Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 238
Filtrar
1.
Materials (Basel) ; 17(9)2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38730928

RESUMEN

The aim of this paper was to evaluate the fracture resistance of 3D-printed zirconia occlusal veneers (OVs) of different thicknesses and supported by different abutment materials. Materials and Methods: The standard OV of a natural molar was prepared and digitized using a laboratory 3D scanner. The resulting digital tooth abutment was milled either using cobalt-chromium (CoCr) or a fiber-reinforced composite (FRC). All the abutments were digitized and standardized OVs (30° tilt of all the cusps) designed with 0.4 mm, 0.6 mm, or 0.8 mm wall thicknesses. The OVs were fabricated using either the Programill PM7 milling device (Ivoclar Vivadent, PM) or one of two 3D zirconia printers, Cerafab 7500 (Lithoz, LC) or Zipro-D (AON, ZD). The ZD samples were only tested on CoCr abutments. The completed OVs were luted to their abutments and subjected to artificial aging, consisting of thermocycling and chewing simulation before fracture testing with a steel sphere (d = 8 mm) as an antagonist with three contact points on the occlusal OV surface. Besides the total fracture resistance Fu,tot, the lowest contact force Fu,cont leading to the local fracture of a cusp was of interest. The possible effects of the factors fabrication approach, wall thickness, and abutment material were evaluated using ANOVA (α = 0.05; SPSS Ver.28). Results: The total fracture resistance/contact forces leading to failure ranged from Fu,tot = 416 ± 83 N/Fu,cont = 140 ± 22 N for the 0.4 mm OVs fabricated using LC placed on the FRC abutments to Fu,tot = 3309 ± 394 N (ZD)/Fu,cont = 1206 ± 184 N (PM) for the 0.8 mm thick OVs on the CoCr abutments. All the factors (the fabrication approach, abutment material, and OV wall thickness) had an independent effect on Fu,tot as well as Fu,cont (p < 0.032). In pairwise comparisons for Fu,tot of the OVs luted to the CoCr abutments, the ZD samples statistically outperformed the LC- and PM-fabricated teeth irrespective of the thickness (p < 0.001). Conclusions: Within the limitations of this study, the printed occlusal veneers exhibited comparable fracture resistances to those of the milled variants. However, more resilient abutments (FRC as a simulation of dentine) as well as a thinner wall thickness led to reduced OV fracture resistance, suggesting that 0.4 mm thick zirconia OVs should not be unreservedly used in every clinical situation.

2.
Materials (Basel) ; 17(9)2024 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-38730965

RESUMEN

This study aimed to assess the suitability of printed zirconia (ZrO2) for adhesive cementation compared to milled ZrO2. Surface conditioning protocols and disinfection effects on bond strength were also investigated. ZrO2 discs (n = 14/group) underwent either alumina (Al2O3) airborne particle abrasion (APA; 50 µm, 0.10 MPa) or tribochemical silicatisation (TSC; 110 µm Al2O3, 0.28 MPa and 110 µm silica-modified Al2O3, 0.28 MPa), followed by disinfection (1 min immersion in 70% isopropanol, 15 s water spray, 10 s drying with oil-free air) for half of the discs. A resin cement containing 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP) was used for bonding (for TSC specimens after application of a primer containing silane and 10-MDP). Tensile bond strength was measured after storage for 24 h at 100% relative humidity or after 30 days in water, including 7500 thermocycles. Surface conditioning significantly affected bond strength, with higher values for TSC specimens. Ageing and the interaction of conditioning, disinfection and ageing also impacted bond strength. Disinfection combined with APA mitigated ageing-related bond strength decrease but exacerbated it for TSC specimens. Despite these effects, high bond strengths were maintained even after disinfection and ageing. Adhesive cementation of printed ZrO2 restorations exhibited comparable bond strengths to milled ZrO2, highlighting its feasibility in clinical applications.

3.
Bioengineering (Basel) ; 11(4)2024 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-38671815

RESUMEN

The efficacy of retainers is a pivotal concern in orthodontic care. This study examined the biomechanical behaviour of retainers, particularly the influence of retainer stiffness and tooth resilience on force transmission and stress distribution. To do this, a finite element model was created of the lower jaw from the left to the right canine with a retainer attached on the oral side. Three levels of tooth resilience and variable retainer bending stiffness (influenced by retainer type, retainer diameter, and retainer material) were simulated. Applying axial or oblique (45° tilt) loads on a central incisor, the force transmission increased from 2% to 65% with increasing tooth resilience and retainer stiffness. Additionally, a smaller retainer diameter reduced the uniformity of the stress distribution in the bonding interfaces, causing concentrated stress peaks within a small field of the bonding area. An increase in retainer stiffness and in tooth resilience as well as a more oblique load direction all lead to higher overall stress in the adhesive bonding area associated with a higher risk of retainer bonding failure. Therefore, it might be recommended to avoid the use of retainers that are excessively stiff, especially in cases with high tooth resilience.

4.
J Prosthodont Res ; 2024 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-38684407

RESUMEN

PURPOSE: This study investigated the fracture resistance of 0.5-mm-thick restorations for minimally invasive therapy. Anterior partial-coverage crowns composed of three-dimensional (3D)-printed 3-mol% yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP; Lithacon 3Y210, Lithoz) and 3D-printed composite (Varseo Smile Crown plus, Bego) were compared with a control group made from milled 3Y-TZP (Cercon ht, DentsplySirona). METHODS: Three groups each with 27 restorations were produced. For milled 3Y-TZP partial-coverage crowns, drill compensation was needed so the milling bur could access the inner surface at the incisal edge. Restoration fit was verified by cross-sectioning 12 specimens in each group. The remaining 15 restorations were sandblasted (Al2O3, 0.1 MPa) and adhesively cemented (Panavia SA, Kuraray) onto CoCr teeth. Static load-to-failure tests were performed. The load was induced on the incisal edge. The forces needed to fracture the specimens were analyzed using the Welch analysis of variance and post hoc Dunnet-T3 tests. The Weibull parameters were also calculated. RESULTS: Drill compensation increased cement thickness at the loading area by 200 µm in milled 3Y-TZP restorations compared with the 3D-printed partial-coverage crowns. Fracture resistance was the highest in 3D-printed 3Y-TZP restorations (1570±661N) followed by milled 3Y-TZP (886±164N) and 3D-printed composite partial-coverage crowns (570±233 N). Milled 3Y-TZP was associated with a substantially higher Weibull modulus (m=6) than the 3D-printed materials (m=2), suggesting greater reliability. CONCLUSIONS: Fracture resistance increased with tighter fit, demonstrating the benefit of the geometric freedom associated with 3D-printing. Future research should focus on making 3D-printed 3Y-TZP more reliable to increase its safety in clinical use.

5.
Int J Prosthodont ; 37(2): 157-165, 2024 04 22.
Artículo en Inglés | MEDLINE | ID: mdl-38648164

RESUMEN

PURPOSE: To generate data on the long-term survival of metal-ceramic resin-bonded fixed partial dentures (RBFPDs). MATERIALS AND METHODS: A total of 89 patients received 94 RBFPDs, 5 of whom (women n = 1; men n = 4) received 2 RBFPDs each. All RBFPDs were fabricated as two-retainer end-abutment metal-ceramic restorations. Clinical follow-ups were performed 6 months after cementation and then annually thereafter. The mean observation time was 7.5 years. Cox regression was performed to test the effects of the variables: gender, location, arch, design, use of rubber dam, and adhesive luting system. Survival and success were calculated using Kaplan-Meier curves. As a secondary objective, patient and dentist satisfaction with the esthetics and function of the RBFPDs was evaluated. The significance level was set at α = .05 for all calculations. RESULTS: Estimated Kaplan-Meier failure-free survival was 97.5% (standard error [SE] 1.7) after 5 years and 83.3% (SE 5.3) after 10 years. Calculated intervention-free survival (success) was 90.1% (SE 3.4) after 5 years and 65.5% (SE 6.7) after 10 years. Debonding-free survival was 92.6% (SE 2.9) after 5 years and 80.6% (SE 5.4) after 10 years. Cox regression revealed that none of the four tested variables had a significant effect on the incidence of complications in RBFPDs. Patient and dentist satisfaction with RBFPD esthetics and function was consistently high throughout the observation period. CONCLUSIONS: Within the limitations of an observational study, RBFPDs achieved clinically successful outcomes over a mean observational period of 7.5 years.


Asunto(s)
Dentadura Parcial Fija con Resina Consolidada , Humanos , Femenino , Masculino , Persona de Mediana Edad , Fracaso de la Restauración Dental , Aleaciones de Cerámica y Metal/química , Adulto , Diseño de Dentadura , Satisfacción del Paciente , Anciano , Estética Dental
6.
J Prosthet Dent ; 2024 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-38480016

RESUMEN

STATEMENT OF PROBLEM: Precise data are a prerequisite for accurately fitting restorations. Therefore, intraoral scanners have to be reliable. Data on differences between the same model of intraoral scanning systems are lacking. PURPOSE: This in vitro study evaluated differences in the scanning accuracy of a partially edentulous maxilla between combinations of new intraoral scanners of a single model from the same manufacturer (Primescan; Dentsply Sirona) and several calibration aids. MATERIAL AND METHODS: The in vitro reference model simulated a maxilla with 6 prepared teeth for a complete arch fixed partial denture. Five precision ceramic balls were used to detect dimensional deviation between the reference model and the scan. Distances were divided into 4 categories, from short distances between 2 neighboring precision balls to the cross-arch distance with the scan path comprising all 5 balls. For each combination of 4 new intraoral scanners and their respective calibration aids, 12 model registrations were generated. The data were statistically analyzed using ANOVA (α=.05). RESULTS: Distance deviations increased with increasing scan path length and were significantly affected by the covariates "scanner" (P≤.023) and, for 3 of 4 distance categories, the "calibration aid" (short, medium, and long distances: P≤.013). For short and medium distances, acceptable scanning results were achieved for all test groups. The largest deviation was 539 µm for the cross-arch distance. CONCLUSIONS: Scanning accuracy depends on the scanner and the calibration aid used, in particular, for spans exceeding a single quadrant.

7.
Clin Oral Investig ; 28(2): 145, 2024 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-38351386

RESUMEN

OBJECTIVES: To compare the strength and reliability of 3D-printed 3Y-TZP zirconia manufactured with various printing orientations and staining. MATERIALS AND METHODS: A total of one-hundred cylindrical zirconia specimens were designed and fabricated using 3D printing and processed according to ISO 6872 standards. Of these specimens, 80 were 3D printed using the new ZIPRO-D (ZD) 3D ceramic printer. In this ZD group, 60 specimens were printed in a vertical orientation and were either stained after debinding (ZD1, x-orientation, n = 20) or not stained (ZD2, x-orientation, n = 20; ZD3, y-orientation, n = 20) and the remaining 20 specimens out of n = 80 were printed in a horizontal orientation (ZD4). Further 20 specimens out of the entire sample N = 100 were printed vertically with the CeraFab7500 3D ceramic printer (LC). All completed specimens were loaded until fracture using a universal testing machine. Biaxial flexural strengths and Weibull parameters were computed for the ZD groups and for the LC group. Group and sub-group effects were evaluated using Welch ANOVA (alpha = 0.05). RESULTS: The mean (standard deviation, SD) biaxial flexural strengths of vertically oriented ZD samples with (ZD1) and without (ZD2/ZD3) staining were 811 (197) and 850 (152) MPa, respectively (p > 0.05). The ZD4 (horizontally printed), 1107 (144) MPa, and LC (1238 (327)) MPa samples had higher mean (SD) flexural strengths than the ZD1-3 specimens. No difference was observed between the ZD4 and LC group (p > 0.05). Weibull moduli were between m = 4.6 (ZD1) and 9.1 (ZD4) in the ZD group and m = 3.5 in the LC group. CONCLUSIONS: All tested 3D-printed zirconia specimens exceeded the flexural strengths required for class 5 restorations according to ISO 6872 standards. While the flexural strengths of zirconia printed using the novel ZD device in the vertical orientation are lower than those of zirconia printed using the LC printer, the ZD printer shows at least comparable reliability. CLINICAL RELEVANCE: 3D-printing of zirconia is a new technology in dental application. Based on the presented strengths values, clinical application of 3D-printed zirconia for fixed dental protheses can be recommended.


Asunto(s)
Cerámica , Resistencia Flexional , Ensayo de Materiales , Reproducibilidad de los Resultados , Propiedades de Superficie , Circonio , Impresión Tridimensional , Materiales Dentales
8.
Clin Oral Implants Res ; 35(3): 340-349, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38225734

RESUMEN

BACKGROUND AND OBJECTIVES: The aim of implantoplasty (IP) is to remove titanium implant layers that have been contaminated and to smoothen the implant surfaces so they retain less plaque. However, existing IP methods are very invasive and reduce implant wall thickness. AIM: To investigate the suitability of novel sonic tips in IP and to compare this novel protocol with conventional abrasive procedures. MATERIALS AND METHODS: Thirty dental implants (Ø 4.1 mm, 10 mm length) were distributed in three groups and investigated according to the protocol of Sivolella et al., with modifications to the instrument's feed rate, the applied contact force, and the speed of implant rotations per minute. The upper third of the implant was processed with a diamond-coated bur (BUR) or novel non-diamond-coated sonic tips (AIRSCALER). After standardized IP, the surfaces were analyzed by tactile profilometry and scanning electron microscopy (SEM). Changes in implant weight, implant material loss, and implant fracture strength were assessed. RESULTS: The mean roughness (Ra , Sa ), implant material loss, and change in implant weight were significantly lower in the AIRSCALER group than in the BUR group, whereas the mean compression resistance values were significantly higher in the AIRSCALER group than in the BUR group. CONCLUSIONS: IP with uncoated sonic tips smoothes the surfaces and reduces structural loss of the implant in the area of microthreads. This new IP method could be of great clinical importance, especially for implants with microthreads and reduced diameter or wall thickness.


Asunto(s)
Implantes Dentales , Proyectos Piloto , Ensayo de Materiales , Pulido Dental , Propiedades de Superficie , Titanio/química , Microscopía Electrónica de Rastreo
9.
Clin Oral Investig ; 28(1): 94, 2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-38221600

RESUMEN

OBJECTIVES: The aim of this study was to compare failure load and initial damage in monolithic, partially veneered, and completely veneered (translucent) zirconia cantilevered fixed partial dentures (CFPDs), as well as completely veneered metal-ceramic CFPDs under different support and loading configurations. MATERIALS AND METHODS: Eight test groups with anatomically congruent CFPDs (n = 8/group) were fabricated, differing in CFPD material/support structure/loading direction (load applied via steel ball (Ø 6 mm) 3 mm from the distal end of the pontic for axial loading with a 2-point contact on the inner cusp ridges of the buccal and oral cusps and 1.3 mm below the oral cusp tip for 30° oblique loading): (1) monolithic zirconia/CoCr abutment teeth/axial, (2) monolithic zirconia/CoCr abutment teeth/oblique, (3) partially veneered zirconia/CoCr abutment teeth/axial, (4) partially veneered zirconia/CoCr abutment teeth/oblique, (5) completely veneered zirconia/CoCr abutment teeth/axial, (6) completely veneered CoCr/CoCr abutment teeth/axial (control group), (7) partially veneered zirconia/implants/axial, and (8) partially veneered zirconia/natural teeth/axial. Restorations were artificially aged before failure testing. Statistical analysis was conducted using one-way ANOVA and Tukey post hoc tests. RESULTS: Mean failure loads ranged from 392 N (group 8) to 1181 N (group 1). Axially loaded monolithic zirconia CFPDs (group 1) and controls (group 6) showed significantly higher failure loads. Oblique loading significantly reduced failure loads for monolithic zirconia CFPDs (group 2). Initial damage was observed in all groups except monolithic zirconia groups, and fractography revealed design flaws (sharp edges at the occlusal boundary of the veneering window) in partially veneered zirconia CFPDs. CONCLUSIONS: Monolithic zirconia CFPDs might be a viable alternative to completely veneered CoCr CFPDs in terms of fracture load. However, oblique loading of monolithic zirconia CFPDs should be avoided in clinical scenarios. Design improvements are required for partially veneered zirconia CFPDs to enhance their load-bearing capacity. CLINICAL RELEVANCE: Monolithic zirconia may represent a viable all-ceramic alternative to the established metal-ceramic option for CFPD fabrication. However, in daily clinical practice, careful occlusal adjustment and regular monitoring should ensure that oblique loading of the cantilever is avoided.


Asunto(s)
Cerámica , Fracaso de la Restauración Dental , Circonio , Dentadura Parcial Fija , Porcelana Dental , Ensayo de Materiales , Análisis del Estrés Dental , Coronas
10.
Clin Oral Investig ; 28(1): 73, 2024 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-38175247

RESUMEN

OBJECTIVE: The Oral Impact of Daily Performances (OIDP) is a dental patient-reported outcome measure (dPROM) for the estimation of oral health-related quality of life (OHRQoL) and takes the frequency as well as the severity of problems into account; however, it is not available in German language. The aim of this study was, therefore, to evaluate the reliability and validity of the German version of the OIDP in patients of a private practice. MATERIAL AND METHODS: Translation of the original OIDP version was performed by a forward-backward process. Reliability was evaluated in terms of construct stability (test-retest) for the single items and the sum scores. The responsiveness to change in oral health status was assessed by pre- and post-treatment comparison, in addition. Validity was assessed as convergent validity in comparison with other dPROMs (OHIP-14; GOHAI) and objective dental findings. RESULTS: A total of 330 patients participated in this study (mean age: 42.0 (18.0)). The OHRQoL of the participants was relatively high (OIDP score 4.3 (SD 14.3), OHIP score 4.8 (SD 5.3), GOHAI score 54.2 (SD 5.4)). A moderate construct stability for the total OIDP-score (ICC 0.686) was found whilst reliability for the single items varied between 0.179 (social contact) to 0.559 (showing teeth). Significant correlations were found for OIDP and OHIP (p < 0.001; r = 0.361) and OIDP and GOHAI (p < 0.001; r = - 0.391) indicating moderate validity with a tendency to even stronger correlations for OIDP-s and OIDP-f (r ≥ 0.500). CONCLUSIONS: The German version of the OIDP demonstrated sufficient reliability and validity. OIDP's general performance should be interpreted cautiously as the outcome was detected in a specifically healthy population. CLINICAL RELEVANCE: The OIDP is yet the only dPROM that evaluates both severity as well as frequency which makes validation interesting regarding specific target populations.


Asunto(s)
Estado de Salud , Calidad de Vida , Humanos , Adulto , Reproducibilidad de los Resultados , Lenguaje
11.
Materials (Basel) ; 17(1)2024 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-38204115

RESUMEN

The rehabilitation of free-end situations is a frequent indication in prosthetic dentistry. Cantilever fixed dental prostheses (cFDPs) made of 1st and 2nd generation zirconia are one treatment option. Due to a unique gradient technology, combinations of different zirconium dioxide generations are thus feasible in one restoration. However, data about these materials are rare. The purpose of this study was therefore to investigate the fracture resistance and fracture modes of tooth-supported cFDPs fabricated from different zirconia materials (gradient technology) and different framework thicknesses. A total of 40 cFDPs were fabricated using the CAD/CAM approach and belonged to five test groups. The different groups differed in the yttria content, the proportion of the tetragonal/cubic phases, or in wall thickness (0.7 mm or 1 mm). After completion, the cFDPs were subjected to thermal cycling and chewing simulation (1.2 × 106 load cycles, 108 N load). Afterwards, cFDPs were statically loaded until fracture in a universal testing machine. A non-parametric ANOVA was compiled to determine the possible effects of group membership on fracture resistance. In addition, post-hoc Tukey tests were used for bivariate comparisons. The mean fracture loads under axial load application ranged from 288 to 577 N. ANOVA detected a significant impact of the used material on the fracture resistances (p < 0.001). Therefore, the use of cFDPs fabricated by gradient technology zirconia may not be unreservedly recommended for clinical use, whereas cFPDs made from 3Y-TZP exhibit fracture resistance above possible masticatory loads in the posterior region.

12.
Dent Mater ; 40(3): 484-492, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38155019

RESUMEN

OBJECTIVES: To evaluate the effect of accelerated firing on 3D-printed zirconia. METHODS: To check if formulae provided by ISO 6872 can be extended to thin samples, finite element analyses were carried out in advance of fabricating 3-mol% yttria-stabilized tetragonal zirconia polycrystal discs by milling and by 3D-printing. Four groups (n = 38 each) of 3D-printed specimens were produced with two nominal thicknesses (0.6 mm and 1.2 mm) and two firing strategies (long: 51 h, accelerated: 14.5 h). In the milled group (thickness 1.2 mm, n = 30), a standard firing program (9.8 h) was selected. Biaxial flexural strength tests were applied and mean strength, characteristic strength, and Weibull modulus were calculated for each group. Differences were analyzed using Welch ANOVA and Dunnett-T3 post-hoc tests. RESULTS: Maximum tensile stresses occurring during biaxial strength testing can be calculated according to ISO 6872 for thin samples with b > 0.3 mm. Variability of measured strengths values was smaller for milled zirconia compared with 3D-printed zirconia. The 1.2-mm-thick 3D-printed samples had significantly decreased strength after accelerated firing than after long firing. However, for the 0.6-mm-thick samples, comparable mean biaxial strength values of about 1000 MPa were measured for both firing protocols. SIGNIFICANCE: At the moment, long fabrication time for zirconia restorations is a major drawback of 3D-printing when compared with milling technology. This investigation showed that the strength of 0.6-mm-thick zirconia discs fabricated by 3D-printing was not impaired by accelerated firing. Thus, overnight firing of thin-walled 3D-printed zirconia restorations could be possible.


Asunto(s)
Materiales Dentales , Resistencia Flexional , Materiales Dentales/química , Ensayo de Materiales , Propiedades de Superficie , Circonio/química , Impresión Tridimensional , Cerámica/química
13.
Int J Prosthodont ; 36(6): 133-142, 2023 Dec 18.
Artículo en Inglés | MEDLINE | ID: mdl-38112736

RESUMEN

PURPOSE: To examine the effects of anodization and different surface modifications of titanium on bond strength to 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP) resin cement. MATERIALS AND METHODS: Grade 5 titanium alloy disks (n = 160) were assigned to one of five prebonding surface treatment study groups (polished; polished and anodized; polished, etched, and anodized; sandblasted; sandblasted and anodized). Disks were adhesively bonded with 10-MDP resin cement (Panavia 21; bonding area: 3.3 mm in diameter) to composite resin cylinders. In each study group, tensile bond strength tests were conducted after 24 ± 1 hours and after 6 months (180 ± 2 days) of water storage (n = 16 specimens per water storage subgroup). Debonded specimens were stereomicroscopically analyzed to determine their fracture mode. Statistics included one-way and multifactorial ANOVA and Tukey post hoc tests (α = .05). RESULTS: Anodization and water storage did not significantly (P ≥ .389) affect tensile bond strength. Although subgroups of polished samples had significantly (P ≤ .031) lower bond strengths (subgroup mean values: 20 to 26 MPa) than etched or sandblasted samples (subgroup mean values: 29 to 33 MPa), they nonetheless exceeded the empirical threshold of 10 MPa used as a criterion for clinical recommendation. The fracture mode of all test specimens was predominantly cohesive. CONCLUSIONS: Anodization of titanium surfaces can be performed without weakening the adhesion of 10-MDP-based resin cement to titanium.


Asunto(s)
Recubrimiento Dental Adhesivo , Cementos de Resina , Cementos de Resina/química , Titanio , Propiedades de Superficie , Metacrilatos/química , Agua/química , Ensayo de Materiales , Circonio/química , Análisis del Estrés Dental , Resistencia a la Tracción
14.
J Funct Biomater ; 14(8)2023 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-37623661

RESUMEN

PURPOSE: To evaluate fit and retention of cobalt-chromium removable partial denture (RPD) frameworks fabricated with selective laser melting (SLM). METHODS: Three types of framework for clasp-retained RPDs were virtually designed and fabricated using SLM (n = 30). For comparison, 30 additional frameworks were produced using conventional lost-wax casting. A biomechanical model was created, incorporating extracted teeth mounted on flexible metal posts. Using this model, horizontal constraint forces resulting from a misfit were measured using strain gauges, while vertical forces were not recorded. The constraint force components and resultant forces were determined for all abutment teeth, and the maximum retention force during RPD removal from the model was also assessed. For statistical evaluation, the two fabrication methods were analyzed by calculating the means and standard deviations. RESULTS: The average horizontal constraint forces showed similar values for both fabrication methods (SLM: 3.5 ± 1.0 N, casting: 3.4 ± 1.6 N). The overall scatter of data for cast RPDs was greater compared to those fabricated using SLM, indicating a better reproducibility of the SLM process. With regard to retention, the intended retention force of 5-10 N per abutment tooth was not attained in one of the cast groups, while it was consistently achieved in all SLM groups. CONCLUSIONS: This in vitro study found that SLM is a promising option for the manufacture of cobalt-chromium RPD frameworks in terms of fit and retention.

15.
J Clin Periodontol ; 50(11): 1530-1538, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37518848

RESUMEN

AIM: To evaluate the long-term survival, incidence of prosthetic/technical and biological complications and the oral-health-related quality of life in patients with an edentulous mandible who were fitted with overdentures on two immediately loaded implants in the symphyseal area. MATERIALS AND METHODS: Forty-six patients with edentulous mandibles received two immediately loaded implant-retained dentures with either two Locator attachments or egg-shaped bar attachments. Implant outcomes were recorded after a period of observation of 9 years and included prosthetic complications, modified gingiva index (mGI), modified plaque index (mPI), oral health impact profile (OHIP-G) and radiographic estimation of bone loss. RESULTS: In 2020/2021, 27 patients with 54 implants were still available for follow-up. In total, nine implants in six patients were lost. Survival was 89.1% in the bar group and 91.3% in the Locator group. Implant success was 84.6% in the Locator group and 76.9% in the bar group. The mPI values were significantly higher in the bar group than in the Locator group, whereas no difference was seen in the mGI values. During the observation period, 152 prosthetic complications occurred, but the OHIP-G score did not differ significantly. CONCLUSIONS: There was no difference in implant survival between Locator or joint bar attachments over a 9-year observation period. Joint bar attachments were associated with slightly more complications, while patients in the Locator group were able to maintain better oral hygiene. The study was registered in the German Register of Clinical (Trials DRKS00004245).

16.
Eur J Dent ; 17(4): 1221-1228, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37276882

RESUMEN

OBJECTIVES: To investigate the impact of the severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2) pandemic on stress and anxiety of preclinical and clinical dental students. MATERIALS AND METHODS: Dental students (participants) in their clinical course (CC; n = 64) or preclinical course (PCC; n = 53) were included in the study. The subjective perceived levels of stress and anxiety were evaluated using the Dental Environment Stress (DES) questionnaire and the Depression, Anxiety and Stress Scales (DASS) questionnaire. Cortisol levels were measured in saliva samples collected from participants. Knowledge of the pandemic was evaluated using a 100-mm visual analog scale. All data were collected twice: once during the university holidays and once during term time. STATISTICAL ANALYSIS: Results from DES, DASS, and salivary cortisol tests were compared between baseline and follow-up using descriptive and bivariate statistics. Multivariate linear regression models were computed with DES, DASS, and cortisol values as dependent variables to analyze possible influencing factors. RESULTS: Participants showed medium levels of stress and anxiety at baseline and follow-up. The DASS score in the "anxiety" subdomain was significantly higher in the PCC group than in the CC group at baseline (p < 0.001) and increased during term time. DASS scores in the "stress" subdomain also increased during term time. However, both subdomain scores were lower than the cutoff value for a psychological disorder. The mean total DES scores were 615.9 ± 97.7 in the CC group and 580.40 ± 98.9 in the PCC group. These scores indicated medium stress levels and were not significantly different between the groups, nor did they change during the study period. Mean saliva cortisol levels were higher in the CC group (9.2 ± 5.2) than in the PCC group (4.9 ± 2.2) at baseline (p < 0.001) but converged by follow-up. Multivariate regression models showed that intraindividual perception of stress at baseline was consistently the most important aspect for changes in stress and anxiety levels during term time. The SARS-CoV-2 pandemic affected stress and anxiety levels in some participants, but this was not ubiquitous. CONCLUSION: Intraindividual differences in stress perception seem to be more relevant than course affiliation (preclinical or clinical) or the SARS-CoV-2 pandemic to stress and anxiety levels in dental students.

17.
Int J Prosthodont ; 2023 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-37222705

RESUMEN

PURPOSE: The aim of the present study was to generate data on the long-term survival of metal-ceramic resin-bonded fixed partial dentures. MATERIAL AND METHODS: Eighty-nine participants, received 94 RBFPDs, 5 (n women = 1; n men = 4) received 2 RBFPDs each. All RBFPDs were fabricated as two-retainer end-abutment metal-ceramic restorations. Clinical follow-ups were performed 6 weeks after cementation and annually thereafter. The mean observation time was 7.5 years. Cox regression was performed to test the effects of the variables sex, location, jaw, design, use of rubber dam, and adhesive luting system Survival and success were calculated by using Kaplan-Meier curves. As a secondary objective, patient and dentist satisfaction with the esthetics and function of the RBFPDs was evaluated. The significance level was set at α = .05 for all calculations. RESULTS: Estimated Kaplan-Meier failure-free survival was 97.5% (standard error [SE] 1.7) after 5 years and 83.3% (SE 5.3) after 10 years. Calculated intervention-free survival (success) was 90.1% (SE 3.4) after 5 years and 65.5% (SE 6.7) after 10 years. Debonding-free survival was 92.6% (SE 2.9) after 5 years and 80.6% (SE 5.4) after 10 years. Cox regression revealed none of the four tested variables had a significant effect on the incidence of complications in RBFPDs. Patient and dentist satisfaction with RBFPD esthetics and function was consistently high throughout the observation period. CONCLUSIONS: Within the limitations of an observational study, RBFPDs achieved clinically successful outcomes over a mean observational period of 7.5 years.

19.
J Clin Med ; 12(8)2023 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-37109126

RESUMEN

OBJECTIVES: To evaluate oral sequelae after head and neck radiotherapy (RT) when using two different types of intraoral appliances. Thermoplastic dental splints (active control) protect against backscattered radiation from dental structures. Semi-individualized, 3D-printed tissue retraction devices (TRDs, study group) additionally spare healthy tissue from irradiation. MATERIALS AND METHODS: A total of 29 patients with head and neck cancer were enrolled in a randomized controlled pilot trial and allocated to receive TRDs (n = 15) or conventional splints (n = 14). Saliva quality and quantity (Saliva-Check, GC), taste perception (Taste strips, Burghart-Messtechnik), and oral disability (JFLS-8, OHIP-14, maximum mouth opening) were recorded before and 3 months after RT start. Radiotherapy target volume, modality, total dose, fractionation, and imaging guidance were case-dependent. To evaluate intra-group developments between baseline and follow-up, nonparametric Wilcoxon tests were performed. Mann-Whitney-U tests were applied for inter-group comparisons. RESULTS: At follow-up, taste perception was unimpaired (median difference in the total score; TRDs: 0, control: 0). No significant changes were found regarding oral disability. Saliva quantity (stimulated flow) was significantly reduced with conventional splints (median -4 mL, p = 0.016), while it decreased insignificantly with TRDs (median -2 mL, p = 0.07). Follow-up was attended by 9/15 study group participants (control 13/14). Inter-group comparisons showed no significant differences but a tendency towards a better outcome for disability and saliva quality in the intervention group. CONCLUSION: Due to the small cohort size and the heterogeneity of the sample, the results must be interpreted with reservation. Further research must confirm the positive trends of TRD application. Negative side-effects of TRD application seem improbable.

20.
J Dent ; 133: 104514, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37031885

RESUMEN

OBJECTIVES: To compare the clinical performance of occlusal splints printed from thermo-flexible resin with milled splints. METHODS: A parallel two-arm pilot trial was initiated. Forty-seven patients (n women=38) were recruited from a tertiary care center and randomized using an online tool (sealed envelope). Inclusion criterion was an indication for treatment with a centric relation occlusal splint due to bruxism or any form of painful temporomandibular disorder. Patients were excluded if they were younger than 18 years, unable to attend follow-up appointments, or required another type of splint therapy. Patients received either, a 3D-printed (intervention group, V-print splint comfort, VOCO) or a milled splint (control group, ProArt CAD splint, Ivoclar). Construction software Ceramill M-splint (AmannGirrbach), 3D-printer MAX UV 385 (Asiga) and milling unit PrograMill PM7 (Ivoclar) were used. Follow-up assessments were conducted after 2 weeks and 3 months. Outcome measures were survival, adherence, technical complications, patient satisfaction on a 10-point Likert scale, and maximum wear using superimposition of optical scans. RESULTS: After 3 months, 20/23 intervention group and 18/24 control group participants were assessed. All splints survived. Minor complications were small crack formations on 6 printed and 4 milled splints. Mean patient satisfaction was 8 (SD 1.7) for printed, and 8.1 (SD 2.3) for milled splints (r = 0.1, p = .52). Median maximum wear was highly dispersed with 153 (IQR 140) in posterior and 195 (IQR 537) in frontal segments of printed, and 96 (IQR 78) respectively, 123 (IQR 155) of milled splints, (both: r = 0.31, p = .084). CONCLUSIONS: Within the limitations of a pilot trial, 3D-printed and milled splints performed similarly in terms of patient satisfaction, complication rates and wear behavior. CLINICAL SIGNIFICANCE: Thermo-flexible material was proposed for 3D printing of occlusal splints to overcome mechanical weaknesses of previously available resins. This randomized pilot study provides evidence that this material is a viable alternative to milled splints for at least three months of clinical use. Further evidence on long-term use should be obtained.


Asunto(s)
Bruxismo , Ferulas Oclusales , Humanos , Femenino , Proyectos Piloto , Impresión Tridimensional , Férulas (Fijadores)
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA