1.
Magn Reson Med ; 2024 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-39188123

RESUMEN

PURPOSE: To provide a navigator-based run-time motion and first-order field correction for three-dimensional human brain imaging with high precision, minimal calibration and acquisition, and fast processing. METHODS: A complex-valued linear perturbation model with feedback control is extended to estimate and correct for gradient shim fields using orbital navigators (2.3 ms). Two approaches for sensitizing the model to gradient fields are presented, one based on finite differences with three additional navigators, and another projection-based approximation requiring no additional navigators. A mechanism for noise decorrelation of the matrix and the data is proposed and evaluated to reduce unwanted parameter biases. RESULTS: The rigid motion and first-order field control achieves robust motion and gradient shim corrections improving image quality in a series of phantom and in vivo experiments with varying field conditions. In phantom scans, magnet drifts, forced gradient field perturbations and field distortions from shifts of a second bottle phantom are successfully corrected. Field estimates of the magnet drifts are in good agreement with concurrent field probe measurements. For in vivo scans, the proposed method mitigates field variations from torso motions while being robust to head motion. In vivo gradient field precisions were 30 nT / m $$ 30\;\mathrm{nT}/\mathrm{m} $$ along with single-digit micrometer and millidegree rigid precisions. CONCLUSION: The navigator-based method achieves accurate, high-precision run-time motion and field corrections with low sequence impact and calibration requirements.

2.
Alzheimers Dement (Amst) ; 16(2): e12587, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38690510

RESUMEN

Gamma-hydroxy-butyric acid (GABA) and glutamate are neurotransmitters with essential importance for cognitive processing. Here, we investigate relationships between GABA, glutamate, and brain ß-amyloid (Aß) burden before clinical manifestation of Alzheimer's disease (AD). Thirty cognitively healthy adults (age 69.9 ± 6 years) received high-resolution atlas-based 1H-magnetic resonance spectroscopic imaging (MRSI) at ultra-high magnetic field strength of 7 Tesla for gray matter-specific assessment of GABA and glutamate. We assessed Aß burden with positron emission tomography and risk factors for AD. Higher gray matter GABA and glutamate related to higher Aß-burden (ß = 0.60, p < 0.05; ß = 0.64, p < 0.02), with positive effect modification by apolipoprotein-E-epsilon-4-allele (APOE4) (p = 0.01-0.03). GABA and glutamate negatively related to longitudinal change in verbal episodic memory performance (ß = -0.48; p = 0.02; ß = -0.50; p = 0.01). In vivo measures of GABA and glutamate reflect early AD pathology at old age, in an APOE4-dependent manner. GABA and glutamate may represent promising biomarkers and potential targets for early therapeutic intervention and prevention. Highlights: Gray matter-specific metabolic imaging with high-resolution atlas-based MRSI at 7 Tesla.Higher GABA and glutamate relate to ß-amyloid burden, in an APOE4-dependent manner.Gray matter GABA and glutamate identify older adults with high risk of future AD.GABA and glutamate might reflect altered synaptic and neuronal activity at early AD.

3.
Magn Reson Med ; 92(2): 556-572, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38441339

RESUMEN

PURPOSE: To evaluate the utility of up to second-order motion-compensated diffusion encoding in multi-shot human brain acquisitions. METHODS: Experiments were performed with high-performance gradients using three forms of diffusion encoding motion-compensated through different orders: conventional zeroth-order-compensated pulsed gradients (PG), first-order-compensated gradients (MC1), and second-order-compensated gradients (MC2). Single-shot acquisitions were conducted to correlate the order of motion compensation with resultant phase variability. Then, multi-shot acquisitions were performed at varying interleaving factors. Multi-shot images were reconstructed using three levels of shot-to-shot phase correction: no correction, channel-wise phase correction based on FID navigation, and correction based on explicit phase mapping (MUSE). RESULTS: In single-shot acquisitions, MC2 diffusion encoding most effectively suppressed phase variability and sensitivity to brain pulsation, yielding residual variations of about 10° and of low spatial order. Consequently, multi-shot MC2 images were largely satisfactory without phase correction and consistently improved with the navigator correction, which yielded repeatable high-quality images; contrarily, PG and MC1 images were inadequately corrected using the navigator approach. With respect to MUSE reconstructions, the MC2 navigator-corrected images were in close agreement for a standard interleaving factor and considerably more reliable for higher interleaving factors, for which MUSE images were corrupted. Finally, owing to the advanced gradient hardware, the relative SNR penalty of motion-compensated diffusion sensitization was substantially more tolerable than that faced previously. CONCLUSION: Second-order motion-compensated diffusion encoding mitigates and simplifies shot-to-shot phase variability in the human brain, rendering the multi-shot acquisition strategy an effective means to circumvent limitations of retrospective phase correction methods.


Asunto(s)
Encéfalo , Procesamiento de Imagen Asistido por Computador , Movimiento (Física) , Humanos , Encéfalo/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Imagen de Difusión por Resonancia Magnética , Algoritmos , Artefactos
4.
Magn Reson Med ; 92(1): 406-415, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38411281

RESUMEN

PURPOSE: To utilize the transmit radiofrequency (RF) field in MRI as a power source, near or within the field of view but without affecting image quality or safety. METHODS: Power harvesting is performed by RF induction in a resonant coil. Resulting RF field distortion in the subject is canceled by a selective shield that couples to the harvester while being transparent to the RF transmitter. Such shielding is designed with the help of electromagnetic simulation. A shielded harvester of 3 cm diameter is implemented, assessed on the bench, and tested in a 3T MRI system, recording power yield during typical scans. RESULTS: The concept of selective shielding is confirmed by simulation. Bench tests show effective power harvesting in the presence of the shield. In the MRI system, it is confirmed that selective shielding virtually eliminates RF perturbation. In scans with the harvester immediately adjacent to a phantom, up to 100 mW of average power are harvested without affecting image quality. CONCLUSION: Selective shielding enables stealthy RF harvesting which can be used to supply wireless power to on-body devices during MRI.


Asunto(s)
Diseño de Equipo , Imagen por Resonancia Magnética , Fantasmas de Imagen , Ondas de Radio , Imagen por Resonancia Magnética/instrumentación , Protección Radiológica/instrumentación , Humanos , Análisis de Falla de Equipo
5.
Magn Reson Med ; 91(6): 2332-2344, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38171541

RESUMEN

PURPOSE: To quantitatively map the myelin lipid-protein bilayer in the live human brain. METHODS: This goal was pursued by integrating a multi-TE acquisition approach targeting ultrashort T2 signals with voxel-wise fitting to a three-component signal model. Imaging was performed at 3 T in two healthy volunteers using high-performance RF and gradient hardware and the HYFI sequence. The design of a suitable imaging protocol faced substantial constraints concerning SNR, imaging volume, scan time, and RF power deposition. Model fitting to data acquired using the proposed protocol was made feasible through simulation-based optimization, and filtering was used to condition noise presentation and overall depiction fidelity. RESULTS: A multi-TE protocol (11 TEs of 20-780 µs) for in vivo brain imaging was developed in adherence with applicable safety regulations and practical scan time limits. Data acquired using this protocol produced accurate model fitting results, validating the suitability of the protocol for this purpose. Structured, grainy texture of myelin bilayer maps was observed and determined to be a manifestation of correlated image noise resulting from the employed acquisition strategy. Map quality was significantly improved by filtering to uniformize the k-space noise distribution and simultaneously extending the k-space support. The final myelin bilayer maps provided selective depiction of myelin, reconciling competitive resolution (1.4 mm) with adequate SNR and benign noise texture. CONCLUSION: Using the proposed technique, quantitative maps of the myelin bilayer can be obtained in vivo. These maps offer unique information content with potential applications in basic research, diagnosis, disease monitoring, and drug development.


Asunto(s)
Imagen por Resonancia Magnética , Vaina de Mielina , Humanos , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Mapeo Encefálico/métodos , Imagenología Tridimensional/métodos
6.
MAGMA ; 37(2): 169-183, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38197908

RESUMEN

OBJECTIVE: To assess the possible influence of third-order shim coils on the behavior of the gradient field and in gradient-magnet interactions at 7 T and above. MATERIALS AND METHODS: Gradient impulse response function measurements were performed at 5 sites spanning field strengths from 7 to 11.7 T, all of them sharing the same exact whole-body gradient coil design. Mechanical fixation and boundary conditions of the gradient coil were altered in several ways at one site to study the impact of mechanical coupling with the magnet on the field perturbations. Vibrations, power deposition in the He bath, and field dynamics were characterized at 11.7 T with the third-order shim coils connected and disconnected inside the Faraday cage. RESULTS: For the same whole-body gradient coil design, all measurements differed greatly based on the third-order shim coil configuration (connected or not). Vibrations and gradient transfer function peaks could be affected by a factor of 2 or more, depending on the resonances. Disconnecting the third-order shim coils at 11.7 T also suppressed almost completely power deposition peaks at some frequencies. DISCUSSION: Third-order shim coil configurations can have major impact in gradient-magnet interactions with consequences on potential hardware damage, magnet heating, and image quality going beyond EPI acquisitions.


Asunto(s)
Imagen por Resonancia Magnética , Imanes , Imagen por Resonancia Magnética/métodos
7.
Magn Reson Med ; 91(5): 1876-1892, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38234052

RESUMEN

PURPOSE: Navigator-based correction of rigid-body motion reconciling high precision with minimal acquisition, minimal calibration and simple, fast processing. METHODS: A short orbital navigator (2.3 ms) is inserted in a three-dimensional (3D) gradient echo sequence for human head imaging. Head rotation and translation are determined by linear regression based on a complex-valued model built either from three reference navigators or in a reference-less fashion, from the first actual navigator. Optionally, the model is expanded by global phase and field offset. Run-time scan correction on this basis establishes servo control that maintains validity of the linear picture by keeping its expansion point stable in the head frame of reference. The technique is assessed in a phantom and demonstrated by motion-corrected imaging in vivo. RESULTS: The proposed approach is found to establish stable motion control both with and without reference acquisition. In a phantom, it is shown to accurately detect motion mimicked by rotation of scan geometry as well as change in global B0 . It is demonstrated to converge to accurate motion estimates after perturbation well beyond the linear signal range. In vivo, servo navigation achieved motion detection with precision in the single-digit range of micrometers and millidegrees. Involuntary and intentional motion in the range of several millimeters were successfully corrected, achieving excellent image quality. CONCLUSION: The combination of linear regression and feedback control enables prospective motion correction for head imaging with high precision and accuracy, short navigator readouts, fast run-time computation, and minimal demand for reference data.


Asunto(s)
Imagenología Tridimensional , Imagen por Resonancia Magnética , Humanos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Modelos Lineales , Retroalimentación , Estudios Prospectivos , Movimiento (Física) , Artefactos
8.
Sci Adv ; 9(32): eadi0611, 2023 08 11.
Artículo en Inglés | MEDLINE | ID: mdl-37566661

RESUMEN

Multiple sclerosis (MS) is a neuroinflammatory disease characterized by loss of myelin (demyelination) and, to a certain extent, subsequent myelin repair (remyelination). To better understand the pathomechanisms underlying de- and remyelination and to monitor the efficacy of treatments aimed at regenerating myelin, techniques offering noninvasive visualizations of myelin are warranted. Magnetic resonance (MR) imaging has long been at the forefront of efforts to visualize myelin, but it has only recently become feasible to access the rapidly decaying resonance signals stemming from the myelin lipid-protein bilayer itself. Here, we show that direct MR mapping of the bilayer yields highly specific myelin maps in brain tissue from patients with MS. Furthermore, examination of the bilayer signal behavior is found to reveal pathological alterations in normal-appearing white and gray matter. These results indicate promise for in vivo implementations of the myelin bilayer mapping technique, with prospective applications in basic research, diagnostics, disease monitoring, and drug development.


Asunto(s)
Esclerosis Múltiple , Vaina de Mielina , Humanos , Vaina de Mielina/patología , Esclerosis Múltiple/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Espectroscopía de Resonancia Magnética
9.
J Magn Reson ; 348: 107401, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36774713

RESUMEN

Temporal diffusion spectroscopy (TDS) currently uses the oscillating gradient spin echo (OGSE) experiment to measure the spectral density of translational velocity autocorrelation at single frequencies. Due to timing restrictions imposed by the transverse relaxation, the frequency selectivity and the sampling density of OGSE are limited, especially at low frequencies. We propose to overcome this problem by adopting the principles of Fourier transform spectroscopy. The new method of Fourier transform TDS (FTDS) uses two broadband gradient waveforms with different relative delays to make the spin echo attenuation sensitive to a broad range of diffusion frequencies with different harmonic modulations and calculates the spectrum by discrete Fourier transform. The method was validated by a measurement of diffusion spectra in highly restrictive tissues of a celery stalk and provided results consistent with OGSE, however, on a denser frequency grid.

10.
Magn Reson Med ; 89(2): 665-677, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36253953

RESUMEN

PURPOSE: To explore the properties of short-T2 signals in human brain, investigate the impact of various experimental procedures on these properties and evaluate the performance of three-component analysis. METHODS: Eight samples of non-pathological human brain tissue were subjected to different combinations of experimental procedures including D2 O exchange and frozen storage. Short-T2 imaging techniques were employed to acquire multi-TE (33-2067 µs) data, to which a three-component complex model was fitted in two steps to recover the properties of the underlying signal components and produce amplitude maps of each component. For validation of the component amplitude maps, the samples underwent immunohistochemical myelin staining. RESULTS: The signal component representing the myelin bilayer exhibited super-exponential decay with T2,min of 5.48 µs and a chemical shift of 1.07 ppm, and its amplitude could be successfully mapped in both white and gray matter in all samples. These myelin maps corresponded well to myelin-stained tissue sections. Gray matter signals exhibited somewhat different components than white matter signals, but both tissue types were well represented by the signal model. Frozen tissue storage did not alter the signal components but influenced component amplitudes. D2 O exchange was necessary to characterize the non-aqueous signal components, but component amplitude mapping could be reliably performed also in the presence of H2 O signals. CONCLUSIONS: The myelin mapping approach explored here produced reasonable and stable results for all samples. The extensive tissue and methodological investigations performed in this work form a basis for signal interpretation in future studies both ex vivo and in vivo.


Asunto(s)
Vaina de Mielina , Sustancia Blanca , Humanos , Vaina de Mielina/química , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Sustancia Gris/diagnóstico por imagen , Sustancia Blanca/diagnóstico por imagen
11.
Data Brief ; 42: 108050, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35372651

RESUMEN

We present data collected for the research article "Advances in Spiral fMRI: A High-resolution Study with Single-shot Acquisition" (Kasper et al. 2022). All data was acquired on a 7T ultra-high field MR system (Philips Achieva), equipped with a concurrent magnetic field monitoring setup based on 16 NMR probes. For task-based fMRI, a visual quarterfield stimulation paradigm was employed, alongside physiological monitoring via peripheral recordings. This data collection contains different datasets pertaining to different purposes: (1) Measured magnetic field dynamics (k0, spiral k-space trajectories, 2nd order spherical harmonics, concomitant fields) during ultra-high field fMRI sessions from six subjects, as well as concurrent temperature curves of the gradient coil, to explore MR system and subject-induced variability of field fluctuations and assess the impact of potential correction methods. (2) MR Raw Data, i.e., coil and concurrent encoding magnetic field (trajectory) data, of a single subject, as well as nominal spiral gradient waveforms, precomputed B0 and coil sensitivity maps, to enable testing of alternative image reconstruction approaches for spiral fMRI data. (3) Reconstructed image time series of the same subject alongside behavioral and physiological logfiles, to reproduce the fMRI preprocessing and analysis, as well as figures presented in the research article related to this article, using the published analysis code repository. All data is provided in standardized formats for the respective research area. In particular, ISMRMRD (HDF5) is used to store raw coil data and spiral trajectories, as well as measured field dynamics. Likewise, the NIfTI format is used for all imaging data (anatomical MRI and spiral fMRI, B0 and coil sensitivity maps).

12.
Front Aging Neurosci ; 14: 811146, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35309894

RESUMEN

Introduction: Hippocampal atrophy is an established Alzheimer's Disease (AD) biomarker. Volume loss in specific subregions as measurable with ultra-high field magnetic resonance imaging (MRI) may reflect earliest pathological alterations. Methods: Data from positron emission tomography (PET) for estimation of cortical amyloid ß (Aß) and high-resolution 7 Tesla T1 MRI for assessment of hippocampal subfield volumes were analyzed in 61 non-demented elderly individuals who were divided into risk-categories as defined by high levels of cortical Aß and low performance in standardized episodic memory tasks. Results: High cortical Aß and low episodic memory interactively predicted subicular volume [F(3,57) = 5.90, p = 0.018]. The combination of high cortical Aß and low episodic memory was associated with significantly lower subicular volumes, when compared to participants with high episodic memory (p = 0.004). Discussion: Our results suggest that low subicular volume is linked to established indicators of AD risk, such as increased cortical Aß and low episodic memory. Our data support subicular volume as a marker of dementia-risk susceptibility in old-aged non-demented persons.

13.
Magn Reson Med ; 87(6): 2710-2723, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35049104

RESUMEN

PURPOSE: To address the long echo times and relatively weak diffusion sensitization that typically limit oscillating gradient spin-echo (OGSE) experiments, an OGSE implementation combining spiral readouts, gap-filled oscillating gradient shapes providing stronger diffusion encoding, and a high-performance gradient system is developed here and utilized to investigate the tradeoff between b-value and maximum OGSE frequency in measurements of diffusion dispersion (i.e., the frequency dependence of diffusivity) in the in vivo human brain. In addition, to assess the effects of the marginal flow sensitivity introduced by these OGSE waveforms, flow-compensated variants are devised for experimental comparison. METHODS: Using DTI sequences, OGSE acquisitions were performed on three volunteers at b-values of 300, 500, and 1000 s/mm2 and frequencies up to 125, 100, and 75 Hz, respectively; scans were performed for gap-filled oscillating gradient shapes with and without flow sensitivity. Pulsed gradient spin-echo DTI acquisitions were also performed at each b-value. Upon reconstruction, mean diffusivity (MD) maps and maps of the diffusion dispersion rate were computed. RESULTS: The power law diffusion dispersion model was found to fit best to MD measurements acquired at b = 1000 s/mm2 despite the associated reduction of the spectral range; this observation was consistent with Monte Carlo simulations. Furthermore, diffusion dispersion rates without flow sensitivity were slightly higher than flow-sensitive measurements. CONCLUSION: The presented OGSE implementation provided an improved depiction of diffusion dispersion and demonstrated the advantages of measuring dispersion at higher b-values rather than higher frequencies within the regimes employed in this study.


Asunto(s)
Encéfalo , Imagen de Difusión por Resonancia Magnética , Encéfalo/diagnóstico por imagen , Difusión , Humanos , Método de Montecarlo
14.
Magn Reson Med ; 87(1): 272-280, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34398985

RESUMEN

PURPOSE: The aim of this work is the reconciliation of high spatial and temporal resolution for MRI. For this purpose, a novel sampling strategy for 3D encoding is proposed, which provides flexible k-space segmentation along with uniform sampling density and benign filtering effects related to signal decay. METHODS: For time-critical MRI applications such as functional MRI (fMRI), 3D k-space is usually sampled by stacking together 2D trajectories such as echo planar imaging (EPI) or spiral readouts, where each shot covers one k-space plane. For very high temporal and medium to low spatial resolution, tilted hexagonal sampling (T-Hex) was recently proposed, which allows the acquisition of a larger k-space volume per excitation than can be covered with a planar readout. Here, T-Hex is described in a modified version where it instead acquires a smaller k-space volume per shot for use with medium temporal and high spatial resolution. RESULTS: Mono-planar T-Hex sampling provides flexibility in the choice of speed, signal-to-noise ratio (SNR), and contrast for rapid MRI acquisitions. For use with a conventional gradient system, it offers the greatest benefit in a regime of high in-plane resolution <1 mm. The sampling scheme is combined with spirals for high sampling speed as well as with more conventional EPI trajectories. CONCLUSION: Mono-planar T-Hex sampling combines fast 3D encoding with SNR efficiency and favorable depiction characteristics regarding noise amplification and filtering effects from T2∗ decay, thereby providing flexibility in the choice of imaging parameters. It is attractive both for high-resolution time series such as fMRI and for applications that require rapid anatomical imaging.


Asunto(s)
Encéfalo , Imagenología Tridimensional , Encéfalo/diagnóstico por imagen , Imagen Eco-Planar , Imagen por Resonancia Magnética , Relación Señal-Ruido
15.
Magn Reson Med ; 87(3): 1360-1374, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34775617

RESUMEN

PURPOSE: To overcome limitations in the duration of RF excitation in zero-TE (ZTE) MRI by exploiting intrinsic encoding properties of RF pulses to retrieve data missed during the dead time caused by the pulse. METHODS: An enhanced ZTE signal model was developed using multiple RF pulses, which enables accessing information hidden in the pulse-induced dead time via encoding intrinsically applied by the RF pulses. Such ZTE with pulse encoding was implemented by acquisition of two ZTE data sets using excitation with similar frequency-swept pulses differing only by a small off-resonance in their center frequency. In this way, the minimum scan time is doubled but each acquisition contributes equally to the SNR, as with ordinary averaging. The method was demonstrated on long-T2 and short-T2 phantoms as well as in in vivo experiments. RESULTS: ZTE with pulse encoding provided good image quality at unprecedented dead-time gaps, demonstrated here up to 6 Nyquist dwells. In head imaging, the ability to use longer excitation pulses led to approximately 2-fold improvements in SNR efficiency as compared with conventional ZTE and allowed the creation of T1 contrast. CONCLUSION: Exploiting intrinsic encoding properties of RF pulses in a new signal model enables algebraic reconstruction of ZTE data sets with large dead-time gaps. This permits larger flip angles, which can be used to achieve enhanced T1 contrast and significant improvements in SNR efficiency in case the Ernst angle can be better approached, thus broadening the range of application of ZTE MRI.


Asunto(s)
Algoritmos , Imagen por Resonancia Magnética , Frecuencia Cardíaca , Fantasmas de Imagen
16.
Magn Reson Med ; 87(5): 2224-2238, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34932233

RESUMEN

PURPOSE: Many aspects and imperfections of gradient dynamics in MRI have been successfully captured by linear time-invariant (LTI) models. Changes in gradient behavior due to heating, however, violate time invariance. The goal of this work is to study such changes at the level of transfer functions and model them by thermal extension of the LTI framework. METHODS: To study the impact of gradient heating on transfer functions, a clinical MR system was heated using a range of high-amplitude DC and AC waveforms, each followed by measuring transfer functions in rapid succession while the system cooled down. Simultaneously, gradient temperature was monitored with an array of temperature sensors positioned according to initial infrared recordings of the gradient tube. The relation between temperatures and transfer functions is cast into local and global linear models. The models are analysed in terms of self-consistency, conditioning, and prediction performance. RESULTS: Pronounced thermal effects are observed in the time resolved transfer functions, largely attributable to in-coil eddy currents and mechanical resonances. Thermal modeling is found to capture these effects well. The keys to good model performance are well-placed temperature sensors and suitable training data. CONCLUSION: Heating changes gradient response, violating time invariance. The utility of LTI modeling can nevertheless be recovered by a linear thermal extension, relying on temperature sensing and adequate one-time training.


Asunto(s)
Imagen por Resonancia Magnética , Modelos Lineales , Fantasmas de Imagen
17.
Neuroimage ; 246: 118738, 2022 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-34800666

RESUMEN

Spiral fMRI has been put forward as a viable alternative to rectilinear echo-planar imaging, in particular due to its enhanced average k-space speed and thus high acquisition efficiency. This renders spirals attractive for contemporary fMRI applications that require high spatiotemporal resolution, such as laminar or columnar fMRI. However, in practice, spiral fMRI is typically hampered by its reduced robustness and ensuing blurring artifacts, which arise from imperfections in both static and dynamic magnetic fields. Recently, these limitations have been overcome by the concerted application of an expanded signal model that accounts for such field imperfections, and its inversion by iterative image reconstruction. In the challenging ultra-high field environment of 7 Tesla, where field inhomogeneity effects are aggravated, both multi-shot and single-shot 2D spiral imaging at sub-millimeter resolution was demonstrated with high depiction quality and anatomical congruency. In this work, we further these advances towards a time series application of spiral readouts, namely, single-shot spiral BOLD fMRI at 0.8 mm in-plane resolution. We demonstrate that high-resolution spiral fMRI at 7 T is not only feasible, but delivers both excellent image quality, BOLD sensitivity, and spatial specificity of the activation maps, with little artifactual blurring. Furthermore, we show the versatility of the approach with a combined in/out spiral readout at a more typical resolution (1.5 mm), where the high acquisition efficiency allows to acquire two images per shot for improved sensitivity by echo combination.


Asunto(s)
Encéfalo/diagnóstico por imagen , Encéfalo/fisiología , Neuroimagen Funcional/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Adulto , Estudios de Factibilidad , Femenino , Humanos , Masculino , Adulto Joven
18.
Neuroimage ; 245: 118674, 2021 12 15.
Artículo en Inglés | MEDLINE | ID: mdl-34718138

RESUMEN

Spiral imaging is very well suited for functional MRI, however its use has been limited by the fact that artifacts caused by gradient imperfections and B0 inhomogeneity are more difficult to correct compared to EPI. Effective correction requires accurate knowledge of the traversed k-space trajectory. With the goal of making spiral fMRI more accessible, we have evaluated image reconstruction using trajectories predicted by the gradient impulse response function (GIRF), which can be determined in a one-time calibration step. GIRF-predicted reconstruction was tested for high-resolution (0.8 mm) fMRI at 7T. Image quality and functional results of the reconstructions using GIRF-prediction were compared to reconstructions using the nominal trajectory and concurrent field monitoring. The reconstructions using nominal spiral trajectories contain substantial artifacts and the activation maps contain misplaced activation. Image artifacts are substantially reduced when using the GIRF-predicted reconstruction, and the activation maps for the GIRF-predicted and monitored reconstructions largely overlap. The GIRF reconstruction provides a large increase in the spatial specificity of the activation compared to the nominal reconstruction. The GIRF-reconstruction generates image quality and fMRI results similar to using a concurrently monitored trajectory. The presented approach does not prolong or complicate the fMRI acquisition. Using GIRF-predicted trajectories has the potential to enable high-quality spiral fMRI in situations where concurrent trajectory monitoring is not available.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Algoritmos , Artefactos , Mapeo Encefálico , Calibración , Estudios de Factibilidad , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Fantasmas de Imagen
19.
NMR Biomed ; 34(6): e4493, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33624305

RESUMEN

The aim of this work was to improve the SNR efficiency of zero echo time (ZTE) MRI pulse sequences for faster imaging of short-T2 components at large dead-time gaps. ZTE MRI with hybrid filling (HYFI) is a strategy for retrieving inner k-space data missed during the dead-time gaps arising from radio-frequency excitation and switching in ZTE imaging. It performs hybrid filling of the inner k-space with a small single-point-imaging core surrounded by a stack of shells acquired on radial readouts in an onion-like fashion. The exposition of this concept is followed by translation into guidelines for parameter choice and implementation details. The imaging properties and performance of HYFI are studied in simulations as well as phantom, in vitro and in vivo imaging, with an emphasis on comparison with the pointwise encoding time reduction with radial acquisition (PETRA) technique. Simulations predict higher SNR efficiency for HYFI compared with PETRA at preserved image quality, with the advantage increasing with the size of the k-space gap. These results are confirmed by imaging experiments with gap sizes of 25 to 50 Nyquist dwells, in which scan times for similar image quality could be reduced by 25% to 60%. The HYFI technique provides both high SNR efficiency and image quality, thus outperforming previously known ZTE-based pulse sequences, in particular for large k-space gaps. Promising applications include direct imaging of ultrashort-T2 components, such as the myelin bilayer or collagen, T2 mapping of ultrafast relaxing signals, and ZTE imaging with reduced chemical shift artifacts.


Asunto(s)
Imagen Eco-Planar , Algoritmos , Animales , Huesos/diagnóstico por imagen , Bovinos , Simulación por Computador , Humanos , Rodilla/diagnóstico por imagen , Fantasmas de Imagen , Procesamiento de Señales Asistido por Computador , Factores de Tiempo
20.
Magn Reson Med ; 85(5): 2882-2891, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33433044

RESUMEN

PURPOSE: To explore the use of conductive elastomer for MR signal detection and the utility of this approach for wearable detector arrays. METHODS: An elastomer filled with silver microparticles was used to form stretchable radiofrequency coils for MR detection. Their electrical performance in terms of the Qunloaded and Q ratio was assessed in the relaxed state and under repeated strain up to 40%. In a phantom imaging study, the signal-to-noise ratio yield of conductive elastomer coils was compared with that of a reference copper coil. Four elastomer coils were integrated with a stretchable textile substrate to form a wearable array for knee imaging. The array was employed for multiple-angle and kinematic knee imaging in vivo. RESULTS: The elastomer coils proved highly stretchable and mechanically robust. Upon repeated stretching by 20%, a medium-sized coil element settled at Qunloaded of 42 in the relaxed state and 32 at full strain, reflecting sample-noise dominance. The signal-to-noise ratio of elastomer coils was found to be 8% to 16% lower than that achieved with a conventional copper coil. Multiple-angle and kinematic knee imaging with the wearable array yielded high-quality results indicating robustness of detection performance against stretching and warping of the array. CONCLUSION: Conductive elastomer is a viable material for MR detection. Coils made from this material reconcile high stretchability and adequate electrical performance with ease of manufacturing. Conductive elastomer also offers inherent restoring forces and is readily washable and sanitizable, making it an excellent basis of wearable detector front ends.