Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Molecules ; 29(13)2024 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-38999172

RESUMEN

This article presents cyclic voltammetry, Tafel polarization, and ac. impedance spectroscopy examinations of resorcinol (RC) ion reactivity on Pt(511) single-crystal plane and the effect of surface-electrosorbed RC ions on the kinetics of UPD H (underpotentially deposited hydrogen) and HER (hydrogen evolution reaction) processes in 0.1 M NaOH solution. Obtained data delivered a proof for the RC ion surface adsorption and its later electroreduction over the potential range characteristic for the UPD H. A favourable role of platinum-adsorbed resorcinol anions on the kinetics of the UPD H and HER processes is also discussed. The above was explained via the recorded capacitance and charge-transfer resistance parameters (the presence of resorcinol at 1.5 × 10-3 M in 0.1 M NaOH caused significant reduction in the resistance parameter values by 3.9 and 2.6 times, correspondingly, for the UPD of H at 50 mV and the HER process, examined at -50 mV vs. RHE) along with the charge transients, produced by injecting small amounts of RC-based 0.1 M NaOH solution to initially RC-free base electrolyte on the Pt(511) electrode plane (a large cathodic charge-transient density of -90 µC cm-2 was recorded at the electrode potential of 50 mV).

2.
Molecules ; 26(15)2021 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-34361734

RESUMEN

Traditional wastewater purification processes are based on a combination of physical, chemical, and biological methods; however, typical electrochemical techniques for removing pollutants require large amounts of electrical energy. In this study, we report on a process of wastewater purification, through continuous anodic dissolution of iron anode for aerated Cu/Fe galvanic cell in synthetic Na2SO4 wastewater solution. Electrochemical experiments were conducted by means of a laboratory size electrolyzer, where electrocoagulation along with electrooxidation phenomena were examined for wastewater containing Acid Mixture dye. The above was visualized through the employment of electrochemical (cyclic voltammetry and ac impedance spectroscopy techniques) along with instrumental spectroscopy analyses.

3.
Molecules ; 25(18)2020 Sep 08.
Artículo en Inglés | MEDLINE | ID: mdl-32911834

RESUMEN

This paper reports on the process of industrial-type wastewater purification carried-out through continuous anodic dissolution of aluminum alloy sacrificial anode for artificially aerated Cu-Al alloy galvanic (macro-corrosion) cells and synthetically prepared wastewater solutions. Electrochemical experiments were performed by means of a laboratory size electrolyzer unit, where the electrocoagulation process along with surface-induced electrooxidation phenomena were examined for wastewater containing Acid Mixture and Disperse Red 167 dyes. Final reduction of the dyes concentrations came to 32 and 99% for Acid Mixture and Disperse Red 167, correspondingly. The above was visualized through the employment of electrochemical (cyclic voltammetry and a.c. impedance spectroscopy techniques) and instrumental spectroscopy analyses.


Asunto(s)
Aluminio/química , Colorantes/química , Cobre/química , Electroquímica/métodos , Electrodos , Aguas Residuales/química , Purificación del Agua/métodos , Corrosión , Espectroscopía Dieléctrica , Electrocoagulación/métodos , Electrólisis , Oxidación-Reducción , Solubilidad
4.
Molecules ; 24(12)2019 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-31234459

RESUMEN

Electrochemical oxidation of resorcinol on a polycrystalline platinum electrode was investigated in five different solutions, namely 0.5 and 0.1 M H2SO4, 0.5 M Na2SO4, 0.5 and 0.1 M NaOH. The rates of electrochemical degradation of resorcinol were determined based on the obtained reaction parameters, such as resistance, capacitance and current-density. The electrochemical analyses (cyclic voltammetry and a.c. impedance spectroscopy) were carried-out by means of a three-compartment, Pyrex glass cell. These results showed that the electrochemical oxidation of resorcinol is strongly pH-dependent. In addition, the energy dispersive X-ray (EDX) spectroscopy technique was employed for Pt electrode surface characterization. Additionally, the quantitative determination of resorcinol removal was performed by means of instrumental high-performance liquid chromatography/mass spectrometry (HPLC/MS) methodology.


Asunto(s)
Platino (Metal)/química , Resorcinoles/química , Soluciones/química , Espectroscopía Dieléctrica , Técnicas Electroquímicas , Electroquímica , Concentración de Iones de Hidrógeno , Cinética , Oxidación-Reducción , Espectrometría por Rayos X
5.
Molecules ; 23(6)2018 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-29843441

RESUMEN

This work reports on the kinetics of electrochemical degradation of the resorcinol molecule, examined on nickel foam-based electrodes in contact with 0.1 M NaOH and 0.5 M Na2SO4 supporting electrolytes. The electrooxidation of resorcinol was examined on as-received, as well as on Pd-modified, nickel foam catalyst materials, produced via spontaneous deposition of trace amounts of palladium element. Electrochemical (cyclic voltammetry and a.c. impedance) experiments were carried out by means of a three-compartment, pyrex glass electrochemical cell, whereas continuous resorcinol electrooxidation tests were conducted galvanostatically (or potentistatically) with a laboratory-size, single-cell electrolyzer unit. In addition, quantitative determination of resorcinol and its possible electrodegradation products was performed by means of instrumental HPLC: High-Performance Liquid Chromatography/MS: Mass Spectrometry methodology. Also, SEM (Scanning Electron Microscopy) and EDX (Energy Dispersive X-ray spectroscopy) techniques were employed for Ni foam (Pd-modified Ni foam) surface characterizations.


Asunto(s)
Níquel/química , Resorcinoles/química , Hidróxido de Sodio/química , Sulfatos/química , Catálisis , Electroquímica , Electrodos , Concentración de Iones de Hidrógeno , Microscopía Electrónica de Rastreo , Estructura Molecular , Espectrometría por Rayos X
6.
Arch Med Sci ; 11(5): 1058-64, 2015 Oct 12.
Artículo en Inglés | MEDLINE | ID: mdl-26528351

RESUMEN

INTRODUCTION: The prevalence of lateral curvatures of the spine ranges from 0.3% to 15.3% in the general population. The aim of the study was to develop and compare three different screening tests for idiopathic scoliosis (IS) with respect to their effectiveness and costs. MATERIAL AND METHODS: The Delphi method was used to assess the efficacy of each screening algorithm in detecting IS in the population. An economic analysis was also performed. RESULTS: Diagnostic Algorithm 1 for IS comprised a screening examination performed by nurses and a general practitioner (GP) with verification by specialists. The unit cost of carrying out diagnostic work-up for IS in Algorithm 1 was €94 per child. The second algorithm involved the use of the moiré computer method, followed by verification by a specialist. The lower unit cost of €86 per child of diagnostic work-up according to Algorithm 2 was due to fewer stages compared to Algorithm 1. The highest effectiveness with the highest costs were found for the third algorithm, with only one stage, a specialist's consultation (cost €153 per child). CONCLUSIONS: The number of stages in an algorithm does not correlate positively with its efficacy or cost. The recommended scheme is Algorithm 3, where children are examined by rehabilitation specialists or a physiotherapist using a scoliometer and an inclinometer. The use of the apparently most expensive scheme (Algorithm 3) should result in lowering the costs of treatment of established idiopathic scoliosis and, in the long term, prove to be the most cost-effective solution for the health care system.

7.
BMC Pediatr ; 14: 221, 2014 Sep 04.
Artículo en Inglés | MEDLINE | ID: mdl-25189936

RESUMEN

BACKGROUND: Screening tests play a significant role in rapid and reliable assessment of normal individual development in the entire population of children and adolescents. Body posture screening tests carried out at schools reveal that 50-60% of children and adolescents demonstrate body posture abnormalities, with 10% of this group at risk for progressive spinal deformities. This necessitates the search for effective and economically feasible forms of screening diagnosis. The aim of this study was to assess the reliability of clinical evaluation of body posture compared to objective assessment with the Zebris CMS-10 system (Zebris Medical GmbH). METHODS: The study enrolled 13-15-year-old pupils attending a junior secondary school (mean age 14.2 years). The study group consisted of 138 participants, including 71 girls and 67 boys, who underwent a clinical evaluation of the body posture and an examination with the Zebris CMS 10 system. RESULTS: Statistically significant discrepancies between the clinical and objective evaluation were noted with regard to lumbar lordosis in boys (n = 67) and thoracic kyphosis in girls (n = 71). No statistically significant differences in both groups were noted for pelvic rotation and trunk position in the frontal plane. CONCLUSIONS: 1. The finding of significant discrepancies between the results of assessment in the sagittal plane obtained in the clinical examination and Zebris CMS-10-based assessment suggests that clinical evaluation should be used to provide a general estimation of accentuation or reduction of spinal curvatures in the sagittal plane.2. The clinical evaluation of posture is reliable with regard to assessment in the frontal plane.3. The Zebris CMS-10 system makes the clinical examination significantly more objective with regard to assessment of the physiological curvatures and may be used to make screening tests more objective with regard to detecting postural defects.


Asunto(s)
Examen Físico/métodos , Postura , Curvaturas de la Columna Vertebral/diagnóstico , Adolescente , Femenino , Humanos , Masculino , Examen Físico/instrumentación , Reproducibilidad de los Resultados
8.
J Solid State Electrochem ; 17(3): 889-893, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23450192

RESUMEN

The present paper reports an alternate current impedance spectroscopic study on adsorption of urea (U) at Pt(100) single-crystal surface, examined in 0.5 M H2SO4 supporting electrolyte. The resulted information provided confirmation of the role of electrosorption of urea on the Pt(100) plane through evaluation of the associated charge transfer resistance and capacitance parameters. Obtained impedance results were compared to those previously recorded for guanidinium cation (G+) under analogous experimental conditions, especially with respect to the so-called ion pairing mechanism, as originally proposed for the G+ ion and bi(sulfate)/OH species, based on the voltammetric and in situ Fourier transform infrared spectroscopy results.

9.
Water Sci Technol ; 67(2): 404-9, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23168642

RESUMEN

This study compares the effectiveness of pollutant removal from synthetic dairy wastewater electrocoagulated by means of aluminum and iron anodic dissolution. A method based on the cubic function (third degree polynomial) was proposed for electrocoagulant dosing. Mathematical methods for calculating the optimal electrocoagulant doses proved to be quite precise and useful for practical applications. The results of gravimetric measurements of electrocoagulant (electrode) consumption demonstrated that theoretical doses of Al determined based on Faraday's law were substantially lower than those produced by electrode weighing. The above phenomenon was also discussed in the light of the results of polarization resistance measurements for Al and Fe electrodes used in the study.


Asunto(s)
Industria Lechera , Electroquímica/métodos , Aguas Residuales/química , Purificación del Agua/métodos , Aluminio/química , Impedancia Eléctrica , Electroquímica/instrumentación , Electrodos , Hierro/química , Contaminantes Químicos del Agua/aislamiento & purificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA