Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 356
Filtrar
1.
ArXiv ; 2024 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-39371085

RESUMEN

Prostate cancer is one of the most prevalent malignancies in the world. While deep learning has potential to further improve computer-aided prostate cancer detection on MRI, its efficacy hinges on the exhaustive curation of manually annotated images. We propose a novel methodology of semisupervised learning (SSL) guided by automatically extracted clinical information, specifically the lesion locations in radiology reports, allowing for use of unannotated images to reduce the annotation burden. By leveraging lesion locations, we refined pseudo labels, which were then used to train our location-based SSL model. We show that our SSL method can improve prostate lesion detection by utilizing unannotated images, with more substantial impacts being observed when larger proportions of unannotated images are used.

2.
J Pers Med ; 14(10)2024 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-39452554

RESUMEN

BACKGROUND/OBJECTIVES: Apparent Diffusion Coefficient (ADC) maps in prostate MRI can reveal tumor characteristics, but their accuracy can be compromised by artifacts related with patient motion or rectal gas associated distortions. To address these challenges, we propose a novel approach that utilizes a Generative Adversarial Network to synthesize ADC maps from T2-weighted magnetic resonance images (T2W MRI). METHODS: By leveraging contrastive learning, our model accurately maps axial T2W MRI to ADC maps within the cropped region of the prostate organ boundary, capturing subtle variations and intricate structural details by learning similar and dissimilar pairs from two imaging modalities. We trained our model on a comprehensive dataset of unpaired T2-weighted images and ADC maps from 506 patients. In evaluating our model, named AI-ADC, we compared it against three state-of-the-art methods: CycleGAN, CUT, and StyTr2. RESULTS: Our model demonstrated a higher mean Structural Similarity Index (SSIM) of 0.863 on a test dataset of 3240 2D MRI slices from 195 patients, compared to values of 0.855, 0.797, and 0.824 for CycleGAN, CUT, and StyTr2, respectively. Similarly, our model achieved a significantly lower Fréchet Inception Distance (FID) value of 31.992, compared to values of 43.458, 179.983, and 58.784 for the other three models, indicating its superior performance in generating ADC maps. Furthermore, we evaluated our model on 147 patients from the publicly available ProstateX dataset, where it demonstrated a higher SSIM of 0.647 and a lower FID of 113.876 compared to the other three models. CONCLUSIONS: These results highlight the efficacy of our proposed model in generating ADC maps from T2W MRI, showcasing its potential for enhancing clinical diagnostics and radiological workflows.

3.
Radiol Imaging Cancer ; 6(6): e240050, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-39400232

RESUMEN

Purpose To evaluate the performance of an artificial intelligence (AI) model in detecting overall and clinically significant prostate cancer (csPCa)-positive lesions on paired external and in-house biparametric MRI (bpMRI) scans and assess performance differences between each dataset. Materials and Methods This single-center retrospective study included patients who underwent prostate MRI at an external institution and were rescanned at the authors' institution between May 2015 and May 2022. A genitourinary radiologist performed prospective readouts on in-house MRI scans following the Prostate Imaging Reporting and Data System (PI-RADS) version 2.0 or 2.1 and retrospective image quality assessments for all scans. A subgroup of patients underwent an MRI/US fusion-guided biopsy. A bpMRI-based lesion detection AI model previously developed using a completely separate dataset was tested on both MRI datasets. Detection rates were compared between external and in-house datasets with use of the paired comparison permutation tests. Factors associated with AI detection performance were assessed using multivariable generalized mixed-effects models, incorporating features selected through forward stepwise regression based on the Akaike information criterion. Results The study included 201 male patients (median age, 66 years [IQR, 62-70 years]; prostate-specific antigen density, 0.14 ng/mL2 [IQR, 0.10-0.22 ng/mL2]) with a median interval between external and in-house MRI scans of 182 days (IQR, 97-383 days). For intraprostatic lesions, AI detected 39.7% (149 of 375) on external and 56.0% (210 of 375) on in-house MRI scans (P < .001). For csPCa-positive lesions, AI detected 61% (54 of 89) on external and 79% (70 of 89) on in-house MRI scans (P < .001). On external MRI scans, better overall lesion detection was associated with a higher PI-RADS score (odds ratio [OR] = 1.57; P = .005), larger lesion diameter (OR = 3.96; P < .001), better diffusion-weighted MRI quality (OR = 1.53; P = .02), and fewer lesions at MRI (OR = 0.78; P = .045). Better csPCa detection was associated with a shorter MRI interval between external and in-house scans (OR = 0.58; P = .03) and larger lesion size (OR = 10.19; P < .001). Conclusion The AI model exhibited modest performance in identifying both overall and csPCa-positive lesions on external bpMRI scans. Keywords: MR Imaging, Urinary, Prostate Supplemental material is available for this article. © RSNA, 2024.


Asunto(s)
Aprendizaje Profundo , Imagen por Resonancia Magnética , Neoplasias de la Próstata , Humanos , Masculino , Neoplasias de la Próstata/diagnóstico por imagen , Estudios Retrospectivos , Anciano , Imagen por Resonancia Magnética/métodos , Persona de Mediana Edad , Algoritmos , Próstata/diagnóstico por imagen , Próstata/patología , Interpretación de Imagen Asistida por Computador/métodos , Biopsia Guiada por Imagen/métodos
4.
Artículo en Inglés | MEDLINE | ID: mdl-39390262

RESUMEN

PURPOSE: Surgery, an established short-term immunosuppressive event, may spur dissemination of circulating tumor cells and promote the growth of micrometastases. Whether surgical treatment for prostate cancer (i.e., radical prostatectomy) leads to long-term immune changes is unknown. METHODS: We characterized intra-individual changes in circulating immune cell subsets across a six-month period using serial blood samples from prostate cancer patients pre- and post-radical prostatectomy (n = 11), and from a comparison group managed with active surveillance (n = 8). Immune cell subsets for each patient at each time point were deconvoluted using genome-wide methylation data. RESULTS: There were no statistically significant intra-individual changes in immune cell proportions from pre- to six months post-radical prostatectomy. There were also no intra-individual changes in immune cell proportions in the active surveillance group, and no differences between treatment groups in immune cell changes over time. CONCLUSION: We observed no meaningful changes in circulating immune cell subsets six months after radical prostatectomy, suggesting that surgery-induced immune changes may not be long-lasting.

5.
Acad Radiol ; 2024 Oct 18.
Artículo en Inglés | MEDLINE | ID: mdl-39426916

RESUMEN

RATIONALE AND OBJECTIVES: The increasing use of focal therapy (FT) in localized prostate cancer (PCa) management requires a standardized MRI interpretation system to detect recurrent clinically significant PCa (csPCa). This pilot study evaluates the novel Transatlantic Recommendations for Prostate Gland Evaluation with MRI after Focal Therapy (TARGET) and compares its performance to that of the Prostate Imaging after Focal Ablation (PI-FAB) system. MATERIALS AND METHODS: This retrospective study included 38 patients who underwent primary FT for localized PCa, with follow-up multiparametric MRI (mpMRI) and biopsy. Two radiologists assessed the mpMRIs using both PI-FAB and TARGET independently. Diagnostic performance metrics and area under the receiver operating characteristic curve (AUC) were calculated. Inter-reader and intrareader agreement were assessed using Cohen's κ and Kendall's τ. RESULTS: 14 patients had recurrent csPCa. PI-FAB showed high sensitivity (92.9% for both readers) and NPV (reader 1: 93.8%, reader 2: 92.9%) but moderate specificity (reader 1: 62.5%, reader 2: 54.2%). TARGET demonstrated lower sensitivity for one reader (reader 1: 78.6%, reader 2: 92.9%) but higher specificity (reader 1: 79.2%, reader 2: 62.5%) for both readers. Both systems displayed moderate inter-reader agreement (κ = 0.56 for PI-FAB, 0.57 for TARGET). CONCLUSION: PI-FAB and TARGET exhibit similar performances in post-FT MRI. While PI-FAB had consistently high sensitivity, TARGET offered higher specificity for one reader. Moderate agreement levels demonstrate the viability of these systems in clinical settings and a promise for improvement.

6.
Urology ; 2024 Oct 18.
Artículo en Inglés | MEDLINE | ID: mdl-39427924

RESUMEN

OBJECTIVES: To evaluate MRI-based measurements of androgen-sensitive perineal/pelvic muscles in men with prostate cancer before and after androgen deprivation therapy (ADT) as a novel imaging marker for end-organ effects of hypogonadism. Diagnosing hypogonadism or testosterone deficiency (TD) requires both low serum testosterone and clinical symptoms, such as erectile dysfunction and reduced libido. However, the non-specific nature of many TD symptoms makes it challenging to initiate therapy. Objective markers of TD help to better identify patients who may benefit from testosterone supplementation; however, current markers, such as low bone mineral density, lack sensitivity. Previous studies suggest that decreased bulbocavernosus-muscle (BCM) thickness may be associated with TD, although it remains unclear if this is a correlative relationship. METHODS: Data was prospectively collected for patients with intermediate/high-risk localized prostate cancer enrolled in a phase II trial (NCT02430480). Patients received ADT before prostatectomy and underwent prostate MRI pre-/post-ADT. BCM, ischiocavernosus-muscle (ICM), and levator-ani-muscle (LAM) measurements were made using T2W-MRI. Paired t-tests evaluated changes in BCM/ICM/LAM width, and linear regression analyses evaluated relationships between changes in testosterone and muscle width. RESULTS: Thirty-eight consecutive patients with pre-/post-ADT MRIs were analyzed. Baseline testosterone was 286.5ng/dl, and 36/38 patients had post-ADT testosterone <50ng/dL. Pre-ADT and post-ADT measurements of the bilateral BCM/ICM/LAM width were 7.16mm/7.95mm/5.53mm and 5.68mm/6.71mm/4.89mm, respectively (p<0.001). Decreases in testosterone predicted reduction in combined perineal muscle (BCM+ICM) width (p=0.032). CONCLUSIONS: Androgen deprivation led to significant and relatively rapid decreases in BCM/ICM/LAM thickness. This objective biomarker of low testosterone states may help identify patients who will potentially benefit from testosterone replacement.

7.
Artículo en Inglés | MEDLINE | ID: mdl-39178097

RESUMEN

Multi-parametric magnetic resonance imaging (mpMRI) exams have various series types acquired with different imaging protocols. The DICOM headers of these series often have incorrect information due to the sheer diversity of protocols and occasional technologist errors. To address this, we present a deep learning-based classification model to classify 8 different body mpMRI series types so that radiologists read the exams efficiently. Using mpMRI data from various institutions, multiple deep learning-based classifiers of ResNet, EfficientNet, and DenseNet are trained to classify 8 different MRI series, and their performance is compared. Then, the best-performing classifier is identified, and its classification capability under the setting of different training data quantities is studied. Also, the model is evaluated on the out-of-training-distribution datasets. Moreover, the model is trained using mpMRI exams obtained from different scanners in two training strategies, and its performance is tested. Experimental results show that the DenseNet-121 model achieves the highest F1-score and accuracy of 0.966 and 0.972 over the other classification models with p-value 0.05. The model shows greater than 0.95 accuracy when trained with over 729 studies of the training data, whose performance improves as the training data quantities grew larger. On the external data with the DLDS and CPTAC-UCEC datasets, the model yields 0.872 and 0.810 accuracy for each. These results indicate that in both the internal and external datasets, the DenseNet-121 model attains high accuracy for the task of classifying 8 body MRI series types.

8.
J Pathol Inform ; 15: 100381, 2024 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38953042

RESUMEN

The Gleason score is an important predictor of prognosis in prostate cancer. However, its subjective nature can result in over- or under-grading. Our objective was to train an artificial intelligence (AI)-based algorithm to grade prostate cancer in specimens from patients who underwent radical prostatectomy (RP) and to assess the correlation of AI-estimated proportions of different Gleason patterns with biochemical recurrence-free survival (RFS), metastasis-free survival (MFS), and overall survival (OS). Training and validation of algorithms for cancer detection and grading were completed with three large datasets containing a total of 580 whole-mount prostate slides from 191 RP patients at two centers and 6218 annotated needle biopsy slides from the publicly available Prostate Cancer Grading Assessment dataset. A cancer detection model was trained using MobileNetV3 on 0.5 mm × 0.5 mm cancer areas (tiles) captured at 10× magnification. For cancer grading, a Gleason pattern detector was trained on tiles using a ResNet50 convolutional neural network and a selective CutMix training strategy involving a mixture of real and artificial examples. This strategy resulted in improved model generalizability in the test set compared with three different control experiments when evaluated on both needle biopsy slides and whole-mount prostate slides from different centers. In an additional test cohort of RP patients who were clinically followed over 30 years, quantitative Gleason pattern AI estimates achieved concordance indexes of 0.69, 0.72, and 0.64 for predicting RFS, MFS, and OS times, outperforming the control experiments and International Society of Urological Pathology system (ISUP) grading by pathologists. Finally, unsupervised clustering of test RP patient specimens into low-, medium-, and high-risk groups based on AI-estimated proportions of each Gleason pattern resulted in significantly improved RFS and MFS stratification compared with ISUP grading. In summary, deep learning-based quantitative Gleason scoring using a selective CutMix training strategy may improve prognostication after prostate cancer surgery.

9.
Abdom Radiol (NY) ; 49(8): 2891-2901, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38958754

RESUMEN

OBJECTIVE: To assess impact of image quality on prostate cancer extraprostatic extension (EPE) detection on MRI using a deep learning-based AI algorithm. MATERIALS AND METHODS: This retrospective, single institution study included patients who were imaged with mpMRI and subsequently underwent radical prostatectomy from June 2007 to August 2022. One genitourinary radiologist prospectively evaluated each patient using the NCI EPE grading system. Each T2WI was classified as low- or high-quality by a previously developed AI algorithm. Fisher's exact tests were performed to compare EPE detection metrics between low- and high-quality images. Univariable and multivariable analyses were conducted to assess the predictive value of image quality for pathological EPE. RESULTS: A total of 773 consecutive patients (median age 61 [IQR 56-67] years) were evaluated. At radical prostatectomy, 23% (180/773) of patients had EPE at pathology, and 41% (131/318) of positive EPE calls on mpMRI were confirmed to have EPE. The AI algorithm classified 36% (280/773) of T2WIs as low-quality and 64% (493/773) as high-quality. For EPE grade ≥ 1, high-quality T2WI significantly improved specificity for EPE detection (72% [95% CI 67-76%] vs. 63% [95% CI 56-69%], P = 0.03), but did not significantly affect sensitivity (72% [95% CI 62-80%] vs. 75% [95% CI 63-85%]), positive predictive value (44% [95% CI 39-49%] vs. 38% [95% CI 32-43%]), or negative predictive value (89% [95% CI 86-92%] vs. 89% [95% CI 85-93%]). Sensitivity, specificity, PPV, and NPV for EPE grades ≥ 2 and ≥ 3 did not show significant differences attributable to imaging quality. For NCI EPE grade 1, high-quality images (OR 3.05, 95% CI 1.54-5.86; P < 0.001) demonstrated a stronger association with pathologic EPE than low-quality images (OR 1.76, 95% CI 0.63-4.24; P = 0.24). CONCLUSION: Our study successfully employed a deep learning-based AI algorithm to classify image quality of prostate MRI and demonstrated that better quality T2WI was associated with more accurate prediction of EPE at final pathology.


Asunto(s)
Aprendizaje Profundo , Imagen por Resonancia Magnética , Prostatectomía , Neoplasias de la Próstata , Humanos , Masculino , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Neoplasias de la Próstata/cirugía , Persona de Mediana Edad , Estudios Retrospectivos , Anciano , Imagen por Resonancia Magnética/métodos , Algoritmos , Interpretación de Imagen Asistida por Computador/métodos , Clasificación del Tumor
11.
Radiology ; 311(2): e230750, 2024 05.
Artículo en Inglés | MEDLINE | ID: mdl-38713024

RESUMEN

Background Multiparametric MRI (mpMRI) improves prostate cancer (PCa) detection compared with systematic biopsy, but its interpretation is prone to interreader variation, which results in performance inconsistency. Artificial intelligence (AI) models can assist in mpMRI interpretation, but large training data sets and extensive model testing are required. Purpose To evaluate a biparametric MRI AI algorithm for intraprostatic lesion detection and segmentation and to compare its performance with radiologist readings and biopsy results. Materials and Methods This secondary analysis of a prospective registry included consecutive patients with suspected or known PCa who underwent mpMRI, US-guided systematic biopsy, or combined systematic and MRI/US fusion-guided biopsy between April 2019 and September 2022. All lesions were prospectively evaluated using Prostate Imaging Reporting and Data System version 2.1. The lesion- and participant-level performance of a previously developed cascaded deep learning algorithm was compared with histopathologic outcomes and radiologist readings using sensitivity, positive predictive value (PPV), and Dice similarity coefficient (DSC). Results A total of 658 male participants (median age, 67 years [IQR, 61-71 years]) with 1029 MRI-visible lesions were included. At histopathologic analysis, 45% (294 of 658) of participants had lesions of International Society of Urological Pathology (ISUP) grade group (GG) 2 or higher. The algorithm identified 96% (282 of 294; 95% CI: 94%, 98%) of all participants with clinically significant PCa, whereas the radiologist identified 98% (287 of 294; 95% CI: 96%, 99%; P = .23). The algorithm identified 84% (103 of 122), 96% (152 of 159), 96% (47 of 49), 95% (38 of 40), and 98% (45 of 46) of participants with ISUP GG 1, 2, 3, 4, and 5 lesions, respectively. In the lesion-level analysis using radiologist ground truth, the detection sensitivity was 55% (569 of 1029; 95% CI: 52%, 58%), and the PPV was 57% (535 of 934; 95% CI: 54%, 61%). The mean number of false-positive lesions per participant was 0.61 (range, 0-3). The lesion segmentation DSC was 0.29. Conclusion The AI algorithm detected cancer-suspicious lesions on biparametric MRI scans with a performance comparable to that of an experienced radiologist. Moreover, the algorithm reliably predicted clinically significant lesions at histopathologic examination. ClinicalTrials.gov Identifier: NCT03354416 © RSNA, 2024 Supplemental material is available for this article.


Asunto(s)
Aprendizaje Profundo , Imágenes de Resonancia Magnética Multiparamétrica , Neoplasias de la Próstata , Masculino , Humanos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Anciano , Estudios Prospectivos , Imágenes de Resonancia Magnética Multiparamétrica/métodos , Persona de Mediana Edad , Algoritmos , Próstata/diagnóstico por imagen , Próstata/patología , Biopsia Guiada por Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos
12.
Oncotarget ; 15: 288-300, 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38712741

RESUMEN

PURPOSE: Sequential PET/CT studies oncology patients can undergo during their treatment follow-up course is limited by radiation dosage. We propose an artificial intelligence (AI) tool to produce attenuation-corrected PET (AC-PET) images from non-attenuation-corrected PET (NAC-PET) images to reduce need for low-dose CT scans. METHODS: A deep learning algorithm based on 2D Pix-2-Pix generative adversarial network (GAN) architecture was developed from paired AC-PET and NAC-PET images. 18F-DCFPyL PSMA PET-CT studies from 302 prostate cancer patients, split into training, validation, and testing cohorts (n = 183, 60, 59, respectively). Models were trained with two normalization strategies: Standard Uptake Value (SUV)-based and SUV-Nyul-based. Scan-level performance was evaluated by normalized mean square error (NMSE), mean absolute error (MAE), structural similarity index (SSIM), and peak signal-to-noise ratio (PSNR). Lesion-level analysis was performed in regions-of-interest prospectively from nuclear medicine physicians. SUV metrics were evaluated using intraclass correlation coefficient (ICC), repeatability coefficient (RC), and linear mixed-effects modeling. RESULTS: Median NMSE, MAE, SSIM, and PSNR were 13.26%, 3.59%, 0.891, and 26.82, respectively, in the independent test cohort. ICC for SUVmax and SUVmean were 0.88 and 0.89, which indicated a high correlation between original and AI-generated quantitative imaging markers. Lesion location, density (Hounsfield units), and lesion uptake were all shown to impact relative error in generated SUV metrics (all p < 0.05). CONCLUSION: The Pix-2-Pix GAN model for generating AC-PET demonstrates SUV metrics that highly correlate with original images. AI-generated PET images show clinical potential for reducing the need for CT scans for attenuation correction while preserving quantitative markers and image quality.


Asunto(s)
Aprendizaje Profundo , Tomografía Computarizada por Tomografía de Emisión de Positrones , Neoplasias de la Próstata , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Masculino , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Anciano , Persona de Mediana Edad , Glutamato Carboxipeptidasa II/metabolismo , Antígenos de Superficie/metabolismo , Procesamiento de Imagen Asistido por Computador/métodos , Algoritmos , Radiofármacos , Reproducibilidad de los Resultados
13.
Clin Nucl Med ; 49(7): 630-636, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38651785

RESUMEN

PURPOSE: Prostate-specific membrane antigen (PSMA)-targeting PET radiotracers reveal physiologic uptake in the urinary system, potentially misrepresenting activity in the prostatic urethra as an intraprostatic lesion. This study examined the correlation between midline 18 F-DCFPyL activity in the prostate and hyperintensity on T2-weighted (T2W) MRI as an indication of retained urine in the prostatic urethra. PATIENTS AND METHODS: Eighty-five patients who underwent both 18 F-DCFPyL PSMA PET/CT and prostate MRI between July 2017 and September 2023 were retrospectively analyzed for midline radiotracer activity and retained urine on postvoid T2W MRIs. Fisher's exact tests and unpaired t tests were used to compare residual urine presence and prostatic urethra measurements between patients with and without midline radiotracer activity. The influence of anatomical factors including prostate volume and urethral curvature on urinary stagnation was also explored. RESULTS: Midline activity on PSMA PET imaging was seen in 14 patients included in the case group, whereas the remaining 71 with no midline activity constituted the control group. A total of 71.4% (10/14) and 29.6% (21/71) of patients in the case and control groups had urethral hyperintensity on T2W MRI, respectively ( P < 0.01). Patients in the case group had significantly larger mean urethral dimensions, larger prostate volumes, and higher incidence of severe urethral curvature compared with the controls. CONCLUSIONS: Stagnated urine within the prostatic urethra is a potential confounding factor on PSMA PET scans. Integrating PET imaging with T2W MRI can mitigate false-positive calls, especially as PSMA PET/CT continues to gain traction in diagnosing localized prostate cancer.


Asunto(s)
Imagen por Resonancia Magnética , Tomografía Computarizada por Tomografía de Emisión de Positrones , Uretra , Humanos , Masculino , Reacciones Falso Positivas , Anciano , Uretra/diagnóstico por imagen , Persona de Mediana Edad , Estudios Retrospectivos , Lisina/análogos & derivados , Próstata/diagnóstico por imagen , Urea/análogos & derivados , Urea/farmacocinética , Glutamato Carboxipeptidasa II , Neoplasias de la Próstata/diagnóstico por imagen , Antígenos de Superficie , Anciano de 80 o más Años
14.
Acad Radiol ; 31(10): 4096-4106, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38670874

RESUMEN

RATIONALE AND OBJECTIVES: Extraprostatic extension (EPE) is well established as a significant predictor of prostate cancer aggression and recurrence. Accurate EPE assessment prior to radical prostatectomy can impact surgical approach. We aimed to utilize a deep learning-based AI workflow for automated EPE grading from prostate T2W MRI, ADC map, and High B DWI. MATERIAL AND METHODS: An expert genitourinary radiologist conducted prospective clinical assessments of MRI scans for 634 patients and assigned risk for EPE using a grading technique. The training set and held-out independent test set consisted of 507 patients and 127 patients, respectively. Existing deep-learning AI models for prostate organ and lesion segmentation were leveraged to extract area and distance features for random forest classification models. Model performance was evaluated using balanced accuracy, ROC AUCs for each EPE grade, as well as sensitivity, specificity, and accuracy compared to EPE on histopathology. RESULTS: A balanced accuracy score of .390 ± 0.078 was achieved using a lesion detection probability threshold of 0.45 and distance features. Using the test set, ROC AUCs for AI-assigned EPE grades 0-3 were 0.70, 0.65, 0.68, and 0.55 respectively. When using EPE≥ 1 as the threshold for positive EPE, the model achieved a sensitivity of 0.67, specificity of 0.73, and accuracy of 0.72 compared to radiologist sensitivity of 0.81, specificity of 0.62, and accuracy of 0.66 using histopathology as the ground truth. CONCLUSION: Our AI workflow for assigning imaging-based EPE grades achieves an accuracy for predicting histologic EPE approaching that of physicians. This automated workflow has the potential to enhance physician decision-making for assessing the risk of EPE in patients undergoing treatment for prostate cancer due to its consistency and automation.


Asunto(s)
Aprendizaje Profundo , Imagen por Resonancia Magnética , Clasificación del Tumor , Neoplasias de la Próstata , Sensibilidad y Especificidad , Humanos , Masculino , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Neoplasias de la Próstata/cirugía , Imagen por Resonancia Magnética/métodos , Estudios Prospectivos , Persona de Mediana Edad , Anciano , Interpretación de Imagen Asistida por Computador/métodos , Prostatectomía , Bosques Aleatorios
15.
Eur Urol ; 86(3): 240-255, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38556436

RESUMEN

BACKGROUND AND OBJECTIVE: The Prostate Cancer Radiological Estimation of Change in Sequential Evaluation (PRECISE) recommendations standardise the reporting of prostate magnetic resonance imaging (MRI) in patients on active surveillance (AS) for prostate cancer. An international consensus group recently updated these recommendations and identified the areas of uncertainty. METHODS: A panel of 38 experts used the formal RAND/UCLA Appropriateness Method consensus methodology. Panellists scored 193 statements using a 1-9 agreement scale, where 9 means full agreement. A summary of agreement, uncertainty, or disagreement (derived from the group median score) and consensus (determined using the Interpercentile Range Adjusted for Symmetry method) was calculated for each statement and presented for discussion before individual rescoring. KEY FINDINGS AND LIMITATIONS: Participants agreed that MRI scans must meet a minimum image quality standard (median 9) or be given a score of 'X' for insufficient quality. The current scan should be compared with both baseline and previous scans (median 9), with the PRECISE score being the maximum from any lesion (median 8). PRECISE 3 (stable MRI) was subdivided into 3-V (visible) and 3-NonV (nonvisible) disease (median 9). Prostate Imaging Reporting and Data System/Likert ≥3 lesions should be measured on T2-weighted imaging, using other sequences to aid in the identification (median 8), and whenever possible, reported pictorially (diagrams, screenshots, or contours; median 9). There was no consensus on how to measure tumour size. More research is needed to determine a significant size increase (median 9). PRECISE 5 was clarified as progression to stage ≥T3a (median 9). CONCLUSIONS AND CLINICAL IMPLICATIONS: The updated PRECISE recommendations reflect expert consensus opinion on minimal standards and reporting criteria for prostate MRI in AS.


Asunto(s)
Consenso , Imagen por Resonancia Magnética , Neoplasias de la Próstata , Espera Vigilante , Humanos , Masculino , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Imagen por Resonancia Magnética/normas , Espera Vigilante/normas , Próstata/diagnóstico por imagen , Próstata/patología
16.
Abdom Radiol (NY) ; 49(5): 1545-1556, 2024 05.
Artículo en Inglés | MEDLINE | ID: mdl-38512516

RESUMEN

OBJECTIVE: Automated methods for prostate segmentation on MRI are typically developed under ideal scanning and anatomical conditions. This study evaluates three different prostate segmentation AI algorithms in a challenging population of patients with prior treatments, variable anatomic characteristics, complex clinical history, or atypical MRI acquisition parameters. MATERIALS AND METHODS: A single institution retrospective database was queried for the following conditions at prostate MRI: prior prostate-specific oncologic treatment, transurethral resection of the prostate (TURP), abdominal perineal resection (APR), hip prosthesis (HP), diversity of prostate volumes (large ≥ 150 cc, small ≤ 25 cc), whole gland tumor burden, magnet strength, noted poor quality, and various scanners (outside/vendors). Final inclusion criteria required availability of axial T2-weighted (T2W) sequence and corresponding prostate organ segmentation from an expert radiologist. Three previously developed algorithms were evaluated: (1) deep learning (DL)-based model, (2) commercially available shape-based model, and (3) federated DL-based model. Dice Similarity Coefficient (DSC) was calculated compared to expert. DSC by model and scan factors were evaluated with Wilcox signed-rank test and linear mixed effects (LMER) model. RESULTS: 683 scans (651 patients) met inclusion criteria (mean prostate volume 60.1 cc [9.05-329 cc]). Overall DSC scores for models 1, 2, and 3 were 0.916 (0.707-0.971), 0.873 (0-0.997), and 0.894 (0.025-0.961), respectively, with DL-based models demonstrating significantly higher performance (p < 0.01). In sub-group analysis by factors, Model 1 outperformed Model 2 (all p < 0.05) and Model 3 (all p < 0.001). Performance of all models was negatively impacted by prostate volume and poor signal quality (p < 0.01). Shape-based factors influenced DL models (p < 0.001) while signal factors influenced all (p < 0.001). CONCLUSION: Factors affecting anatomical and signal conditions of the prostate gland can adversely impact both DL and non-deep learning-based segmentation models.


Asunto(s)
Algoritmos , Inteligencia Artificial , Imagen por Resonancia Magnética , Neoplasias de la Próstata , Humanos , Masculino , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/cirugía , Neoplasias de la Próstata/patología , Interpretación de Imagen Asistida por Computador/métodos , Persona de Mediana Edad , Anciano , Próstata/diagnóstico por imagen , Aprendizaje Profundo
17.
Eur Urol Open Sci ; 62: 74-80, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38468864

RESUMEN

Background and objective: Focal therapy (FT) is increasingly recognized as a promising approach for managing localized prostate cancer (PCa), notably reducing treatment-related morbidities. However, post-treatment anatomical changes present significant challenges for surveillance using current imaging techniques. This study aimed to evaluate the inter-reader agreement and efficacy of the Prostate Imaging after Focal Ablation (PI-FAB) scoring system in detecting clinically significant prostate cancer (csPCa) on post-FT multiparametric magnetic resonance imaging (mpMRI). Methods: A retrospective cohort study was conducted involving patients who underwent primary FT for localized csPCa between 2013 and 2023, followed by post-FT mpMRI and a prostate biopsy. Two expert genitourinary radiologists retrospectively evaluated post-FT mpMRI using PI-FAB. The key measures included inter-reader agreement of PI-FAB scores, assessed by quadratic weighted Cohen's kappa (κ), and the system's efficacy in predicting in-field recurrence of csPCa, with a PI-FAB score cutoff of 3. Additional diagnostic metrics including sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and overall accuracy were also evaluated. Key findings and limitations: Scans from 38 patients were analyzed, revealing a moderate level of agreement in PI-FAB scoring (κ = 0.56). Both radiologists achieved sensitivity of 93% in detecting csPCa, although specificity, PPVs, NPVs, and accuracy varied. Conclusions and clinical implications: The PI-FAB scoring system exhibited high sensitivity with moderate inter-reader agreement in detecting in-field recurrence of csPCa. Despite promising results, its low specificity and PPV necessitate further refinement. These findings underscore the need for larger studies to validate the clinical utility of PI-FAB, potentially aiding in standardizing post-treatment surveillance. Patient summary: Focal therapy has emerged as a promising approach for managing localized prostate cancer, but limitations in current imaging techniques present significant challenges for post-treatment surveillance. The Prostate Imaging after Focal Ablation (PI-FAB) scoring system showed high sensitivity for detecting in-field recurrence of clinically significant prostate cancer. However, its low specificity and positive predictive value necessitate further refinement. Larger, more comprehensive studies are needed to fully validate its clinical utility.

18.
medRxiv ; 2024 Feb 11.
Artículo en Inglés | MEDLINE | ID: mdl-38370835

RESUMEN

Patients diagnosed with localized high-risk prostate cancer have higher rates of recurrence, and the introduction of neoadjuvant intensive hormonal therapies seeks to treat occult micrometastatic disease by their addition to definitive treatment. Sufficient profiling of baseline disease has remained a challenge in enabling the in-depth assessment of phenotypes associated with exceptional vs. poor pathologic responses after treatment. In this study, we report comprehensive and integrative gene expression profiling of 37 locally advanced prostate tumors prior to six months of androgen deprivation therapy (ADT) plus the androgen receptor (AR) inhibitor enzalutamide prior to radical prostatectomy. A robust transcriptional program associated with HER2 activity was positively associated with poor outcome and opposed AR activity, even after adjusting for common genomic alterations in prostate cancer including PTEN loss and expression of the TMPRSS2:ERG fusion. Patients experiencing exceptional pathologic responses demonstrated lower levels of HER2 and phospho-HER2 by immunohistochemistry of biopsy tissues. The inverse correlation of AR and HER2 activity was found to be a universal feature of all aggressive prostate tumors, validated by transcriptional profiling an external cohort of 121 patients and immunostaining of tumors from 84 additional patients. Importantly, the AR activity-low, HER2 activity-high cells that resist ADT are a pre-existing subset of cells that can be targeted by HER2 inhibition alone or in combination with enzalutamide. In summary, we show that prostate tumors adopt an AR activity-low prior to antiandrogen exposure that can be exploited by treatment with HER2 inhibitors.

19.
Acad Radiol ; 31(6): 2424-2433, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38262813

RESUMEN

RATIONALE AND OBJECTIVES: Efficiently detecting and characterizing metastatic bone lesions on staging CT is crucial for prostate cancer (PCa) care. However, it demands significant expert time and additional imaging such as PET/CT. We aimed to develop an ensemble of two automated deep learning AI models for 1) bone lesion detection and segmentation and 2) benign vs. metastatic lesion classification on staging CTs and to compare its performance with radiologists. MATERIALS AND METHODS: This retrospective study developed two AI models using 297 staging CT scans (81 metastatic) with 4601 benign and 1911 metastatic lesions in PCa patients. Metastases were validated by follow-up scans, bone biopsy, or PET/CT. Segmentation AI (3DAISeg) was developed using the lesion contours delineated by a radiologist. 3DAISeg performance was evaluated with the Dice similarity coefficient, and classification AI (3DAIClass) performance on AI and radiologist contours was assessed with F1-score and accuracy. Training/validation/testing data partitions of 70:15:15 were used. A multi-reader study was performed with two junior and two senior radiologists within a subset of the testing dataset (n = 36). RESULTS: In 45 unseen staging CT scans (12 metastatic PCa) with 669 benign and 364 metastatic lesions, 3DAISeg detected 73.1% of metastatic (266/364) and 72.4% of benign lesions (484/669). Each scan averaged 12 extra segmentations (range: 1-31). All metastatic scans had at least one detected metastatic lesion, achieving a 100% patient-level detection. The mean Dice score for 3DAISeg was 0.53 (median: 0.59, range: 0-0.87). The F1 for 3DAIClass was 94.8% (radiologist contours) and 92.4% (3DAISeg contours), with a median false positive of 0 (range: 0-3). Using radiologist contours, 3DAIClass had PPV and NPV rates comparable to junior and senior radiologists: PPV (semi-automated approach AI 40.0% vs. Juniors 32.0% vs. Seniors 50.0%) and NPV (AI 96.2% vs. Juniors 95.7% vs. Seniors 91.9%). When using 3DAISeg, 3DAIClass mimicked junior radiologists in PPV (pure-AI 20.0% vs. Juniors 32.0% vs. Seniors 50.0%) but surpassed seniors in NPV (pure-AI 93.8% vs. Juniors 95.7% vs. Seniors 91.9%). CONCLUSION: Our lesion detection and classification AI model performs on par with junior and senior radiologists in discerning benign and metastatic lesions on staging CTs obtained for PCa.


Asunto(s)
Neoplasias Óseas , Aprendizaje Profundo , Estadificación de Neoplasias , Neoplasias de la Próstata , Tomografía Computarizada por Rayos X , Humanos , Masculino , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Neoplasias Óseas/diagnóstico por imagen , Neoplasias Óseas/secundario , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Anciano , Persona de Mediana Edad , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
20.
AJR Am J Roentgenol ; 222(1): e2329964, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37729551

RESUMEN

BACKGROUND. Precise risk stratification through MRI/ultrasound (US) fusion-guided targeted biopsy (TBx) can guide optimal prostate cancer (PCa) management. OBJECTIVE. The purpose of this study was to compare PI-RADS version 2.0 (v2.0) and PI-RADS version 2.1 (v2.1) in terms of the rates of International Society of Urological Pathology (ISUP) grade group (GG) upgrade and downgrade from TBx to radical prostatectomy (RP). METHODS. This study entailed a retrospective post hoc analysis of patients who underwent 3-T prostate MRI at a single institution from May 2015 to March 2023 as part of three prospective clinical trials. Trial participants who underwent MRI followed by MRI/US fusion-guided TBx and RP within a 1-year interval were identified. A single genitourinary radiologist performed clinical interpretations of the MRI examinations using PI-RADS v2.0 from May 2015 to March 2019 and PI-RADS v2.1 from April 2019 to March 2023. Upgrade and downgrade rates from TBx to RP were compared using chi-square tests. Clinically significant cancer was defined as ISUP GG2 or greater. RESULTS. The final analysis included 308 patients (median age, 65 years; median PSA density, 0.16 ng/mL2). The v2.0 group (n = 177) and v2.1 group (n = 131) showed no significant difference in terms of upgrade rate (29% vs 22%, respectively; p = .15), downgrade rate (19% vs 21%, p = .76), clinically significant upgrade rate (14% vs 10%, p = .27), or clinically significant downgrade rate (1% vs 1%, p > .99). The upgrade rate and downgrade rate were also not significantly different between the v2.0 and v2.1 groups when stratifying by index lesion PI-RADS category or index lesion zone, as well as when assessed only in patients without a prior PCa diagnosis (all p > .01). Among patients with GG2 or GG3 at RP (n = 121 for v2.0; n = 103 for v2.1), the concordance rate between TBx and RP was not significantly different between the v2.0 and v2.1 groups (53% vs 57%, p = .51). CONCLUSION. Upgrade and downgrade rates from TBx to RP were not significantly different between patients whose MRI examinations were clinically interpreted using v2.0 or v2.1. CLINICAL IMPACT. Implementation of the most recent PI-RADS update did not improve the incongruence in PCa grade assessment between TBx and surgery.


Asunto(s)
Neoplasias de la Próstata , Masculino , Humanos , Anciano , Neoplasias de la Próstata/patología , Imagen por Resonancia Magnética/métodos , Próstata/patología , Estudios Retrospectivos , Estudios Prospectivos , Biopsia , Prostatectomía/métodos , Biopsia Guiada por Imagen/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA