Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Am J Cardiol ; 82(5): 676-9, A8, 1998 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-9732902

RESUMEN

In a group of 20 patients implanted with a single-lead VDD pacing system, a wide interindividual variability was found in P-wave amplitude changes occurring under dynamic conditions, even though they were of minor clinical relevance because constant atrial tracking was maintained.


Asunto(s)
Electrocardiografía/instrumentación , Bloqueo Cardíaco/terapia , Marcapaso Artificial , Anciano , Anciano de 80 o más Años , Diseño de Equipo , Prueba de Esfuerzo , Femenino , Estudios de Seguimiento , Bloqueo Cardíaco/fisiopatología , Humanos , Masculino , Postura/fisiología , Respiración/fisiología
2.
Minerva Med ; 71(30): 2141-3, 1980 Aug 25.
Artículo en Italiano | MEDLINE | ID: mdl-7432647

RESUMEN

The Authors report their experience related to clinical follow-up (F.U.) study of a 12 patients group who showed a prolonged sinus node recovery time (SNRT) as the only pathologic datum. F.U. study appears extremely useful for clinical arrangement of these patients. In 6 patients a gastric ulcer was associated, which is considered a morbid equivalent of vagotonia. Therefore SNRT could be a false positive. In 3 patients following controls allow to document an initial ischemic cardiopathy. Tachicardic phase of S.S.S. was documented in 3 patients.


Asunto(s)
Bradicardia/etiología , Enfermedad Coronaria/complicaciones , Estudios de Seguimiento , Humanos , Síndrome del Seno Enfermo/complicaciones , Nodo Sinoatrial/fisiopatología , Úlcera Gástrica/complicaciones , Nervio Vago/fisiopatología
3.
G Ital Cardiol ; 10(5): 565-77, 1980.
Artículo en Italiano | MEDLINE | ID: mdl-7450378

RESUMEN

78 patients who underwent disc prostheses replacement, 36 in mitral area, 58 in aortic area were studied by echocardiography. The Authors found 5 cases of malfunction, 3 in mitral area and 2 in aortic area. Regarding mitral malfunctions in 1 case a valve thrombosis was found; in 2 cases there was a partial leak. Regarding aortic malfunctions there was paravalvular leak. In mitral area malfunctions the Authors found alterations of the disc morphology during diastolic opening time associated with alteration of opening time. An increased diastolic closure velocity in 2 cases of paraprosthetic leak was found. A diagnostic element in the case with thrombosis was variability of maximal disc escursion during the same recording, because opening time variability never got over 10 m. seconds. In aortic area malfunctions the Authors found a constant fluttering of anterior mitral leaflet, a sinergic septal motion with the posterior wall and in 1 case the presence of disc opening before the first component of the first sound. The Authors underline the importance of simultaneous eco-phonocardiographic examination and the check-ups for the time to be.


Asunto(s)
Válvula Aórtica/fisiopatología , Ecocardiografía , Prótesis Valvulares Cardíacas/efectos adversos , Válvula Mitral/fisiopatología , Adulto , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico , Enfermedades de las Válvulas Cardíacas/cirugía , Humanos , Masculino , Persona de Mediana Edad , Trombosis/diagnóstico
5.
Minerva Med ; 67(63): 4235-9, 1976 Dec 29.
Artículo en Italiano | MEDLINE | ID: mdl-1018817

RESUMEN

An unusual instance of transient prosthesis breakdown in a 29-yr-old woman with two L-Kaster disk prostheses for mitro-aortic defect is reported. The ECHO and polygraphic traces observed during and after breakdown are examined. It is considered that the breakdown which occurred in one prostheis only, was attributable to a small, internal thrombosis with embolism of the right lower extremity.


Asunto(s)
Prótesis Valvulares Cardíacas , Válvula Mitral/cirugía , Trombosis/complicaciones , Adulto , Ecocardiografía , Electrocardiografía , Femenino , Humanos , Fonocardiografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA