Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 314
Filtrar
1.
Adv Healthc Mater ; : e2400946, 2024 May 12.
Artículo en Inglés | MEDLINE | ID: mdl-38736024

RESUMEN

Current research in cancer therapy focuses on personalized therapies, through nanotechnology-based targeted drug delivery systems. Particularly, controlled drug release with nanoparticles (NPs) can be designed to safely transport various active agents, optimizing delivery to specific organs and tumors, minimizing side effects. The use of microfluidics (MFs) in this field has stood out against conventional methods by allowing precise control over parameters like size, structure, composition, and mechanical/biological properties of nanoscale carriers. This review compiles applications of microfluidics in the production of core-shell NPs (CSNPs) for cancer therapy, discussing the versatility inherent in various microchannel and/or micromixer setups and showcasing how these setups can be utilized individually or in combination, as well as how this technology allows the development of new advances in more efficient and controlled fabrication of core-shell nanoformulations. Recent biological studies have achieved an effective, safe, and controlled delivery of otherwise unreliable encapsulants such as small interfering RNA (siRNA), plasmid DNA (pDNA), and cisplatin as a result of precisely tuned fabrication of nanocarriers, showing that this technology is paving the way for innovative strategies in cancer therapy nanofabrication, characterized by continuous production and high reproducibility. Finally, this review analyzes the technical, biological, and technological limitations that currently prevent this technology from becoming the standard.

2.
Nat Commun ; 15(1): 3182, 2024 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-38609352

RESUMEN

Huntington's disease (HD) is a dominant neurological disorder caused by an expanded HTT exon 1 CAG repeat that lengthens huntingtin's polyglutamine tract. Lowering mutant huntingtin has been proposed for treating HD, but genetic modifiers implicate somatic CAG repeat expansion as the driver of onset. We find that branaplam and risdiplam, small molecule splice modulators that lower huntingtin by promoting HTT pseudoexon inclusion, also decrease expansion of an unstable HTT exon 1 CAG repeat in an engineered cell model. Targeted CRISPR-Cas9 editing shows this effect is not due to huntingtin lowering, pointing instead to pseudoexon inclusion in PMS1. Homozygous but not heterozygous inactivation of PMS1 also reduces CAG repeat expansion, supporting PMS1 as a genetic modifier of HD and a potential target for therapeutic intervention. Although splice modulation provides one strategy, genome-wide transcriptomics also emphasize consideration of cell-type specific effects and polymorphic variation at both target and off-target sites.


Asunto(s)
Enfermedad de Huntington , Humanos , Enfermedad de Huntington/genética , Exones/genética , Perfilación de la Expresión Génica , Heterocigoto , Homocigoto , Proteínas MutL , Proteínas de Neoplasias
3.
Gels ; 10(4)2024 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-38667693

RESUMEN

Biopolymeric nanoparticles (NPs) have gained significant attention in several areas as an alternative to synthetic polymeric NPs due to growing environmental and immunological concerns. Among the most promising biopolymers is poly(lactic acid) (PLA), with a reported high degree of biocompatibility and biodegradability. In this work, PLA NPs were synthesized according to a controlled gelation process using a combination of single-emulsion and nanoprecipitation methods. This study evaluated the influence of several experimental parameters for accurate control of the PLA NPs' size distribution and aggregation. Tip sonication (as the stirring method), a PLA concentration of 10 mg/mL, a PVA concentration of 2.5 mg/mL, and low-molecular-weight PLA (Mw = 5000) were established as the best experimental conditions to obtain monodisperse PLA NPs. After gelification process optimization, flutamide (FLU) was used as a model drug to evaluate the encapsulation capability of the PLA NPs. The results showed an encapsulation efficiency of 44% for this cytostatic compound. Furthermore, preliminary cell viability tests showed that the FLU@PLA NPs allowed cell viabilities above 90% up to a concentration of 20 mg/L. The comprehensive findings showcase that the PLA NPs fabricated using this straightforward gelification method hold promise for encapsulating cytostatic compounds, offering a novel avenue for precise drug delivery in cancer therapy.

4.
Rev Port Cardiol ; 2024 Apr 12.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-38615880

RESUMEN

INTRODUCTION AND OBJECTIVES: Idiopathic ventricular fibrillation (IVF) is diagnosed in patients who survive sudden cardiac arrest (SCA), preferably with documented ventricular fibrillation (VF), without any identifiable structural or electrical abnormality. Current evidence provides limited guidance on the diagnosis and follow-up of these patients. Our aim was to assess the clinical outcomes of survivors of an aborted SCA attributed to IVF. METHODS: We retrospectively collected clinical data from all patients who survived SCA and implanted a cardiac defibrillator (ICD) between 2005 and 2023. RESULTS: A total of 38 patients, 36.8% female, with a mean age of 44±14 years old were included. Median follow-up time was 8.7 years (interquartile range (IQR) 4.7-14.7 years). All patients underwent a comprehensive diagnostic evaluation that excluded structural and coronary disease. During follow-up, underlying diagnoses were established in 34.2% of the whole cohort. Genetic testing, performed in 37.2%, revealed underlying diagnoses in 57.1% of those tested, compared to only 26.3% of patients who did not undergo genetic testing [p=0.035, OR=5.1 (95% confidence interval (CI) 1.2-21.5)]. Mortality was 10.5% (due to non-arrhythmic causes) and 36.8% patients received appropriate therapies with a median time to first ICD therapy of 39 [5.4-47.3] months. CONCLUSION(S): Etiological diagnosis and recurrence prediction in patients with IVF remains challenging, even with extensive diagnostic evaluation and long-term follow-up. In our study, genetic testing enhanced diagnostic yield. Consistent with previous findings, our cohort experienced a notable arrhythmic recurrence, with no cardiac deaths, underlining the pivotal role of ICD implantation in these patients.

5.
Artículo en Inglés | MEDLINE | ID: mdl-38685613

RESUMEN

BACKGROUND: Adherence to Helicobacter pylori (H. pylori) eradication treatment is a cornerstone for achieving adequate treatment efficacy. OBJECTIVE: To determine which factors influence compliance with treatment. METHODS: A systematic prospective non-interventional registry (Hp-EuReg) of the clinical practice of European gastroenterologists. Compliance was considered adequate if ≥90% drug intake. Data were collected until September 2021 using the AEG-REDCap e-CRF and were subjected to quality control. Modified intention-to-treat analyses were performed. Multivariate analysis carried out the factors associated with the effectiveness of treatment and compliance. RESULTS: Compliance was inadequate in 646 (1.7%) of 38,698 patients. The non-compliance rate was higher in patients prescribed longer regimens (10-, 14-days) and rescue treatments, patients with uninvestigated dyspepsia/functional dyspepsia, and patients reporting adverse effects. Prevalence of non-adherence was lower for first-line treatment than for rescue treatment (1.5% vs. 2.2%; p < 0.001). Differences in non-adherence in the three most frequent first-line treatments were shown: 1.1% with proton pump inhibitor + clarithromycin + amoxicillin; 2.3% with proton pump inhibitor clarithromycin amoxicillin metronidazole; and 1.8% with bismuth quadruple therapy. These treatments were significantly more effective in compliant than in non-compliant patients: 86% versus 44%, 90% versus 71%, and 93% versus 64%, respectively (p < 0.001). In the multivariate analysis, the variable most significantly associated with higher effectiveness was adequate compliance (odds ratio, 6.3 [95%CI, 5.2-7.7]; p < 0.001). CONCLUSIONS: Compliance with Helicobacter pylori eradication treatment is very good. Factors associated with poor compliance include uninvestigated/functional dyspepsia, rescue-treatment, prolonged treatment regimens, the presence of adverse events, and the use of non-bismuth sequential and concomitant treatment. Adequate treatment compliance was the variable most closely associated with successful eradication.

6.
Artículo en Inglés | MEDLINE | ID: mdl-38470469

RESUMEN

Percutaneous mitral valve commissurotomy (PMC) is a viable alternative to mitral valve (MV) surgery in the treatment of patients with rheumatic mitral stenosis (RMS). In this single-center retrospective study of consecutive patients with RMS submitted to PMC from 1991 to 2008, we analyzed clinical, echocardiographic, and hemodynamic data and events during follow-up (FUP) until December 2021. Major adverse cardiovascular events (MACE) were a combined endpoint of all-cause death, cardiovascular hospitalization, and MV re-intervention. A total of 124 patients were enrolled: 108 (87.1%) were female, with a mean age at PMC of 46 [standard deviation (SD) 11] years. PMC was successful in 91.1%, with a mean reduction in invasive transmitral pressure gradient (TMPG) of 8 (SD 7) mmHg at PMC time. During the mean FUP of 20 (SD 6) years, 51 (41.1%) patients had MV re-intervention (86.3% surgery and 13.7% redo-PMC), 37 (29.8%) were hospitalized, and 30 (24.2%) died. Approximately 75% of patients remained MACE-free after 10 years, and this percentage decreased to around 40% after 20 years; at this time mark, about 8 in 10 patients were alive. A reduction of <5 mmHg in TMPG at PMC time was associated with a 2.7-fold greater rate of MACE compared to a reduction of ≥5 mmHg, independent of MV regurgitation after PMC and moderate disease of other valves (adjusted hazard ratio 2,7; 95% confidence interval 1.395-5.298, p=0.003). In this cohort with favorable long-term results after PMC, a reduction of <5 mmHg in TMPG at PMC time was associated with MACE during FUP. More studies are needed to validate this independent predictor.

8.
Global Spine J ; 14(3_suppl): 174S-186S, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38526922

RESUMEN

STUDY DESIGN: Clinical practice guideline development. OBJECTIVES: Acute spinal cord injury (SCI) can result in devastating motor, sensory, and autonomic impairment; loss of independence; and reduced quality of life. Preclinical evidence suggests that early decompression of the spinal cord may help to limit secondary injury, reduce damage to the neural tissue, and improve functional outcomes. Emerging evidence indicates that "early" surgical decompression completed within 24 hours of injury also improves neurological recovery in patients with acute SCI. The objective of this clinical practice guideline (CPG) is to update the 2017 recommendations on the timing of surgical decompression and to evaluate the evidence with respect to ultra-early surgery (in particular, but not limited to, <12 hours after acute SCI). METHODS: A multidisciplinary, international, guideline development group (GDG) was formed that consisted of spine surgeons, neurologists, critical care specialists, emergency medicine doctors, physical medicine and rehabilitation professionals, as well as individuals living with SCI. A systematic review was conducted based on accepted methodological standards to evaluate the impact of early (within 24 hours of acute SCI) or ultra-early (in particular, but not limited to, within 12 hours of acute SCI) surgery on neurological recovery, functional outcomes, administrative outcomes, safety, and cost-effectiveness. The GRADE approach was used to rate the overall strength of evidence across studies for each primary outcome. Using the "evidence-to-recommendation" framework, recommendations were then developed that considered the balance of benefits and harms, financial impact, patient values, acceptability, and feasibility. The guideline was internally appraised using the Appraisal of Guidelines for Research and Evaluation (AGREE) II tool. RESULTS: The GDG recommended that early surgery (≤24 hours after injury) be offered as the preferred option for adult patients with acute SCI regardless of level. This recommendation was based on moderate evidence suggesting that patients were 2 times more likely to recover by ≥ 2 ASIA Impairment Score (AIS) grades at 6 months (RR: 2.76, 95% CI 1.60 to 4.98) and 12 months (RR: 1.95, 95% CI 1.26 to 3.18) if they were decompressed within 24 hours compared to after 24 hours. Furthermore, patients undergoing early surgery improved by an additional 4.50 (95% 1.70 to 7.29) points on the ASIA Motor Score compared to patients undergoing surgery after 24 hours post-injury. The GDG also agreed that a recommendation for ultra-early surgery could not be made on the basis of the current evidence because of the small sample sizes, variable definitions of what constituted ultra-early in the literature, and the inconsistency of the evidence. CONCLUSIONS: It is recommended that patients with an acute SCI, regardless of level, undergo surgery within 24 hours after injury when medically feasible. Future research is required to determine the differential effectiveness of early surgery in different subpopulations and the impact of ultra-early surgery on neurological recovery. Moreover, further work is required to define what constitutes effective spinal cord decompression and to individualize care. It is also recognized that a concerted international effort will be required to translate these recommendations into policy.

9.
Global Spine J ; 14(3_suppl): 212S-222S, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38526921

RESUMEN

STUDY DESIGN: Development of a clinical practice guideline following the Grading of Recommendations, Assessment, Development and Evaluation (GRADE) process. OBJECTIVE: The objectives of this study were to develop guidelines that outline the utility of intraoperative neuromonitoring (IONM) to detect intraoperative spinal cord injury (ISCI) among patients undergoing spine surgery, to define a subset of patients undergoing spine surgery at higher risk for ISCI and to develop protocols to prevent, diagnose, and manage ISCI. METHODS: All systematic reviews were performed according to PRISMA standards and registered on PROSPERO. A multidisciplinary, international Guidelines Development Group (GDG) reviewed and discussed the evidence using GRADE protocols. Consensus was defined by 80% agreement among GDG members. A systematic review and diagnostic test accuracy (DTA) meta-analysis was performed to synthesize pooled evidence on the diagnostic accuracy of IONM to detect ISCI among patients undergoing spinal surgery. The IONM modalities evaluated included somatosensory evoked potentials (SSEPs), motor evoked potentials (MEPs), electromyography (EMG), and multimodal neuromonitoring. Utilizing this knowledge and their clinical experience, the multidisciplinary GDG created recommendations for the use of IONM to identify ISCI in patients undergoing spine surgery. The evidence related to existing care pathways to manage ISCI was summarized and based on this a novel AO Spine-PRAXIS care pathway was created. RESULTS: Our recommendations are as follows: (1) We recommend that intraoperative neurophysiological monitoring be employed for high risk patients undergoing spine surgery, and (2) We suggest that patients at "high risk" for ISCI during spine surgery be proactively identified, that after identification of such patients, multi-disciplinary team discussions be undertaken to manage patients, and that an intraoperative protocol including the use of IONM be implemented. A care pathway for the prevention, diagnosis, and management of ISCI has been developed by the GDG. CONCLUSION: We anticipate that these guidelines will promote the use of IONM to detect and manage ISCI, and promote the use of preoperative and intraoperative checklists by surgeons and other team members for high risk patients undergoing spine surgery. We welcome teams to implement and evaluate the care pathway created by our GDG.

10.
Int J Prosthodont ; 37(1): 109, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38381990

RESUMEN

PURPOSE: To evaluate the in vitro accuracy of impressions obtained with two silicone and corresponding stone models using two laboratory scanners. MATERIALS AND METHODS: A master model with synthetic resin teeth with two single-unit crown preparations was created and scanned using a 12-megapixel scanner. Five conventional impressions of the physical model were prepared with different silicone impression systems (Zhermack and Coltene) using the double-mix technique and poured with gypsum. The impressions and stone models obtained were scanned using two extraoral scanning systems (Identica T500, Medit; S600 ARTI, Zirkonzahn). All best-fit superimpositions of the teeth areas were conducted between the master model and the scans of the impressions and models obtained with the two scanners. A P < .05 level was considered significant. RESULTS: The Identica T500 Medit scanner showed an accuracy of 102.34 (89.67, 115.01) µm for Coltene silicone and 79.51 (67.82, 91.21) µm for Zhermack silicone, while the S600 ARTI Zirkonzhan scanner presented 110.79 (98.24, 123.33) µm and 91.91 (81.29, 102.54) µm, respectively, with significant differences between scanners for Zhermack silicone (P = .008) and for the corresponding stone models (P = .002). Zhermack silicone presented overall discrepancies lower than Coltene silicone, with statistically significant differences in both scanners analyzed (P < .001; P = .017). However, the discrepancies found were within clinically acceptable values. With the Zirkonzahn scanner, discrepancies found in the Zhermack impressions were lower than in the corresponding stone models (P < .001). CONCLUSIONS: The direct digitization of silicone impressions with laboratory scanners presented comparable results to conventional techniques with stone models.


Asunto(s)
Imagenología Tridimensional , Diente , Siliconas , Técnica de Impresión Dental , Diseño Asistido por Computadora , Materiales de Impresión Dental
11.
Int Endod J ; 57(5): 601-616, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38376108

RESUMEN

AIM: To compare eight large- and low-tapered heat-treated reciprocating instruments regarding their design, metallurgy, mechanical properties, and irrigation flow through an in silico model. METHODOLOGY: A total of 472 new 25-mm E-Flex Rex (25/.04 and 25/.06), Excalibur (25/.05), Procodile (25/.06), Reciproc Blue R25 (25/.08v), WaveOne Gold Primary (25/.07v), and Univy Sense (25/.04 and 25/.06) instruments were evaluated regarding their design (stereomicroscopy, scanning electron microscopy, and 3D surface scanning), metallurgy (energy-dispersive X-ray spectroscopy and differential scanning calorimetry), and mechanical performance (cyclic fatigue, torsional resistance, cutting ability, bending and buckling resistance). Computational fluid dynamics assessment was also conducted to determine the irrigation flow pattern, apical pressure, and wall shear stress in simulated canal preparations. Kruskal-Wallis and one-way anova post hoc Tukey tests were used for statistical comparisons (α = 5%). RESULTS: Instruments presented variations in blade numbers, helical angles, and tip designs, with all featuring non-active tips, symmetrical blades, and equiatomic nickel-titanium ratios. Cross-sectional designs exhibited an S-shaped geometry, except for WaveOne Gold. Univy 25/.04 and Reciproc Blue displayed the smallest and largest core diameters at D3. Univy 25/.04 and E-Flex Rec 25/.04 demonstrated the longest time to fracture (p < .05). Reciproc Blue and Univy 25/.04 exhibited the highest and lowest torque to fracture, respectively (p < .05). Univy 25/.04 and Reciproc Blue had the highest rotation angles, whilst E-Flex Rec 25/.06 showed the lowest angle (p < .05). The better cutting ability was observed with E-Flex Rec 25/.06, Procodile, Excalibur, and Reciproc Blue (p > .05). Reciproc R25 and E-Flex Rec showed the highest buckling resistance values (p < .05), with WaveOne Gold being the least flexible instrument. The impact of instruments' size and taper on wall shear stress and apical pressure did not follow a distinct pattern, although Univy 25/.04 and E-Flex Rec 25/.06 yielded the highest and lowest values for both parameters, respectively. CONCLUSIONS: Low-tapered reciprocating instruments exhibit increased flexibility, higher time to fracture, and greater angles of rotation, coupled with reduced maximum bending loads and buckling strength compared to large-tapered instruments. Nevertheless, low-tapered systems also exhibit lower maximum torque to fracture and inferior cutting ability, contributing to a narrower apical canal enlargement that may compromise the penetration of irrigants in that region.


Asunto(s)
Instrumentos Dentales , Titanio , Estudios Transversales , Diseño de Equipo , Ensayo de Materiales , Estrés Mecánico , Titanio/química , Preparación del Conducto Radicular , Metalurgia
12.
Global Spine J ; 14(2_suppl): 86S-93S, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38421321

RESUMEN

STUDY DESIGN: Systematic review. OBJECTIVES: The aim of this study is to analyze the complications related to multilevel anterior cervical discectomy and fusion (ACDF) using osteobiologics other than bone morphogenetic protein (BMP). METHODS: A systematic review of the literature was conducted using PubMed, EMBASE, Cochrane Library, and ClinicalTrials.gov databases. The search to identify studies reporting complications in multilevel ACDF surgery using osteobiologics other than bone morphogenetic protein was performed in August 2020. The study was reported in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA). RESULTS: A total of 584 articles were found after searching the databases and removing duplicates. Next, screening was performed in a double reviewer process, and 153 eligible articles-with 4 retrospective studies-in full-text were selected; these met all inclusion criteria. A total of 197 patients received 3-level ACDF, while 72 patients received 4-level ACDF. Osteobiologics were used in all selected articles, allograft was used in 4 studies, autologous bone graft was utilized in 3 articles, and hydroxyapatite was used in 1 article. The main complications reported were dysphagia, adjacent segment disease, and pseudarthrosis. CONCLUSIONS: Given the limited evidence, no conclusions on complications in multilevel ACDF using osteobiologics other than BMP could be made. However, descriptively, the most common complications found were dysphagia, adjacent segment disease, and pseudoarthrosis. Further prospective studies separately analyzing complications in multilevel ACDF by osteobiologics and a number of treated levels are needed.

13.
Global Spine J ; 14(2_suppl): 70S-77S, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38421325

RESUMEN

Study Design: Systematic literature reviewObjective: To critically analyze the literature and describe the complications associated with the use of allograft in 1- or 2- level anterior cervical discectomy and fusion (ACDF)Methods: A systematic search of PubMed/MEDLINE, EMBASE, and ClinicalTrials.gov databases was conducted for literature published between January 2000 and August 2020 reporting complications associated with the use of allograft in 1- or 2- level ACDF.Results: From 584 potentially relevant citations, 21 met the inclusion criteria (4 randomized controlled trials (RCT), 4 prospective, and 13 retrospective studies). The patient number varied between 26 and 463 in comparative studies (RCT and non-RCT) and between 29 and 345 in non-comparative studies. Fusion rate was reported in 14 studies and ranged between 68.5-100%. The most frequently reported complication was post-operative dysphagia or dysphonia, with incidences ranging between .5% and 14.4%. Revision surgery was the second most reported complication (14 studies) and ranged between 0% and 10.3%. Wound-related complications were reported in 6 studies and ranged between 0% and 22.8%.Conclusion: The overall reporting of complications was low with very few comparative studies. Reported complications with allografts are within the range of other osteobiologics and autografts and in most cases may not attributable to the use of osteobiologics and may be complications of the procedure itself. Comparative studies with a more robust methodology analyzing complications with allograft and other osteobiologics are needed to inform current practice with strong recommendations.

14.
Global Spine J ; 14(2_suppl): 173S-178S, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38421324

RESUMEN

STUDY DESIGN: Systematic literature review. OBJECTIVE: To analyze the literature and describe the evidence supporting osteobiologic use in revision anterior cervical discectomy and fusion (ACDF) surgery. METHODS: A systematic search of PubMed/MEDLINE, EMBASE, Cochrane library, and ClinicalTrials.gov databases was conducted for literature reporting the use of osteobiologics in revision ACDF. We searched for studies reporting outcomes of using any osteobiologic use in revision ACDF surgeries (independently of the number of levels) in the above databases. RESULTS: There are currently no studies in the literature describing the outcome and comparative efficacy of diverse osteobiologic agents in the context of revision ACDF surgery. A majority of the current evidence is based only upon studies involving primary ACDF surgery. CONCLUSION: The current study highlights the paucity of literature evidence on the role of diverse osteobiologics in revision ACDF, and foregrounds the need for high-quality evidence on this subject.

15.
Global Spine J ; 14(2_suppl): 6S-13S, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38421322

RESUMEN

STUDY DESIGN: Guideline. OBJECTIVES: To develop an international guideline (AOGO) about the use of osteobiologics in anterior cervical discectomy and fusion (ACDF) for treating degenerative spine conditions. METHODS: The guideline development process was guided by AO Spine Knowledge Forum Degenerative (KF Degen) and followed the Guideline International Network McMaster Guideline Development Checklist. The process involved 73 participants with expertise in degenerative spine diseases and surgery from 22 countries. Fifteen systematic reviews were conducted addressing respective key topics and evidence was collected. The methodologist compiled the evidence into GRADE Evidence-to-Decision frameworks. Guideline panel members judged the outcomes and other criteria and made the final recommendations through consensus. RESULTS: Five conditional recommendations were created. A conditional recommendation is about the use of allograft, autograft or a cage with an osteobiologic in primary ACDF surgery. Other conditional recommendations are about the use of osteobiologic for single- or multi-level ACDF, and for hybrid construct surgery. It is suggested that surgeons use other osteobiologics rather than human bone morphogenetic protein-2 (BMP-2) in common clinical situations. Surgeons are recommended to choose 1 graft over another or 1 osteobiologic over another primarily based on clinical situation, and the costs and availability of the materials. CONCLUSION: This AOGO guideline is the first to provide recommendations for the use of osteobiologics in ACDF. Despite the comprehensive searches for evidence, there were few studies completed with small sample sizes and primarily as case series with inherent risks of bias. Therefore, high-quality clinical evidence is demanded to improve the guideline.

16.
Global Spine J ; 14(2_suppl): 78S-85S, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38421333

RESUMEN

STUDY DESIGN: Systematic literature review. OBJECTIVES: To analyze the evidence available reporting complications in single or two-level anterior cervical discectomy and fusion (ACDF) using a demineralized bone matrix (DBM), hydroxyapatite (HA), or beta-tricalcium phosphate (ß-TCP). METHODS: A systematic review of the literature using PubMed, EMBASE, Cochrane Library, and ClinicalTrials.gov databases was performed in August 2020 to identify studies reporting complications in one or two-level ACDF surgery using DBM, HA, or ß-TCP. The study was reported following the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines. RESULTS: A total of 1857 patients were included, 981 male and 876 female, across 17 articles; 5 prospective, and 12 retrospectives. We noted heterogeneity among the included studies concerning the study design and combination of graft materials utilized in them. However, we noted a higher incidence of adjacent segment disease (17.7%) and pseudoarthrosis (9.3%) in fusion constructs using DBM. Studies using ß-TCP reported a higher incidence of pseudoarthrosis (28.2%) and implant failures (17.9%). CONCLUSIONS: Degenerative cervical conditions treated with one or two-level ACDF surgery using DBM, HA, or ß-TCP with or without cervical plating are associated with complications such as adjacent segment disease, dysphagia, and pseudarthrosis. However, consequent to the study designs and clinical heterogeneity of the studies, it is not possible to correlate these complications accurately with any specific graft material employed. Further well-designed prospective studies are needed to correctly know the related morbidity of each graft used for achieving fusion in ACDF.

17.
Global Spine J ; 14(2_suppl): 141S-162S, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38421332

RESUMEN

STUDY DESIGN: Systematic review. OBJECTIVES: The study's primary objective was to determine how osteobiologic choice affects fusion rates in patients undergoing anterior cervical discectomy and fusion (ACDF). The study's secondary objectives were to 1) determine the optimal timing of fusion assessment following ACDF and 2) determine if osteobiologic type affects the timing and optimal modality of fusion assessment. METHODS: A systematic search of PubMed/MEDLINE was conducted for literature published from 2000 through October 2020 comparing anterior fusion in the cervical spine with various osteobiologics. Both comparative studies and case series of ≥10 patients were included. RESULTS: A total of 74 studies met the inclusion criteria. Seventeen studies evaluated the efficacy of autograft on fusion outcomes, and 23 studies assessed the efficacy of allograft on fusion outcomes. 3 studies evaluated the efficacy of demineralized bone matrix, and seven assessed the efficacy of rhBMP-2 on fusion outcomes. Other limited studies evaluated the efficacy of ceramics and bioactive glasses on fusion outcomes, and 4 assessed the efficacy of stem cell products. Most studies utilized dynamic radiographs for the assessment of fusion. Overall, there was a general lack of supportive data to determine the optimal timing of fusion assessment meaningfully or if osteobiologic type influenced fusion timing. CONCLUSIONS: Achieving fusion following ACDF appears to remain an intricate interplay between host biology and various surgical factors, including the selection of osteobiologics. While alternative osteobiologics to autograft exist and may produce acceptable fusion rates, limitations in study methodology prevent any definitive conclusions from existing literature.

18.
Global Spine J ; 14(2_suppl): 59S-69S, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36723507

RESUMEN

STUDY DESIGN: Network meta-analysis. OBJECTIVES: To compare the fusion outcome and complications of different 1 or 2-level anterior cervical decompression and fusion (ACDF) constructs performed with and without the application of autografts. METHODS: We performed an independent and duplicate search in electronic databases including PubMed, Embase, Web of Science, Cochrane, and Scopus for relevant articles published between 2000 and 2020. We included comparative studies reporting fusion rate and complications with and without the use of autografts in ACDF across 5 different fusion constructs. A network meta-analysis was performed in Stata, categorized based on the type of fusion constructs utilized. Fusion constructs were ranked based on p-score approach and surface under cumulative ranking curve (SUCRA) scores. The confidence of results from the analysis was appraised with Cochrane's CINeMA approach. RESULTS: A total of 2216 patients from 22-studies including 6 Randomized Controlled Trials (RCTs) and 16 non-RCTs were included in network analysis. The mean age of included patients was 49.3 (±3.62) years. Based on our meta-analysis, we could conclude that use of autograft in 1- or 2-level ACDF did not affect the fusion and mechanical implant-related complications. The final fusion and mechanical complication rates were also not significantly different across the different fusion constructs. The use of plated constructs was associated with a significant increase in post-ACDF dysphagia rates [OR 3.42; 95%CI (.01,2.45)], as compared to stand-alone constructs analysed. CONCLUSION: The choice of fusion constructs and use of autografts does not significantly affect the fusion and overall complication rates following 1 or 2-level ACDF surgery.

20.
Aquat Toxicol ; 265: 106743, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37931377

RESUMEN

Plastics, particularly microplastics (MPs) and nanoplastics (NPs), have been regarded as pollutants of emerging concern due to their effects on organisms and ecosystems, especially considering marine environments. However, in terms of NPs, there is still a knowledge gap regarding the effects of size and polymer on marine invertebrates, such as benthic organisms. Therefore, this study aimed to understand, regarding behavioural, physiological, and biochemical endpoints (neurotransmission, energy metabolism, antioxidant status, and oxidative damage), the effects of 50 nm waterborne polymethylmethacrylate (PMMA) NPs (0.5 to 500 µg/L) on the marine benthic polychaete Hediste diversicolor, a key species in estuarine and coastal ecosystems. Results demonstrated that worms exposed to PMMA NPs had a shorter burrowing time than control organisms. Nevertheless, worms exposed to PMMA NPs (0.5 and 500 µg/L) decreased cholinesterase activity. Energy metabolism was decreased at 50 and 500 µg/L, and glycogen content decreased at all concentrations of PMMA NPs. Enzymes related to the antioxidant defence system (superoxide dismutase and glutathione peroxidase) displayed increased activities in H. diversicolor specimens exposed to concentrations between 0.5 and 500 µg/L, which led to no damage at the cell membrane and protein levels. In this study, polychaetes also displayed a lower regenerative capacity when exposed to PMMA NPs. Overall, the data obtained in this study emphasize the potential consequences of PMMA NPs to benthic worms, particularly between 0.5 and 50 µg/L, with polychaetes exposed to 50 µg/L being the most impacted by the analysed NPs. However, since sediments are considered to be sinks and sources of plastics, further studies are needed to better understand the impacts of different sizes and polymers on marine organisms, particularly benthic species.


Asunto(s)
Poliquetos , Contaminantes Químicos del Agua , Animales , Antioxidantes/metabolismo , Polimetil Metacrilato/toxicidad , Polimetil Metacrilato/metabolismo , Microplásticos/metabolismo , Plásticos , Ecosistema , Contaminantes Químicos del Agua/toxicidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA