassed a detailed analysis of CA techniques and technical aspects for the treatment of soft-tissue tumors. Data concerning CA efficacy, complication rates, and other relevant metrics was extracted and included for analysis. RESULTS: The analysis included 27 studies totaling 554 CA procedures. For DT (13 studies, 393 sessions), CA showed an average pain reduction of 79 ± 17% (range: 57-100) and a lesion volume decrease of 71.5 ± 9.8% (range: 44-97). VM (4 studies, 58 sessions) had a 100% technical success rate and an average pain reduction of 72 ± 25% (range: 63-85). The average pain reduction for AWE (6 studies, 103 sessions) was 82 ± 13% (range: 62-100). Overall, the complication rate for CA was low, with minor adverse events (AE) in about 20% of patients and major events in less than 5% of patients. CONCLUSION: Showing substantial efficacy in pain reduction and lesion volume decrease, as well as low incidence of severe AE, CA presents as a highly effective and safe alternative for the treatment of soft-tissue tumors. ADVANCES IN KNOWLEDGE: CA is effective and safe in treating soft-tissue tumors, particularly DT, VM, and AWE.

9.
J Vasc Interv Radiol ; 35(7): 1012-1021.e1, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38670528

RESUMEN

PURPOSE: To evaluate the histopathologic changes and potential correlations of tumor absorbed dose (TAD) after yttrium-90 transarterial radioembolization (TARE) for colorectal liver metastases (CLMs). MATERIALS AND METHODS: This prospective pilot study assessed 12 patients with 13 CLMs through positron emission tomography (PET)/computed tomography (CT)-guided biopsies before, immediately after TARE (T0), and 3 weeks after TARE (T3). Subsequent sampling from the same location was enabled by fiducial placement. Biopsy samples were evaluated with hematoxylin and eosin, TUNEL, Ki67, OxPhos, caspase-3 (CC3), and pH2AX antibodies. Proliferation changes (Ki67) and double-strand DNA breaks (DSBs) were evaluated quantitatively. TAD was calculated on post-TARE PET/CT scan of the biopsy needle location at T0 and T3. RESULTS: Median TAD at 3 weeks after TARE was 162 Gy (interquartile range (IQR), 92-211 Gy). DSBs decreased significantly from T0 (median, 77%; IQR, 75%-100%) to T3 (median, 14%; IQR, 0%-54%; P = .028). A decrease in Ki67 was also documented (median, 73%; IQR, 70%-80% at T0 vs median, 41%; IQR, 0%-66% at T3; P = .046). There was a strong positive correlation between TAD and DSBs at T0 (r[9] = 0.68) and a strong negative correlation at T3 (r[10] = -0.855; P = .042 and P = .002, respectively). There was a strong negative correlation between TAD and Ki67 at both T0 (r[9] = -0.733; P = .025) and T3 (r[10] = -0.681; P = .030). Tumors that exhibited caspase-3 activation (8/13, 62%) at either T0 or T3 time point were more likely to develop progression (7/8 [88%] vs 1/5 [20%]; P = .015). CONCLUSIONS: Post-TARE biopsy can be used to assess TAD and histopathologic changes. Significant decreases in DSBs and proliferation index were noted after TARE. Post-TARE CC3 activation deserves further exploration.


Asunto(s)
Neoplasias Colorrectales , Embolización Terapéutica , Estudios de Factibilidad , Neoplasias Hepáticas , Tomografía Computarizada por Tomografía de Emisión de Positrones , Radiofármacos , Radioisótopos de Itrio , Humanos , Radioisótopos de Itrio/administración & dosificación , Proyectos Piloto , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/secundario , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Masculino , Femenino , Neoplasias Colorrectales/patología , Persona de Mediana Edad , Estudios Prospectivos , Anciano , Radiofármacos/administración & dosificación , Resultado del Tratamiento , Factores de Tiempo , Biopsia Guiada por Imagen , Proliferación Celular , Antígeno Ki-67/metabolismo , Roturas del ADN de Doble Cadena , Biomarcadores de Tumor/metabolismo
10.
J Vasc Interv Radiol ; 35(6): 859-864, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38447771

RESUMEN

PURPOSE: To compare the effectiveness of percutaneous lung biopsy using a patient-mounted needle-driving robotic system with that using a manual insertion of needles under computed tomography (CT) fluoroscopy guidance. MATERIALS AND METHODS: In this institutional review board approved study, the cohort consisted of a series of patients who underwent lung biopsies following the intention-to-treat protocol from September 2022 to September 2023 using robot (n = 15) or manual insertion under single-rotation CT fluoroscopy (n = 66). Patient and procedure characteristics were recorded as well as outcomes. RESULTS: Although age, body mass index, and skin-to-target distance were not statistically different, target size varied (median, 8 mm [interquartile range, 6.5-9.5 mm] for robot vs 12 mm [8-18 mm] for single-rotation CT fluoroscopy; P = .001). No statistical differences were observed in technical success (86.7% [13/15] vs 89.4% [59/66], P = .673), Grade 3 adverse event (AE) (6.7% [1/15] vs 12.1% [8/66], P = .298), procedural time (28 minutes [22-32 minutes] vs 19 minutes [14.3-30.5 minutes], P = .086), and patient radiation dose (3.9 mSv [3.2-5.6 mSv] vs 4.6 mSv [3.3-7.5 mSv], P = .398). In robot-assisted cases, the median angle out of gantry plane was 10° (6.5°-16°), although it was null (0°-5°) for single-rotation CT fluoroscopy (P = .001). CONCLUSIONS: Robot-assisted and single-rotation CT fluoroscopy-guided percutaneous lung biopsies were similar in terms of technical success, diagnostic yield, procedural time, AEs, and radiation dose, although robot allowed for out-of-gantry plane navigation along the needle axis.


Asunto(s)
Biopsia Guiada por Imagen , Pulmón , Radiografía Intervencional , Procedimientos Quirúrgicos Robotizados , Tomografía Computarizada por Rayos X , Humanos , Masculino , Femenino , Fluoroscopía , Persona de Mediana Edad , Biopsia Guiada por Imagen/efectos adversos , Biopsia Guiada por Imagen/instrumentación , Anciano , Estudios Retrospectivos , Procedimientos Quirúrgicos Robotizados/instrumentación , Pulmón/diagnóstico por imagen , Pulmón/patología , Biopsia con Aguja/efectos adversos , Biopsia con Aguja/instrumentación , Valor Predictivo de las Pruebas , Agujas , Diseño de Equipo , Factores de Tiempo
11.
Can Assoc Radiol J ; 75(3): 658-670, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38444144

RESUMEN

Interventional Oncology (IO) stands at the forefront of transformative cancer care, leveraging advanced imaging technologies and innovative interventions. This narrative review explores recent developments within IO, highlighting its potential impact facilitated by artificial intelligence (AI), personalized medicine and imaging innovations. The integration of AI in IO holds promise for accelerating tumour detection and characterization, guiding treatment strategies and refining predictive models. Imaging modalities, including functional MRI, PET and cone beam CT are reshaping imaging and precision. Navigation, fusion imaging, augmented reality and robotics have the potential to revolutionize procedural guidance and offer unparalleled accuracy. New developments are observed in embolization and ablative therapies. The pivotal role of genomics in treatment planning, targeted therapies and biomarkers for treatment response prediction underscore the personalization of IO. Quality of life assessment, minimizing side effects and long-term survivorship care emphasize patient-centred outcomes after IO treatment. The evolving landscape of IO training programs, simulation technologies and workforce competence ensures the field's adaptability. Despite barriers to adoption, synergy between interventional radiologists' proficiency and technological advancements hold promise in cancer care.


Asunto(s)
Oncología Médica , Neoplasias , Humanos , Neoplasias/diagnóstico por imagen , Neoplasias/terapia , Oncología Médica/métodos , Inteligencia Artificial , Radiología Intervencionista/métodos , Medicina de Precisión/métodos , Radiografía Intervencional/métodos
12.
J Vasc Interv Radiol ; 35(4): 523-532.e1, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38215818

RESUMEN

PURPOSE: To evaluate the prognostic accuracy of intraprocedural and 4-8-week (current standard) post-microwave ablation zone (AZ) and margin assessments for prediction of local tumor progression (LTP) using 3-dimensional (3D) software. MATERIALS AND METHODS: Data regarding 100 colorectal liver metastases (CLMs) in 75 patients were collected from 2 prospective fluorodeoxyglucose positron emission tomography (PET)/computed tomography (CT)-guided microwave ablation (MWA) trials. The target CLMs and theoretical 5- and 10-mm margins were segmented and registered intraprocedurally and at 4-8 weeks after MWA contrast-enhanced CT (or magnetic resonance [MR] imaging) using the same methodology and 3D software. Tumor and 5- and 10-mm minimal margin (MM) volumes not covered by the AZ were defined as volumes of insufficient coverage (VICs). The intraprocedural and 4-8-week post-MWA VICs were compared as predictors of LTP using receiver operating characteristic curve analysis. RESULTS: The median follow-up time was 19.6 months (interquartile range, 7.97-36.5 months). VICs for 5- and 10-mm MMs were predictive of LTP at both time assessments. The highest accuracy for the prediction of LTP was documented with the intra-ablation 5-mm VIC (area under the curve [AUC], 0.78; 95% confidence interval, 0.66-0.89). LTP for a VIC of 6-10-mm margin category was 11.4% compared with 4.3% for >10-mm margin category (P < .001). CONCLUSIONS: A 3D 5-mm MM is a critical endpoint of thermal ablation, whereas optimal local tumor control is noted with a 10-mm MM. Higher AUCs for prediction of LTP were achieved for intraprocedural evaluation than for the 4-8-week postablation 3D evaluation of the AZ.


Asunto(s)
Ablación por Catéter , Neoplasias Hepáticas , Humanos , Resultado del Tratamiento , Estudios Prospectivos , Microondas/efectos adversos , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/cirugía , Neoplasias Hepáticas/secundario , Estudios Retrospectivos
13.
Cardiovasc Intervent Radiol ; 47(1): 80-86, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37910259

RESUMEN

PURPOSE: To evaluate factors affecting the diagnostic yield (percent of biopsy samples leading to a pathologic diagnosis) of lesional bone biopsies in patients with hematologic malignancies. MATERIALS AND METHODS: This retrospective study included 206 lesional bone biopsies in 182 patients with a hematologic malignancy between January 2017 and December 2022. The parameters that were reviewed to evaluate diagnostic yield included biopsy device type (manual vs. electric-powered drill), number of biopsy cores acquired, core biopsy needle gauge, preliminary intra-procedural sample adequacy (touch preparation cytology determining if samples are adequate for final pathologic examination), lesion morphology on Computed Tomography (CT), and presence of crush artifact. RESULTS: Review of 206 lesional biopsies showed overall diagnostic yield to be 89.8% (185/206). The two statistically significant factors affecting diagnostic yield were biopsy device type and in-room adequacy. 41/42 samples obtained with the electric-powered drill and 144/164 samples obtained using a variety of manual needles were diagnostic (97.6% vs 87.8%, p = 0.03). Of the 192 samples that were assessed for sample adequacy intra-procedurally, 97/102 of the samples that were deemed adequate were diagnostic, and 77/90 of the samples where intra-procedural adequacy was not confirmed were diagnostic (95.1% vs 85.6%, p = 0.018). The remaining factors did not affect diagnostic yield. CONCLUSION: The use of an electric-powered drill bone biopsy device and intra-procedural confirmation of sample adequacy are associated with a higher diagnostic yield of lesional bone biopsies in patients with hematologic malignancies. The presence or absence of crush artifact did not significantly affect the diagnostic yield in these patients.


Asunto(s)
Enfermedades Óseas , Neoplasias Hematológicas , Humanos , Estudios Retrospectivos , Huesos/patología , Biopsia con Aguja Fina , Biopsia Guiada por Imagen/métodos
15.
J Vasc Interv Radiol ; 35(2): 214-225.e2, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37923172

RESUMEN

PURPOSE: To assess whether yttrium-90 transarterial radioembolization (TARE) is safe and effective in the treatment of primary lung cancer metastases to the liver (LCML). METHODS AND METHODS: This retrospective study included 57 patients with LCML who were treated with 79 TARE treatments. Histology included non-small cell lung cancer (NSCLC) (n = 27), small cell lung cancer (SCLC) (n = 17), and lung carcinoid (LC) (n = 13). Survival was calculated using Kaplan-Meier method; differences between groups were estimated using log rank test. Cox proportional hazards model was used to determine factors influencing survival. Adverse events were graded using the Society of Interventional Radiology Adverse Events Classification. RESULTS: Median overall survival (OS) was as follows: NSCLC, 8.3 months (95% confidence interval [CI], 6.3-16.4 months); SCLC, 4.1 months (95% CI, 1.9-6.6 months); and LC, 43.5 months (95% CI, 7.8-61.4 months). For NSCLC, presence of bilobar vs unilobar disease (hazard ratio [HR], 5.24; 95% CI, 1.64-16.79; P = .002); more tumors, 2-5 vs 1 (HR, 4.88; 95% CI, 1.17-20.37; P = .003) and >5 vs 1 (HR, 3.75; 95% CI, 0.95-6.92; P = .05); and lobar vs segmental treatment (HR, 2.56; 95% CI, 0-NA; P = .002) were negative predictors of OS. For SCLC, receipt of >2 lines of chemotherapy vs ≤2 lines (HR, 3.16; 95% CI, 0.95-10.47; P = .05) was a negative predictor of OS. For LC, tumor involvement of >50% was a negative predictor of OS (HR, 3.77 × 1015; 95% CI, 0-NA; P = .002). There were 11 of 79 severe or life-threatening adverse events within 30 days (abdominal pain, altered mental status, nausea/vomiting, acalculous/aseptic cholecystitis, hyponatremia, pancreatitis, renal failure, and death from pneumonia). CONCLUSIONS: TARE has an acceptable safety profile for the treatment of LCML, with survival benefits best seen in LC tumors.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Hepáticas , Neoplasias Pulmonares , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/radioterapia , Resultado del Tratamiento , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/radioterapia , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Estudios Retrospectivos , Radioisótopos de Itrio/efectos adversos
16.
J Med Imaging Radiat Oncol ; 67(8): 832-841, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37944085

RESUMEN

The presence of hepatic metastases indicates advanced disease and is associated with significant morbidity and mortality, especially when the hepatic disease is not amenable to locoregional treatments. The primary tumour of origin, the distribution and extent of metastatic disease, the underlying liver reserve, the patient performance status and the presence of comorbidities are factors that determine whether a patient will benefit from hepatectomy or local curative-intent treatments. For patients with metastatic colorectal cancer, the most common primary cancer that spreads to the liver, several studies have demonstrated a survival benefit for patients who can be treated with hepatectomy and/or percutaneous ablation, compared to those treated with chemotherapy alone. Despite advances in surgical techniques increasing the percentage of patients eligible for surgery, most patients have unresectable disease or are poor surgical candidates. Percutaneous ablation can be used to provide local disease control and prolong survival for both surgical and non-surgical candidates. This is typically offered to patients with small hepatic metastases that can be ablated with optimal (≥10 mm) or at least adequate minimum ablation margins (≥5 mm), as high local tumour control rates can be achieved for these patients which are comparable to surgical resection. This review summarizes available evidence and outcomes following percutaneous ablation of the most frequently encountered types of hepatic metastases in the clinical practice of interventional oncology. Patient selection, technical considerations, follow-up protocols and oncologic outcomes are presented and discussed.


Asunto(s)
Ablación por Catéter , Neoplasias Colorrectales , Neoplasias Hepáticas , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/cirugía , Neoplasias Hepáticas/secundario , Ablación por Catéter/métodos , Neoplasias Colorrectales/patología , Hepatectomía/métodos , Resultado del Tratamiento
17.
J Vasc Interv Radiol ; 34(12): 2174-2179, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37673400

RESUMEN

This retrospective study evaluated the feasibility and safety of percutaneous computed tomography (CT)-guided bone biopsies in patients with cancer using a patient-mounted robotic system with steering capabilities. The study included 39 patients (17 women, 22 men; median age, 65.5 years; interquartile range [IQR], 54.8-71.0 years). Forty biopsies were performed in the pelvis, spine, ribs, shoulder, femur, and sternum. The technical success rate was 100%, and the median trajectory length was 55.9 mm (IQR, 47.1-73.6 mm). Intermediate checkpoints were used in 8 biopsies. Median time from the first to final scan was 21 minutes (IQR, 17-37 minutes). The overall procedure time was 30 minutes (IQR, 24-36 minutes). The median dose length product and effective dose were 536.6 mGy⋅cm (IQR, 396.2-837.7 mGy∗cm) and 7.1 mSv (IQR, 4.7-10.8 mSv), respectively. No adverse events occurred. The diagnostic yield for cancer was 72.5%. Percutaneous robotic-assisted bone biopsies demonstrated high technical success, adequate diagnostic yield, and favorable safety profile.


Asunto(s)
Neoplasias , Procedimientos Quirúrgicos Robotizados , Masculino , Humanos , Femenino , Anciano , Estudios Retrospectivos , Estudios de Factibilidad , Procedimientos Quirúrgicos Robotizados/efectos adversos , Biopsia Guiada por Imagen/efectos adversos , Biopsia Guiada por Imagen/métodos , Tomografía Computarizada por Rayos X/métodos , Neoplasias/diagnóstico por imagen
18.
Lung Cancer ; 178: 157-165, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36868176

RESUMEN

OBJECTIVES: Lung cancer models in large animals are lacking. Oncopigs are transgenic pigs that carry both KRASG12D and TP53R167H Cre-inducible mutations. This study aimed to develop and histologically characterize a swine model of lung cancer that could serve for preclinical studies evaluating locoregional therapies. MATERIALS AND METHODS: In two Oncopigs, an adenoviral vector encoding the Cre-recombinase gene (AdCre) was injected endovascularly through the pulmonary arteries or inferior vena cava. In two other Oncopigs, a lung biopsy was performed and incubated with AdCre, before reinjecting the mixture into the lungs percutaneously. Animals were clinically and biologically (complete blood count, liver enzymes and lipasemia) monitored. Obtained tumors were characterized on computed tomography (CT) and on pathology and immunohistochemistry (IHC). RESULTS: Neoplastic lung nodules developed following 1 (1/10, 10%) endovascular inoculation, and 2 (2/6, 33%) percutaneous inoculations. All lung tumors were visible at the 1-week CT, and appeared as well-circumscribed solid nodules, with a median longest diameter of 14 mm (range: 5-27 mm). Only one complication occurred: an extravasation of the mixture into the thoracic wall during a percutaneous injection that resulted in a thoracic wall tumor. Pigs remained clinically healthy during the entire follow-up (14-21 days). On histology, tumors consisted of inflammatory undifferentiated neoplasms composed of atypical spindle and epithelioid cells and/or a fibrovascular stroma and abundant mixed leukocytic infiltrate. On IHC, atypical cells diffusely displayed expression of vimentin and some showed expression of CK WSS and CK 8/18. The tumor microenvironment contained abundant IBA1 + macrophages and giant cells, CD3 + T cells, and CD31 + blood vessels. CONCLUSION: Tumors induced in the lungs of Oncopigs are fast growing poorly differentiated neoplasms associated with a marked inflammatory reaction that can be easily and safely induced at site specific locations. This large animal model might be suitable for interventional and surgical therapies of lung cancer.


Asunto(s)
Neoplasias Pulmonares , Nódulos Pulmonares Múltiples , Animales , Humanos , Porcinos , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/terapia , Neoplasias Pulmonares/patología , Modelos Animales de Enfermedad , Pulmón/patología , Mutación , Microambiente Tumoral
19.
Cancers (Basel) ; 14(24)2022 Dec 19.
Artículo en Inglés | MEDLINE | ID: mdl-36551738

RESUMEN

BACKGROUND: Real-time split-dose PET can identify the targeted colorectal liver metastasis (CLM) and eliminate the need for repeated contrast administration before and during thermal ablation (TA). This study aimed to assess the added value of pre-ablation real-time split-dose PET when combined with non-contract CT in the detection of CLM for ablation and the evaluation of the ablation zone and margins. METHODS: A total of 190 CLMs/125 participants from two IRB-approved prospective clinical trials using PET/CT-guided TA were analyzed. Based on detection on pre-TA imaging, CLMs were categorized as detectable, non-detectable, and of poor conspicuity on CT alone, and detectable, non-detectable, and low FDG-avidity on PET/CT after the initial dose. Ablation margins around the targeted CLM were evaluated using a 3D volumetric approach. RESULTS: We found that 129/190 (67.9%) CLMs were detectable on CT alone, and 61/190 CLMs (32.1%) were undetectable or of poor conspicuity, not allowing accurate depiction and targeting by CT alone. Thus, the theoretical 5- and 10-mm margins could not be defined in these tumors (32.1%) using CT alone. When TA intraprocedural PET/CT images are obtained and inspected (fused PET/CT), only 4 CLM (2.1%) remained undetectable or had a low FDG avidity. CONCLUSIONS: The addition of PET to non-contrast CT improved CLM detection for ablation targeting, margin assessments, and continuous depiction of the FDG avid CLMs during the ablation without the need for multiple intravenous contrast injections pre- and intra-procedurally.

20.
J Vasc Interv Radiol ; 33(11): 1408-1415.e3, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35940363

RESUMEN

PURPOSE: To evaluate a transmission optical spectroscopy instrument for rapid ex vivo assessment of core needle cancer biopsies (CNBs) at the point of care. MATERIALS AND METHODS: CNBs from surgically resected renal tumors and nontumor regions were scanned on their sampling trays with a custom spectroscopy instrument. After extracting principal spectral components, machine learning was used to train logistic regression, support vector machines, and random decision forest (RF) classifiers on 80% of randomized and stratified data. The algorithms were evaluated on the remaining 20% of the data set held out during training. Binary classification (tumor/nontumor) was performed based on a decision threshold. Multinomial classification was also performed to differentiate between the subtypes of renal cell carcinoma (RCC) and account for potential confounding effects from fat, blood, and necrotic tissue. Classifiers were compared based on sensitivity, specificity, and positive predictive value (PPV) relative to a histopathologic standard. RESULTS: A total of 545 CNBs from 102 patients were analyzed, yielding 5,583 spectra after outlier exclusion. At the individual spectra level, the best performing algorithm was RF with sensitivities of 96% and 92% and specificities of 90% and 89%, for the binary and multiclass analyses, respectively. At the full CNB level, RF algorithm also showed the highest sensitivity and specificity (93% and 91%, respectively). For RCC subtypes, the highest sensitivity and PPV were attained for clear cell (93.5%) and chromophobe (98.2%) subtypes, respectively. CONCLUSIONS: Ex vivo spectroscopy imaging paired with machine learning can accurately characterize renal mass CNB at the time of tissue acquisition.


Asunto(s)
Carcinoma de Células Renales , Neoplasias Renales , Humanos , Biopsia con Aguja Gruesa/métodos , Sistemas de Atención de Punto , Carcinoma de Células Renales/diagnóstico por imagen , Carcinoma de Células Renales/cirugía , Carcinoma de Células Renales/patología , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/patología , Análisis Espectral
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA