Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 98
Filtrar
1.
CJC Open ; 6(4): 649-655, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38708054

RESUMEN

Background: Leadless pacing has been established as an alternative approach to transvenous devices for selected patients. Often, leadless pacemaker (LP) implantation is a de novo procedure, but in an increasing number of patients, an LP is used after previous implantation of a conventional pacing system (CPS). Methods: A retrospective analysis was conducted of the efficacy and safety of LP implantation in the context of a previously implanted CPS, from 2 large Swiss centres. Results: A total of 257 consecutive patients undergoing LP implantation were included. They were divided into 2 groups: group 1 consisted of 233 patients who did not have a previous CPS, and group 2 consisted of 24 patients with an in situ CPS. In group 2, a total of 20 patients (83%) required transvenous lead extraction due to infection, malfunction, or other reasons. In 3 patients with device-related infection, lead extraction and LP implantation was performed as a single procedure, whereas in the remaining 11 cases, a time window occurred between the 2 procedures (median: 11.5 days; range: 2-186 days). Electrical device parameters at implantation and during follow-up did not differ between the 2 groups (mean: 12.5 ± 9.3 months). Eight major periprocedural complications (3.1%) were encountered (4 pericardial effusions, 3 instances of femoral bleeding, and 1 instance of intra-abdominal bleeding) in the entire cohort within a 30-day period. No complications occurred in the group with a previous device. No infections were registered, even when complete extraction of an infected CPS was performed prior to LP implantation. Conclusions: Implantation of an LP in patients with a prior CPS (with or without extraction of the previous system) was effective and safe in our population of patients.


Contexte: La stimulation cardiaque sans fil a été établie comme une solution de substitution aux dispositifs transveineux chez certains patients. L'implantation d'un stimulateur cardiaque sans fil est souvent une intervention de novo, mais chez un nombre croissant de patients, ce type de stimulateur est utilisé après l'implantation d'un stimulateur classique. Méthodologie: Une analyse rétrospective de l'efficacité et de l'innocuité de la stimulation cardiaque sans fil dans le contexte de l'implantation d'un stimulateur classique a été réalisée dans deux grands centres suisses. Résultats: Un total de 257 patients consécutifs ayant subi l'implantation d'un stimulateur cardiaque sans fil ont été inclus. Les patients étaient répartis dans deux groupes; le groupe 1 était composé de 233 patients non porteurs d'un stimulateur classique, et le groupe 2, de 24 patients porteurs d'un stimulateur classique in situ. Dans le groupe 2, 20 patients au total (83 %) ont eu besoin d'une extraction de la sonde transveineuse en raison d'une infection, d'un défaut de fonctionnement, ou pour d'autres motifs. Chez 3 patients présentant une infection liée au stimulateur, l'extraction de la sonde et l'implantation d'un stimulateur cardiaque sans fil ont été réalisées simultanément, tandis que dans les 11 autres cas, il s'est écoulé un temps médian de 11,5 jours entre les deux interventions (min.-max. : 2-186 jours). Les paramètres relatifs au dispositif électrique au moment de l'implantation et pendant le suivi n'étaient pas différents entre les deux groupes (moyenne : 12,5 ± 9,3 mois). Huit complications périopératoires importantes (3,1 %) sont survenues (4 cas d'épanchement péricardique, 3 cas d'hémorragie fémorale et 1 cas d'hémorragie intra-abdominale) dans l'ensemble de la cohorte au cours d'une période de 30 jours. Aucune complication ne s'est produite dans le groupe de patients porteurs d'un stimulateur classique. On n'a enregistré aucun cas d'infection, même lorsque l'extraction complète du stimulateur classique infecté a été effectuée avant l'implantation du stimulateur cardiaque sans fil. Conclusions: L'implantation d'un stimulateur cardiaque sans fil chez les patients porteurs d'un stimulateur classique (avec ou sans extraction de ce stimulateur) était une intervention efficace et sûre dans cette population de patients.

2.
CJC Open ; 6(2Part A): 96-103, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38585679

RESUMEN

Background: Impairment of the conduction system is a common complication of transcatheter aortic valve replacement (TAVR), which is typically performed in elderly patients. A leadless pacemaker (LP) may be a suitable option in this frail population, but the available scientific data concerning the efficacy and safety of leadless pacing after TAVR are sparse. The purpose of this analysis was to evaluate the efficacy and safety of LP implantation in patients with relevant bradycardias after TAVR, compared to other indications. Methods: Consecutive patients were retrospectively enrolled. Demographics, background heart diseases, interventional parameters, and follow-up data were collected. Results: A total of 257 consecutive patients who underwent LP implantation were included. In 26 patients, the device was implanted due to bradycardias after TAVR (TAVR group), whereas the remaining 231 patients were in the population without previous TAVR (non-TAVR group). The mean implantation duration (56 ± 22 minutes in the TAVR group vs 48 ± 20 minutes in the non-TAVR group; P = not significant [NS]) and the implantation success rate (100% in the TAVR group vs 98.7% in the non-TAVR group; P = NS) were similar in the 2 cohorts. No significant differences occurred in pacing parameters (sensing, impedance, and threshold, respectively) between the 2 groups, either at implantation or during follow-up. A total of 8 major periprocedural complications (3.1% of patients in total; 3.8% in the TAVR group vs 3.0% in the non-TAVR group; P = NS) occurred within 30 days, without significant difference between the 2 groups. Conclusions: LP implantation appears to be safe and effective in patients after TAVR, and therefore, this procedure is a suitable option for this often old and frail population.


Contexte: L'atteinte du système de conduction cardiaque est une complication courante du remplacement valvulaire aortique par cathéter (RVAC), une intervention habituellement pratiquée chez les patients âgés. Un stimulateur cardiaque sans sonde peut être une option convenable pour cette population fragile, mais les données scientifiques actuelles concernant l'efficacité et l'innocuité de la stimulation sans sonde après un RVAC sont fragmentaires. Cette analyse visait à évaluer l'efficacité et l'innocuité de l'implantation d'un stimulateur cardiaque sans sonde chez des patients atteints de bradycardies pertinentes après un RVAC, comparativement à d'autres indications. Méthodologie: Des patients consécutifs ont été recrutés de manière rétrospective. Les données démographiques, les maladies cardiaques sous-jacentes, les paramètres interventionnels et les données de suivi ont été colligés. Résultats: Un total de 257 patients consécutifs qui se sont fait implanter un stimulateur cardiaque sans sonde ont été inclus. Chez 26 patients, le dispositif a été implanté en raison d'une bradycardie après un RVAC (groupe RVAC), alors que les 231 autres patients formaient la population sans RVAC antérieur (groupe sans RVAC). La durée moyenne de l'intervention d'implantation (56 ± 22 minutes dans le groupe RVAC vs 48 ± 20 minutes dans le groupe sans RVAC; p = non significatif [NS]) et le taux de réussite de l'implantation (100 % dans le groupe RVAC vs 98,7 % dans le groupe sans RVAC; p = NS) étaient similaires dans les deux cohortes. Aucune différence significative n'a été observée dans les paramètres de stimulation (sensibilité, impédance et seuil, respectivement) entre les 2 groupes, que ce soit au moment de l'implantation ou pendant le suivi. Un total de 8 complications périopératoires majeures (3,1 % de l'ensemble des patients; 3,8 % dans le groupe RVAC vs 3,0 % dans le groupe sans RVAC; p = NS) sont survenues dans les 30 jours, sans différence notable entre les 2 groupes. Conclusions: L'implantation d'un stimulateur cardiaque sans sonde semble sûre et efficace après un RVAC; par conséquent, cette intervention représente une option convenable pour cette population souvent âgée et fragile.

3.
J Clin Med ; 12(16)2023 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-37629216

RESUMEN

BACKGROUND: Device patients may require upgrade interventions from simpler to more complex cardiac implantable electronic devices. Prior to upgrading interventions, clinicians need to balance the risks and benefits of transvenous lead extraction (TLE), additional lead implantation or lead abandonment. However, evidence on procedural outcomes of TLE at the time of device upgrade is scarce. METHODS: This is a post hoc analysis of the investigator-initiated multicenter Swiss TLE registry. The objectives were to assess patient and procedural factors influencing TLE outcomes at the time of device upgrades. RESULTS: 941 patients were included, whereof 83 (8.8%) had TLE due to a device upgrade. Rotational mechanical sheaths were more often used in upgraded patients (59% vs. 42.7%, p = 0.015) and total median procedure time was longer in these patients (160 min vs. 105 min, p < 0.001). Clinical success rates of upgraded patients compared to those who received TLE due to other reasons were not different (97.6% vs. 93.0%, p = 0.569). Moreover, multivariable analysis showed that upgrade procedures were not associated with a greater risk for complications (HR 0.48, 95% confidence interval 0.14-1.57, p = 0.224; intraprocedural complication rate of upgraded patients 7.2% vs. 5.5%). Intraprocedural complications of upgraded patients were mostly associated with the implantation and not the extraction procedure (67% vs. 33% of complications). CONCLUSIONS: TLE during device upgrade is effective and does not attribute a disproportionate risk to the upgrade procedure.

4.
Cardiology ; 148(5): 441-447, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37487479

RESUMEN

INTRODUCTION: Long-term complication rates in standard transvenous pacemakers are reported around 4-12% with a higher incidence in the elderly population. We report our experience in octogenarians undergoing leadless pacemaker implantation in two large-volume centers in Switzerland. METHODS: Consecutive patients undergoing leadless pacemaker implantation at two Swiss large volume centers (University Hospital Zurich, Zurich and Cardiocentro Ticino Institute, Lugano) between October 2015 and March 2020 were included in this retrospective analysis. Demographic information, clinical data, and procedural characteristics were recorded at the day of implantation and during follow-up. RESULTS: Two hundred and twenty patients (mean age 80.6 ± 7.7 years, male 66%) were included. The main indication for pacemaker implantation was slow ventricular rate atrial fibrillation (111 of 220 patients, 50.4%). Out of the 220 patients, 124 (56.3%) were ≥80 years. Overall successful implantation rate was 98.6%. In the octogenarian population, the median procedure time (45 ± 20.2 min vs. 40 ± 19.6 min, p = 0.03) and radiation duration (6.1 ± 8.2 min vs. 5.0 ± 7.2 min, p = 0.03) were longer compared to patients <80 years. Major complications (2.7%, n = 6) and device measurements during follow-up were similar between patients ≥80 and <80 years. CONCLUSION: Implantation of a leadless pacemaker device in octogenarians is safe and effective with a similarly low complication rate compared to non-octogenarians.


Asunto(s)
Fibrilación Atrial , Marcapaso Artificial , Anciano de 80 o más Años , Humanos , Masculino , Anciano , Octogenarios , Estudios Retrospectivos , Resultado del Tratamiento , Fibrilación Atrial/terapia , Fibrilación Ventricular , Diseño de Equipo
5.
J Clin Med ; 12(14)2023 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-37510929

RESUMEN

INTRODUCTION: Data on peri-operative management of direct-acting oral anticoagulants (DOACs) during transcatheter pacing leadless system (TPS) implantations remain limited. This study aimed to evaluate a standardized DOAC management regime consisting of interruption of a single dose prior to implantation and reinitiation within 6-24 h; also, patient clinical characteristics associated with this approach were identified. METHOD: Consecutive patients undergoing standard TPS implantation procedures from two Swiss tertiary centers were included. DOAC peri-operative management included the standardized approach (Group 1A) or other approaches (Group 1B). RESULTS: Three hundred and ninety-two pts (mean age 81.4 ± 7.3 years, 66.3% male, left ventricular ejection fraction 55.5 ± 9.6%) underwent TPS implantation. Two hundred and eighty-two pts (71.9%) were under anticoagulation therapy; 192 pts were treated with DOAC; 90 pts were under vitamin-K antagonist. Patients treated with DOAC less often had structural heart disease, diabetes mellitus, and advanced renal failure. The rate of major peri-procedural complications did not differ between groups 1A (n = 115) and 1B (n = 77) (2.6% and 3.8%, p = 0.685). Compared to 1B, 1A patients were implanted with TPS for slow ventricular rate atrial fibrillation (AF) (p = 0.002), in a better overall clinical status, and implanted electively (<0.001). CONCLUSIONS: Standardized peri-procedural DOAC management was more often implemented for elective TPS procedures and did not seem to increase bleeding or thromboembolic adverse events.

7.
Europace ; 25(2): 546-553, 2023 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-36106562

RESUMEN

AIMS: Electromechanical coupling in patients receiving cardiac resynchronization therapy (CRT) is not fully understood. Our aim was to determine the best combination of electrical and mechanical substrates associated with effective CRT. METHODS AND RESULTS: Sixty-two patients were prospectively enrolled from two centres. Patients underwent 12-lead electrocardiogram (ECG), cardiovascular magnetic resonance (CMR), echocardiography, and anatomo-electromechanical mapping (AEMM). Remodelling was measured as the end-systolic volume (ΔESV) decrease at 6 months. CRT was defined effective with ΔESV ≤ -15%. QRS duration (QRSd) was measured from ECG. Area strain was obtained from AEMM and used to derive systolic stretch index (SSI) and total left-ventricular mechanical time. Total left-ventricular activation time (TLVAT) and transeptal time (TST) were derived from AEMM and ECG. Scar was measured from CMR. Significant correlations were observed between ΔESV and TST [rho = 0.42; responder: 50 (20-58) vs. non-responder: 33 (8-44) ms], TLVAT [-0.68; 81 (73-97) vs. 112 (96-127) ms], scar [-0.27; 0.0 (0.0-1.2) vs. 8.7 (0.0-19.1)%], and SSI [0.41; 10.7 (7.1-16.8) vs. 4.2 (2.9-5.5)], but not QRSd [-0.13; 155 (140-176) vs. 167 (155-177) ms]. TLVAT and SSI were highly accurate in identifying CRT response [area under the curve (AUC) > 0.80], followed by scar (AUC > 0.70). Total left-ventricular activation time (odds ratio = 0.91), scar (0.94), and SSI (1.29) were independent factors associated with effective CRT. Subjects with SSI >7.9% and TLVAT <91 ms all responded to CRT with a median ΔESV ≈ -50%, while low SSI and prolonged TLVAT were more common in non-responders (ΔESV ≈ -5%). CONCLUSION: Electromechanical measurements are better associated with CRT response than conventional ECG variables. The absence of scar combined with high SSI and low TLVAT ensures effectiveness of CRT.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/métodos , Función Ventricular Izquierda/fisiología , Cicatriz , Bloqueo de Rama , Ecocardiografía , Electrocardiografía/métodos , Resultado del Tratamiento , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia
8.
Europace ; 25(2): 643-650, 2023 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-36352534

RESUMEN

AIMS: To investigate the role of genetic testing in patients with idiopathic atrioventricular conduction disease requiring pacemaker (PM) implantation before the age of 50 years. METHODS AND RESULTS: All consecutive PM implantations in Southern Switzerland between 2010 and 2019 were evaluated. Inclusion criteria were: (i) age at the time of PM implantation: < 50 years; (ii) atrioventricular block (AVB) of unknown aetiology. Study population was investigated by ajmaline challenge and echocardiographic assessment over time. Genetic testing was performed using next-generation sequencing panel, containing 174 genes associated to inherited cardiac diseases, and Sanger sequencing confirmation of suspected variants with clinical implication. Of 2510 patients who underwent PM implantation, 15 (0.6%) were young adults (median age: 44 years, male predominance) presenting with advanced AVB of unknown origin. The average incidence of idiopathic AVB computed over the 2010-2019 time window was 0.7 per 100 000 persons per year (95% CI 0.4-1.2). Most of patients (67%) presented with specific genetic findings (pathogenic variant) or variants of uncertain significance (VUS). A pathogenic variant of PKP2 gene was found in one patient (6.7%) with no overt structural cardiac abnormalities. A VUS of TRPM4, MYBPC3, SCN5A, KCNE1, LMNA, GJA5 genes was found in other nine cases (60%). Of these, three unrelated patients (20%) presented the same heterozygous missense variant c.2531G > A p.(Gly844Asp) in TRPM4 gene. Diagnostic re-assessment over time led to a diagnosis of Brugada syndrome and long-QT syndrome in two patients (13%). No cardiac events occurred during a median follow-up of 72 months. CONCLUSION: Idiopathic AVB in adults younger than 50 years is a very rare condition with an incidence of 0.7 per 100 000 persons/year. Systematic investigations, including genetic testing and ajmaline challenge, can lead to the achievement of a specific diagnosis in up to 20% of patients. Heterozygous missense variant c.2531G > A p.(Gly844Asp) in TRPM4 gene was found in an additional 20% of unrelated patients, suggesting possible association of the variant with the disease.


Asunto(s)
Bloqueo Atrioventricular , Marcapaso Artificial , Adulto Joven , Humanos , Masculino , Adulto , Persona de Mediana Edad , Femenino , Trastorno del Sistema de Conducción Cardíaco/complicaciones , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/epidemiología , Bloqueo Atrioventricular/genética , Marcapaso Artificial/efectos adversos , Pruebas Genéticas , Ajmalina
9.
J Clin Med ; 11(16)2022 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-36013022

RESUMEN

In recent years, the rate of pacemaker implantations has continued to rise throughout Europe [...].

10.
J Interv Card Electrophysiol ; 64(1): 129-135, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35059917

RESUMEN

PURPOSE: The miniaturized transcatheter pacing system (TPS) implant is performed using a 27 Fr sheath. Achieving femoral vein access hemostasis after sheath removal is of utmost importance. Feasibility and clinical effectiveness of double device-based suture-mediated closure technique (DualPerclose) were evaluated. METHODS: Patients undergoing TPS positioning and treated with DualPerclose technique at our institution were considered. Feasibility of the DualPerclose technique included the rates of effective initial device suture fixation and effective hemostasis after sheath removal. Clinical efficacy considered intraprocedural and periprocedural bleeding events as well as midterm access site vascular injury assessed at 3 months using lower limb vascular ultrasonography. Data on all follow-up major adverse events were also collected. RESULTS: All patients (n = 83 patients; mean age 82.3 ± 7.1 years, 67.5% male gender, 85.5%, with structural heart disease, mean left ventricular ejection fraction 54.0 ± 9.6%, renal impairment in 31.3%) who underwent TPS positioning between November 2015 and February 2020 were considered. TPS positioning was successful in all patients. In 82 patients, the DualPerclose approach was utilized: 13 patients (15.8%) required > 2 devices to obtain effective fixing of 2 sutures; complete immediate hemostasis was achieved in 80 patients (97.6%). One (1.2%) severe groin-related bleeding event occurred. At midterm, 1 (1.2%) mildly symptomatic arteriovenous fistula was diagnosed (conservative treatment). Over a median follow-up of 22 (IQR 10-35.5) months, 14 (17.1%) major adverse events were recorded, including 1 loss of capture requiring TPS replacement and 5 deaths. CONCLUSION: Femoral vein access closure using dual Perclose Proglide devices during TPS is feasible and clinically effective.


Asunto(s)
Marcapaso Artificial , Dispositivos de Cierre Vascular , Anciano , Anciano de 80 o más Años , Estudios de Factibilidad , Femenino , Hemorragia/etiología , Hemorragia/prevención & control , Hemostasis , Técnicas Hemostáticas/efectos adversos , Humanos , Masculino , Volumen Sistólico , Técnicas de Sutura , Suturas , Resultado del Tratamiento , Dispositivos de Cierre Vascular/efectos adversos , Función Ventricular Izquierda
11.
Front Cardiovasc Med ; 9: 1011619, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36684577

RESUMEN

Management of hemodynamically stable, incessant wide QRS complex tachycardia (WCT) in patients who already have an implantable cardioverter defibrillator (ICD) is challenging. First-line treatment is performed by medical staff who have no knowledge on programmed ICD therapy settings and there is always some concern for unexpected ICD shock. In these patients, a structured approach is necessary from presentation to therapy. The present review provides a systematic approach in four distinct phases to guide any physician involved in the management of these patients: PHASE I: assessment of hemodynamic status and use of the magnet to temporarily suspend ICD therapies, especially shocks; identification of possible arrhythmia triggers; risk stratification in case of electrical storm (ES). PHASE II: The preparation phase includes reversal of potential arrhythmia "triggers", mild patient sedation, and patient monitoring for therapy delivery. Based on resource availability and competences, the most adequate therapeutic approach is chosen. This choice depends on whether a device specialist is readily available or not. In the case of ES in a "high-risk" patient an accelerated patient management protocol is advocated, which considers urgent ventricular tachycardia transcatheter ablation with or without mechanical cardiocirculatory support. PHASE III: Therapeutic phase is based on the use of intravenous anti-arrhythmic drugs mostly indicated in this clinical context are presented. Device interrogation is very important in this phase when sustained monomorphic VT diagnosis is confirmed, then ICD ATP algorithms, based on underlying VT cycle length, are proposed. In high-risk patients with intractable ES, intensive patient management considers MCS and transcatheter ablation. PHASE IV: The patient is hospitalized for further diagnostics and management aimed at preventing arrhythmia recurrences.

12.
Europace ; 23(11): 1751-1756, 2021 11 08.
Artículo en Inglés | MEDLINE | ID: mdl-34534277

RESUMEN

AIMS: Data regarding the efficacy of catheter ablation in heart failure patients with severely dilated left atrium and reduced left ventricular ejection fraction (LVEF) are scanty. We sought to assess the efficacy of catheter ablation in patients with reduced LVEF and severe left atrial (LA) enlargement, and to compare it to those patients with preserved left ventricular function and equally dilated left atrium. METHODS AND RESULTS: Three patient groups with paroxysmal or persistent atrial fibrillation (AF) undergoing a first pulmonary vein isolation (PVI) were considered: Group 1 included patients with normal or mildly abnormal LA volume (≤41 mL/m2) and normal LVEF; Group 2 included patients with severe LA enlargement (>48 mL/m2) and normal LVEF; and Group 3 included patients with severe LA enlargement and reduced LVEF. Time to event analysis was used to investigate AF recurrences. The study cohort includes 439 patients; Group 3 had a higher prevalence of cardiovascular risk factors. LA enlargement was associated with a two-fold in risk of AF recurrence, on the contrary only a smaller non-significant increase of 30% was shown with the further addition of LVEF reduction. CONCLUSIONS: The long-term outcome of patients with severe LA dilatation and reduced LVEF is comparable to those with severe LA enlargement but preserved LVEF. Long-term efficacy of PVI is certainly affected by the enlargement of the left atrium, but less so by the addition of a reduced LVEF. CA remains the best strategy for rhythm control both in paroxysmal and persistent AF in this subgroup of patients.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Humanos , Venas Pulmonares/cirugía , Recurrencia , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
13.
J Am Heart Assoc ; 10(2): e018572, 2021 01 19.
Artículo en Inglés | MEDLINE | ID: mdl-33410337

RESUMEN

Background Short ECG P-wave duration has recently been demonstrated to be associated with higher risk of atrial fibrillation (AF). The aim of this study was to assess the rate of AF recurrence after pulmonary vein isolation in patients with a short P wave, and to mechanistically elucidate the observation by computer modeling. Methods and Results A total of 282 consecutive patients undergoing a first single-pulmonary vein isolation procedure for paroxysmal or persistent AF were included. Computational models studied the effect of adenosine and sodium conductance on action potential duration and P-wave duration (PWD). About 16% of the patients had a PWD of 110 ms or shorter (median PWD 126 ms, interquartile range, 115 ms-138 ms; range, 71 ms-180 ms). At Cox regression, PWD was significantly associated with AF recurrence (P=0.012). Patients with a PWD <110 ms (hazard ratio [HR], 2.20; 95% CI, 1.24-3.88; P=0.007) and patients with a PWD ≥140 (HR, 1.87, 95% CI, 1.06-3.30; P=0.031) had a nearly 2-fold increase in risk with respect to the other group. In the computational model, adenosine yielded a significant reduction of action potential duration 90 (52%) and PWD (7%). An increased sodium conductance (up to 200%) was robustly accompanied by an increase in conduction velocity (26%), a reduction in action potential duration 90 (28%), and PWD (22%). Conclusions One out of 5 patients referred for pulmonary vein isolation has a short PWD which was associated with a higher rate of AF after the index procedure. Computer simulations suggest that shortening of atrial action potential duration leading to a faster atrial conduction may be the cause of this clinical observation.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial , Ablación por Catéter , Electrocardiografía/métodos , Sistema de Conducción Cardíaco , Complicaciones Posoperatorias , Potenciales de Acción/efectos de los fármacos , Potenciales de Acción/fisiología , Adenosina/farmacología , Antiarrítmicos/farmacología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Simulación por Computador , Femenino , Sistema de Conducción Cardíaco/efectos de los fármacos , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/fisiopatología , Venas Pulmonares/cirugía , Recurrencia , Canales de Sodio/fisiología
14.
Europace ; 23(4): 640-647, 2021 04 06.
Artículo en Inglés | MEDLINE | ID: mdl-33241411

RESUMEN

AIMS: Non-invasive imaging of electrical activation requires high-density body surface potential mapping. The nine electrodes of the 12-lead electrocardiogram (ECG) are insufficient for a reliable reconstruction with standard inverse methods. Patient-specific modelling may offer an alternative route to physiologically constraint the reconstruction. The aim of the study was to assess the feasibility of reconstructing the fully 3D electrical activation map of the ventricles from the 12-lead ECG and cardiovascular magnetic resonance (CMR). METHODS AND RESULTS: Ventricular activation was estimated by iteratively optimizing the parameters (conduction velocity and sites of earliest activation) of a patient-specific model to fit the simulated to the recorded ECG. Chest and cardiac anatomy of 11 patients (QRS duration 126-180 ms, documented scar in two) were segmented from CMR images. Scar presence was assessed by magnetic resonance (MR) contrast enhancement. Activation sequences were modelled with a physiologically based propagation model and ECGs with lead field theory. Validation was performed by comparing reconstructed activation maps with those acquired by invasive electroanatomical mapping of coronary sinus/veins (CS) and right ventricular (RV) and left ventricular (LV) endocardium. The QRS complex was correctly reproduced by the model (Pearson's correlation r = 0.923). Reconstructions accurately located the earliest and latest activated LV regions (median barycentre distance 8.2 mm, IQR 8.8 mm). Correlation of simulated with recorded activation time was very good at LV endocardium (r = 0.83) and good at CS (r = 0.68) and RV endocardium (r = 0.58). CONCLUSION: Non-invasive assessment of biventricular 3D activation using the 12-lead ECG and MR imaging is feasible. Potential applications include patient-specific modelling and pre-/per-procedural evaluation of ventricular activation.


Asunto(s)
Electrocardiografía , Modelación Específica para el Paciente , Mapeo del Potencial de Superficie Corporal , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética
15.
Int J Cardiol ; 328: 247-249, 2021 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-33278416

RESUMEN

BACKGROUND: Remote monitoring (RM) technology embedded in cardiac rhythm devices permits continuous monitoring of device function, and recording of selected cardiac physiological parameters and cardiac arrhythmias and may be of utmost utility during Coronavirus (COVID-19) pandemic, when in-person office visit for regular follow-up were postponed. However, patients not alredy followed-up via RM represent a challenging group of patients to be managed during the lockdown. METHODS: We reviewed patient files scheduled for an outpatient visit between January 1, 2020 and May 11th, 2020 to assess the proportion of patients in whom RM activation was possible without office visit, and compared them to those scheduled for visit before the lockdown. RESULTS: During COVID-19 pandemic, RM activation was feasible in a minority of patients (7.8% of patients) expected at outpatient clinic for a follow-up visit and device check-up. This was possible in a good proportion of complex implantable devices such as cardiac resynchronization therapy and implantable cardioverter defibrillator but only in a minority of patients with a pacemaker the RM function could be activated during the period of restricted access to hospital. CONCLUSIONS: Our experience strongly suggest to consider the systematic activation of RM function at the time of implantation or - by default programming - in all cardiac rhythm management devices.


Asunto(s)
Arritmias Cardíacas/terapia , COVID-19/prevención & control , Dispositivos de Terapia de Resincronización Cardíaca/normas , Desfibriladores Implantables/normas , Tecnología de Sensores Remotos/normas , Anciano , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiología , COVID-19/epidemiología , Dispositivos de Terapia de Resincronización Cardíaca/tendencias , Control de Enfermedades Transmisibles/normas , Control de Enfermedades Transmisibles/tendencias , Desfibriladores Implantables/tendencias , Femenino , Estudios de Seguimiento , Humanos , Masculino , Pandemias/prevención & control , Tecnología de Sensores Remotos/tendencias
16.
Int J Cardiol ; 323: 113-117, 2021 01 15.
Artículo en Inglés | MEDLINE | ID: mdl-32916226

RESUMEN

BACKGROUND: Leadless pacemakers are an established treatment option for bradyarrhythmias. Similar to conventional transvenous pacemakers, satisfying pacing values during implantation are targeted for optimal long-term device function. The objective is to investigate the role of a local injury current (IC) in leadless pacemaker implantations. METHOD: The IC, sensing value, capture threshold and impedance were collected in 30 consecutive patients receiving a leadless pacemaker. RESULTS: 39 EGMs were recorded from 30 patients (including 9 device repositions). An IC was detected in 15 cases (38%). At implantation, the presence of an IC was associated with a significantly lower sensing (7.1 ± 3.7 mV vs 12.0 ± 4.0 mV; P = 0.004) and a higher capture threshold (median threshold 1.13 V at 0.24 ms [0.50-2.00] vs 0.50 V at 0.24 ms [0.25-0.75]; P = 0.002) and with a 26 fold higher likelihood of device repositioning compared to the absence of an IC (OR 26.3 [2.79-248], P < 0.001). Patients with an IC in their final implant position had a lower sensing (9.3 ± 4.4 mV vs 13.6 ± 4.7 mV at implantation, P = 0.04), while the initially similar capture threshold was lower after 24 h in the IC group. After 2 weeks, all parameters were similar between the two groups. CONCLUSIONS: Our study shows that an IC can readily be observed during leadless pacemaker implantation associated with a lower sensing and a higher capture threshold at implantation but with similar to even better values during follow-up.


Asunto(s)
Marcapaso Artificial , Bradicardia/diagnóstico , Bradicardia/terapia , Estimulación Cardíaca Artificial , Diseño de Equipo , Humanos , Resultado del Tratamiento
17.
Europace ; 22(11): 1653-1658, 2020 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-32830231

RESUMEN

AIMS: To assess the value of high-density mapping (HDM) in revealing undetected incomplete pulmonary vein isolation (PVI) after the fourth-generation cryoballoon (CB4G) ablation compared to the previous cryoballoon's versions. METHODS AND RESULTS: Consecutive patients with paroxysmal or early-persistent atrial fibrillation (AF) undergoing CB ablation as the index procedure, assisted by HDM, were retrospectively included in this study. A total of 68 patients (52 males; mean age: 60 ± 12 years, 58 paroxysmal AF) were included, and a total of 272 veins were mapped. Fourth-generation cryoballoon with the new spiral mapping catheter (SMC) was used in 35 patients (51%). Time to PVI was determined in 102/132 (77%) and in 112/140 (80%) veins during second-generation cryoballoon/third-generation cryoballoon (CB2G/CB3G) and CB4G ablation, respectively (P = 0.66). There was a statistically significant difference in terms of discrepancy rate between the SMC and the mini-basket catheter in PV detection after CB4G and CB2G/CB3G ablation(1.4% vs. 7.6%; P = 0.01). A total of 57 patients (84%) remained free of symptomatic AF during a mean follow-up of 9.8 ± 4.6 months. CONCLUSION: High-density mapping after cryoballoon ablation using CB4G and the new SMC identifies incomplete PVI, not detected by the new SMC, in a significantly lower proportion of veins compared to HDM performed after the other generation CB ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Catéteres , Criocirugía/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Recurrencia , Estudios Retrospectivos , Resultado del Tratamiento
18.
Europace ; 22(5): 777-786, 2020 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-31942982

RESUMEN

AIMS: The aim of this study was to determine the relationship between electrical and mechanical activation in heart failure (HF) patients and whether electromechanical coupling is affected by scar. METHODS AND RESULTS: Seventy HF patients referred for cardiac resynchronization therapy or biological therapy underwent endocardial anatomo-electromechanical mapping (AEMM) and delayed-enhancement magnetic resonance (CMR) scans. Area strain and activation times were derived from AEMM data, allowing to correlate mechanical and electrical activation in time and space with unprecedented accuracy. Special attention was paid to the effect of presence of CMR-evidenced scar. Patients were divided into a scar (n = 43) and a non-scar group (n-27). Correlation between time of electrical and mechanical activation was stronger in the non-scar compared to the scar group [R = 0.84 (0.72-0.89) vs. 0.74 (0.52-0.88), respectively; P = 0.01]. The overlap between latest electrical and mechanical activation areas was larger in the absence than in presence of scar [72% (54-81) vs. 56% (36-73), respectively; P = 0.02], with smaller distance between the centroids of the two regions [10.7 (4.9-17.4) vs. 20.3 (6.9-29.4) % of left ventricular radius, P = 0.02]. CONCLUSION: Scar decreases the association between electrical and mechanical activation, even when scar is remote from late activated regions.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Cicatriz/diagnóstico por imagen , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Imagen por Resonancia Cinemagnética
19.
Eur Heart J Case Rep ; 3(3): ytz109, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31660485

RESUMEN

BACKGROUND: Pulmonary vein isolation (PVI) is becoming the therapy of choice for symptomatic paroxysmal drug-refractory atrial fibrillation (AF). The most frequently reported complications are vascular complications (1.4%). Bleeding complications of the central nervous system have rarely been described. We report a case of spontaneous spinal bleed after PVI. CASE SUMMARY: A 68-year-old woman with a 2-year history of highly symptomatic paroxysmal AF (EHRA 3) was referred for a PVI redo procedure. A high-density mapping showed pulmonary vein reconnection of all pulmonary veins successfully isolated by radiofrequency ablation. During the entire procedure, the patient had sinus rhythm with an ACT around 300 s. No intraprocedural and peri-procedural complications occurred. Four hours after haemostasis, the anticoagulation clotting time (ACT) was 110 s and rivaroxaban (20 mg) was reinitiated. In the following hours, the patient developed fluctuating neurological lower limb symptoms. A lumbar magnetic resonance imaging showed a subdural spinal haematic collection with an associated epidural component from L3 to S2 exerting compression over the dural sheath. A conservative treatment approach was adopted with progressive recovery of sensorial and motor deficits. After 5 months, the patient still presented residual lower limb motor deficits necessitating the support of a walking stick. DISCUSSION: We describe the first case of a spontaneous spinal bleeding following PVI. Given the gradual diffusion of PVI to treat AF in more clinically complex patients with a larger range of comorbidities, particular consideration should be given to seek predisposing bleeding factors in order to assess the risk for neurological complications.

20.
Europace ; 21(11): 1670-1677, 2019 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-31504477

RESUMEN

AIMS: To define the clinical characteristics and long-term clinical outcomes of a large cohort of patients with idiopathic ventricular fibrillation (IVF) and normal 12-lead electrocardiograms (ECGs). METHODS AND RESULTS: Patients with ventricular fibrillation as the presenting rhythm, normal baseline, and follow-up ECGs with no signs of cardiac channelopathy including early repolarization or atrioventricular conduction abnormalities, and without structural heart disease were included in a registry. A total of 245 patients (median age: 38 years; males 59%) were recruited from 25 centres. An implantable cardioverter-defibrillator (ICD) was implanted in 226 patients (92%), while 18 patients (8%) were treated with drug therapy only. Over a median follow-up of 63 months (interquartile range: 25-110 months), 12 patients died (5%); in four of them (1.6%) the lethal event was of cardiac origin. Patients treated with antiarrhythmic drugs only had a higher rate of cardiovascular death compared to patients who received an ICD (16% vs. 0.4%, P = 0.001). Fifty-two patients (21%) experienced an arrhythmic recurrence. Age ≤16 years at the time of the first ventricular arrhythmia was the only predictor of arrhythmic recurrence on multivariable analysis [hazard ratio (HR) 0.41, 95% confidence interval (CI) 0.18-0.92; P = 0.03]. CONCLUSION: Patients with IVF and persistently normal ECGs frequently have arrhythmic recurrences, but a good prognosis when treated with an ICD. Children are a category of IVF patients at higher risk of arrhythmic recurrences.


Asunto(s)
Desfibriladores Implantables , Electrocardiografía , Paro Cardíaco Extrahospitalario/etiología , Sistema de Registros , Fibrilación Ventricular/complicaciones , Adolescente , Adulto , Niño , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Paro Cardíaco Extrahospitalario/diagnóstico , Paro Cardíaco Extrahospitalario/terapia , Valores de Referencia , Estudios Retrospectivos , Factores de Tiempo , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/fisiopatología , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA