Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
Rev Sci Instrum ; 95(2)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38341717

RESUMEN

To achieve stable operation of an ion cyclotron resonance heating (ICRH) system in the Experimental Advanced Superconducting Tokamak (EAST), a real-time impedance matching system needs to be established to respond to antenna load variation during long pulse discharges. A new impedance matching method based on capacitors was proposed in this study. By considering the reflected voltage of the transmission line as the feedback parameter, the real-time impedance-matching system can quickly control the motors based on a programmable logic controller to determine the minimum reflection voltage. A real-time impedance matching system was successfully used on the test platform in the laboratory and on the ICRH system in EAST. A significant result is that we can match the variable impedance within 1 s by suitably adjusting the motor controller to ensure high-power and long-pulse operation of the ICRH system to satisfy the requirements of the EAST experiment.

2.
Rev Sci Instrum ; 95(1)2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38214588

RESUMEN

The Ion Cyclotron Range of Frequency (ICRF) heating system of the China Fusion Engineering Test Reactor (CFETR) is intended to provide plasma heating with a minimum power output of 20 MW, which demands the Radio Frequency (RF) window to possess a higher performance requirement. This paper presents the design of an RF window for the CFETR ICRF heating system and focuses primarily on the design and confirmation of its electromagnetic performance. The RF window can be effectively matched in the operating frequency range and has an S11 of under -59 dB. The geometry of the cone type ceramics was optimized to reduce the surface tangential electric field distribution. An analysis of the electric field distribution of the RF window at 50 kV indicates that the pressure side was below 2.3 kV/mm and the vacuum side was below 1.3 kV/mm. Furthermore, a transmission line test bench with an open-terminated setup was constructed to conduct withstand voltage tests on the mockup, and the results showed that the mockup could withstand 62 kV for 2 s and 47 kV for 120 s.

3.
Rev Sci Instrum ; 93(4): 043506, 2022 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-35489959

RESUMEN

Ion cyclotron resonance heating (ICRH), one of the main auxiliary methods, for high-power and long-pulse plasma heating had been developed in Experimental Advanced Superconducting Tokamak (EAST). An impedance matching system, one important part of ICRH, had been developed for high-power injection and transmitter protection by reducing the reflected power from the antenna. The input impedance in the outlet of the stub tuner can be measured by voltage-current probes installed on the coaxial transmission line between the antenna and triple liquid stub tuners, and the optimum liquid levels in the stub tuners can be calculated based on the input impedance. The calculation and adjustment process of the optimum liquid levels are described comprehensively in this article. Finally, impedance matching had been achieved between two shots during EAST experiments. In the near future, a real-time impedance matching system will be developed to prevent large variations of the ICRH antenna impedance and achieve steady-state and long-pulse operation with the ICRH system.

4.
Rev Sci Instrum ; 90(6): 063504, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31255010

RESUMEN

A passive and noninvasive diagnostic system based on high-frequency B-dot probes (HFBs) has been designed and developed for the measurement and identification of ion cyclotron emission (ICE) in the Experimental Advanced Superconducting Tokamak (EAST). Details of the hardware components of this system including HFBs, direct current blockers, radio frequency splitters, filters, and power detectors as well as data acquisition systems are presented. A spectrum analyzer is used in addition to the ordinary speed acquisition card for data registration and analysis. The reliability of a HFB based diagnostic system has been well validated during the 2018 spring experiments on the EAST. ICE signals corresponding to fundamental cyclotron frequency of hydrogen ions and harmonics of deuterium ions were observed in experiments where deuterium plasmas were heated with deuterium neutral beams. The field dependence of ICE has been verified by recent experiments with three different background magnetic fields. The observed ratio of the ICE frequency is consistent with the ratio of the magnetic field intensity within measurement errors of a few percent.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA