Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
JACC Cardiovasc Interv ; 6(5): 523-32, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23702016

RESUMEN

OBJECTIVES: This study sought to assess the vascular response of overlapping Absorb stents compared with overlapping newer-generation everolimus-eluting metallic platform stents (Xience V [XV]) in a porcine coronary artery model. BACKGROUND: The everolimus-eluting bioresorbable vascular scaffold (Absorb) is a novel approach to treating coronary lesions. A persistent inflammatory response, fibrin deposition, and delayed endothelialization have been reported with overlapping first-generation drug-eluting stents. METHODS: Forty-one overlapping Absorb and overlapping Xience V (XV) devices (3.0 × 12 mm) were implanted in the main coronary arteries of 17 nonatherosclerotic pigs with 10% overstretch. Implanted coronary arteries were evaluated by optical coherence tomography (OCT) at 28 days (Absorb n = 11, XV n = 7) and 90 days (Absorb n = 11, XV n = 8), with immediate histological evaluation following euthanasia at the same time points. One animal from each time point was evaluated with scanning electron microscopy alone. A total of 1,407 cross sections were analyzed by OCT and 148 cross sections analyzed histologically. RESULTS: At 28 days in the overlap, OCT analyses indicated 80.1% of Absorb struts and 99.4% of XV struts to be covered (p < 0.0001), corresponding to histological observations of struts with cellular coverage of 75.4% and 99.6%, respectively (p < 0.001). Uncovered struts were almost exclusively related to the presence of "stacked" Absorb struts, that is, with a direct overlay configuration. At 90 days, overlapping Absorb and overlapping XV struts demonstrated >99% strut coverage by OCT and histology, with no evidence of a significant inflammatory process, and comparable % volume obstructions. CONCLUSIONS: In porcine coronary arteries implanted with overlapping Absorb or overlapping XV struts, strut coverage is delayed at 28 days in overlapping Absorb, dependent on the overlay configuration of the thicker Absorb struts. At 90 days, both overlapping Absorb and overlapping XV have comparable strut coverage. The implications of increased strut thickness may have important clinical and design considerations for bioresorbable platforms.


Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares/administración & dosificación , Vasos Coronarios/patología , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Sirolimus/análogos & derivados , Tomografía de Coherencia Óptica , Animales , Everolimus , Modelos Animales , Intervención Coronaria Percutánea/efectos adversos , Diseño de Prótesis , Sirolimus/administración & dosificación , Porcinos , Factores de Tiempo
2.
Int J Cardiovasc Imaging ; 28(3): 499-511, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21503708

RESUMEN

To quantify with in vivo OCT and histology, the device/vessel interaction after implantation of the bioresorbable vascular scaffold (BVS). We evaluated the area and thickness of the strut voids previously occupied by the polymeric struts, and the neointimal hyperplasia (NIH) area covering the endoluminal surface of the strut voids (NIH(EV)), as well as the NIH area occupying the space between the strut voids (NIH(BV)), in healthy porcine coronary arteries at 2, 3 and 4 years after implantation of the device. Twenty-two polymeric BVS were implanted in the coronary arteries of 11 healthy Yucatan minipigs that underwent OCT at 2, 3 and 4 years after implantation, immediately followed by euthanasia. The areas and thicknesses of 60 corresponding strut voids previously occupied by the polymeric struts and the size of 60 corresponding NIH(EV) and 49 NIH(BV) were evaluated with both OCT and histology by 2 independent observers, using a single quantitative analysis software for both techniques. At 3 and 4 years after implantation, the strut voids were no longer detectable by OCT or histology due to complete polymer resorption. However, analysis performed at 2 years still provided clear delineation of these structures, by both techniques. The median [ranges] areas of these strut voids were 0.04 [0.03-0.16] and 0.02 [0.01-0.07] mm(2) by histology and OCT, respectively. The mean (±SD) thickness by histology and OCT was 220 ± 40 and 120 ± 20 µm, respectively. The median [ranges] NIH(EV) by histology and OCT was 0.07 [0.04-0.20] and 0.03 [0.01-0.08] mm(2), while the mean (±SD) NIH(BV) by histology and OCT was 0.13 ± 0.07 and 0.10 ± 0.06 mm(2). Our study indicates that in vivo OCT of the BVS provides correlated measurements of the same order of magnitude as histomorphometry, and is reproducible for the evaluation of certain vascular and device-related characteristics. However, histology systematically gives larger values for all the measured structures compared to OCT, at 2 years post implantation.


Asunto(s)
Implantes Absorbibles , Angioplastia Coronaria con Balón/instrumentación , Fármacos Cardiovasculares/administración & dosificación , Vasos Coronarios/efectos de los fármacos , Sirolimus/análogos & derivados , Andamios del Tejido , Tomografía de Coherencia Óptica , Angioplastia Coronaria con Balón/efectos adversos , Animales , Vasos Coronarios/patología , Everolimus , Estudios de Factibilidad , Hiperplasia , Modelos Animales , Neointima , Proyectos Piloto , Sirolimus/administración & dosificación , Porcinos , Porcinos Enanos , Factores de Tiempo
3.
Circulation ; 122(22): 2288-300, 2010 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-20975003

RESUMEN

BACKGROUND: With the use of optical coherence tomography (OCT), alterations of the reflectance characteristics of everolimus-eluting bioresorbable vascular scaffold (BVS) struts have been reported in humans. In the absence of histology, the interpretation of the appearances of the struts by OCT remains speculative. We therefore report OCT findings with corresponding histology in the porcine coronary artery model immediately after and at 28 days and 2, 3, and 4 years after BVS implantation. METHODS AND RESULTS: Thirty-five polymeric BVS (3.0×12.0 mm) were singly implanted in the main coronary arteries of 17 pigs that underwent OCT and were then euthanized immediately (n=2), at 28 days (n=2), at 2 years (n=3), at 3 years (n=5), or at 4 years (n=5) after implantation. All BVS-implanted arteries in these animals were evaluated by histology except for 5 arteries examined at 2 years with gel permeation chromatography to assess the biodegradation of the polymeric device. Fourteen arteries with BVS from an additional 6 pigs were examined by gel permeation chromatography at 1 (n=1), 1.5 (n=2), and 3 (n=2) years. Corresponding OCT and histology images were selected with the distal and proximal radiopaque markers used as landmarks. At 28 days, by OCT, 82% of struts showed sharply defined, bright reflection borders, best described as a box-shaped appearance. Histologically, all struts appeared intact with no evidence of resorption. At 2 years, by OCT, 60±20 struts were discernible per BVS with 80.4% of the strut sites as a box-shaped appearance. Despite their defined appearance by OCT, by histology, these structures appeared to be composed of proteoglycan, with polymeric material being at such low level as to be no longer quantifiable by chromatography. At 3 years, by OCT, recognizable struts decreased to 28±9 struts per BVS: 43.7% showed dissolved black box; 34.8%, dissolved bright box; 16.1%, open box; and 5.4%, preserved box appearance. Histology shows that connective tissue cells within a proteoglycan-rich matrix replaced the areas previously occupied by the polymeric struts and coalesced into the arterial wall. At 4 years, by OCT, 10±6 struts were recognizable as either dissolved black or dissolved bright box. In histology, these struts are minimally discernible as foci of low-cellular-density connective tissue. Relative to the prediction of histological type by OCT appearance, the preserved box appearance of OCT corresponds well with 2-year histology (86.4%), whereas the dissolved bright and black box appearances correspond to 3-year histology (88.0% and 90.7%, respectively). Struts indiscernible by OCT correspond to the integrated strut footprints seen at 4 years (100%). CONCLUSIONS: Struts that are still discernible by OCT at 2 years are compatible with largely bioresorbed struts, as demonstrated by histological and gel permeation chromatography analysis. At 3 and 4 years, both OCT and histology confirm complete integration of the struts into the arterial wall.


Asunto(s)
Implantes Absorbibles , Vasos Coronarios/patología , Stents Liberadores de Fármacos , Sirolimus/análogos & derivados , Andamios del Tejido , Tomografía de Coherencia Óptica/métodos , Animales , Everolimus , Humanos , Modelos Animales , Polímeros , Proteoglicanos , Estudios Retrospectivos , Porcinos , Porcinos Enanos , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA