Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros




Base de datos
Asunto de la revista
Intervalo de año de publicación
1.
Regul Toxicol Pharmacol ; 123: 104932, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33872739

RESUMEN

Cobalt (Co) is an essential element with human exposure occurring from the diet, supplement ingestion, occupational sources, and medical devices. The European Chemical Agency (ECHA) recently voted to classify Co metal as a Reproductive Hazard Category 1B; presumed human reproductive toxicant due to adverse testicular effects in male rodents. A weight of evidence evaluation of the preclinical reproductive and developmental toxicity studies and available clinical data was performed to critically evaluate the relevance of this proposed classification for Co in medical devices. Reproductive responses to Co are limited to the male testes and sperm function following high systemic exposure in rodents, only at Co concentrations/doses that result in overt toxicity (i.e., above the maximum tolerable dose (MTD)). The potential mechanisms of Co reproductive/developmental toxicity, including its indirect mode of action in the testes and relevance to humans, are discussed. The available preclinical and clincial evidence suggests that it would be more appropriate to classify Co as a Reproductive Hazard Category 2 compound: suspected human reproductive toxicant and, in the case of Co-containing medical devices, it should not be considered a reproductive hazard.


Asunto(s)
Cobalto/toxicidad , Sustancias Peligrosas/toxicidad , Reproducción/efectos de los fármacos , Animales , Dieta , Exposición a Riesgos Ambientales , Masculino , Ratones , Ratas , Medición de Riesgo , Espermatozoides
2.
Regul Toxicol Pharmacol ; 122: 104910, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33662479

RESUMEN

Cobalt (Co) alloys have been used for over seven decades in a wide range of medical devices, including, but not limited to, hip and knee implants, surgical tools, and vascular stents, due to their favorable biocompatibility, durability, and mechanical properties. A recent regulatory hazard classification review by the European Chemicals Agency (ECHA) resulted in the classification of metallic Co as a Class 1B Carcinogen (presumed to have carcinogenic potential for humans), primarily based on inhalation rodent carcinogenicity studies with pure metallic Co. The ECHA review did not specifically consider the carcinogenicity hazard potential of forms or routes of Co that are relevant for medical devices. The purpose of this review is to present a comprehensive assessment of the available in vivo preclinical data on the carcinogenic hazard potential of exposure to Co-containing alloys (CoCA) in medical devices by relevant routes. In vivo data were reviewed from 33 preclinical studies that examined the impact of Co exposure on local and systemic tumor incidence in rats, mice, guinea pigs, and hamsters. Across these studies, there was no significant increase of local or systemic tumors in studies relevant for medical devices. Taken together, the relevant in vivo data led to the conclusion that CoCA in medical devices are not a carcinogenic hazard in available in vivo models. While specific patient and implant factors cannot be fully replicated using in vivo models, the available in vivo preclinical data support that CoCA in medical devices are unlikely a carcinogenic hazard to patients.


Asunto(s)
Aleaciones/análisis , Cobalto/análisis , Equipos y Suministros , Aleaciones/administración & dosificación , Animales , Carcinogénesis , Cobalto/administración & dosificación , Humanos
3.
Toxicol Sci ; 70(1): 86-97, 2002 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-12388838

RESUMEN

Female mice, rats, and hamsters were exposed to 10, 50, or 250 mg/m(3) pigmentary titanium dioxide (p-TiO(2)) particles for 6 h per day and 5 days per week for 13 weeks with recovery groups held for an additional 4, 13, 26, or 52 weeks postexposure (46 weeks for the p-TiO(2)-exposed hamsters). At each time point p-TiO(2) burdens in the lung and lymph nodes and selected lung responses were examined. The responses studied were chosen to assess a variety of pulmonary parameters, including inflammation, cytotoxicity, lung cell proliferation, and histopathologic alterations. Burdens of p-TiO(2) in the lungs and in the lung-associated lymph nodes increased in a concentration-dependent manner. Retained lung burdens following exposure were greatest in mice. Rats and hamsters had similar lung burdens immediately postexposure when assessed as milligrams of p-TiO(2) per gram of dried lung. Particle retention data suggested that pulmonary overload was achieved in both rats and mice at the exposure levels of 50 and 250 mg/m(3). Under the conditions of the present study, hamsters were better able to clear p-TiO(2) particles than were similarly exposed mice and rats. Pulmonary histopathology revealed both species and concentration-dependent differences in p-TiO(2) particle retention patterns. Inflammation was noted in all three species at 50 and 250 mg/m(3), as evidenced by increases in macrophage and neutrophil numbers and in soluble indices of inflammation in bronchoalveolar lavage fluid (BALF; rats > mice, hamsters). In mice and rats, the BALF inflammatory responses remained elevated relative to controls throughout the entire postexposure recovery period in the most highly exposed animals. In comparison, inflammation in hamsters eventually disappeared, even at the highest exposure dose, due to the more rapid clearance of particles from the lung. Pulmonary lesions were most severe in rats, where progressive epithelial- and fibroproliferative changes were observed in the 250 mg/m(3) group. These epithelial proliferative changes were also manifested in rats as an increase in alveolar epithelial cell labeling in cell proliferation studies. Associated with these foci of epithelial proliferation were interstitial particle accumulation and alveolar septal fibrosis. In summary, there were significant species differences in pulmonary responses to inhaled p-TiO(2) particles. Under conditions in which the lung p-TiO(2) burdens were similar and likely to induce pulmonary overload, rats developed a more severe and persistent pulmonary inflammatory response than either mice or hamsters. Rats also were unique in the development of progressive fibroproliferative lesions and alveolar epithelial metaplasia in response to 90 days of exposure to a high concentration of p-TiO(2) particles.


Asunto(s)
Pulmón/efectos de los fármacos , Titanio/toxicidad , Administración por Inhalación , Animales , Carga Corporal (Radioterapia) , Líquido del Lavado Bronquioalveolar/citología , División Celular/efectos de los fármacos , Cricetinae , Femenino , Pulmón/patología , Ganglios Linfáticos/patología , Ratones , Ratones Endogámicos , Tamaño de la Partícula , Pigmentos Biológicos/farmacocinética , Pigmentos Biológicos/toxicidad , Ratas , Ratas Endogámicas , Especificidad de la Especie , Factores de Tiempo , Titanio/farmacocinética , Pruebas de Toxicidad Crónica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA