Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Ugeskr Laeger ; 184(51)2022 12 19.
Artículo en Danés | MEDLINE | ID: mdl-36621878

RESUMEN

This case report describes an atypical progression of pregnancy in a woman who was infected with COVID-19 in her second trimester and initially presented with signs of absent foetal movements. The foetus was diagnosed with severe intrauterine growth restriction and abnormal foetal Doppler flows. The condition slowly improved over months, and the pregnancy was terminated with an acute caesarean section in gestational week 35. Placenta was tested negative for SARS-CoV-2-nucleocapsid. Four days old, the child was found COVID-19-positive, but remained asymptomatic. This case is a rare example considering the improvement of placental function over time.


Asunto(s)
COVID-19 , Complicaciones Infecciosas del Embarazo , Humanos , Niño , Embarazo , Femenino , COVID-19/complicaciones , Placenta/diagnóstico por imagen , Retardo del Crecimiento Fetal , Cesárea/efectos adversos , SARS-CoV-2 , Complicaciones Infecciosas del Embarazo/diagnóstico por imagen , Complicaciones Infecciosas del Embarazo/tratamiento farmacológico
2.
Undersea Hyperb Med ; 48(1): 33-42, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33648031

RESUMEN

Introduction: This study aimed to assess the capability of a pulse CO-oximeter to continuously monitor carboxyhemoglobin (COHb) during hyperbaric oxygen (HBO2) therapy. We estimated limits of agreement (LOA) between blood gas analysis and pulse CO-oximeter for COHb during HBO2 therapy in patients suffering from acute CO poisoning. Furthermore, we did a medicotechnical evaluation of the pulse CO-oximeter in hyperbaric conditions. Methods: We conducted a prospective, non-clinical, observational study in which we included n=10 patients with acute CO poisoning referred for HBO2 therapy. We did five repeated measurements of COHb for each patient during the HBO2 therapy. Bland-Altman analysis for multiple observations per individual was used to assess the agreement. The a priori LOA was ±6% for COHb. For the medicotechnical evaluation continuous measurements were obtained throughout each complete HBO2 therapy. The measurements were visually inspected and evaluated. Results: The Bland-Altman analysis showed that the pulse CO-oximeter overestimated COHb by 2.9 % [±1.0%] and the LOA was ±7.3% [±1.8%]. The continuous measurements by pulse CO-oximetry showed fluctuating levels of COHb and summarized saturations reached levels above 100%. Measurements were not affected by changes in pressure. Conclusion: To our knowledge, this study is the first to assess LOA and demonstrate use of a non-invasive method to measure COHb during HBO2 therapy. The pulse CO-oximeter performed within the manufactures reported LOA (±6%) despite hyperbaric conditions and was unaffected by changes in pressure. However, summarized saturations reached levels above 100%.


Asunto(s)
Intoxicación por Monóxido de Carbono/sangre , Intoxicación por Monóxido de Carbono/terapia , Carboxihemoglobina/análisis , Oxigenoterapia Hiperbárica , Oximetría/instrumentación , Adulto , Análisis de los Gases de la Sangre , Dinamarca , Femenino , Semivida , Humanos , Masculino , Oximetría/métodos , Estudios Prospectivos , Pigmentación de la Piel
3.
Cochrane Database Syst Rev ; 2: CD005370, 2016 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-26858174

RESUMEN

BACKGROUND: Critical illness is associated with uncontrolled inflammation and vascular damage which can result in multiple organ failure and death. Antithrombin III (AT III) is an anticoagulant with anti-inflammatory properties but the efficacy and any harmful effects of AT III supplementation in critically ill patients are unknown. This review was published in 2008 and updated in 2015. OBJECTIVES: To examine:1. The effect of AT III on mortality in critically ill participants.2. The benefits and harms of AT III.We investigated complications specific and not specific to the trial intervention, bleeding events, the effect on sepsis and disseminated intravascular coagulation (DIC) and the length of stay in the intensive care unit (ICU) and in hospital in general. SEARCH METHODS: We searched the following databases from inception to 27 August 2015: Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE (Ovid SP), EMBASE (Ovid SP,), CAB, BIOSIS and CINAHL. We contacted the main authors of trials to ask for any missed, unreported or ongoing trials. SELECTION CRITERIA: We included randomized controlled trials (RCTs) irrespective of publication status, date of publication, blinding status, outcomes published, or language. We contacted the investigators and the trial authors in order to retrieve missing data. In this updated review we include trials only published as abstracts. DATA COLLECTION AND ANALYSIS: Our primary outcome measure was mortality. Two authors each independently abstracted data and resolved any disagreements by discussion. We presented pooled estimates of the intervention effects on dichotomous outcomes as risk ratios (RR) with 95% confidence intervals (CI). We performed subgroup analyses to assess risk of bias, the effect of AT III in different populations (sepsis, trauma, obstetrics, and paediatrics), and the effect of AT III in patients with or without the use of concomitant heparin. We assessed the adequacy of the available number of participants and performed trial sequential analysis (TSA) to establish the implications for further research. MAIN RESULTS: We included 30 RCTs with a total of 3933 participants (3882 in the primary outcome analyses).Combining all trials, regardless of bias, showed no statistically significant effect of AT III on mortality with a RR of 0.95 (95% CI 0.88 to 1.03), I² statistic = 0%, fixed-effect model, 29 trials, 3882 participants, moderate quality of evidence). For trials with low risk of bias the RR was 0.96 (95% Cl 0.88 to 1.04, I² statistic = 0%, fixed-effect model, 9 trials, 2915 participants) and for high risk of bias RR 0.94 (95% Cl 0.77 to 1.14, I² statistic = 0%, fixed-effect model, 20 trials, 967 participants).For participants with severe sepsis and DIC the RR for mortality was non-significant, 0.95 (95% Cl 0.88 to 1.03, I² statistic = 0%, fixed-effect model, 12 trials, 2858 participants, moderate quality of evidence).We conducted 14 subgroup and sensitivity analyses with respect to the different domains of risk of bias, but detected no statistically significant benefit in any subgroup analyses.Our secondary objective was to assess the benefits and harms of AT III. For complications specific to the trial intervention the RR was 1.26 (95% Cl 0.83 to 1.92, I² statistic = 0%, random-effect model, 3 trials, 2454 participants, very low quality of evidence). For complications not specific to the trial intervention, the RR was 0.71 (95% Cl 0.08 to 6.11, I² statistic = 28%, random-effects model, 2 trials, 65 participants, very low quality of evidence). For complications other than bleeding, the RR was 0.72 ( 95% Cl 0.42 to 1.25, I² statistic = 0%, fixed-effect model, 3 trials, 187 participants, very low quality of evidence). Eleven trials investigated bleeding events and we found a statistically significant increase, RR 1.58 (95% CI 1.35 to 1.84, I² statistic = 0%, fixed-effect model, 11 trials, 3019 participants, moderate quality of evidence) in the AT III group. The amount of red blood cells administered had a mean difference (MD) of 138.49 (95% Cl -391.35 to 668.34, I² statistic = 84%, random-effect model, 4 trials, 137 participants, very low quality of evidence). The effect of AT III in patients with multiple organ failure (MOF) was a MD of -1.24 (95% Cl -2.18 to -0.29, I² statistic = 48%, random-effects model, 3 trials, 156 participants, very low quality of evidence) and for patients with an Acute Physiology and Chronic Health Evaluation score (APACHE) at II and III the MD was -2.18 (95% Cl -4.36 to -0.00, I² statistic = 0%, fixed-effect model, 3 trials, 102 participants, very low quality of evidence). The incidence of respiratory failure had a RR of 0.93 (95% Cl 0.76 to 1.14, I² statistic = 32%, random-effects model, 6 trials, 2591 participants, moderate quality of evidence). AT III had no statistically significant impact on the duration of mechanical ventilation (MD 2.20 days, 95% Cl -1.21 to 5.60, I² statistic = 0%, fixed-effect model, 3 trials, 190 participants, very low quality of evidence); on the length of stay in the ICU (MD 0.24, 95% Cl -1.34 to 1.83, I² statistic = 0%, fixed-effect model, 7 trials, 376 participants, very low quality of evidence) or on the length of stay in hospital in general (MD 1.10, 95% Cl -7.16 to 9.36), I² statistic = 74%, 4 trials, 202 participants, very low quality of evidence). AUTHORS' CONCLUSIONS: There is insufficient evidence to support AT III substitution in any category of critically ill participants including the subset of patients with sepsis and DIC. We did not find a statistically significant effect of AT III on mortality, but AT III increased the risk of bleeding events. Subgroup analyses performed according to duration of intervention, length of follow-up, different patient groups, and use of adjuvant heparin did not show differences in the estimates of intervention effects. The majority of included trials were at high risk of bias (GRADE; very low quality of evidence for most of the analyses). Hence a large RCT of AT III is needed, without adjuvant heparin among critically ill patients such as those with severe sepsis and DIC, with prespecified inclusion criteria and good bias protection.


Asunto(s)
Antiinflamatorios/uso terapéutico , Anticoagulantes/uso terapéutico , Antitrombina III/uso terapéutico , Enfermedad Crítica/mortalidad , Antiinflamatorios/efectos adversos , Anticoagulantes/efectos adversos , Antitrombina III/efectos adversos , Humanos , Ensayos Clínicos Controlados Aleatorios como Asunto
4.
Intensive Care Med ; 42(4): 505-520, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26862016

RESUMEN

PURPOSE: Antithrombin III (AT III) is an anticoagulant with anti-inflammatory properties. We assessed the benefits and harms of AT III in critically ill patients. METHODS: We searched from inception to 27 August 2015 in CENTRAL, MEDLINE, EMBASE, CAB, BIOSIS and CINAHL. We included randomized controlled trials (RCTs) irrespective of publication status, date of publication, blinding status, outcomes published or language. RESULTS: We included 30 RCTs with a total of 3933 participants. The majority of included trials were at high risk of bias. Combining all trials, regardless of bias, showed no statistically significant effect of AT III on mortality (RR 0.95, 95% CI 0.88-1.03, I (2) = 0%, fixed-effect model, 29 trials, 3882 participants). Among those with severe sepsis and disseminated intravascular coagulation (DIC), AT III showed no impact on mortality (RR 0.95, 95% Cl 0.88-1.03, I (2) = 0%, fixed-effect model, 12 trials, 2858 participants). We carried out multiple subgroup and sensitivity analyses to assess the benefits and harms of AT III and to examine the impact of risk of bias. AT III significantly increased bleeding events (RR 1.58, 95% CI 1.35-1.84, I (2) = 0%, fixed-effect model, 11 trials, 3019 participants). However, for all other outcome measures and analyses, the results did not reach statistical significance. CONCLUSIONS: There is insufficient evidence to support AT III substitution in any category of critically ill participants including those with sepsis and DIC. AT III did not show an impact on mortality, but increased the risk of bleeding.


Asunto(s)
Antitrombina III/uso terapéutico , Antitrombinas/uso terapéutico , Enfermedad Crítica/mortalidad , Coagulación Intravascular Diseminada/tratamiento farmacológico , Coagulación Intravascular Diseminada/mortalidad , Humanos , Ensayos Clínicos Controlados Aleatorios como Asunto , Sepsis/tratamiento farmacológico , Sepsis/mortalidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA