Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
3.
Indian J Ophthalmol ; 71(8): 2962-2966, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37530265

RESUMEN

Purpose: To compare the axial length (AL) and corneal diameter between glaucomatous eye (GE) and fellow normal eye (NE) in patients with unilateral congenital glaucoma and to obtain a normative database for ocular growth among Indian children below 3 years of age. Methods: Retrospective longitudinal study. Patients who had a follow-up of 3 years from diagnosis with ocular biometry parameters being recorded at least thrice (once a year) and fellow eye being normal were included. Data collected were age, gender, intraocular pressure (IOP), AL, corneal diameter, optic disc findings, diagnosis, and surgery details. Results: Eleven patients were analyzed. All GE underwent combined trabeculotomy with trabeculectomy. Mean (SD) baseline IOP, AL, and corneal diameter were 17.1 (6.7) mmHg, 18.9 (1.1) mm and 12 (0.91) mm in GE, and 11.1 (3.8) mmHg, 17.8 (0.44) mm, and 10.5 (0.58) mm in NE, respectively. Increase in AL was 3.1 mm in the first year followed by 0.6 mm in second year and 0.4 mm in third year in GE compared to 2.6, 0.6, and 0.5 mm in NE, respectively. Corneal diameter increased by 1.1 mm in GE in the first year and remained stable thereafter compared to 0.7 mm in first year followed by 0.3 mm in second year and stable thereafter in NE. The percentage of success was 73% at 3 years. Conclusion: Axial length and corneal diameter were higher in GE than NE at all-time points. With prompt intervention, the growth curve of the GE was made parallel to that of NE.


Asunto(s)
Glaucoma , Trabeculectomía , Niño , Humanos , Estudios Retrospectivos , Estudios Longitudinales , Córnea , Glaucoma/diagnóstico , Glaucoma/cirugía , Presión Intraocular , Biometría , Resultado del Tratamiento , Estudios de Seguimiento
5.
J Glaucoma ; 31(5): 356-360, 2022 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-35220386

RESUMEN

Gonioscopy is an important part of glaucoma diagnosis and management. Imaging and documentation of the anterior chamber angle has been previously performed using slit-lamp-assisted photography or using smartphones with or without an attached macro lens. Smartphones have transformed ophthalmic imaging by virtue of their availability, easy use, and portability. In this report, the authors aim to demonstrate gonio-imaging using a smartphone attached with an intraocular lens which behaves like a macro lens. With the patient in a sitting position or in the supine position, a goniolens is placed on the patient's cornea. A smartphone with a 10 D intraocular lens attachment over its camera is used to take images or videos of the anterior chamber angle with high magnification. This imaging modality is cost-effective and can be used for screening and photographic documentation of the angle, and can be of immense benefit, especially in primary health care centers.


Asunto(s)
Lentes Intraoculares , Teléfono Inteligente , Análisis Costo-Beneficio , Gonioscopía , Humanos , Presión Intraocular , Fotograbar
6.
Ophthalmol Glaucoma ; 4(6): 616, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34823816

Asunto(s)
Disco Óptico , Humanos
7.
Am J Ophthalmol ; 230: 188-199, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-33992616

RESUMEN

PURPOSE: To estimate the heritability of ocular biometric and anterior chamber morphologic parameters and to determine predictors of angle closure concordance in South Indian probands with angle closure and their siblings DESIGN: Prospective observational cohort study METHODS: Subjects received a standardized ophthalmic examination, A-scan ultrasonography, pachymetry, and anterior segment optical coherence tomography (ASOCT) imaging. Heritability was calculated using residual correlation coefficients adjusted for age, sex, and home setting. Concordant sibling pairs were defined as both proband and sibling with angle closure. Predictors of angle closure concordance among siblings were calculated using multivariable logistic regression models. RESULTS: A total of 345 sibling pairs participated. All anterior chamber parameters were highly heritable (P < .001 for all). Similarly, all iris parameters, axial length, lens thickness (LT), central corneal thickness, anterior lens curvature, lens vault (LV), spherical equivalent, and intraocular pressure were moderately to highly heritable (P < .004 for all). LV and LT were more heritable among concordant siblings (P < .05 for both). In contrast, ASOCT angle parameters had statistically insignificant heritability estimates. In multivariable analyses, siblings older than their probands were more likely to be concordant for angle closure (OR 1.05, 95% CI 1.01, 1.09; P = .02) and siblings with deeper anterior chamber depths (ACDs) compared to their proband were less likely to be concordant for angle closure (OR 0.74, 95% CI 0.64, 0.86; P < .001). CONCLUSIONS: Iris, anterior chamber, and lens parameters may be heritable whereas angle parameters were not. LT and LV may play important roles in the pathogenesis of angle closure. Siblings who are older or have a shallower ACD may need more careful disease monitoring.


Asunto(s)
Glaucoma de Ángulo Cerrado , Hermanos , Biometría , Glaucoma de Ángulo Cerrado/diagnóstico , Glaucoma de Ángulo Cerrado/genética , Gonioscopía , Humanos , Tonometría Ocular
10.
Indian J Ophthalmol ; 68(3): 471-474, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32057005

RESUMEN

Purpose: To assess the quality and accuracy of glaucoma referrals from ophthalmologist. Methods: Retrospective review of patients chart with referral letter to a tertiary glaucoma center between January and December 2017. Patients aged <16 years, lens-induced glaucoma, uveitic glaucoma, and glaucoma following retinal and corneal surgery were excluded. Results: A total of 184 patients referred by 55 ophthalmologists were included. Mean patient age (SD) was 57.8 ± 14 years. Intraocular pressure was not documented in the referral letter in 113 (61%) patients, gonioscopy in 174 (95%) patients, disc findings in 149 (81%) patients, and visual fields in 175 (95%) patients. Thirteen (37%) of the 35 patients referred as open angle glaucoma were found to have angle closure glaucoma. Pseudoexfoliation glaucoma was diagnosed in 29 (16%) patients, of which 18 were missed by the referring ophthalmologist. Conclusion: In our study >90% of referral letter did not have the essential parameters. A standard template for glaucoma referral is suggested, which will help the patient to get better transfer of care.


Asunto(s)
Glaucoma/diagnóstico , Gonioscopía/métodos , Presión Intraocular/fisiología , Indicadores de Calidad de la Atención de Salud , Derivación y Consulta , Centros de Atención Terciaria , Campos Visuales/fisiología , Femenino , Estudios de Seguimiento , Glaucoma/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tomografía de Coherencia Óptica/métodos , Tonometría Ocular/métodos
11.
Am J Ophthalmol ; 205: 106-114, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31082348

RESUMEN

PURPOSE: To evaluate the demographic, clinical, and socioeconomic factors associated with variation in the quality of life (QOL) in caregivers of children with primary congenital glaucoma (PCG) in south India. DESIGN: Cross-sectional survey. METHODS: Caregivers of children younger than 18 with diagnosed PCG were prospectively enrolled at Aravind Eye Hospital in Madurai and Coimbatore, India. Participants completed 2 questionnaires, the PHQ-9 (9-item Patient Health Questionnaire) and the CarCGQoL (Caregivers Congenital Glaucoma QOL Questionnaire). Clinical, demographic, and socioeconomic data were obtained for each child-caregiver dyad. Rasch-calibrated scores were calculated for patient-reported outcome measures. Spearman correlation and linear regression were used to analyze data to determine associations with caregiver QOL. RESULTS: There were 70 caregivers (mean age 32.1, 77.1% female) of 70 children with PCG (mean age 7.7, 37.1% female) included in the study. In univariate and multivariable analyses, child's age (ß = -0.04; 95% confidence interval, -0.08 to -0.01) and duration of disease (ß = - 0.03; 95% confidence interval, -0.07 to -0.01) were the only factors associated with CarCGQoL. Survey items related to anger, self-confidence, irritability, appetite, and interest in leisure activities had the lowest scores. There was a negative correlation between CarCGQoL and PHQ-9 scores (r = -0.66, P < .01), indicating that worse caregiver QOL was significantly correlated with more depressive symptoms. CONCLUSION: This study identified traits associated with QOL decline, as well as the QOL issues most likely to affect caregivers of children with PCG in south India. Findings from this study may be important for designing interventions to improve caregivers' QOL, thereby maximizing their ability to care for children with PCG.


Asunto(s)
Adaptación Psicológica/fisiología , Cuidadores/psicología , Glaucoma/congénito , Psicometría/métodos , Calidad de Vida , Adulto , Niño , Preescolar , Estudios Transversales , Femenino , Estudios de Seguimiento , Glaucoma/rehabilitación , Humanos , Lactante , Masculino , Estudios Retrospectivos , Encuestas y Cuestionarios
12.
J Glaucoma ; 28(4): 318-320, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30946277

RESUMEN

PURPOSE: To compare the effect of mannitol in reducing intraocular pressure (IOP) in vitrectomized and nonvitrectomized eyes. MATERIALS AND METHODS: Prospective comparative case study. Eyes with IOP≥40 mm Hg were included. Eyes which are vitrectomized and silicon oil filled were classified as group 1, and nonvitrectomized open-angle eyes were classified as group 2. Mannitol (20%, 1 g/kg) was administered intravenously over 30 minutes, and IOP was recorded at 30 minutes interval till 2 hours and at the third and fourth hour from the start of mannitol. RESULTS: Thirty eyes (patients) were recruited in each group. Mean (SD) IOP reduced from 48.5±5.2 to 43.7±8 at 30 minutes, 40.7±8.4 at 60 minutes, 37.3±9.6 at 90 minutes, 35.6±10.4 at 2 hours, 34±10.7 at 3 hours, and 33±11.2 mm Hg at 4 hours in group 1, and from 48.9±6.5 to 43.2±8.6 at 30 minutes, 40.2±7.8 at 60 minutes, 36.7±7.3 at 90 minutes, 35.1±7.7 at 2 hours, 34.2±8.8 at 3 hours, and 35.7±9.4 mm Hg at 4 hours in group 2. There was a significant reduction in IOP at each time point compared with baseline in both the groups (P<0.001). There was no significant difference in IOP between the 2 groups at each time point. CONCLUSION: Mannitol reduces IOP significantly in both vitrectomized and nonvitrectomized eyes.


Asunto(s)
Diuréticos Osmóticos/administración & dosificación , Presión Intraocular/efectos de los fármacos , Manitol/administración & dosificación , Desprendimiento de Retina/cirugía , Vitrectomía , Adulto , Anciano , Endotaponamiento , Femenino , Glaucoma de Ángulo Abierto/fisiopatología , Humanos , Infusiones Intravenosas , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Aceites de Silicona/administración & dosificación , Tonometría Ocular
14.
Indian J Ophthalmol ; 67(2): 233-238, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30672476

RESUMEN

PURPOSE: To report the intermediate-term safety and efficacy of Aurolab aqueous drainage implant (AADI) in patients with glaucoma. METHODS: Retrospective review of patients who underwent AADI between January 2013 and December 2016. Patients aged >16 years and with a minimum follow-up of 6 months were included. Success was defined as complete when the intraocular pressure was ≥6 and ≤21 mmHg without antiglaucoma medication and as qualified if those requiring additional antiglaucoma medications were included. RESULTS: The study included 55 patients (55 eyes) with a mean age ± standard deviation (SD) of 47.3 ± 18.1 years with a mean follow-up of 16.7 ± 11.4 months. Mean intraocular pressure reduced from 30.8 ± 11.1 mmHg to 13.1 ± 4.7, 14.1 ± 4.8, 15.7 ± 2.5 (P < 0.001) mmHg at 6 months, 1 year, and 2 years, respectively. The mean number of antiglaucoma medications reduced from 3.4 ± 1 to 0.8 ± 1.2, 0.7 ± 1.1, 0.8 ± 1 (P < 0.001) at 6 months, 1 year, and 2 years, respectively. The cumulative probability of complete and qualified success was 62% and 100% at 6 months, 54% and 92% at 1 year, and 43% and 88% at 2 years, respectively. Four patients failed during the follow-up period. Postoperative complication occurred in 28 eyes (51%), of which 17 eyes (31%) required intervention. CONCLUSION: AADI is a safe and effective treatment for the control of intraocular pressure in patients with glaucoma.


Asunto(s)
Implantes de Drenaje de Glaucoma , Glaucoma/cirugía , Presión Intraocular/fisiología , Agudeza Visual/fisiología , Adolescente , Adulto , Anciano , Femenino , Estudios de Seguimiento , Glaucoma/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Tiempo , Tonometría Ocular , Trabeculectomía , Resultado del Tratamiento , Adulto Joven
18.
Indian J Ophthalmol ; 66(1): 134-136, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29283142

RESUMEN

A 26-year-old male presented with superior filtering bleb with scleral thinning, dislocated lens, and hypotony in both the eyes. His cornea was normal without any sign of ectasia, and there was no history of recurrent redness, trauma, or surgery in either eye. Anterior segment optical coherence tomography did not reveal communicating fistula between the anterior chamber and subconjunctival space. Physical examination and blood investigations did not reveal any systemic association. He was diagnosed to have spontaneous filtering bleb, which is a rare condition observed with ocular or systemic abnormalities.


Asunto(s)
Segmento Anterior del Ojo/diagnóstico por imagen , Desplazamiento del Cristalino/diagnóstico , Subluxación del Cristalino/diagnóstico , Esclerótica/patología , Tomografía de Coherencia Óptica/métodos , Adulto , Desplazamiento del Cristalino/complicaciones , Humanos , Subluxación del Cristalino/complicaciones , Masculino
19.
Ophthalmology ; 125(3): 345-351, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29096997

RESUMEN

PURPOSE: To determine whether laser peripheral iridotomy (LPI) location affects postoperative dysphotopsia symptoms. DESIGN: Multicenter, randomized, prospective, single-masked trial. PARTICIPANTS: Five hundred fifty-nine South Indian patients 30 years of age or older diagnosed as primary angle-closure suspects (PACSs) or with primary angle closure (PAC) or primary angle-closure glaucoma (PACG) in both eyes. METHODS: Patients were randomized to either bilateral superior or bilateral nasal/temporal LPI. Occurrence of new visual disturbances was evaluated before and 2 weeks after LPI using a questionnaire based on the 7-item dysphotopsia symptoms described by Spaeth et al. MAIN OUTCOME MEASURES: New-onset dysphotopsia symptoms. RESULTS: Superior LPI (n = 285) and nasal/temporal LPI (n = 274) patients were matched for age (P = 0.6), gender (P = 0.7), and distribution of PACS versus PAC or PACG (P = 0.7). Similar initial laser energy settings were used in both groups (P = 0.3), although superior LPIs required more shots (P = 0.006) and greater total energy (P < 0.001) than nasal/temporal LPIs. No significant differences in postoperative anterior chamber reaction (P = 0.7) or LPI area (P = 0.9) were noted between the 2 groups. No group differences were noted regarding the proportion of patients demonstrating 1 or more dysphotopsia symptoms before LPI (15.8% for superior vs. 13.9% for nasal/temporal; P = 0.1) or any individual dysphotopsia symptom (P > 0.2 for all). After LPI, 8.9% of all patients reported 1 or more new symptoms, the most common consisting of linear dysphotopsias, glare, and blurring in 2.7%, 4.3%, and 4.3% of patients, respectively. Patients undergoing superior LPI were not more likely to describe the new onset of 1 or more dysphotopsia symptoms as compared with patients undergoing nasal/temporal LPI (8.4% vs. 9.5%; P = 0.7), nor did the frequency of any new individual symptoms differ by group (P ≥ 0.3 for all). In multivariate logistic regression analysis, neither LPI location nor LPI area nor total laser energy predicted higher odds of new postoperative dysphotopsias (P > 0.1 for all). CONCLUSIONS: Laser peripheral iridotomy likely is safe with respect to visual dysphotopsias regardless of location, LPI size, and amount of laser energy used.


Asunto(s)
Glaucoma de Ángulo Cerrado/cirugía , Presión Intraocular/fisiología , Iridectomía/métodos , Iris/cirugía , Terapia por Láser/instrumentación , Láseres de Estado Sólido/uso terapéutico , Agudeza Visual , Femenino , Estudios de Seguimiento , Glaucoma de Ángulo Cerrado/diagnóstico , Glaucoma de Ángulo Cerrado/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Método Simple Ciego , Resultado del Tratamiento
20.
J Glaucoma ; 25(7): 590-7, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-26580479

RESUMEN

OBJECTIVE: To describe and evaluate the performance of an automated CAD system for detection of glaucoma from color fundus photographs. DESIGN AND SETTING: Color fundus photographs of 2252 eyes from 1126 subjects were collected from 2 centers: Aravind Eye Hospital, Madurai and Coimbatore, India. The images of 1926 eyes (963 subjects) were used to train an automated image analysis-based system, which was developed to provide a decision on a given fundus image. A total of 163 subjects were clinically examined by 2 ophthalmologists independently and their diagnostic decisions were recorded. The consensus decision was defined to be the clinical reference (gold standard). Fundus images of eyes with disagreement in diagnosis were excluded from the study. The fundus images of the remaining 314 eyes (157 subjects) were presented to 4 graders and their diagnostic decisions on the same were collected. The performance of the system was evaluated on the 314 images, using the reference standard. The sensitivity and specificity of the system and 4 independent graders were determined against the clinical reference standard. RESULTS: The system achieved an area under receiver operating characteristic curve of 0.792 with a sensitivity of 0.716 and specificity of 0.717 at a selected threshold for the detection of glaucoma. The agreement with the clinical reference standard as determined by Cohen κ is 0.45 for the proposed system. This is comparable to that of the image-based decisions of 4 ophthalmologists. CONCLUSIONS AND RELEVANCE: An automated system was presented for glaucoma detection from color fundus photographs. The overall evaluation results indicated that the presented system was comparable in performance to glaucoma classification by a manual grader solely based on fundus image examination.


Asunto(s)
Diagnóstico por Computador , Técnicas de Diagnóstico Oftalmológico , Glaucoma de Ángulo Abierto/diagnóstico , Disco Óptico/patología , Enfermedades del Nervio Óptico/diagnóstico , Fotograbar/instrumentación , Reacciones Falso Positivas , Femenino , Glaucoma de Ángulo Abierto/clasificación , Humanos , India , Presión Intraocular/fisiología , Masculino , Hipertensión Ocular/clasificación , Hipertensión Ocular/diagnóstico , Enfermedades del Nervio Óptico/clasificación , Valor Predictivo de las Pruebas , Curva ROC , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA