Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
2.
Artículo en Inglés | MEDLINE | ID: mdl-39146219

RESUMEN

OBJECTIVE: Pulmonary CT angiography (CTA) to detect pulmonary emboli can be performed using conventional dual-source CT with single-energy acquisition at high-pitch (high-pitch conventional CT), which minimizes motion artifacts, or routine-pitch, dual-energy acquisitions (routine-pitch conventional DECT), which maximize iodine signal. We compared iodine signal, radiation dose, and motion artifacts of pulmonary CTA between these conventional CT modalities and dual-source photon-counting detector CT with high-pitch, multienergy acquisitions (high-pitch photon-counting CT). METHODS: Consecutive clinically indicated pulmonary CTA exams were collected. CT number/noise was measured from the main to right lower lobe segmental pulmonary arteries using 120 kV threshold low, 120 kV, and mixed kV (0.6 linear blend) images. Three radiologists reviewed anonymized, randomized exams, rating them using a 4- or 5-point Likert scale (1 = worst, and 4/5 = best) for contrast enhancement in pulmonary arteries, motion artifacts in aortic root to subsegmental pulmonary arteries, lung image quality; pulmonary blood volume (PBV) map image quality (for multienergy or dual-energy exams), and contribution to reader confidence. RESULTS: One hundred fifty patients underwent high-pitch photon-counting CT (n = 50), high-pitch conventional CT (n = 50), and routine-pitch conventional DECT (n = 50). High-pitch photon-counting CT had lower radiation dose (CTDIvol: 8.1 ± 2.5 vs 9.6 ± 6.8 and 16.2 ± 8.5 mGy, respectively; P < 0.001), and routine-pitch conventional DECT had significantly less contrast (P < 0.009). CT number and CNR measurements were significantly greater at high-pitch photon-counting CT (P < 0.001). Across readers, high-pitch photon-counting CT demonstrated significantly higher subjective contrast enhancement in the pulmonary arteries compared to the other modalities (4.7 ± 0.6 vs 4.4 ± 0.7 vs 4.3 ± 0.7; P = 0.011) and lung image quality (3.4 ± 0.5 vs 3.1 ± 0.5 vs 3.1 ± 0.5; P = 0.013). High-pitch photon-counting CT and high-pitch conventional CT had fewer motion artifacts at all levels compared to DECT (P < 0.001). High-pitch photon-counting CT PBV maps had superior image quality (P < 0.001) and contribution to reader confidence (P < 0.001) compared to routine-pitch conventional DECT. CONCLUSION: High-pitch photon-counting pulmonary CTA demonstrated higher contrast in pulmonary arteries at lower radiation doses with improved lung image quality and fewer motion artifacts compared to high-pitch conventional CT and routine-pitch conventional dual-energy CT.

3.
Radiographics ; 44(9): e230222, 2024 09.
Artículo en Inglés | MEDLINE | ID: mdl-39115996

RESUMEN

Cardiac electrophysiology involves the diagnosis and management of arrhythmias. CT and MRI play an increasingly important role in cardiac electrophysiology, primarily in preprocedural planning of ablation procedures but also in procedural guidance and postprocedural follow-up. The most common applications include ablation for atrial fibrillation (AF), ablation for ventricular tachycardia (VT), and for planning cardiac resynchronization therapy (CRT). For AF ablation, preprocedural evaluation includes anatomic evaluation and planning using CT or MRI as well as evaluation for left atrial fibrosis using MRI, a marker of poor outcomes following ablation. Procedural guidance during AF ablation is achieved by fusing anatomic data from CT or MRI with electroanatomic mapping to guide the procedure. Postprocedural imaging with CT following AF ablation is commonly used to evaluate for complications such as pulmonary vein stenosis and atrioesophageal fistula. For VT ablation, both MRI and CT are used to identify scar, representing the arrhythmogenic substrate targeted for ablation, and to plan the optimal approach for ablation. CT or MR images may be fused with electroanatomic maps for intraprocedural guidance during VT ablation and may also be used to assess for complications following ablation. Finally, functional information from MRI may be used to identify patients who may benefit from CRT, and cardiac vein mapping with CT or MRI may assist in planning access. ©RSNA, 2024 Supplemental material is available for this article.


Asunto(s)
Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Imagen por Resonancia Magnética/métodos , Ablación por Catéter/métodos , Taquicardia Ventricular/diagnóstico por imagen , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Técnicas Electrofisiológicas Cardíacas/métodos , Arritmias Cardíacas/diagnóstico por imagen
4.
Radiographics ; 44(8): e230124, 2024 08.
Artículo en Inglés | MEDLINE | ID: mdl-39052499

RESUMEN

Kidney failure (KF) refers to a progressive decline in glomerular filtration rate to below 15 ml/min per 1.73 m2, necessitating renal replacement therapy with dialysis or renal transplant. The hemodynamic and metabolic alterations in KF combined with a proinflammatory and coagulopathic state leads to complex multisystemic complications. The imaging hallmark of systemic manifestations of KF is bone resorption caused by secondary hyperparathyroidism. Other musculoskeletal complications include brown tumor, osteosclerosis, calcinosis, soft-tissue calcification, and amyloid arthropathy. Cardiovascular complications and infections are the leading causes of death in KF. Cardiovascular complications include accelerated atherosclerosis, cardiomyopathy, pericarditis, myocardial calcinosis, and venous thromboembolism. Neurologic complications such as encephalopathy, osmotic demyelination, cerebrovascular disease, and opportunistic infections are also frequently encountered. Pulmonary complications include edema and calcifications. Radiography and CT are used in assessing musculoskeletal and thoracic complications, while MRI plays a key role in assessing neurologic and cardiovascular complications. CT iodinated contrast material is generally avoided in patients with KF except in situations where the benefit of contrast-enhanced CT outweighs the risks and in patients already undergoing maintenance dialysis. At MRI, group II gadolinium-based contrast material can be safely administered in patients with KF. The authors discuss the extrarenal systemic manifestations of KF, the choice of imaging modality in their assessment, and imaging findings of complications. ©RSNA, 2024 Supplemental material is available for this article.


Asunto(s)
Insuficiencia Renal , Humanos , Insuficiencia Renal/diagnóstico por imagen , Enfermedades Cardiovasculares/diagnóstico por imagen
5.
AJR Am J Roentgenol ; 2024 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-38984783

RESUMEN

The use of cardiac CT and MRI is rapidly expanding based on strong evidence from large international trials. The number of physicians competent to interpret cardiac CT and MRI may be unable to keep pace with the increasing demand. Societies and organizations have prescribed training requirements for interpreting cardiac CT and MRI, with recent updates focusing on the increased breadth of competency that is now required due to ongoing imaging advances. In this AJR Expert Panel Narrative Review, we discuss several aspects of cardiac CT and MRI training, focusing on topics that are uncertain or not addressed in existing society statements and guidelines, including determination of competency in different practice types in real-world settings and the impact of artificial intelligence on training and education. The article is intended to guide updates in professional society training requirements and also inform institutional verification processes.

6.
Radiographics ; 44(7): e230156, 2024 07.
Artículo en Inglés | MEDLINE | ID: mdl-38870043

RESUMEN

Accurate evaluation of the mitral valve (MV) apparatus is essential for understanding the mechanisms of MV disease across various clinical scenarios. The mitral annulus (MA) is a complex and crucial structure that supports MV function; however, conventional imaging techniques have limitations in fully capturing the entirety of the MA. Moreover, recognizing annular changes might aid in identifying patients who may benefit from advanced cardiac imaging and interventions. Multimodality cardiovascular imaging plays a major role in the diagnosis, prognosis, and management of MV disease. Transthoracic echocardiography is the first-line modality for evaluation of the MA, but it has limitations. Cardiac MRI (CMR) has emerged as a robust imaging modality for assessing annular changes, with distinct advantages over other imaging techniques, including accurate flow and volumetric quantification and assessment of variations in the measurements and shape of the MA during the cardiac cycle. Mitral annular disjunction (MAD) is defined as atrial displacement of the hinge point of the MV annulus away from the ventricular myocardium, a condition that is now more frequently diagnosed and studied owing to recent technical advances in cardiac imaging. However, several unresolved issues regarding MAD, such as the functional significance of pathologic disjunction and how this disjunction advances in the clinical course, require further investigation. The authors review the role of CMR in the assessment of MA disease, with a focus on MAD and its functional implications in MV prolapse and mitral regurgitation. ©RSNA, 2024 Supplemental material is available for this article. See the invited commentary by Stojanovska and Fujikura in this issue.


Asunto(s)
Imagen por Resonancia Magnética , Válvula Mitral , Humanos , Válvula Mitral/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen
8.
Radiology ; 310(3): e231986, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38501953

RESUMEN

Photon-counting CT (PCCT) is an emerging advanced CT technology that differs from conventional CT in its ability to directly convert incident x-ray photon energies into electrical signals. The detector design also permits substantial improvements in spatial resolution and radiation dose efficiency and allows for concurrent high-pitch and high-temporal-resolution multienergy imaging. This review summarizes (a) key differences in PCCT image acquisition and image reconstruction compared with conventional CT; (b) early evidence for the clinical benefit of PCCT for high-spatial-resolution diagnostic tasks in thoracic imaging, such as assessment of airway and parenchymal diseases, as well as benefits of high-pitch and multienergy scanning; (c) anticipated radiation dose reduction, depending on the diagnostic task, and increased utility for routine low-dose thoracic CT imaging; (d) adaptations for thoracic imaging in children; (e) potential for further quantitation of thoracic diseases; and (f) limitations and trade-offs. Moreover, important points for conducting and interpreting clinical studies examining the benefit of PCCT relative to conventional CT and integration of PCCT systems into multivendor, multispecialty radiology practices are discussed.


Asunto(s)
Radiología , Tomografía Computarizada por Rayos X , Niño , Humanos , Procesamiento de Imagen Asistido por Computador , Fotones
9.
Radiographics ; 44(3): e230083, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38329901

RESUMEN

Metabolic syndrome comprises a set of risk factors that include abdominal obesity, impaired glucose tolerance, hypertriglyceridemia, low high-density lipoprotein levels, and high blood pressure, at least three of which must be fulfilled for diagnosis. Metabolic syndrome has been linked to an increased risk of cardiovascular disease and type 2 diabetes mellitus. Multimodality imaging plays an important role in metabolic syndrome, including diagnosis, risk stratification, and assessment of complications. CT and MRI are the primary tools for quantification of excess fat, including subcutaneous and visceral adipose tissue, as well as fat around organs, which are associated with increased cardiovascular risk. PET has been shown to detect signs of insulin resistance and may detect ectopic sites of brown fat. Cardiovascular disease is an important complication of metabolic syndrome, resulting in subclinical or symptomatic coronary artery disease, alterations in cardiac structure and function with potential progression to heart failure, and systemic vascular disease. CT angiography provides comprehensive evaluation of the coronary and systemic arteries, while cardiac MRI assesses cardiac structure, function, myocardial ischemia, and infarction. Liver damage results from a spectrum of nonalcoholic fatty liver disease ranging from steatosis to fibrosis and possible cirrhosis. US, CT, and MRI are useful in assessing steatosis and can be performed to detect and grade hepatic fibrosis, particularly using elastography techniques. Metabolic syndrome also has deleterious effects on the pancreas, kidney, gastrointestinal tract, and ovaries, including increased risk for several malignancies. Metabolic syndrome is associated with cerebral infarcts, best evaluated with MRI, and has been linked with cognitive decline. ©RSNA, 2024 Test Your Knowledge questions for this article are available in the supplemental material. See the invited commentary by Pickhardt in this issue.


Asunto(s)
Enfermedades Cardiovasculares , Enfermedad de la Arteria Coronaria , Diabetes Mellitus Tipo 2 , Resistencia a la Insulina , Síndrome Metabólico , Humanos , Síndrome Metabólico/diagnóstico por imagen , Síndrome Metabólico/complicaciones , Diabetes Mellitus Tipo 2/complicaciones , Enfermedades Cardiovasculares/diagnóstico por imagen , Factores de Riesgo
15.
Acad Radiol ; 31(6): 2627-2633, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38403479

RESUMEN

The discussion and critical appraisal of medical literature in a group setting has been incorporated in health care education for over a century and remains one of the structured didactic activities in Accreditation Council for Graduate Medical Education radiology residency educational requirements. The panel members of the "Radiology Journal Club: Best Practice from Across the Country" Task Force of the Association of University Radiologists Radiology Research Alliance have collated best practices from radiology and other medical specialties to help radiology departments to establish or resume journal club as part of their residency or fellowship educational program. Key components include a leadership team to designate mentors, facilitators, and ad hoc content experts; to establish the scope, goals and learning objectives; to identify the target audience and level of faculty and trainee involvement; and establish appropriate meeting frequency. Providing relevant and easily accessible resources, mentoring and other preparatory materials can build trainee skill in critical appraisal of the medical literature, foster innovation, and advance radiological knowledge in this ever-evolving discipline.


Asunto(s)
Educación de Postgrado en Medicina , Internado y Residencia , Publicaciones Periódicas como Asunto , Radiología , Radiología/educación , Humanos , Educación de Postgrado en Medicina/métodos
16.
AJR Am J Roentgenol ; 222(3): e2329778, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37991334

RESUMEN

BACKGROUND. The higher spatial resolution and image contrast for iodine-containing tissues of photon-counting detector (PCD) CT may address challenges in evaluating small calcified vessels when performing lower extremity CTA by energy-integrating detector (EID) CTA. OBJECTIVE. The purpose of the study was to compare the evaluation of infrapopliteal vasculature between lower extremity CTA performed using EID CT and PCD CT. METHODS. This prospective study included 32 patients (mean age, 69.7 ± 11.3 [SD] years; 27 men, five women) who underwent clinically indicated lower extremity EID CTA between April 2021 and March 2022; participants underwent investigational lower extremity PCD CTA later the same day as EID CTA using a reduced IV contrast media dose. Two radiologists independently reviewed examinations in two sessions, each containing a random combination of EID CTA and PCD CTA examinations; the readers assessed the number of visualized fibular perforators, characteristics of stenoses at 11 infrapopliteal segmental levels, and subjective arterial sharpness. RESULTS. Mean IV contrast media dose was 60.0 ± 11.0 (SD) mL for PCD CTA versus 139.6 ± 11.8 mL for EID CTA (p < .001). The number of identified fibular perforators per lower extremity was significantly higher for PCD CTA than for EID CTA for reader 1 (R1) (mean ± SD, 6.4 ± 3.2 vs 4.2 ± 2.4; p < .001) and reader 2 (R2) (8.8 ± 3.4 vs 7.6 ± 3.3; p = .04). Reader confidence for assessing stenosis was significantly higher for PCD CTA than for EID CTA for R1 (mean ± SD, 82.3 ± 20.3 vs 78.0 ± 20.2; p < .001) but not R2 (89.8 ± 16.7 vs 90.6 ± 7.1; p = .24). The number of segments per lower extremity with total occlusion was significantly lower for PCD CTA than for EID CTA for R2 (mean ± SD, 0.5 ± 1.3 vs 0.9 ± 1.7; p = .04) but not R1 (0.6 ± 1.3 vs 1.0 ± 1.5; p = .07). The number of segments per lower extremity with clinically significant nonocclusive stenosis was significantly higher for PCD CTA than for EID CTA for R1 (mean ± SD, 2.2 ± 2.2 vs 1.6 ± 1.7; p = .01) but not R2 (1.1 ± 2.0 vs 1.1 ± 1.4; p = .89). Arterial sharpness was significantly greater for PCD CTA than for EID CTA for R1 (mean ± SD, 3.2 ± 0.5 vs 1.8 ± 0.5; p < .001) and R2 (3.2 ± 0.4 vs 1.7 ± 0.8; p < .001). CONCLUSION. PCD CTA yielded multiple advantages relative to EID CTA for visualizing small infrapopliteal vessels and characterizing associated plaque. CLINICAL IMPACT. The use of PCD CTA may improve vascular evaluation in patients with peripheral arterial disease.


Asunto(s)
Medios de Contraste , Fotones , Masculino , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Estudios Prospectivos , Constricción Patológica , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/métodos , Extremidad Inferior/diagnóstico por imagen
17.
Int J Cardiovasc Imaging ; 40(1): 5-14, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37948028

RESUMEN

The 2022 AHA/ACC Guidelines for the Diagnosis and Management of Aortic Disease introduced important updates for managing thoracic aorta aortic disease (TAD). In particular, the Guidelines underscore multimodality imaging's role in diagnosis, risk assessment, and monitoring of patients with TAD. This commentary aims to distill key imaging aspects from the Guidelines to provide a concise reference for the cardiovascular imaging community. Primary areas of focus include: (1) The importance of imagers in the multidisciplinary TAD care team, (2) Appropriate imaging techniques along with their strengths and weaknesses, (3) Aortic measurement methods and how aortic size and growth should contribute to TAD risk assessment, (4) Imaging evaluation of acute aortic syndrome. We have also highlighted several areas of ongoing uncertainty and confusion, specifically related to aortic measurement techniques and descriptive terminology. Finally, a perspective on the future of TAD imaging is discussed with a focus on advanced imaging tools and techniques as well as the potential role of artificial intelligence.


Asunto(s)
Aneurisma de la Aorta Torácica , Enfermedades de la Aorta , Humanos , Inteligencia Artificial , Valor Predictivo de las Pruebas , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/terapia , Imagen Multimodal , América del Norte , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/terapia , Aorta Torácica/diagnóstico por imagen
18.
J Cardiovasc Comput Tomogr ; 18(1): 56-61, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37945454

RESUMEN

BACKGROUND: To quantify differences in coronary artery stenosis severity in patients with calcified lesions between conventional energy-integrating detector (EID) CT and ultra-high-resolution (UHR) photon-counting-detector (PCD) CT. METHODS: Patients undergoing clinically indicated coronary CT angiography were prospectively recruited and scanned first on an EID-CT (SOMATOM Force, Siemens Healthineers) and then a PCD-CT (NAEOTOM Alpha, Siemens Healthineers) on the same day. EID-CT was performed with standard mode (192 â€‹× â€‹0.6 â€‹mm detector collimation) following our clinical protocol. PCD-CT scans were performed under UHR mode (120 â€‹× â€‹0.2 â€‹mm detector collimation). For each patient, left main, left anterior descending, right coronary artery, and circumflex were reviewed and the most severe stenosis from dense calcification for each coronary was quantified using commercial software. Additionally, each measured stenosis was assigned a severity category based on percent diameter stenosis, and changes in severity category across EID-CT and PCD-CT were assessed. RESULTS: A total of 23 patients were enrolled, with 34 coronary artery stenoses analyzed. Stenosis was significantly reduced in PCD-CT compared to EID-CT (p â€‹< â€‹0.001), resulting in an average of 11% (SD â€‹= â€‹11%) reduction in percent diameter stenosis. Among the 34 lesions, 15 changed in stenosis severity category: 3 went from moderate to minimal, 1 from moderate to mild, 9 from mild to minimal, and 2 from minimal to mild with the use of PCD-CT compared to EID-CT. CONCLUSION: Use of UHR PCD-CT decreased percent diameter stenosis by an average of 11% relative to EID-CT, resulting in 13 of 34 stenoses being downgraded in stenosis severity category, potentially sparing patients from unnecessary intervention.


Asunto(s)
Calcinosis , Estenosis Coronaria , Humanos , Constricción Patológica , Fantasmas de Imagen , Valor Predictivo de las Pruebas , Tomografía Computarizada por Rayos X/métodos , Estenosis Coronaria/diagnóstico por imagen , Calcinosis/diagnóstico por imagen
19.
J Am Coll Radiol ; 20(11S): S351-S381, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-38040460

RESUMEN

Pediatric heart disease is a large and diverse field with an overall prevalence estimated at 6 to 13 per 1,000 live births. This document discusses appropriateness of advanced imaging for a broad range of variants. Diseases covered include tetralogy of Fallot, transposition of great arteries, congenital or acquired pediatric coronary artery abnormality, single ventricle, aortopathy, anomalous pulmonary venous return, aortopathy and aortic coarctation, with indications for advanced imaging spanning the entire natural history of the disease in children and adults, including initial diagnosis, treatment planning, treatment monitoring, and early detection of complications. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.


Asunto(s)
Enfermedad de la Arteria Coronaria , Cardiopatías , Adulto , Niño , Humanos , Diagnóstico Diferencial , Diagnóstico por Imagen/métodos , Sociedades Médicas , Estados Unidos
20.
Radiology ; 309(1): e230803, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37847140

RESUMEN

In 1971, the first patient CT examination by Ambrose and Hounsfield paved the way for not only volumetric imaging of the brain but of the entire body. From the initial 5-minute scan for a 180° rotation to today's 0.24-second scan for a 360° rotation, CT technology continues to reinvent itself. This article describes key historical milestones in CT technology from the earliest days of CT to the present, with a look toward the future of this essential imaging modality. After a review of the beginnings of CT and its early adoption, the technical steps taken to decrease scan times-both per image and per examination-are reviewed. Novel geometries such as electron-beam CT and dual-source CT have also been developed in the quest for ever-faster scans and better in-plane temporal resolution. The focus of the past 2 decades on radiation dose optimization and management led to changes in how exposure parameters such as tube current and tube potential are prescribed such that today, examinations are more customized to the specific patient and diagnostic task than ever before. In the mid-2000s, CT expanded its reach from gray-scale to color with the clinical introduction of dual-energy CT. Today's most recent technical innovation-photon-counting CT-offers greater capabilities in multienergy CT as well as spatial resolution as good as 125 µm. Finally, artificial intelligence is poised to impact both the creation and processing of CT images, as well as automating many tasks to provide greater accuracy and reproducibility in quantitative applications.


Asunto(s)
Inteligencia Artificial , Tomografía Computarizada por Rayos X , Humanos , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X/métodos , Cintigrafía , Fantasmas de Imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA