Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Pediatr Radiol ; 54(6): 863-875, 2024 05.
Artículo en Inglés | MEDLINE | ID: mdl-38488925

RESUMEN

Magnetic resonance imaging (MRI) is now an indispensable diagnostic tool in medicine due to its outstanding contrast resolution and absence of radiation exposure, enabling detailed tissue characterization and three-dimensional anatomical representation. This is especially important when evaluating individuals with congenital heart disease (CHD) who frequently require cardiac implantable electrical devices (CIEDs). While MRI safety issues have previously limited its use in patients with CIEDs, new advances have called these limitations into question. However, difficulties persist in the pediatric population due to the continued lack of specific safety data both related to imaging young children and the specific CIED devices they often require. This paper discusses MRI safety considerations related to imaging patients with CIEDs, investigates pediatric-specific problems, and describes thorough methods for safe MRI access, highlighting the significance of specialized institutional guidelines.


Asunto(s)
Desfibriladores Implantables , Cardiopatías Congénitas , Imagen por Resonancia Magnética , Marcapaso Artificial , Niño , Humanos , Contraindicaciones de los Procedimientos , Cardiopatías Congénitas/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Seguridad del Paciente
2.
Pediatr Pulmonol ; 59(4): 899-906, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38197524

RESUMEN

INTRODUCTION: Tracheomalacia (TM) is an important cause of respiratory morbidity. Dynamic flexible bronchoscopy is considered the gold standard for diagnosis. Dynamic airway computed tomography (DACT) is a low radiation, noninvasive diagnostic tool utilizing images obtained continuously over several respiratory cycles. We aimed to assess the accuracy of DACT in TM diagnosis. METHODS: Retrospective analysis of all patients who underwent both DACT and flexible bronchoscopy within 6 months. Airway anterior-posterior (AP) diameter was measured on multiplanar reconstructions CT in both the inspiratory and expiratory phases. Using still images from the bronchoscopy videos, the AP diameter of the trachea was measured at points of maximal and minimal diameter during tidal breathing. Degree of TM on both DACT and flexible bronchoscopy were graded using a scaling system of 50%-74%, 75%-89%, and 90%-100% as described by the European Respiratory Society. RESULTS: Twenty-four patients met inclusion criteria with an average time of 19.5 days between CT and bronchoscopy. The specificity and sensitivity of DACT for the overall diagnosis of TM was 100% and 68%, respectively, with a positive predictive value of 100% and a negative predictive value of 62%. There was a strong positive correlation between DACT and flexible bronchoscopy in the measurement of tracheal AP diameter changes (ρ = 0.773, R2 0.597, p = 0.00001). Mean effective radiation dose for DACT was 0.1 mSv. CONCLUSION: Ultralow dose DACT has excellent specificity and positive predictive value for both detection of TM and categorizing severity of tracheal collapse but is not sufficiently sensitive to rule it out.


Asunto(s)
Traqueomalacia , Niño , Humanos , Traqueomalacia/diagnóstico por imagen , Broncoscopía/métodos , Estudios Retrospectivos , Tráquea/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos
3.
Horm Res Paediatr ; 2023 Nov 13.
Artículo en Inglés | MEDLINE | ID: mdl-37956658

RESUMEN

INTRODUCTION: Radiation-induced lung injury is a rare complication of radioactive iodine therapy (RAIT) in pediatric thyroid cancer treatment. In this case report, we describe a pediatric patient with an ERC1::RET-positive classic papillary thyroid carcinoma who developed progressive respiratory symptoms and chest imaging abnormalities following RAIT for lymph node and pulmonary disease. CASE PRESENTATION: A pediatric patient with ERC1::RET-positive classic papillary thyroid carcinoma was hospitalized for pulmonary decompensation three months following one empiric dose of RAIT. Testing revealed no evidence of infection or progression of pulmonary metastases, and there was no improvement with empiric antibiotic therapy for pneumonia. Despite empiric anti-inflammatory therapies, the patient remains symptomatic from a respiratory standpoint with requirement for supplemental oxygen and evidence of fibrotic changes on chest imaging. CONCLUSIONS: This patient's pulmonary condition is consistent with radiation-induced pulmonary injury including development of pulmonary fibrosis. With the availability of RET fusion targeted inhibitors, this case highlights a rare pulmonary side effect of radioactive iodine for clinicians to recognize. Upfront targeted therapy protocols may help avoid radioactive iodine-associated adverse reactions.

4.
AJR Am J Roentgenol ; 221(4): 526-538, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37195790

RESUMEN

Dual-energy CT has expanded the potential of thoracic imaging in both children and adults. Data processing allows material- and energy-specific reconstructions, which improve material differentiation and tissue characterization compared with single-energy CT. Material-specific reconstructions include iodine, virtual unenhanced, perfusion blood volume, and lung vessel images, which can improve assessment of vascular, mediastinal, and parenchymal abnormalities. The energy-specific reconstruction algorithm allows virtual monoenergetic reconstructions, including low-energy images to increase iodine conspicuity and high-energy images to reduce beam-hardening and metal artifacts. This review highlights dual-energy CT principles, hardware, and postprocessing algorithms; the clinical applications of dual-energy CT; and the potential benefits of photon counting (the most recently introduced iteration of spectral imaging) in pediatric thoracic imaging.


Asunto(s)
Yodo , Imagen Radiográfica por Emisión de Doble Fotón , Adulto , Humanos , Niño , Tomografía Computarizada por Rayos X/métodos , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Algoritmos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
5.
Pediatr Radiol ; 53(7): 1248-1259, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35948645

RESUMEN

The gold standard for pediatric chest imaging remains the CT scan. An ideal pediatric chest CT has the lowest radiation dose with the least motion degradation possible in a diagnostic scan. Because of the known inherent risks and costs of anesthesia, non-sedate options are preferred. Dual-source CTs are currently the fastest, lowest-dose CT scanners available, utilizing an ultra-high-pitch mode resulting in sub-second CTs. The dual-energy technique, available on dual-source CT scanners, gathers additional information such as pulmonary blood volume and includes relative contrast enhancement and metallic artifact reduction, features that are not available in high-pitch flash mode. In this article we discuss the benefits and tradeoffs of dual-source CT scan modes and tips on image optimization.


Asunto(s)
Anestesia , Tomografía Computarizada por Rayos X , Humanos , Niño , Tomografía Computarizada por Rayos X/métodos , Pulmón , Tórax , Cintigrafía
6.
Pediatr Radiol ; 53(7): 1380-1390, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35980463

RESUMEN

The lymphatic system has been poorly understood and its importance neglected for decades. Growing understanding of lymphatic flow pathophysiology through peripheral and central lymphatic flow imaging has improved diagnosis and treatment options in children with lymphatic diseases. Flow dynamics can now be visualized by different means including dynamic contrast-enhanced magnetic resonance lymphangiography (DCMRL), the current standard technique to depict central lymphatics. Novel imaging modalities including intranodal, intrahepatic and intramesenteric DCMRL are quickly evolving and have shown important advances in the understanding and guidance of interventional procedures in children with intestinal lymphatic leaks. Lymphatic imaging is gaining importance in the radiologic and clinical fields and new techniques are emerging to overcome its limitations.


Asunto(s)
Enfermedades Linfáticas , Vasos Linfáticos , Niño , Humanos , Medios de Contraste , Vasos Linfáticos/patología , Sistema Linfático/diagnóstico por imagen , Enfermedades Linfáticas/diagnóstico por imagen , Enfermedades Linfáticas/patología , Linfografía/métodos
7.
Radiol Cardiothorac Imaging ; 4(5): e220035, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36339058

RESUMEN

The lymphatic system plays an integral part in fluid homeostasis. Disturbances in lymphatic pathways are congenital, posttraumatic, or posttreatment related, such as after Fontan palliation. Lymphatic pathway evaluation is challenging because of the difficulty in introducing contrast material into the lymphatics. Intranodal, intramesenteric, and intrahepatic dynamic contrast-enhanced MR lymphangiography (DCMRL) offer better visualization of major lymphatic pathways. However, these techniques exclude pathways outside the central conduction system, preventing the visualization of abnormalities and, thus, administration of treatment. The authors describe alternative imaging of an axillary pathway via DCMRL in a patient with a symptomatic chylous effusion not previously assessed with current techniques. Keywords: Lymphatic, MR-Dynamic Contrast Enhanced, Pediatrics, Thorax, Pleura Supplemental material is available for this article. © RSNA, 2022.

8.
Pediatr Radiol ; 52(10): 1998-2008, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35953542

RESUMEN

Amid the coronavirus disease 2019 (COVID-19) pandemic, numerous publications of imaging findings in children have surfaced in a very short time. Publications discuss populations of overlapping age groups and describe different imaging patterns. We aim to present an overview of the quantity and type of literature available regarding COVID-19 chest imaging findings in children according to a 2020 publication timeline. We conducted a systematic review using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guideline. We searched terminology related to COVID-19, chest, children and imaging modalities in PubMed and Embase. The included papers were published online in 2020 and described imaging findings specific to children and reported five or more cases. Two researchers reviewed each abstract to determine inclusion or exclusion, and a radiologist reconciled any disagreements. Then we reviewed full articles for the main analysis. Eligible study designs included original articles, case series (≥5 cases), systematic reviews and meta-analyses. We excluded non-English manuscripts, retracted articles, and those without available full text. The remaining articles were distributed to four pediatric radiologists (on the Society for Pediatric Radiology Thoracic Committee), who summarized chest imaging findings. Eighty-two articles were included in the final analysis - 28% in radiology journals and 71% in non-radiology journals; 71% contained original data and 29% were review-style papers. There was a disproportionate contribution of review-style papers in April (55%), considering the paucity of preceding publications with original data in March (5 papers). June had the highest number of publications (n=14), followed by April (n=11) and July (n=11). Most (52%) original papers were from China and most individual pediatric imaging descriptions were from China (57%), while the majority of review papers (83%) were international. Imaging descriptions were available for 2,199 children (1,678 CT descriptions and 780 chest radiography descriptions). Findings included a 25% normal CT scan reports vs. 40% normal chest radiography reports. Ground-glass opacification was the most common CT finding (33%) and was reported in only a minority of chest radiographs (9%). A significant amount of information on pediatric COVID-19 chest imaging has become rapidly available over a short period. Most publications in 2020 were original articles, but they were published more often in non-radiology journals. A disproportionate number of review articles were published early on and were based on little original pediatric imaging data. CT scan reports, which represent the standard, outnumbered radiographic reports and indicated that ground-glass opacification is the main imaging finding and that only a quarter of scans are normal in children with COVID-19.


Asunto(s)
COVID-19 , Niño , China , Humanos , Pandemias , SARS-CoV-2 , Tomografía Computarizada por Rayos X/métodos
9.
Pediatr Radiol ; 52(10): 1862-1876, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35840695

RESUMEN

Congenital heart disease can lead to various lymphatic complications including traumatic leaks, lymphatic overproduction, conduction abnormalities or lymphedema. Advancements in the imaging of central lymphatics and guided interventions have improved outcomes in these children. Dynamic contrast-enhanced magnetic resonance (MR) lymphangiography allows for the assessment of abnormal lymphatic drainage. This technique is preferred for evaluating lymphatic conditions such as plastic bronchitis, chylothorax, chyloptysis, chylopericardium, protein-losing enteropathy and chylous ascites, among other lymphatic disorders. In this review, we discuss lymphatic abnormalities encountered on MRI in children with congenital heart disease. We also briefly review treatment options.


Asunto(s)
Quilotórax , Cardiopatías Congénitas , Anomalías Linfáticas , Niño , Quilotórax/diagnóstico por imagen , Quilotórax/terapia , Cardiopatías Congénitas/complicaciones , Cardiopatías Congénitas/diagnóstico por imagen , Humanos , Anomalías Linfáticas/diagnóstico por imagen , Sistema Linfático/diagnóstico por imagen , Linfografía/métodos , Imagen por Resonancia Magnética/métodos
10.
Pediatr Radiol ; 52(10): 1910-1920, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35726069

RESUMEN

Computed tomography technology continues to undergo evolution and improvement with each passing decade. From its inception in 1971, to the advent of commercially available dual-energy CT just over a decade ago, and now to the latest innovation, photon-counting detector CT, CT's utility for resolving and discriminating tissue types improves. In this review we discuss the impact of spectral imaging, including dual-energy CT and the recently available photon-counting detector CT, on the imaging of the pediatric chest. We describe the current capabilities and future directions of CT imaging, encompassing both the lungs and the surrounding tissues.


Asunto(s)
Fotones , Tórax , Niño , Humanos , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/métodos
11.
J Comput Assist Tomogr ; 46(5): 742-746, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35617648

RESUMEN

PURPOSE: Children with single-ventricle congenital heart disease undergo a series of operations to maintain their pulmonary circulation including bidirectional Glenn (BDG) or hemi-Fontan in the second stage to create a superior cavopulmonary anastomosis. We aimed to optimize cardiovascular angiography protocols by determining optimal contrast timing of pulmonary and systemic circulation on magnetic resonance angiography (MRA) performed with the technique of time-resolved imaging with interleaved stochastic trajectories (TWIST). METHODS AND MATERIALS: Cardiac TWIST MRA with lower extremity (LE) contrast injection was analyzed in 92 consecutive patients with a BDG or hemi-Fontan anastomosis. Contrast arrival time to inferior vena cava was set to zero to determine the relative time-to-peak (TTP) of the target vessels. Time-to-peak of each vessel was compared by age (<2 or ≥2 y), ejection fraction (<54% or ≥54%), the median values of heart rate (<111 or ≥111 beats per minute), body surface area (BSA, <0.59 or ≥0.59), cardiac index (<6.04 or ≥6.04), and indexed ascending aorta flow (AscAo_i, <5.3 or ≥5.3). The TTP of the vessels was also correlated with the volumetric parameters. RESULTS: The mean age of 92 patients (32 female, 60 male) was 3.1 years (0.7-5.6 years). With LE injection, the first peak was depicted in AscAo. Time-to-peak of the pulmonary arteries was approximately 9 seconds later than AscAo. The TTP difference between pulmonary arteries and AscAo was shorter in high heart rate group (8.3 vs 10 seconds, P < 0.001). The TTP difference between AscAo and the mean of pulmonary arteries was significantly shorter in high cardiac index group (8.4 vs 9.9 seconds, P < 0.01) and high AscAo_i group (8.7 vs 9.7 seconds, P = 0.03). The TTP differences were not significant by age, ejection fraction, and BSA. Cardiac index and AscAo_i were negatively correlated with all TTPs except AscAo. The ejection fraction, stroke volume, and atrioventricular regurgitation fraction did not correlate with the TTP. CONCLUSIONS: In patients with BDG or hemi-Fontan anastomosis, TTP of the pulmonary arteries on TWIST MRA via LE intravenous injection is approximately 9 seconds later than AscAo, approximately 8 and 10 seconds later in high and low heart rate groups, respectively. Cardiac index and AscAo_i have less effect on the TTP than the heart rate. There was no TTP difference of the pulmonary arteries by age, BSA, and ejection fraction and no correlation with ejection fraction, stroke volume, and atrioventricular regurgitation fraction. These data can be used to guide timing of pulmonary arterial enhancement of single-ventricle patients after BDG or hemi-Fontan anastomosis.


Asunto(s)
Procedimiento de Fontan , Cardiopatías Congénitas , Anciano de 80 o más Años , Niño , Femenino , Procedimiento de Fontan/métodos , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/cirugía , Humanos , Lactante , Angiografía por Resonancia Magnética , Masculino , Arteria Pulmonar/diagnóstico por imagen , Circulación Pulmonar , Resultado del Tratamiento
12.
Eur Radiol ; 32(4): 2564-2571, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35001156

RESUMEN

PURPOSE: To assess the feasibility of direct intra-lymphatic administration of diluted ferumoxytol as a T1-positive contrast agent for dynamic contrast-enhanced MR lymphangiography (DCMRL) imaging of the central lymphatics in children with renal disease. METHODS: In vitro scan of dilute ferumoxytol was initially performed using time-resolved and high-resolution 3D gradient echo (GRE) sequences with short TE values (1 to 1.5 ms). A ferumoxytol concentration of 0.25 to 0.40 mg/mL was found to retain high signal in the T1-weighted sequences. DCMRL was then performed in 4 children with renal disease with the same 3D GRE sequences administrating diluted ferumoxytol via intra-mesenteric (IM), intra-hepatic (IH), and intra-nodal (IN) routes (6 to 9 mL to each site; average total dose of 0.75 mg/kg) by slow hand injection (0.5 to 1.0 mL/min). The signal-to-noise ratio (SNR) of the lymphatics was measured for quantitative evaluation. RESULTS: Ferumoxytol-enhanced DCMRL was technically successful in all patients. Contrast conspicuity within the lymphatics was sufficient without subtraction. The mean SNR was significantly higher than the muscle (50.1 ± 12.2 vs 13.2 ± 2.8; t = 15.9; p < .001). There were no short-term complications attributed to the administration of ferumoxytol in any of the four patients. CONCLUSION: Magnetic resonance lymphangiography using ferumoxytol via IN, IH, and IM access is a new method to directly visualize the central lymphatic system and can be applied safely in patients with renal failure based on our preliminary report of four cases. Ferumoxytol-enhanced DCMRL shows diagnostic image quality by using 3D GRE sequences with short TE values and appropriate dilution of ferumoxytol. KEY POINTS: • MR lymphangiography using ferumoxytol via intra-nodal, intra-hepatic, and intra-mesenteric access is a new method to directly visualize the central lymphatic system from the groin to the venous angle. • FDCMRL can be applied safely in patients with renal failure based on our preliminary report of four cases. • FDCMRL shows diagnostic image quality by using 3D GRE sequences with short TE values and appropriate dilution of the ferumoxytol.


Asunto(s)
Óxido Ferrosoférrico , Insuficiencia Renal Crónica , Niño , Medios de Contraste/farmacología , Estudios de Factibilidad , Humanos , Linfografía/métodos , Imagen por Resonancia Magnética/métodos , Insuficiencia Renal Crónica/complicaciones , Insuficiencia Renal Crónica/diagnóstico por imagen
13.
Pediatr Radiol ; 52(2): 285-294, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33830292

RESUMEN

Lymphatic flow disorders include a broad spectrum of abnormalities that can originate in the lymphatic or the venous system. The development of these disorders is multifactorial and is most commonly associated with congenital heart diseases and palliative surgeries that these patients undergo. Central lymphatic disorders might be secondary to traumatic leaks, lymphatic overproduction, conduction abnormalities or lymphedema, and they can progress to perfusion anomalies. Several imaging modalities have been used to visualize the lymphatic system. However, the imaging of central lymphatic flow has always been challenging. Dynamic contrast-enhanced magnetic resonance lymphangiography (DCMRL) allows for visualization of central lymphatic flow disorders and has been recently applied for the assessment of plastic bronchitis, protein-losing enteropathy, chylothorax and chylopericardium, among other lymphatic disorders. The hepatic and mesenteric accesses are innovative and promising techniques for better identification and understanding of these abnormalities. The main objectives of this review are to discuss the physiology and anatomy of the lymphatic system and review the current uses of DCMRL in the diagnosis and management of lymphatic flow disorders.


Asunto(s)
Medios de Contraste , Linfografía , Humanos , Sistema Linfático/diagnóstico por imagen , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética
14.
Pediatr Radiol ; 52(13): 2529-2537, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-34562108

RESUMEN

The presence of airway and lung disease in children with congenital heart disease is commonly observed with both cardiac CT angiography and routine chest CT. In this review we discuss abnormalities encountered on CT imaging of the chest beyond the heart and central vasculature, focusing on the airways, lung parenchyma and peripheral vasculature. Preoperative and postoperative findings are reviewed as well.


Asunto(s)
Cardiopatías Congénitas , Tomografía Computarizada por Rayos X , Niño , Humanos , Tomografía Computarizada por Rayos X/métodos , Pulmón/diagnóstico por imagen , Cardiopatías Congénitas/diagnóstico por imagen , Angiografía/métodos , Corazón
15.
Pediatr Radiol ; 52(4): 661-675, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34657169

RESUMEN

Magnetic resonance imaging (MRI) and CT perform an important role in the evaluation of neonates with congenital heart disease (CHD) when echocardiography is not sufficient for surgical planning or postoperative follow-up. Cardiac MRI and cardiac CT have complementary applications in the evaluation of cardiovascular disease in neonates. This review focuses on the indications and technical aspects of these modalities and special considerations for imaging neonates with CHD.


Asunto(s)
Cardiopatías Congénitas , Tomografía Computarizada por Rayos X , Corazón/diagnóstico por imagen , Cardiopatías Congénitas/diagnóstico por imagen , Humanos , Recién Nacido , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética , Tomografía Computarizada por Rayos X/métodos
16.
Pediatr Pulmonol ; 57(3): 702-710, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34914194

RESUMEN

OBJECTIVE: To evaluate clinical applications of dual-energy computed tomography (DECT) in pediatric-specific lung diseases and compare ventilation and perfusion findings with those from single-photon emission computed tomography (SPECT-CT) V/Q. METHODS: All patients at our institution who underwent exams using both techniques within a 3-month period were included in this study. Two readers independently described findings for DECT, and two other readers independently analyzed the SPECT-CT V/Q scan data. All findings were compared between readers and disagreements were reassessed and resolved by consensus. Inter-modality agreements are described throughout this study. RESULTS: Eight patients were included for evaluation. The median age for DECT scanning was 3.5 months (IQR = 2). Five of these patients were scanned for both DECT and SPECT-CT V/Q studies the same day, and three had a time gap of 7, 65, and 94 days between studies. The most common indications were chronic lung disease (5/8; 63%) and pulmonary hypertension (6/8; 75%). DECT and SPECT-CT V/Q identified perfusion abnormalities in concordant lobes in most patients (7/8; 88%). In one case, atelectasis limited DECT perfusion assessment. Three patients ultimately underwent lobectomy with corresponding perfusion abnormalities identified by all reviewers on both DECT and SPECT-CT V/Q in all resected lobes. CONCLUSION: DECT is a feasible technique that could be considered as an alternative for SPECT-CT V/Q for lung perfusion evaluation in infants.


Asunto(s)
Tomografía Computarizada de Emisión de Fotón Único , Gammagrafía de Ventilacion-Perfusión , Niño , Humanos , Lactante , Pulmón/diagnóstico por imagen , Perfusión , Proyectos Piloto , Tomografía Computarizada de Emisión de Fotón Único/métodos , Gammagrafía de Ventilacion-Perfusión/métodos
18.
Radiographics ; 41(4): 1186-1207, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34086496

RESUMEN

Most pediatric masses in the chest are located in the mediastinum. These masses are often initially detected incidentally on chest radiographs in asymptomatic children, although some patients may present with respiratory symptoms. At chest radiography, the mediastinum has been anatomically divided into anterior, middle, and posterior compartments. However, with the International Thymic Malignancy Interest Group classification scheme, which is based on cross-sectional imaging findings, the mediastinum is divided into prevascular, visceral, and paravertebral compartments. In the prevascular compartment, tumors of thymic origin, lymphomas, germ cell tumors, and vascular tumors are encountered. In the visceral compartment, lymphadenopathy and masses related to the foregut are seen. In the paravertebral compartment, neurogenic tumors are most common. Using the anatomic location in combination with knowledge of the imaging and pathologic features of pediatric mediastinal masses aids in accurate diagnosis of these masses to guide treatment and management decisions. An invited commentary by Lee and Winant is available online. ©RSNA, 2021.


Asunto(s)
Linfoma , Neoplasias del Mediastino , Neoplasias del Timo , Niño , Humanos , Neoplasias del Mediastino/diagnóstico por imagen , Mediastino/diagnóstico por imagen , Neoplasias del Timo/diagnóstico por imagen , Tomografía Computarizada por Rayos X
19.
Clin Imaging ; 75: 111-118, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33524938

RESUMEN

OBJECTIVE: To characterize the normal progression of quantitative CT parameters in normal children from birth to adulthood. MATERIALS AND METHODS: Patients aged 0-18 years with non-contrast-enhanced chest CT and evidence of normal lung parenchyma were included. Patients with respiratory symptoms, incomplete anthropometric measurements, or sub-optimal imaging technique were excluded. Segmentation was performed using an open-source software with an automated threshold segmentation. The following parameters were obtained: mean lung density, kurtosis, skewness, lung volume, and mass. Linear and exponential regression models were calculated with age and height as independent variables. A p-value of <0.05 was considered significant. RESULTS: 220 patients (111 females, 109 males) were included. Mean age was 9.6 ± 5.9 years and mean height was 133.9 ± 35.1 cm. Simple linear regression showed a significant relationship between mean lung density with age (R 2 = 0.70) and height (R 2 = 0.73). Kurtosis displayed a significant exponential correlation with age (R 2 = 0.70) and height (R 2 = 0.71). Skewness showed a significant exponential correlation with age (R 2 = 0.71) and height (R 2 = 0.73). Lung mass showed a correlation with age (R 2 = 0.93) and height (R 2 = 0.92). Exponential regression showed a significant relationship between lung volume with age (R 2 = 0.88) and height (R 2 = 0.93). CONCLUSION: Quantitative CT parameters of the lung parenchyma demonstrate changes from birth to adulthood. As children grow, the mean lung density decreases, and the lung parenchyma becomes more homogenous.


Asunto(s)
Enfermedades Pulmonares , Pulmón , Adolescente , Adulto , Niño , Preescolar , Femenino , Humanos , Pulmón/diagnóstico por imagen , Masculino , Valores de Referencia , Tomografía Computarizada por Rayos X
20.
AJR Am J Roentgenol ; 216(3): 781-790, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33474982

RESUMEN

OBJECTIVE. The purpose of this article is to review currently available and emerging techniques for pediatric lung MRI for general radiologists. CONCLUSION. MRI is a radiation-free alternative to CT, and clearly understanding the strengths and limitations of established and emerging techniques of pediatric lung MRI can allow practitioners to select and combine the optimal techniques, apply them in clinical practice, and potentially improve early diagnostic accuracy and patient management.


Asunto(s)
Enfermedades Pulmonares/diagnóstico por imagen , Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Adolescente , Artefactos , Contencion de la Respiración , Niño , Preescolar , Fibrosis Quística/diagnóstico por imagen , Femenino , Análisis de Fourier , Humanos , Lactante , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/secundario , Imagen por Resonancia Magnética/tendencias , Masculino , Atelectasia Pulmonar/prevención & control , Rabdomiosarcoma/diagnóstico por imagen , Rabdomiosarcoma/secundario
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA