Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 119
Filtrar
1.
ACS Appl Mater Interfaces ; 16(28): 36715-36726, 2024 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-38978456

RESUMEN

Eu3+-induced polystyrene-co-poly(acrylic acid) aggregates (EIPAs) were synthesized using a self-assembly approach, and their structures and photophysical characteristics were examined to achieve effective monochromatic red emission in polymer light-emitting diodes (PLEDs). By adjusting the monomer ratio in RAFT polymerization, the size of Eu3+-induced block copolymer nanoaggregates can be regulated, thereby modulating the luminescence intensity. High-performance bilayer polymer light-emitting devices were fabricated using poly(9,9-dioctylfluorene) (PFO) and 2-(tert-butylphenyl)-5-biphenylyl-1,3,4-oxadiazole (PBD) as the host matrix, with EIPAs as the guest dopant. The devices exhibited narrow red emission at 615 nm with a full width at half-maximum (fwhm) of 15 nm across doping concentrations of 1, 3, 5, and 10 wt %. At a doping concentration of 3 wt %, the device achieved a maximum brightness of 1864.48 cd/m2 at 193.82 mA/cm2 and an external quantum efficiency of 3.20% at a current density of 3.5 mA/cm2. These results indicate that incorporating polystyrene-co-poly(acrylic acid) with Eu3+ complexes enhances the excitation and emission intensity, as well as the structural stability of the emitting layer in PLEDs, thereby improving the device performance.

2.
Nanoscale ; 16(26): 12510-12522, 2024 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-38874593

RESUMEN

Titanium-based orthopedic implants are gaining popularity in recent years due to their excellent biocompatibility, superior corrosion resistance and lightweight properties. However, these implants often fail to perform effectively due to poor osseointegration. Nanosurface modification approaches may help to resolve this problem. In this work, TiO2 nanotube (NT) arrays were fabricated on commercially available pure titanium (Ti) surfaces by anodization and annealing. Then, zinc (Zn) and strontium (Sr), important for cell signaling, were doped on the NT surface by hydrothermal treatment. This very simple method of Zn and Sr doping takes less time and energy compared to other complicated techniques. Different surface characterization tools such as scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), energy-dispersive X-ray spectroscopy (EDS), static water contact angle, X-ray diffraction (XRD) and nanoindentation techniques were used to evaluate the modified surfaces. Then, adipose derived stem cells (ADSCs) were cultured with the surfaces to evaluate cell adhesion, proliferation, and growth on the surfaces. After that, the cells were differentiated towards osteogenic lineage to evaluate alkaline phosphatase (ALP) activity, osteocalcin expression, and calcium phosphate mineralization. Results indicate that NT surfaces doped with Zn and Sr had significantly enhanced ADSC adhesion, proliferation, growth, and osteogenic differentiation compared to an unmodified surface, thus confirming the enhanced performance of these surfaces.


Asunto(s)
Proliferación Celular , Nanotubos , Osteogénesis , Estroncio , Propiedades de Superficie , Titanio , Zinc , Titanio/química , Titanio/farmacología , Estroncio/química , Estroncio/farmacología , Nanotubos/química , Zinc/química , Zinc/farmacología , Osteogénesis/efectos de los fármacos , Proliferación Celular/efectos de los fármacos , Adhesión Celular/efectos de los fármacos , Diferenciación Celular/efectos de los fármacos , Humanos , Fosfatasa Alcalina/metabolismo , Células Madre/citología , Células Madre/metabolismo , Células Madre/efectos de los fármacos , Materiales Biocompatibles/química , Materiales Biocompatibles/farmacología , Células Cultivadas
3.
RSC Adv ; 14(11): 7440-7458, 2024 Feb 29.
Artículo en Inglés | MEDLINE | ID: mdl-38433935

RESUMEN

Polymeric biomaterials are a widely used class of materials due to their versatile properties. However, as with all other types of materials used for biomaterials, polymers also have to interact with blood. When blood comes into contact with any foreign body, it initiates a cascade which leads to platelet activation and blood coagulation. The implant surface also has to encounter a thromboinflammatory response which makes the implant integrity vulnerable, this leads to blood coagulation on the implant and obstructs it from performing its function. Hence, the surface plays a pivotal role in the design and application of biomaterials. In particular, the surface properties of biomaterials are responsible for biocompatibility with biological systems and hemocompatibility. This review provides a report on recent advances in the field of surface modification approaches for improved hemocompatibility. We focus on the surface properties of polysaccharides, proteins, and synthetic polymers. The blood coagulation cascade has been discussed and blood - material surface interactions have also been explained. The interactions of blood proteins and cells with polymeric material surfaces have been discussed. Moreover, the benefits as well as drawbacks of blood coagulation on the implant surface for wound healing purposes have also been studied. Surface modifications implemented by other researchers to enhance as well as prevent blood coagulation have also been analyzed.

4.
Materials (Basel) ; 16(21)2023 Oct 24.
Artículo en Inglés | MEDLINE | ID: mdl-37959431

RESUMEN

Microbial colonization in veterinary stents poses a significant and concerning issue in veterinary medicine. Over time, these pathogens, particularly bacteria, can colonize the stent surfaces, leading to various complications. Two weeks following the stent insertion procedure, the colonization becomes observable, with the aggressiveness of bacterial growth directly correlating with the duration of stent placement. Such microbial colonization can result in infections and inflammations, compromising the stent's efficacy and, subsequently, the animal patient's overall well-being. Managing and mitigating the impact of these pathogens on veterinary stents is a crucial challenge that veterinarians and researchers are actively addressing to ensure the successful treatment and recovery of their animal patients. In addition, irritation of the tissue in the form of an inserted stent can lead to overgrowth of granulation tissue, leading to the closure of the stent lumen, as is most often the case in the trachea. Such serious complications after stent placement require improvements in the procedures used to date. In this review, antibacterial or antibiofilm strategies for several stents used in veterinary medicine have been discussed based on the current literature and the perspectives have been drawn. Various coating strategies such as coating with hydrogel, antibiotic, or other antimicrobial agents have been reviewed.

5.
J Funct Biomater ; 14(11)2023 Nov 18.
Artículo en Inglés | MEDLINE | ID: mdl-37998123

RESUMEN

Bacterial infections are a common mode of failure for medical implants. This study aims to develop antibacterial polyelectrolyte multilayer (PEM) coatings that contain a plant-derived condensed tannin polymer (Tanfloc, TAN) with inherent antimicrobial activity. Tanfloc is amphoteric, and herein we show that it can be used as either a polyanion or a polycation in PEMs, thereby expanding the possibility of its use in PEM coatings. PEMs are ordinarily formed using a polycation and a polyanion, in which the functional (ionic) groups of the two polymers are complexed to each other. However, using the amphoteric polymer Tanfloc with weakly basic amine and weakly acidic catechol and pyrogallol groups enables PEM formation using only one or the other of its functional groups, leaving the other functional group available to impart antibacterial activity. This work demonstrates Tanfloc-containing PEMs using multiple counter-polyelectrolytes including three polyanionic glycosaminoglycans of varying charge density, and the polycations N,N,N-trimethyl chitosan and polyethyleneimine. The layer-by-layer (LbL) assembly of PEMs was monitored using in situ Fourier-transform surface plasmon resonance (FT-SPR), confirming a stable LbL assembly. X-ray photoelectron spectroscopy (XPS) was used to evaluate surface chemistry, and atomic force microscopy (AFM) was used to determine the surface roughness. The LDH release levels from cells cultured on the Tanfloc-containing PEMs were not statistically different from those on the negative control (p > 0.05), confirming their non-cytotoxicity, while exhibiting remarkable antiadhesive and bactericidal properties against Pseudomonas aeruginosa (P. aeruginosa) and Staphylococcus aureus (S. aureus), respectively. The antibacterial effects were attributed to electrostatic interactions and Tanfloc's polyphenolic nature. This work underscores the potential of Tanfloc as a versatile biomaterial for combating infections on surfaces.

6.
J Funct Biomater ; 14(8)2023 Aug 04.
Artículo en Inglés | MEDLINE | ID: mdl-37623658

RESUMEN

Titanium and its alloys are commonly used to fabricate orthopedic implants due to their excellent mechanical properties, corrosion resistance, and biocompatibility. In recent years, orthopedic implant surgeries have considerably increased. This has also resulted in an increase in infection-associated revision surgeries for these implants. To combat this, various approaches are being investigated in the literature. One of the approaches is modifying the surface topography of implants and creating surfaces that are not only antifouling but also encourage osteointegration. Titania nanotube surfaces have demonstrated a moderate decrease in bacterial adhesion while encouraging mesenchymal stem cell adhesion, proliferation, and differentiation, and hence were used in this study. In this work, titania nanotube surfaces were fabricated using a simple anodization technique. These surfaces were further modified with copper using a physical vapor deposition technique, since copper is known to be potent against bacteria once in contact. In this study, scanning electron microscopy was used to evaluate surface topography; energy-dispersive X-ray spectroscopy and X-ray photoelectron spectroscopy were used to evaluate surface chemistry; contact angle goniometry was used to evaluate surface wettability; and X-ray diffraction was used to evaluate surface crystallinity. Antifouling behavior against a gram-positive and a gram-negative bacterium was also investigated. The results indicate that copper-modified titania nanotube surfaces display enhanced antifouling behavior when compared to other surfaces, and this may be a potential way to prevent infection in orthopedic implants.

7.
Nanomaterials (Basel) ; 13(10)2023 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-37242024

RESUMEN

Titanium (Ti) is a popular biomaterial for orthopedic implant applications due to its superior mechanical properties such as corrosion resistance and low modulus of elasticity. However, around 10% of these implants fail annually due to bacterial infection and poor osseointegration, resulting in severe pain and suffering for the patients. To improve their performance, nanoscale surface modification approaches and doping of trace elements on the surfaces can be utilized which may help in improving cell adhesion for better osseointegration while reducing bacterial infection. In this work, at first, titania (TiO2) nanotube arrays (NT) were fabricated on commercially available pure Ti surfaces via anodization. Then zinc (Zn) doping was conducted following two distinct methods: hydrothermal and alkaline heat treatment. Scanning electron microscopic (SEM) images of the prepared surfaces revealed unique surface morphologies, while energy dispersive X-ray spectroscopy (EDS) revealed Zn distribution on the surfaces. Contact angle measurements indicated that NT surfaces were superhydrophilic. X-ray photoelectron spectroscopy (XPS) provided the relative amount of Zn on the surfaces and indicated that hydrothermally treated surfaces had more Zn compared to the alkaline heat-treated surfaces. X-ray crystallography (XRD) and nanoindentation techniques provided the crystal structure and mechanical properties of the surfaces. While testing with adipose-derived stem cells (ADSC), the surfaces showed no apparent cytotoxicity to the cells. Finally, bacteria adhesion and morphology were evaluated on the surfaces after 6 h and 24 h of incubation. From the results, it was confirmed that NT surfaces doped with Zn drastically reduced bacteria adhesion compared to the Ti control. Zn-doped NT surfaces thus offer a potential platform for orthopedic implant application.

8.
J Funct Biomater ; 14(5)2023 May 12.
Artículo en Inglés | MEDLINE | ID: mdl-37233379

RESUMEN

Heart failure is the leading cause of death in the US and worldwide. Despite modern therapy, challenges remain to rescue the damaged organ that contains cells with a very low proliferation rate after birth. Developments in tissue engineering and regeneration offer new tools to investigate the pathology of cardiac diseases and develop therapeutic strategies for heart failure patients. Tissue -engineered cardiac scaffolds should be designed to provide structural, biochemical, mechanical, and/or electrical properties similar to native myocardium tissues. This review primarily focuses on the mechanical behaviors of cardiac scaffolds and their significance in cardiac research. Specifically, we summarize the recent development of synthetic (including hydrogel) scaffolds that have achieved various types of mechanical behavior-nonlinear elasticity, anisotropy, and viscoelasticity-all of which are characteristic of the myocardium and heart valves. For each type of mechanical behavior, we review the current fabrication methods to enable the biomimetic mechanical behavior, the advantages and limitations of the existing scaffolds, and how the mechanical environment affects biological responses and/or treatment outcomes for cardiac diseases. Lastly, we discuss the remaining challenges in this field and suggestions for future directions to improve our understanding of mechanical control over cardiac function and inspire better regenerative therapies for myocardial restoration.

9.
Int J Biol Macromol ; 241: 124497, 2023 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-37080405

RESUMEN

Carboxymethylcellulose (CMC) and keratin nanoparticle (KNP) hydrogels were obtained, characterized, and applied as drug delivery systems (DDSs) for the first time. Lyophilized CMC/KNP mixtures containing 10, 25, and 50 wt% of KNPs were kept at 170 °C for 90 min to crosslink CMC chains through a solid-state reaction with the KNPs. The hydrogels were characterized by infrared spectroscopy, thermal analyses, X-ray diffraction, mechanical measurements, and scanning electron microscopy. The infrared spectra indicated the formation of ester and amide linkages between crosslinked CMC and KNPs. The elastic modulus of the hydrogel containing 10 wt% KNPs was 2-fold higher than that of the hydrogel containing 50 wt% KNPs. The mechanical properties influenced the hydrogel stability and water uptake. The anti-inflammatory prednisolone (PRED) drug was incorporated into the hydrogels, and the release mechanism was investigated. The hydrogels supported PRED release by drug desorption for approximately 360 h. A sustained release mechanism was achieved. The CMC/KNP and CMC/KNP/PRED hydrogels were cytocompatible toward mammalian cells. The CMC/KNP/PRED set imparted the highest cell viability after 7 days of incubation. This study showed a straightforward procedure to create DDSs (chemically crosslinked) based on polysaccharides and proteins for efficient PRED delivery.


Asunto(s)
Hidrogeles , Nanopartículas , Animales , Hidrogeles/química , Queratinas , Carboximetilcelulosa de Sodio/química , Prednisolona/farmacología , Antiinflamatorios , Mamíferos
10.
Materials (Basel) ; 16(5)2023 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-36903086

RESUMEN

This study aims to characterize a new Ti-25Ta-25Nb-5Sn alloy for biomedical application. Microstructure, phase formation, mechanical and corrosion properties, along with the cell culture study of the Ti-25Ta-25Nb alloy with Sn content 5 mass% are presented in this article. The experimental alloy was processed in an arc melting furnace, cold worked, and heat treated. For characterization, optical microscopy, X-ray diffraction, microhardness, and Young's modulus measurements were employed. Corrosion behavior was also evaluated using open-circuit potential (OCP) and potentiodynamic polarization. In vitro studies with human ADSCs were performed to investigate cell viability, adhesion, proliferation, and differentiation. Comparison among the mechanical properties observed in other metal alloy systems, including CP Ti, Ti-25Ta-25Nb, and Ti-25Ta-25-Nb-3Sn showed an increase in microhardness and a decrease in the Young's modulus when compared to CP Ti. The potentiodynamic polarization tests indicated that the corrosion resistance of the Ti-25Ta-25Nb-5Sn alloy was similar to CP Ti and the experiments in vitro demonstrated great interactions between the alloy surface and cells in terms of adhesion, proliferation, and differentiation. Therefore, this alloy presents potential for biomedical applications with properties required for good performance.

11.
ACS Appl Mater Interfaces ; 15(4): 5086-5098, 2023 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-36669233

RESUMEN

High-performance energy storage devices (HPEDs) play a critical role in the realization of clean energy and thus enable the overarching pursuit of nonpolluting, green technologies. Supercapacitors are one class of such lucrative HPEDs; however, a serious limiting factor of supercapacitor technology is its sub-par energy density. This report presents hitherto unchartered pathway of physical deformation, chemical dealloying, and microstructure engineering to produce ultrahigh-capacitance, energy-dense NiMn alloy electrodes. The activated electrode delivered an ultrahigh specific-capacitance of 2700 F/cm3 at 0.5 A/cm3. The symmetric device showcased an excellent energy density of 96.94 Wh/L and a remarkable cycle life of 95% retention after 10,000 cycles. Transmission electron microscopy and atom probe tomography studies revealed the evolution of a unique hierarchical microstructure comprising fine Ni/NiMnO3 nanoligaments within MnO2-rich nanoflakes. Theoretical analysis using density functional theory showed semimetallic nature of the nanoscaled oxygen-vacancy-rich NiMnO3 structure, highlighting enhanced carrier concentration and electronic conductivity of the active region. Furthermore, the geometrical model of NiMnO3 crystals revealed relatively large voids, likely providing channels for the ion intercalation/de-intercalation. The current processing approach is highly adaptable and can be applied to a wide range of material systems for designing highly efficient electrodes for energy-storage devices.

12.
Mater Today Nano ; 242023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38370345

RESUMEN

Protein crystals with sufficiently large solvent pores can non-covalently adsorb polymers in the pores. In principle, if these polymers contain cell adhesion ligands, the polymer-laden crystals could present ligands to cells with tunable adhesion strength. Moreover, porous protein crystals can store an internal ligand reservoir, so that the surface can be replenished. In this study, we demonstrate that poly(ethylene glycol) terminated with a cyclic cell adhesion ligand peptide (PEG-RGD) can be loaded into porous protein crystals by diffusion. Through atomic force microscopy (AFM), force-distance correlations of the mechanical interactions between activated AFM tips and protein crystals were precisely measured. The activation of AFM tips allows the tips to interact with PEG-RGD that was pre-loaded in the protein crystal nanopores, mimicking how a cell might attach to and pull on the ligand through integrin receptors. The AFM experiments also simultaneously reveal the detailed morphology of the buffer-immersed nanoporous protein crystal surface. We also show that porous protein crystals (without and with loaded PEG-RGD) serve as suitable substrates for attachment and spreading of adipose-derived stem cells. This strategy can be used to design surfaces that non-covalently present multiple different ligands to cells with tunable adhesive strength for each ligand, and with an internal reservoir to replenish the precisely defined crystalline surface.

13.
ACS Sustain Chem Eng ; 11(6): 2397-2403, 2023 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-38162324

RESUMEN

With the passage of the 2018 Farm Bill that removed hemp from the Controlled Substances Act altogether, production of hemp is experiencing a renaissance. Building on this revival and re-emergence of hemp, we designed and fabricated hemp-based sustainable and robust slippery surfaces by coating hemp paper with beeswax and subsequently infusing it with hemp oil. A wide variety of aqueous liquids and beverages easily slide on our hemp-based sustainable slippery surfaces, without leaving a trace. We also fabricated hemp-based sustainable slippery surfaces using different textured metals. Our hemp-based sustainable slippery metal surfaces display good icephobic and antithrombotic properties. With these attributes, we envision that our hemp-based sustainable slippery surfaces will pave the path to more safe, non-toxic, and biodegradable or recyclable slippery surfaces for applications in food packaging, anti-icing or de-icing coatings, and antithrombotic medical devices.

14.
Materials (Basel) ; 15(23)2022 Dec 03.
Artículo en Inglés | MEDLINE | ID: mdl-36500131

RESUMEN

The study of new metallic biomaterials for application in bone tissue repair has improved due to the increase in life expectancy and the aging of the world population. Titanium alloys are one of the main groups of biomaterials for these applications, and beta-type titanium alloys are more suitable for long-term bone implants. The objective of this work was to process and characterize a new Ti10Mo8Nb6Zr beta alloy. Alloy processing involves arc melting, heat treatment, and cold forging. The characterization techniques used in this study were X-ray fluorescence spectroscopy, X-ray diffraction, differential scanning calorimetry, optical microscopy, microhardness measurements, and pulse excitation technique. In vitro studies using adipose-derived stem cells (ADSC) were performed to evaluate the cytotoxicity and cell viability after 1, 4, and 7 days. The results showed that the main phase during the processing route was the beta phase. At the end of processing, the alloy showed beta phase, equiaxed grains with an average size of 228.7 µm, and low Young's modulus (83 GPa). In vitro studies revealed non-cytotoxicity and superior cell viability compared to CP Ti. The addition of zirconium led to a decrease in the beta-transus temperature and Young's modulus and improved the biocompatibility of the alloy. Therefore, the Ti10Mo8Nb6Zr alloy is a promising candidate for application in the biomedical field.

15.
Nanomaterials (Basel) ; 12(20)2022 Oct 14.
Artículo en Inglés | MEDLINE | ID: mdl-36296799

RESUMEN

In this work, a new photovoltaic device was prepared. The device uses titanium (Ti) foil/TiO2 nanotubes as the photoanode and multi-walled carbon nanotubes (MWCNTs) as a photosensitizer. Titanium dioxide nanotube arrays (TiO2-NTs) were prepared by one-step anodic oxidation. Cut-MWCNTs with a length of less than 100 nm were obtained by the mixed-acid oxidation of MWCNTs. The two materials were combined to form a TiO2-NTs@cut-MWCNT heterostructure by electrophoresis. TiO2-NTs@cut-MWCNTs were characterized by field-emission scanning electron microscopy (FESEM) and X-ray diffraction (XRD), which showed that the two materials were effectively combined. We fabricated the heterostructure into a photovoltaic device, showing an enhanced photocurrent response and an efficiency of 0.0138%, and explained this phenomenon by performing UV-vis absorption spectroscopy and electrochemical tests. It is hoped that this work can provide a reference value for the application of carbon nanotubes in photovoltaic devices.

16.
J Biomed Mater Res A ; 110(7): 1314-1328, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35188338

RESUMEN

Micro/nano scale surface modifications of titanium based orthopedic and cardiovascular implants has shown to augment biocompatibility. However, bacterial infection remains a serious concern for implant failure, aggravated by increasing antibiotic resistance and over usage of antibiotics. Bacteria cell adhesion on implant surface leads to colonization and biofilm formation resulting in morbidity and mortality. Hence, there is a need to develop new implant surfaces with high antibacterial properties. Recent developments have shown that superhydrophobic surfaces prevent protein and bacteria cell adhesion. In this study, a thermochemical treatment was used modify the surface properties for high efficacy antibacterial activity on titanium surface. The modification led to a micro-nano surface topography and upon modification with polyethylene glycol (PEG) and silane the surfaces were superhydrophilic and superhydrophobic, respectively. The modified surfaces were characterized for morphology, wettability, chemistry, corrosion resistance and surface charge. The antibacterial capability was characterized with Staphylococcus aureus and Escherichia coli by evaluating the bacteria cell inhibition, adhesion kinetics, and biofilm formation. The results indicated that the superhydrophobic micro-nano structured titanium surface reduced bacteria cell adhesion significantly (>90%) and prevented biofilm formation compared to the unmodified titanium surface after 24 h of incubation.


Asunto(s)
Antibacterianos , Titanio , Antibacterianos/química , Antibacterianos/farmacología , Adhesión Bacteriana , Escherichia coli , Staphylococcus aureus , Propiedades de Superficie , Titanio/química , Titanio/farmacología , Humectabilidad
17.
In Vitro Model ; 1(3): 241-247, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-37519331

RESUMEN

SARS-CoV-2 is a pandemic coronavirus that causes severe respiratory disease (COVID-19) in humans and is responsible for millions of deaths around the world since early 2020. The virus affects the human respiratory cells through its spike (S) proteins located at the outer shell. To monitor the rapid spreading of SARS-CoV-2 and to reduce the deaths from the COVID-19, early detection of SARS-CoV-2 is of utmost necessity. This report describes a flexible colorimetric biosensor capable of detecting the S protein of SARS-CoV-2. The colorimetric biosensor is made of polyurethane (PU)-polydiacetylene (PDA) nanofiber composite that was chemically functionalized to create a binding site for the receptor molecule-nucleocapsid antibody (anti-N) protein of SARS-CoV-2. After the anti-N protein conjugation to the functionalized PDA fibers, the PU-PDA-NHS-anti fiber was able to detect the S protein of SARS-CoV-2 at room temperature via a colorimetric transition from blue to red. The PU-PDA nanofiber-based biosensors are flexible and lightweight and do not require a power supply such as a battery when the colorimetric detection to S protein occurs, suggesting a sensing platform of wearable devices and personal protective equipment such as face masks and medical gowns for real-time monitoring of virus contraction and contamination. The wearable biosensors could significantly power mass surveillance technologies to fight against the COVID-19 pandemic. Supplementary Information: The online version contains supplementary material available at 10.1007/s44164-022-00022-z.

18.
Bioengineering (Basel) ; 10(1)2022 Dec 29.
Artículo en Inglés | MEDLINE | ID: mdl-36671615

RESUMEN

Blood-contacting titanium-based implants such as endovascular stents and heart valve casings are prone to blood clotting due to improper interactions at the surface level. In complement, the current clinical demand for cardiovascular implants is at a new apex. Hence, there is a crucial necessity to fabricate an implant with optimal mechanical properties and improved blood compatibility, while simultaneously interacting differentially with cells and other microbial agents. The present study intends to develop a superhydrophobic implant surface with the novel micro-nano topography, developed using a facile thermochemical process. The surface topography, apparent contact angle, and crystal structure are characterized on different surfaces. The hemo/blood compatibility on different surfaces is assessed by evaluating hemolysis, fibrinogen adsorption, cell adhesion and identification, thrombin generation, complement activation, and whole blood clotting kinetics. The results indicate that the super-hemo/hydrophobic micro-nano titanium surface improved hemocompatibility by significantly reducing fibrinogen adsorption, platelet adhesion, and leukocyte adhesion. Thus, the developed surface has high potential to be used as an implant. Further studies are directed towards analyzing the mechanisms causing the improved hemocompatibility of micro/nano surface features under dynamic in vitro and in vivo conditions.

19.
Nanomaterials (Basel) ; 11(12)2021 Dec 03.
Artículo en Inglés | MEDLINE | ID: mdl-34947632

RESUMEN

In this work, titania (TiO2) nanoparticles modified by Eu(TTA)3Phen complexes (ETP) were prepared by a simple solvothermal method developing a fluorescence Mn7+ pollutant sensing system. The characterization results indicate that the ETP cause structural deformation and redshifts of the UV-visible light absorptions of host TiO2 nanoparticles. The ETP also reduce the crystallinity and crystallite size of TiO2 nanoparticles. Compared with TiO2 nanoparticles modified with Eu3+ (TiO2-Eu3+), TiO2 nanoparticles modified with ETP (TiO2-ETP) exhibit significantly stronger photoluminescence under the excitation of 394 nm. Under UV excitation, TiO2-ETP nanoparticles showed blue and red emission corresponding to TiO2 and Eu3+. In addition, as the concentration of ETP in TiO2 nanoparticles increases, the PL intensity at 612 nm also increases. When ETP-modified TiO2 nanoparticles are added to an aqueous solution containing Mn7+, the fluorescence intensity of both TiO2 and ETP decreases. The evolution of the fluorescence intensity ratio (I1/I2) of TiO2 and ETP is linearly related to the concentration of Mn7+. The sensitivity of fluorescence intensity to Mn7+ concentration enables the design of dual fluorescence ratio solid particle sensors. The method proposed here is simple, accurate, efficient, and not affected by the environmental conditions.

20.
Appl Surf Sci ; 5702021 Dec 30.
Artículo en Inglés | MEDLINE | ID: mdl-34594060

RESUMEN

Titanium and its alloys are the most used biomaterials for orthopedic and dental applications. However, up to 10% of these medical devices still fail, mostly due to implant loosening and suboptimal integration at the implant site. The biomaterial surface plays a critical role in promoting osseointegration, which can reduce the risk of device failure. In this study, we propose a novel surface modification on titanium to improve osteogenic differentiation by depositing manganese-containing bioactive glass (BG) on TiO2 nanotube arrays. The surfaces were characterized by scanning electron microscopy, energy dispersive X-ray spectrometer, contact angle goniometry, and X-ray photoelectron spectroscopy. Cell toxicity, viability, adhesion, and proliferation of adipose-derived stem cells on the surfaces were investigated up to 7 days. To evaluate the osteogenic properties of the surfaces, alkaline phosphatase activity, total protein, osteocalcin expression, and calcium deposition were quantified up to 28 days. The results indicate that TiO2 nanotube arrays modified with BG promote cell growth and induce increased osteocalcin and calcium contents when compared to unmodified TiO2 nanotube arrays. The deposition of manganese-containing bioactive glass onto TiO2 nanotubes demonstrates the ability to enhance osteogenic activity on titanium, showing great potential for use in orthopedic and dental implants.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA