Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Cardiovasc Intervent Radiol ; 40(11): 1800-1803, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28508251

RESUMEN

This case describes a technique used to close a long-term 14F transpleural biliary drainage catheter tract to prevent biliopleural fistula and further complications. We deployed a compressed gelatin foam pledget provided in a pre-loaded delivery device (Hep-Plug™) along the intrahepatic tissue tract for sealing it against the pleural cavity. The device used is easy to handle and gives the Interventional Radiologist the possibility to safely manage and prevent complications after percutaneous transhepatic interventions.


Asunto(s)
Fístula Biliar/prevención & control , Sistema Biliar/diagnóstico por imagen , Cateterismo/instrumentación , Drenaje/instrumentación , Gelatina/uso terapéutico , Radiografía Intervencional/métodos , Cateterismo/efectos adversos , Cateterismo/métodos , Drenaje/métodos , Fluoroscopía/métodos , Humanos , Masculino , Persona de Mediana Edad
2.
J Vasc Interv Radiol ; 27(6): 913-921.e2, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27103147

RESUMEN

PURPOSE: To evaluate the effects of combined use of transarterial chemoembolization and irreversible electroporation (IRE) for focal tissue ablation in an acute porcine liver model. MATERIALS AND METHODS: Two established interventional techniques were combined: IRE with zones of irreversible and reversible electroporation and chemoembolization with microspheres, iodized oil, and doxorubicin. IRE was performed before chemoembolization in two pigs (pigs 1 and 2; IRE/chemoembolization group), chemoembolization was performed before IRE in two pigs (pigs 3 and 4; chemoembolization/IRE group), and only IRE was performed in two pigs (pigs 5 and 6). Five study groups were defined: IRE/chemoembolization (pigs 1 and 2), chemoembolization/IRE (pigs 3 and 4), IRE only (pigs 5 and 6), chemoembolization only (tissue outside the IRE zones in pigs 1-4), and control (untreated liver tissue outside the IRE zones in pigs 5 and 6). Animals were euthanized 2 hours after intervention. Size and shape of IRE zones on contrast-enhanced computed tomography, cell death on light microscopy, and doxorubicin tissue concentrations on chromatography and fluorescence microscopy were analyzed. RESULTS: Size and shape of IRE zones were not significantly different (eg, P = .067 for volume). A histologic marker for irreversible cell death was positive in IRE/chemoembolization, chemoembolization/IRE, and IRE groups only in the macroscopically visible IRE zones. Doxorubicin tissue concentrations were not significantly different (P = .873). However, in the reversible electroporation (RE) zones, broad areas with intense intranuclear doxorubicin accumulation were observed in IRE/chemoembolization but not in chemoembolization/IRE and chemoembolization groups. CONCLUSIONS: IRE before chemoembolization enhances the intranuclear accumulation of doxorubicin in the RE zone.


Asunto(s)
Antibióticos Antineoplásicos/administración & dosificación , Quimioembolización Terapéutica/métodos , Doxorrubicina/administración & dosificación , Electroquimioterapia , Hígado/efectos de los fármacos , Animales , Antibióticos Antineoplásicos/metabolismo , Biopsia , Muerte Celular/efectos de los fármacos , Doxorrubicina/metabolismo , Aceite Yodado/administración & dosificación , Hígado/diagnóstico por imagen , Hígado/metabolismo , Hígado/patología , Modelos Animales , Porcinos , Factores de Tiempo , Tomografía Computarizada por Rayos X
3.
Int J Comput Assist Radiol Surg ; 11(1): 107-17, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26018847

RESUMEN

PURPOSE: Percutaneous needle insertions are increasingly used for diagnosis and treatment of abdominal lesions. The challenging part of computed tomography (CT)-guided punctures is the transfer of the insertion trajectory planned in the CT image to the patient. Conventionally, this often results in several needle repositionings and control CT scans. To address this issue, several navigation systems for percutaneous needle insertions have been presented; however, none of them has thus far become widely accepted in clinical routine. Their benefit for the patient could not exceed the additional higher costs and the increased complexity in terms of bulky tracking systems and specialized markers for registration and tracking. METHODS: We present the first markerless and trackerless navigation concept for real-time patient localization and instrument guidance. It has specifically been designed to be integrated smoothly into the clinical workflow and does not require markers or an external tracking system. The main idea is the utilization of a range imaging device that allows for contactless and radiation-free acquisition of both range and color information used for patient localization and instrument guidance. RESULTS: A first feasibility study in phantom and porcine models yielded a median targeting accuracy of 6.9 and 19.4 mm, respectively. CONCLUSIONS: Although system performance remains to be improved for clinical use, expected advances in camera technology as well as consideration of respiratory motion and automation of the individual steps will make this approach an interesting alternative for guiding percutaneous needle insertions.


Asunto(s)
Agujas , Punciones/métodos , Tomografía Computarizada por Rayos X/métodos , Humanos , Fantasmas de Imagen , Flujo de Trabajo
4.
Pancreas ; 44(5): 791-8, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25931252

RESUMEN

OBJECTIVES: Use of thermal tumor ablation in the pancreatic parenchyma is limited because of the risk of pancreatitis, pancreatic fistula, or hemorrhage. This study aimed to evaluate the feasibility and safety of irreversible electroporation (IRE) in a porcine model. METHODS: Ten pigs were divided into 2 study groups. In the first group, animals received IRE of the pancreatic tail and were killed after 60 minutes. In the second group, animals received IRE at the head of the pancreas and were followed up for 7 days. Clinical parameters, computed tomography imaging, laboratory results, and histology were obtained. RESULTS: All animals survived IRE ablation, and no cardiac adverse effects were noted. Sixty minutes after IRE, a hypodense lesion on computed tomography imaging indicated the ablation zone. None of the animals developed clinical signs of acute pancreatitis. Only small amounts of ascites fluid, with a transient increase in amylase and lipase levels, were observed, indicating that no pancreatic fistula occurred. CONCLUSIONS: This porcine model shows that IRE is feasible and safe in the pancreatic parenchyma. Computed tomography imaging reveals significant changes at 60 minutes after IRE and therefore might serve as an early indicator of therapeutic success. Clinical studies are needed to evaluate the efficacy of IRE in pancreatic cancer.


Asunto(s)
Técnicas de Ablación , Electroporación , Páncreas/cirugía , Amilasas/sangre , Animales , Biomarcadores/sangre , Estudios de Factibilidad , Femenino , Lipasa/sangre , Modelos Animales , Necrosis , Páncreas/diagnóstico por imagen , Páncreas/enzimología , Páncreas/patología , Medición de Riesgo , Sus scrofa , Factores de Tiempo , Tomografía Computarizada por Rayos X
5.
J Vasc Interv Radiol ; 26(5): 746-54, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25704223

RESUMEN

PURPOSE: To evaluate and compare irinotecan elution kinetics of two drug-eluting embolic agents in a porcine model. MATERIALS AND METHODS: Embolization of the left liver lobe was performed in 16 domestic pigs, with groups of two receiving 1 mL of DC Bead M1 (70-150 µm) or Embozene TANDEM (75 µm) loaded with 50 mg irinotecan. Irinotecan plasma levels were measured at 0, 10, 20, 30, 60, 120, 180, and 240 minutes after completed embolization and at the time of euthanasia (24 h, 48 h, 72 h, or 7 d). Liver tissue samples were taken to measure irinotecan tissue concentrations. RESULTS: The highest irinotecan plasma concentrations of both embolic agents were measured 10 and 20 minutes after embolization, and concentrations were significantly higher for DC Bead M1 versus Embozene TANDEM (P = .0019 and P = .0379, respectively). At 48 hours and later follow-up, no irinotecan was measurable in the plasma. For both embolic agents, the highest irinotecan tissue concentration was found after 24 hours and decreased in a time-dependent manner at later follow-up intervals. Additionally, SN-38 tissue levels for both agents were therapeutic at 24 hours, with therapeutic levels of SN-38 at 48 hours in one liver embolized with TANDEM particles. Histopathologic analysis revealed ischemic, inflammatory, and fibrotic tissue reactions. CONCLUSIONS: Irinotecan is measurable in plasma and hepatic tissue after liver embolization with both types of irinotecan-eluting embolic agents. DC Bead M1 shows early burst elution kinetics, whereas Embozene TANDEM has a lower and slower release profile. The initial burst is significantly greater after embolization with DC Bead M1 than with Embozene TANDEM.


Asunto(s)
Antineoplásicos Fitogénicos/administración & dosificación , Camptotecina/análogos & derivados , Quimioembolización Terapéutica/métodos , Animales , Antineoplásicos Fitogénicos/farmacocinética , Camptotecina/administración & dosificación , Camptotecina/farmacocinética , Modelos Animales de Enfermedad , Femenino , Irinotecán , Neoplasias Hepáticas/tratamiento farmacológico , Neoplasias Hepáticas/patología , Porcinos
6.
J Vasc Interv Radiol ; 25(7): 1018-1026.e4, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24768235

RESUMEN

PURPOSE: To histologically evaluate the efficacy and nontarget effects induced by transarterial chemoembolization as a "bridge" treatment of hepatocellular carcinoma (HCC) before liver transplantation (LT) and its relation to patient survival. MATERIALS AND METHODS: Between October 2003 and January 2011, 51 patients with HCC underwent LT after chemoembolization with iodized oil, small spherical particles, and carboplatin. The decision for LT was made according to national guidelines. The efficacy and nontarget effects of chemoembolization were determined histologically in explanted livers, and their impact on patients' survival after LT was analyzed. RESULTS: A total of 126 chemoembolization procedures were performed in 51 patients; the median number of procedures per patient was three (range, one to six). The extent of HCC necrosis was less than or equal to 50% in 32% of treated HCCs, more than 50% and less than or equal to 90% in 17%, and more than 90%-99% in 14%; 38% showed complete necrosis of the lesion. The most common nontarget effects were focal necrosis of the liver parenchyma adjacent to the embolized HCC nodule (28%), intralesional (micro)abscess (26%), intralesional hemorrhage (22%), and peritumoral bile duct necrosis (12%). Based on histopathologic examination, 35% of patients had HCC that did not meet Milan criteria. None of these findings was significantly associated with patient survival after LT. CONCLUSIONS: Transarterial chemoembolization induces histopathologically confirmed HCC necrosis with a high degree of efficacy, but histologically proven complete HCC necrosis was not predictive of survival in this cohort of patients. Although histopathologic examination revealed (clinically relevant) nontarget effects in a subset of patients, they did not impair survival.


Asunto(s)
Carboplatino/administración & dosificación , Carcinoma Hepatocelular/terapia , Quimioembolización Terapéutica , Aceite Yodado/administración & dosificación , Neoplasias Hepáticas/terapia , Trasplante de Hígado , Terapia Neoadyuvante , Anciano , Carboplatino/efectos adversos , Carcinoma Hepatocelular/mortalidad , Carcinoma Hepatocelular/patología , Quimioembolización Terapéutica/efectos adversos , Quimioembolización Terapéutica/mortalidad , Femenino , Alemania , Humanos , Aceite Yodado/efectos adversos , Estimación de Kaplan-Meier , Neoplasias Hepáticas/mortalidad , Neoplasias Hepáticas/patología , Masculino , Persona de Mediana Edad , Necrosis , Terapia Neoadyuvante/efectos adversos , Terapia Neoadyuvante/mortalidad , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
7.
BMC Med Imaging ; 14: 2, 2014 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-24410997

RESUMEN

BACKGROUND: Size and shape of the treatment zone after Irreversible electroporation (IRE) can be difficult to depict due to the use of multiple applicators with complex spatial configuration. Exact geometrical definition of the treatment zone, however, is mandatory for acute treatment control since incomplete tumor coverage results in limited oncological outcome. In this study, the "Chebyshev Center Concept" was introduced for CT 3d rendering to assess size and position of the maximum treatable tumor at a specific safety margin. METHODS: In seven pig livers, three different IRE protocols were applied to create treatment zones of different size and shape: Protocol 1 (n = 5 IREs), Protocol 2 (n = 5 IREs), and Protocol 3 (n = 5 IREs). Contrast-enhanced CT was used to assess the treatment zones. Technique A consisted of a semi-automated software prototype for CT 3d rendering with the "Chebyshev Center Concept" implemented (the "Chebyshev Center" is the center of the largest inscribed sphere within the treatment zone) with automated definition of parameters for size, shape and position. Technique B consisted of standard CT 3d analysis with manual definition of the same parameters but position. RESULTS: For Protocol 1 and 2, short diameter of the treatment zone and diameter of the largest inscribed sphere within the treatment zone were not significantly different between Technique A and B. For Protocol 3, short diameter of the treatment zone and diameter of the largest inscribed sphere within the treatment zone were significantly smaller for Technique A compared with Technique B (41.1 ± 13.1 mm versus 53.8 ± 1.1 mm and 39.0 ± 8.4 mm versus 53.8 ± 1.1 mm; p < 0.05 and p < 0.01). For Protocol 1, 2 and 3, sphericity of the treatment zone was significantly larger for Technique A compared with B. CONCLUSIONS: Regarding size and shape of the treatment zone after IRE, CT 3d rendering with the "Chebyshev Center Concept" implemented provides significantly different results compared with standard CT 3d analysis. Since the latter overestimates the size of the treatment zone, the "Chebyshev Center Concept" could be used for a more objective acute treatment control.


Asunto(s)
Electroporación/métodos , Imagenología Tridimensional/métodos , Hígado/diagnóstico por imagen , Neoplasias/patología , Tomografía Computarizada por Rayos X/métodos , Animales , Humanos , Procesamiento de Imagen Asistido por Computador , Neoplasias/diagnóstico por imagen , Porcinos
8.
J Vasc Interv Radiol ; 24(12): 1888-97, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24267525

RESUMEN

PURPOSE: To analyze irreversible electroporation (IRE) of the pig kidney with involvement of the renal pelvis. MATERIALS AND METHODS: IRE of renal tissue including the pelvis was performed in 10 kidneys in five pigs. Three study groups were defined: group I (two applicators with parallel configuration; n = 11), group II (three applicators with triangular configuration; n = 2), and group III (six applicators with complex configuration; n = 3). After IRE and before euthanasia, pigs underwent contrast-enhanced computed tomography (CT). Technical aspects (radial distance of applicators, resulting mean current), clinical outcome (complications, blood samples), and three-dimensional CT rendering for assessment of the treatment zone (short axis, circularity) were assessed. RESULTS: Radial distances of applicators were 14.3 mm ± 2.8 in group I, 12.3 mm ± 1.9 in group II, and 16.4 mm ± 3.5 in group III. Resulting mean currents were 25.7 A ± 6.5 in group I, 27.0 A ± 7.1 in group II, and 39.4 A ± 8.9 in group III. In group III, two perirenal hematomas were identified. There was no damage to the renal pelvis. During IRE, clinical blood parameters and cardiovascular markers did not change significantly. Short axis measurements were 20.6 mm ± 3.6 in group I, 31.9 mm ± 8.2 in group II, and 39.3 mm ± 2.4 in group III (P < .01 between groups). Circularity scores were 0.8 ± 0.2 in group I, 0.7 ± 0.1 in group II, and 0.7 ± 0.1 in group III, with a score of 1 indicating perfect roundness (P value not significant). CONCLUSIONS: IRE of the pig kidney with involvement of the renal pelvis is feasible and safe. Size but not shape of the treatment zone is significantly affected by applicator configuration.


Asunto(s)
Técnicas de Ablación , Electroporación , Imagenología Tridimensional , Pelvis Renal/cirugía , Tomografía Computarizada por Rayos X , Animales , Estudios de Factibilidad , Procesamiento de Imagen Asistido por Computador , Pelvis Renal/diagnóstico por imagen , Pelvis Renal/patología , Modelos Animales , Porcinos
9.
Int J Hyperthermia ; 29(7): 620-8, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24001114

RESUMEN

PURPOSE: This paper outlines a theoretical approach for optimisation of the coagulation zone for thermal ablation procedures and considerations for its practical application. METHODS: The theoretical approach is outlined in the Cartesian coordinate system. Considerations for practical application are implemented. The optimised coagulation zone is defined as the bare coverage of tumour mass plus a safety margin. The eccentricity of coagulation centre (ECC) is defined as the distance between the coagulation centre and the tumour centre. The direction of the applicator shaft is determined based on the x-axis direction. The tumour centre and coagulation centre are defined within the x/y-plane. The distance between coagulation margin (applicator tip) and tumour margin is called parallel offset (PAO). RESULTS: For spherical coagulation shapes, a linear relationship exists between optimised coagulation diameter and ECC. An exponential relationship exists between optimised coagulation volume and ECC. A complex relationship was found between PAO and determinants of ECC, which are ex and ey. PAO is an extremely important parameter, which allows for determination of the optimal applicator tip position in relation to the tumour margin. It can be calculated in such a manner that the optimised coagulation zone is minimised by neutralising dislocation of the coagulation centre in applicator shaft direction. The latter can be realised by withdrawing or further inserting the applicator shaft. CONCLUSIONS: The presented concept can be used to optimise the extent of the coagulation zone for thermal ablation procedures after positioning of the applicator. Its inherent advantage is the simple adjustment of the applicator shaft, which obviates the need for a repuncture.


Asunto(s)
Coagulación Sanguínea , Hipertermia Inducida , Neoplasias/terapia , Modelos Teóricos , Neoplasias/sangre
10.
J Vasc Interv Radiol ; 24(8): 1241-8, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23792128

RESUMEN

PURPOSE: To quantify the extent of tissue shrinkage and dehydration caused by microwave (MW) ablation in kidneys for estimation of effective coagulation volume. MATERIALS AND METHODS: MW ablations were carried out in ex vivo porcine kidneys. Six study groups were defined: groups 1A, 2A, and 3A for MW ablation (90 W for 5 min, 7.5 min, or 10 min), and groups 1B, 2B, and 3B for control (without MW ablation). Pre- and postinterventional volume analyses were performed. Effective coagulation volumes (original tissue included in coagulation) were determined. Postinterventional dehydration analyses were performed with calculation of mean mass fractions of water. RESULTS: Mean deployed energies were 21.6 kJ ± 1.1 for group 1A, 29.9 kJ ± 1.0 for group 2A, and 42.1 kJ ± 0.5 kJ for group 3A, and were significantly different (P < .0001). Differences between pre- and postinterventional volumes were -3.8% ± 0.6 for group 1A, -5.6% ± 0.9 for group 2A, and -7.2% ± 0.4 for group 3A, and -1.1% ± 0.3 for group 1B, -1.8% ± 0.4 for group 2B, and -1.1% ± 0.4 for group 3B. Postinterventional volumes were significantly smaller than preinterventional volumes for all groups (P < .01). Underestimations of effective coagulation volume from visualized coagulation volume were 26.1% ± 3.5 for group 1A, 35.2% ± 11.2 for group 2A, and 42.1% ± 4.9 for group 3A, which were significantly different (P < .01). Mean mass fractions of water were 64.2% ± 1.4 for group 1A, 63.2% ± 1.7 for group 2A, and 62.6% ± 1.8% for group 3A, with significant differences versus corresponding control groups (P < .01). CONCLUSIONS: For MW ablation in kidneys, underestimation of effective coagulation volume based on visualized coagulation volume is significantly greater with greater deployed energy. Therefore, local dehydration with tissue shrinkage is a potential contributor.


Asunto(s)
Deshidratación/patología , Electrocoagulación/métodos , Riñón/cirugía , Microondas , Animales , Deshidratación/etiología , Electrocoagulación/efectos adversos , Riñón/patología , Modelos Lineales , Microondas/efectos adversos , Tamaño de los Órganos , Porcinos
11.
Surg Endosc ; 27(10): 3663-70, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23549772

RESUMEN

BACKGROUND: Navigation systems potentially facilitate minimally invasive esophagectomy and improve patient outcome by improving intraoperative orientation, position estimation of instruments, and identification of lymph nodes and resection margins. The authors' self-developed navigation system is highly accurate in static environments. This study aimed to test the overall accuracy of the navigation system in a realistic operating room scenario and to identify the different sources of error altering accuracy. METHODS: To simulate a realistic environment, a porcine model (n = 5) was used with endoscopic clips in the esophagus as navigation targets. Computed tomography imaging was followed by image segmentation and target definition with the medical imaging interaction toolkit software. Optical tracking was used for registration and localization of animals and navigation instruments. Intraoperatively, the instrument was displayed relative to segmented organs in real time. The target registration error (TRE) of the navigation system was defined as the distance between the target and the navigation instrument tip. The TRE was measured on skin targets with the animal in the 0° supine and 25° anti-Trendelenburg position and on the esophagus during laparoscopic transhiatal preparation. RESULTS: On skin targets, the TRE was significantly higher in the 25° position, at 14.6 ± 2.7 mm, compared with the 0° position, at 3.2 ± 1.3 mm. The TRE on the esophagus was 11.2 ± 2.4 mm. The main source of error was soft tissue deformation caused by intraoperative positioning, pneumoperitoneum, surgical manipulation, and tissue dissection. CONCLUSION: The navigation system obtained acceptable accuracy with a minimally invasive transhiatal approach to the esophagus in a realistic experimental model. Thus the system has the potential to improve intraoperative orientation, identification of lymph nodes and adequate resection margins, and visualization of risk structures. Compensation methods for soft tissue deformation may lead to an even more accurate navigation system in the future.


Asunto(s)
Esofagectomía/métodos , Esofagoscopía/métodos , Radiografía Intervencional/métodos , Cirugía Asistida por Computador/métodos , Cirugía Asistida por Video/métodos , Algoritmos , Animales , Calibración , Esófago/anatomía & histología , Esófago/cirugía , Marcadores Fiduciales , Ganglios Linfáticos/anatomía & histología , Fantasmas de Imagen , Radiografía Intervencional/instrumentación , Programas Informáticos , Cirugía Asistida por Computador/instrumentación , Sus scrofa , Porcinos , Tomografía Computarizada por Rayos X , Cirugía Asistida por Video/instrumentación
12.
Invest Radiol ; 48(4): 213-22, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23399807

RESUMEN

OBJECTIVE: The objective of this study was to test multimodal visibility (radiography, computed tomography [CT], and magnetic resonance imaging [MRI]) of microspheres for transarterial embolization in porcine kidneys. MATERIALS AND METHODS: Currently available embolization particles (microspheres) were modified. A dense x-ray material (barium sulfate) was added to create visibility for radiography and CT. A magnetic substance (iron oxide) was additionally added to create visibility for MRI. This chemical modification was performed for particles with sizes of 100 ± 25 and 700 ± 50 µm. Three different prototypes per size class (samples A, B, and C) resulted, each with a different degree of barium sulfate but with the same degree of iron oxide. The currently available embolization particles with sizes of 100 ± 25 and 700 ± 50 µm were used as controls (sample control). Eight renal arteries of 4 pigs were embolized. Study end points were size distribution evaluated in vitro as well as qualitative and quantitative particle visibility evaluated in vivo. RESULTS: The size distribution of the particles with a size of 100 ± 25 µm was between 96 ± 11 µm for sample A and 102 ± 13 µm for the sample control without significant differences (n.s.). The size distribution of the particles with a size of 700 ± 50 µm was between 691 ± 20 µm for sample A and 716 ± 34 µm for sample C without significant differences (n.s.). For radiography, the particles with sizes of 100 ± 25 and 700 ± 50 µm for samples A, B, and C were definitely visible during the embolization. The sample control was definitely not visible. For CT and MRI (T1-weighted [T1w] and T2-weighted [T2w]), the particles with sizes of 100 ± 25 and 700 ± 50 µm for samples A, B, and C were definitely visible after the embolization. The sample control was definitely not visible. For CT, the signal-to-noise ratio for samples A, B, and C increased significantly after the embolization (eg, sample A, particles with a size of 100 ± 25 µm: 66.5% ± 23.7%, P < 0.05). The signal-to-noise ratio for the sample control did not change after the embolization (eg, sample control, particles with a size of 700 ± 25 µm: -0.2% ± 15.2%, n.s.). For MRI (T1w and T2w), the signal-to-noise ratio for samples A, B, and C decreased significantly after the embolization (eg, sample B, particles with a size of 700 ± 50 µm, T1w: -72.9% ± 6.6%; P < 0.05). The signal-to-noise ratio for the sample control did not change after the embolization (eg, sample control, particles with a size of 100 ± 25 µm, T2w: 6.2% ± 16.1%, n.s.). CONCLUSIONS: In this study, the chemical modification of the currently available microspheres for transarterial embolization resulted in a size distribution comparable with the currently available microspheres and created multimodal visibility for radiography, CT, and MRI.


Asunto(s)
Embolización Terapéutica/métodos , Riñón , Imagen por Resonancia Magnética/métodos , Microesferas , Tomografía Computarizada por Rayos X/métodos , Animales , Sulfato de Bario/administración & dosificación , Medios de Contraste/administración & dosificación , Dextranos/administración & dosificación , Femenino , Nanopartículas de Magnetita/administración & dosificación , Porcinos
13.
Int J Hyperthermia ; 29(1): 21-9, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23311376

RESUMEN

PURPOSE: This study aimed to compare retrospectively bipolar RF ablation with multipolar RF ablation for the treatment of renal cell carcinoma. MATERIALS AND METHODS: Between March 2009 and June 2012, 12 tumours (nine patients) treated with bipolar RF ablation (one applicator) and 14 tumours (11 patients) treated with multipolar RF ablation (two applicators) were compared systematically. Selection between bipolar RF ablation and multipolar RF ablation was operator choice considering tumour size. Study goals included differences in tumour and coagulation extent, and technical parameters (total RF energy delivery and RF ablation time per coagulation volume). RESULTS: Tumour maximum diameter was significantly larger for multipolar RF ablation compared with bipolar RF ablation (27.0 mm versus 19.4 mm; p < 0.01). This difference is partially dependent on operator choice. Coagulation length, width and volume were significantly larger for multipolar RF ablation compared with bipolar RF ablation (35.0 mm versus 26.5 mm, 27.5 mm versus 23.0 mm and 14.3 cm(3) versus 8.1 cm(3); p < 0.01, p < 0.05 and p < 0.05, respectively). Coagulation circularity was not significantly different between both study groups (0.8 versus 0.8; not significant). Total RF energy delivery was significantly higher and RF ablation time per coagulation volume was significantly shorter for multipolar RF ablation compared with bipolar RF ablation (52.0 kJ versus 28.6 kJ and 2.4 min/cm(3) versus 4.1 min/cm(3); p < 0.05 and p < 0.05, respectively). CONCLUSIONS: Multipolar RF ablation creates a significantly larger coagulation width, but identical coagulation shape, compared with bipolar RF ablation. Additionally, multipolar RF ablation coagulates faster according to the shorter RF ablation time per coagulation volume.


Asunto(s)
Carcinoma de Células Renales/cirugía , Ablación por Catéter/métodos , Neoplasias Renales/cirugía , Anciano , Anciano de 80 o más Años , Carcinoma de Células Renales/patología , Femenino , Humanos , Neoplasias Renales/patología , Masculino , Carga Tumoral
14.
Dig Surg ; 29(3): 236-42, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22797287

RESUMEN

PURPOSE: The purpose of this retrospective study was to evaluate the efficacy and safety of percutaneous transhepatic portal vein embolization (PVE) of the right liver lobe using Histoacryl/Lipiodol mixture to induce contralateral liver hypertrophy before right-sided (or extended right-sided) hepatectomy in patients with primarily unresectable liver tumors. METHODS: Twenty-one patients (9 females and 12 males) underwent PVE due to an insufficient future liver remnant; 17 showed liver metastases and 4 suffered from biliary cancer. Imaging was performed prior to and 4 weeks after PVE. Surgery was scheduled for 1 week after a CT or MRI control. The primary study end point was technical success, defined as complete angiographical occlusion of the portal vein. The secondary study end point was evaluation of liver hypertrophy by CT and MRI volumetry and transfer to operability. RESULTS: In all the patients, PVE could be performed with a Histoacryl/Lipiodol mixture (n = 20) or a Histoacryl/Lipiodol mixture with microcoils (n = 1). No procedure-related complications occurred. The volume of the left liver lobe increased significantly (p < 0.0001) by 28% from a mean of 549 ml to 709 ml. Eighteen of twenty-one patients (85.7%) could be transferred to surgery, and the intended resection could be performed as planned in 13/18 (72.3%) patients. CONCLUSION: Preoperative right-sided PVE using a Histoacryl/Lipiodol mixture is a safe technique and achieves a sufficient hypertrophy of the future liver remnant in the left liver lobe.


Asunto(s)
Embolización Terapéutica , Gastrinoma/cirugía , Neoplasias Hepáticas/terapia , Tumores Neuroendocrinos/cirugía , Adaptación Fisiológica , Adulto , Anciano , Anciano de 80 o más Años , Antineoplásicos/administración & dosificación , Enbucrilato/administración & dosificación , Aceite Etiodizado/administración & dosificación , Femenino , Gastrinoma/secundario , Hepatectomía , Hepatomegalia/diagnóstico por imagen , Humanos , Hígado/anatomía & histología , Hígado/diagnóstico por imagen , Hígado/fisiología , Neoplasias Hepáticas/secundario , Neoplasias Hepáticas/cirugía , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Tumores Neuroendocrinos/secundario , Tamaño de los Órganos , Vena Porta/diagnóstico por imagen , Cuidados Preoperatorios , Radiografía , Estudios Retrospectivos , Estadísticas no Paramétricas , Adhesivos Tisulares/administración & dosificación
15.
Eur J Radiol ; 81(4): 692-9, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21353419

RESUMEN

PURPOSE: To evaluate whether virtual non-enhanced imaging (VNI) is effective to replace true non-enhanced imaging (TNI) applying iodine removal in intravenous dual-energy CT-cholangiography. MATERIALS AND METHODS: From April 2009 until February 2010, fifteen potential donors for living-related liver transplantation (mean age 37.6±10.8 years) were included. Potential donors underwent a two-phase CT-examination of the liver. The first phase consisted of a single-energy non-enhanced CT-acquisition that provided TNI. After administration of hepatobiliary contrast agent, the second phase was performed as a dual-energy cholangiographic CT-acquisition. This provided VNI. Objective image quality (attenuation values [bile ducts and liver parenchyma] and contrast-to-noise ratio) and subjective overall image quality (1 - excellent; 5 - non diagnostic) were evaluated. Effective radiation dose was compared. RESULTS: For TNI and VNI, attenuation values for bile ducts were 16.8±11.2HU and 5.5±17.0HU (p<0.05) and for liver parenchyma 55.3±8.4HU and 58.1±10.6HU (n.s.). For TNI and VNI, contrast-to-noise ratio was 2.6±0.6HU and 6.9±2.1HU (p<0.001). For VNI, subjective overall image quality was 1 in ten datasets, 2 in four datasets and 3 in one dataset. Effective radiation dose for the dual-energy cholangiographic CT-acquisition was 3.6±0.9mSv and for two-phase single-energy CT-cholangiography 5.1±1.3mSv (p<0.001). CONCLUSION: In this study on iodine removal in intravenous dual-energy CT-cholangiography, subjective image quality is equivalent, contrast-to-noise ratio is improved and effective radiation dose is reduced when VNI is performed. The differences between TNI and VNI with respect to attenuation values seem to have limited clinical relevance and therefore we consider VNI as effective to replace TNI.


Asunto(s)
Colangiografía/métodos , Yodipamida/análogos & derivados , Trasplante de Hígado/diagnóstico por imagen , Hígado/diagnóstico por imagen , Donadores Vivos , Tomografía Computarizada por Rayos X/métodos , Adulto , Medios de Contraste , Humanos , Masculino , Persona de Mediana Edad , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
16.
Eur J Radiol ; 81(9): 2273-80, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21784593

RESUMEN

PURPOSE: To compare retrospectively angiographical and clinical results in patients undergoing transjugular intrahepatic portosystemic stent-shunt (TIPS) using BMS or VSG. MATERIALS AND METHODS: From February 2001 to January 2010, 245 patients underwent TIPS. From those, 174 patients matched the inclusion criteria with elective procedures and institutional follow-up. Group (I) consisted of 116 patients (mean age, 57.0±11.1 years) with BMS. Group (II) consisted of 58 patients with VSG (mean age, 53.5±16.1 years). Angiographic and clinical controls were scheduled at 3, 6 and 12 months, followed by clinical controls every 6 months. Primary study goals included hemodynamic success, shunt patency as well as time to and number of revisions. Secondary study goals included clinical success. RESULTS: Hemodynamic success was 92.2% in I and 91.4% in II (n.s.). Primary patency was significantly higher in II compared to I (53.8% after 440.4±474.5 days versus 45.8% after 340.1±413.8 days; p<0.05). The first TIPS revision was performed significantly later in II compared to I (288.3±334.7 days versus 180.1±307.0 days; p<0.05). In the first angiographic control, a portosystemic pressure gradient ≥15 mmHg was present in 73.9% in I and in 39.4% in II (p<0.05). Clinical success was 73.7-86.2% after 466.3±670.1 days in I and 85.7-90.5% after 617.5±642.7 days in II (n.s.). Hepatic encephalopathy was 37.5% in I and 36.5% in II (n.s.). CONCLUSION: VSG increased primary shunt patency as well as decreased time to and number of TIPS revisions. There was a trend of higher clinical success in VSG without increased hepatic encephalopathy.


Asunto(s)
Hepatopatías/epidemiología , Hepatopatías/cirugía , Derivación Portosistémica Intrahepática Transyugular/instrumentación , Adulto , Anciano , Anciano de 80 o más Años , Prótesis Vascular , Femenino , Alemania/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Factores de Riesgo , Stents , Resultado del Tratamiento , Adulto Joven
17.
J Vasc Interv Radiol ; 22(12): 1751-7, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21982204

RESUMEN

PURPOSE: To determine the effect of tissue perfusion on microwave ablation lesions in an experimental in vivo study in porcine kidneys. MATERIALS AND METHODS: Twelve kidneys of six pigs were studied. In each animal, two microwave ablations were created in one kidney without limitation of tissue perfusion (group 1). In the other kidney, two microwave ablations were performed with interruption of blood flow (group 2). All microwave ablations were performed with identical system parameters (eg, temperature control mode, ablation time of 80 s, and temperature of 110°C). The animals were euthanized 3 hours later. The kidneys were harvested and cut into 2-3-mm transverse slices. Microwave ablation zone dimensions (eg, length, width, and volume) and shape (eg, sphericity ratio) and corresponding variability were compared between groups. RESULTS: Microwave ablation areas were significantly longer (41.6 mm ± 4.0 vs 34.2 mm ± 5.9; P < .01) and wider (16.6 mm ± 1.2 vs 12.2 mm ± 2.1; P < .001) in group 2 than in group 1. Similarly, microwave ablation volume was significantly greater in group 2 compared with group 1 (6.7 cm(3) ± 1.0 vs 3.3 cm(3) ± 1.2; P < .001). Ablation area shapes were similar between groups (sphericity ratio, 2.57 ± 0.42 vs 2.39 ± 0.34). Ablation area variabilities were also comparable between groups (volume variance of 1.32 vs 0.93; sphericity ratio variance of 0.18 vs 0.11). CONCLUSIONS: After interruption of blood flow, microwave ablation areas are significantly larger than those achieved without limitation of tissue perfusion. Microwave ablation area shape and variability were comparable between study groups.


Asunto(s)
Ablación por Catéter/métodos , Riñón/fisiopatología , Riñón/efectos de la radiación , Animales , Velocidad del Flujo Sanguíneo/fisiología , Riñón/irrigación sanguínea , Microondas/uso terapéutico , Porcinos
18.
Med Phys ; 38(6): 3246-59, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21815399

RESUMEN

PURPOSE: Computed tomography (CT) guided minimally invasive interventions such as biopsies or ablation therapies often involve insertion of a needle-shaped instrument into the target organ (e.g., the liver). Today, these interventions still require manual planning of a suitable trajectory to the target (e.g., the tumor) based on the slice data provided by the imaging modality. However, taking into account the critical structures and other parameters crucial to the success of the intervention--such as instrument shape and penetration angle--is challenging and requires a lot of experience. METHODS: To overcome these problems, we present a system for the automatic or semiautomatic planning of optimal trajectories to a target, based on 3D reconstructions of all relevant structures. The system determines possible insertion zones based on so-called hard constraints and rates the quality of these zones by so-called soft constraints. The concept of pareto optimality is utilized to allow for a weight-independent proposal of insertion trajectories. In order to demonstrate the benefits of our method, automatic trajectory planning was applied retrospectively to n = 10 data sets from interventions in which complications occurred. RESULTS: The efficient (graphics processing unit-based) implementation of the constraints results in a mean overall planning time of about 9 s. The examined trajectories, originally chosen by the physician, have been rated as follows: in six cases, the insertion point was labeled invalid by the planning system. For two cases, the system would have proposed points with a better rating according to the soft constraints. For the remaining two cases the system would have indicated poor rating with respect to one of the soft constraints. The paths proposed by our system were rated feasible and qualitatively good by experienced interventional radiologists. CONCLUSIONS: The proposed computer-assisted trajectory planning system is able to detect unsafe and propose safe insertion trajectories and may especially be helpful for interventional radiologist at the beginning or during their interventional training.


Asunto(s)
Agujas , Piel , Cirugía Asistida por Computador/métodos , Humanos , Estudios Retrospectivos , Seguridad , Cirugía Asistida por Computador/efectos adversos
19.
Clin Transplant ; 25(5): E541-51, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21518002

RESUMEN

BACKGROUND: The selection criteria for liver transplantation (LT) in patients with hepatocellular cancer (HCC) are well defined. Increasing evidence suggests that the effectiveness of pre-transplant bridging influences the individual course after LT significantly. Thus, the aim of this study was to determine its impact on tumor progression during waiting time and identify patient subgroups with favorable oncological long-term outcome. METHODS: Prospectively collected data of 78 consecutive patients undergoing LT for HCC between 2001 and 2007 were analyzed retrospectively. Survival rates were assessed using the Kaplan-Meier estimate. Clinicopathologic prognostic factors were identified by Cox regression analysis. RESULTS: After 48.9 months of median follow-up, the five-yr overall survival rate is 57% with a five-yr recurrence-free survival rate of 74%. Progressive disease (PD) during bridging was developed in 32% of patients, and a trend toward impaired overall survival in patients with PD before LT was detected in multivariate analysis (p = 0.073). HCC ≥3 cm was associated with a three times increased risk of recurrent disease. Neither fulfillment of MILAN criteria nor bridging with transarterial chemoembolization had an impact on the outcome. CONCLUSION: PD during waiting time influences the oncological course after LT. However, even with an increasing organ shortage, further studies are warranted to define clear selection criteria based on the biological tumor behavior and allow a more personalized treatment.


Asunto(s)
Carcinoma Hepatocelular/mortalidad , Neoplasias Hepáticas/mortalidad , Trasplante de Hígado/mortalidad , Donadores Vivos , Recurrencia Local de Neoplasia/prevención & control , Adulto , Anciano , Carcinoma Hepatocelular/patología , Carcinoma Hepatocelular/cirugía , Femenino , Estudios de Seguimiento , Humanos , Neoplasias Hepáticas/patología , Neoplasias Hepáticas/cirugía , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Estudios Retrospectivos , Tasa de Supervivencia , Resultado del Tratamiento
20.
Ann Surg ; 253(6): 1111-7, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21412146

RESUMEN

OBJECTIVE: Comparison of two different insertion techniques for implantation of totally implantable access ports (TIAP). BACKGROUND: TIAP are introduced through different open and closed cannulation strategies and by various medical experts. The aim of this expertise-based randomized trial was to compare venous cutdown approach with puncture of subclavian vein. METHODS: One hundred and ten patients scheduled for primary implantation of a TIAP were randomly assigned to either open insertion technique performed by surgeons or puncture of the subclavian vein under fluoroscopic guidance by radiologists at an outpatient single university center. The primary endpoint was the primary success rate of the cannulation strategy. A logistic regression model was used for analysis adjusting for age, Karnofsky index, body mass index and surgeons', and the radiologists' experience. RESULTS: Percutaneus cannulation was not superior to surgical venous cutdown in the intention-to-treat analysis (odds ratio, 0.37; 95% CI, 0.07; 2.15) and the as-treated analysis (odds ratio, 0.16; 95% CI, 0; 1.28). The procedure was shorter with surgery (median, 21 minutes; 95% CI, 14; 30) than with radiology (median, 45 minutes; 95% CI, 43; 50) (P < 0.001), and the dose of radiation was lower with surgery (median, 37 cGy/cm(2); 95% CI, 26; 49) than with radiology (200 cGy/cm(2); 95% CI, 200; 300) (P < 0.001). CONCLUSION: Central venous cannulation for insertion of TIAPs can be performed safely and effectively with both approaches. The open direct surgical access requires further strategies for successful placement of a TIAP, and percutaneous Seldinger technique requires more time and a higher dose of radiation and is associated with risk of pneumothorax.


Asunto(s)
Cateterismo Venoso Central/métodos , Catéteres de Permanencia , Anciano , Femenino , Fluoroscopía , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Punciones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA