Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 247
Filtrar
1.
J Adv Nurs ; 2024 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-39253763

RESUMEN

AIM: To explore the barriers and facilitators influencing emergency department clinicians' adherence to the Australian Peripheral Intravenous Catheter (PIVC) Clinical Care Standard, using the Behaviour Change Wheel (BCW). BACKGROUND: Suboptimal PIVC practices are frequently linked to a range of patient-important adverse outcomes. The first Australian Peripheral Intravenous Catheter Clinical Care Standard was introduced in 2021, aiming to standardize practice. However, a recent national survey revealed a lack of adherence to the Standard among emergency department clinicians. DESIGN: A qualitative descriptive study. METHOD: The study was conducted across two Australian emergency departments in 2023. Utilizing purposive sampling, semi-structured interviews were conducted. The analysis incorporated both deductive and inductive approaches, mapping the findings to the BCW. FINDINGS: Interviews with 25 nurses and doctors revealed nine key subthemes. The main barriers were the stressful environment, insufficient education and training, and the absence of a feedback mechanism. The main facilitators were recognition of suboptimal practice, belief in the importance of patient engagement, and the desire to improve practice. CONCLUSION: Multiple complex factors have an impact on clinicians' adherence to the Standard. The identified interventions will serve as a guide for future implementation of the Standard. IMPLICATIONS FOR THE PROFESSION AND PATIENT CARE: The findings inform healthcare organizations of the significance of implementing strategies to enhance clinicians' acceptance of the Standard. Clinicians should consider incorporating the multifaceted interventions developed in accordance with the BCW for future implementation projects. IMPACT: Promoting adherence to standards opens avenues to challenge suboptimal practice and has the potential to instigate a culture shift in the fundamental skills of frontline clinicians. REPORTING METHOD: The study is designed and reported according to the Consolidated Criteria for Reporting Qualitative Research checklist. PATIENT OR PUBLIC CONTRIBUTION: No patient or public contribution.

2.
J Adv Nurs ; 2024 Sep 11.
Artículo en Inglés | MEDLINE | ID: mdl-39258848

RESUMEN

BACKGROUND: An evidence and consensus-based instrument is needed to classify central venous access device-associated skin impairments. AIM: The aim of this study was to design and evaluate the central venous access device-associated skin impairment classification tool. DESIGN: A two-phase modified Delphi study. METHODS: This two-phase study consisted of a literature review, followed by the development and validation of a classification instrument, by experts in the fields of central venous access devices and wound management (Phase 1). The instrument was tested (Phase 2) using 38 clinical photographs of a range of relevant skin impairments by the same expert panel. The expert panel consisted of registered nurses who were clinical researchers (n = 4) and clinical experts (n = 3) with an average of 24 years of nursing and research experience and 11 years of experience in wound management. Measures to assess preliminary content validity and inter-rater reliability were used. RESULTS: The instrument consists of five overarching aetiological classifications, including contact dermatitis, mechanical injury, infection, pressure injury and complex clinical presentation, with 14 associated subcategory diagnoses (e.g., allergic dermatitis, skin tear and local infection), with definitions and signs and symptoms. High agreement was achieved for preliminary scale content validity and item content validity (I-CVI = 1). Inter-rater reliability of aetiologies was high. The overall inter-rater reliability of individual definitions and signs and symptoms had excellent agreement. CONCLUSION: The development and preliminary validation of this classification tool provide a common language to guide the classification and assessment of central venous access device-associated skin impairment. IMPACT: The comprehensive and validated classification tool will promote accurate identification of central venous access device-associated skin impairment by establishing a common language for healthcare providers. The availability of this tool can reduce clinical uncertainty, instances of misdiagnosis and the potential for mismanagement. Consequently, it will play a pivotal role in guiding clinical decision-making, ultimately enhancing the quality of treatment and improving patient outcomes. REPORTING METHOD: The Guidance on Conducting and Reporting Delphi Studies (CREDES) was adhered to. PATIENT OR PUBLIC CONTRIBUTION: No patient or public contribution.

4.
Infect Dis Health ; 2024 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-39179494

RESUMEN

BACKGROUND: Access to arterial circulation through arterial catheters (ACs) is crucial for monitoring and decision-making in intensive care units (ICU) but carries the risk of complications including bloodstream infection (BSI). METHODS: We conducted a secondary analysis of data from four randomised controlled trials in Australian ICUs, investigating the efficacy of different AC interventions. De-identified data were combined into a single dataset, and per-patient outcomes analysed. The primary outcome was AC-BSI, defined as laboratory confirmed bloodstream infection (LCBI) type 1 or 2, with a concurrent local infection. All-cause AC failure was defined as any unplanned removal. AC infection and failure were reported as rates per 1000 catheter days and hours. RESULTS: Data from 1117 adult patients were analysed. Mean age was 58.8 years (±16.6); and 41% (n = 462) were male. Median AC dwell time was 110 h (IQR 28.3-168.0). There was one case (<0.1%; 0.18/1000 catheter days [95% CI 0.03-1.29]) of AC-BSI, and 14 cases of LCBI (1%; 13 LCBI-1 and 1 LCBI-2; 2.54/1000 catheter days [95% CI 1.51-4.30]). LCBI were most commonly Enterococcus faecalis; Escherichia coli and Klebsiella pneumoniae. There were four cases of local infection (<1%; 0.73/1000 catheter days [95% CI 0.27-1.94]). Overall AC failure rate was 13% (n = 146) or 26.53/1000 catheter days (95% CI 22.56-31.20). CONCLUSION: This study identified a relatively low incidence of complications. This is likely reflective of poor monitoring of ACs in intensive care. Better surveillance and a rigorous prospective evaluation of AC outcomes is required to understand the true risk ACs pose to critically ill patients.

5.
Aust Health Rev ; 2024 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-39183067

RESUMEN

Peripheral intravenous catheters (PIVCs) are required by most hospitalised patients. Difficult intravenous access (DIVA) makes insertion challenging, with poor patient outcomes, treatment delays and resource waste from multiple insertion attempts, often by multiple clinicians. This exploratory qualitative case study aimed to investigate how clinical and executive hospital staff view PIVC insertions for patients with DIVA from a cost and efficiency perspective. Fifteen semi-structured interviews were conducted with staff from three large, urban Australian hospitals. Data was thematically analysed, with four themes generated: (1) PIVCs are not considered from a cost or resource use perspective; (2) resources required for successful PIVC insertion are variable and unpredictable; (3) limited funding and support exist for advanced skill and ultrasound-guided insertion; and (4) processes for PIVC training and competency are inefficient. Investment in advanced PIVC inserters (with ultrasound-guided cannulation skills, and ability to train and assess novice inserters), with clear escalation pathways to these clinicians may reduce inefficiencies and waste associated with difficult PIVC insertions.

6.
J Crit Care Med (Targu Mures) ; 10(3): 232-244, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39108413

RESUMEN

Introduction: Early and accurate identification of high-risk patients with peripheral intravascular catheter (PIVC)-related phlebitis is vital to prevent medical device-related complications. Aim of the study: This study aimed to develop and validate a machine learning-based model for predicting the incidence of PIVC-related phlebitis in critically ill patients. Materials and methods: Four machine learning models were created using data from patients ≥ 18 years with a newly inserted PIVC during intensive care unit admission. Models were developed and validated using a 7:3 split. Random survival forest (RSF) was used to create predictive models for time-to-event outcomes. Logistic regression with least absolute reduction and selection operator (LASSO), random forest (RF), and gradient boosting decision tree were used to develop predictive models that treat outcome as a binary variable. Cox proportional hazards (COX) and logistic regression (LR) were used as comparators for time-to-event and binary outcomes, respectively. Results: The final cohort had 3429 PIVCs, which were divided into the development cohort (2400 PIVCs) and validation cohort (1029 PIVCs). The c-statistic (95% confidence interval) of the models in the validation cohort for discrimination were as follows: RSF, 0.689 (0.627-0.750); LASSO, 0.664 (0.610-0.717); RF, 0.699 (0.645-0.753); gradient boosting tree, 0.699 (0.647-0.750); COX, 0.516 (0.454-0.578); and LR, 0.633 (0.575-0.691). No significant difference was observed among the c-statistic of the four models for binary outcome. However, RSF had a higher c-statistic than COX. The important predictive factors in RSF included inserted site, catheter material, age, and nicardipine, whereas those in RF included catheter dwell duration, nicardipine, and age. Conclusions: The RSF model for the survival time analysis of phlebitis occurrence showed relatively high prediction performance compared with the COX model. No significant differences in prediction performance were observed among the models with phlebitis occurrence as the binary outcome.

7.
JAMA Pediatr ; 178(9): 861-869, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-39008311

RESUMEN

Importance: Catheter dislodgement is a common complication for children with tunneled or peripherally inserted noncuffed central venous catheters (CVCs). A subcutaneous anchor securement system (SASS) may reduce this risk compared with traditional adhesive securement. Objective: To compare dislodgement of noncuffed CVCs secured with SASS with dislodgement of noncuffed CVCs secured with sutureless securement devices (SSDs). Design, Setting, and Participants: The SECURED (Securing Central Venous Catheters to Prevent Dislodegment) trial was a pragmatic, multicenter, superiority randomized clinical trial with an internal pilot and was conducted from August 5, 2020, to August 30, 2022, at 2 Australian quaternary pediatric hospitals. Data analysis was performed in January 2023. Patients aged 0 to 18 years requiring a noncuffed CVC (≥3F catheter) were eligible for inclusion. Follow-up duration was 8 weeks or until device removal. Interventions: Patients were randomly assigned 1:1 to receive an SASS or SSD, stratified by hospital and catheter type. Only 1 catheter was studied per patient. Main Outcomes and Measures: The primary outcome was dislodgement (partial or total), defined as movement of the catheter tip by greater than 1 cm (change in external catheter length) at any point during catheter dwell. Dislodgement, reported as a risk ratio (RR), was estimated using a generalized linear model with binomial family and log link. Secondary outcomes were reported as incidence rate ratios and were analyzed using Poission regression. Outcomes reported as mean differences (MDs) were analyzed using linear regression. Results: Of 310 randomized patients, 175 patients (56.5%) were male and median (IQR) patient age was 48 (16-120) months. A total of 307 patients had a catheter device inserted, of which 153 (49.8%) were SASS and 154 (50.2%) were SSD, and were included in the intention-to-treat (ITT) analysis. Device dislodgement was lower with SASS (8 dislodgements in 153 patients [5.2%]) compared with SSD (35 dislodgements in 154 patients [22.7%]) (RR, 0.23; 95% CI, 0.11-0.48; P < .001). The per-protocol analysis was consistent with the ITT analysis. Partial dislodgement accounted for most dislodgement events, including 6 partial dislodgements in the SASS group (3.9%) and 30 partial dislodgements in the SSD group (19.5%) (RR, 0.18; 95% CI, 0.08-0.42). This contributed to fewer complications during dwell in the SASS group (37 reported complications [24.2%]) vs the SSD group (60 reported complications [39.0%]) (RR, 0.62; 95% CI, 0.44-0.87). Staff reported greater difficulty removing devices anchored with SASS vs SSD (mean [SD], 29.1 [31.3] vs 5.3 [17.0], respectively; MD, 23.8; 95% CI, 16.7-31.0). However, use of SASS resulted in reduced per-participant health care costs of A$36.60 (95% credible interval, 4.25-68.95; US $24.36; 95% credible interval, 2.83-45.89). Conclusions and Relevance: In the SECURED trial, noncuffed CVCs secured with SASS had fewer dislodgements compared with SSDs, with a lower cost per patient and an acceptable safety profile. Future efforts should be directed at SASS implementation at the health service level. Trial Registration: anzctr.org.au Identifier: ACTRN12620000783921.


Asunto(s)
Cateterismo Venoso Central , Catéteres Venosos Centrales , Humanos , Femenino , Masculino , Niño , Lactante , Preescolar , Adolescente , Catéteres Venosos Centrales/efectos adversos , Cateterismo Venoso Central/efectos adversos , Cateterismo Venoso Central/métodos , Recién Nacido , Falla de Equipo/estadística & datos numéricos
8.
BMJ Open ; 14(7): e084313, 2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-39013653

RESUMEN

INTRODUCTION: Peripheral intravenous catheters (PIVCs) are the most commonly used vascular access device in hospitalised patients. Yet PIVCs may be complicated by local or systemic infections leading to increased healthcare costs. Chlorhexidine gluconate (CHG)-impregnated dressings may help reduce PIVC-related infectious complications but have not yet been evaluated. We hypothesise an impregnated CHG transparent dressing, in comparison to standard polyurethane dressing, will be safe, effective and cost-effective in protecting against PIVC-related infectious complications and phlebitis. METHODS AND ANALYSIS: The ProP trial is a multicentre, superiority, randomised clinical and cost-effectiveness trial with internal pilot, conducted across three centres in Australia and France. Patients (adults and children aged ≥6 years) requiring one PIVC for ≥48 hours are eligible. We will exclude patients with emergent PIVCs, known CHG allergy, skin injury at site of insertion or previous trial enrolment. Patients will be randomised to 3M Tegaderm Antimicrobial IV Advanced Securement dressing or standard care group. For the internal pilot, 300 patients will be enrolled to test protocol feasibility (eligibility, recruitment, retention, protocol fidelity, missing data and satisfaction of participants and staff), primary endpoint for internal pilot, assessed by independent data safety monitoring committee. Clinical outcomes will not be reviewed. Following feasibility assessment, the remaining 2624 (1312 per trial arm) patients will be enrolled following the same methods. The primary endpoint is a composite of catheter-related infectious complications and phlebitis. Recruitment began on 3 May 2023. ETHICS AND DISSEMINATION: The protocol was approved by Ouest I ethic committee in France and by The Queensland Children's Hospital Human Research Ethics Committee in Australia. The findings will be disseminated through presentation at scientific conferences and publication in peer-reviewed journals. TRIAL REGISTRATION NUMBER: NCT05741866.


Asunto(s)
Vendajes , Infecciones Relacionadas con Catéteres , Cateterismo Periférico , Clorhexidina , Adulto , Niño , Humanos , Antiinfecciosos Locales/administración & dosificación , Australia , Infecciones Relacionadas con Catéteres/prevención & control , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/métodos , Clorhexidina/análogos & derivados , Clorhexidina/administración & dosificación , Clorhexidina/uso terapéutico , Análisis Costo-Beneficio , Francia , Flebitis/prevención & control , Flebitis/etiología , Ensayos Clínicos Controlados Aleatorios como Asunto
9.
Crit Care Resusc ; 26(2): 71-79, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-39072236

RESUMEN

Introduction: Monitoring healthcare quality is challenging in paediatric critical care due to measure variability, data collection burden, and uncertainty regarding consumer and clinician priorities. Objective: We sought to establish a core quality measure set that (i) is meaningful to consumers and clinicians and (ii) promotes alignment of measure use and collection across paediatric critical care. Design: We conducted a multi-stakeholder Delphi study with embedded consumer prioritisation survey. The Delphi involved two surveys, followed by a consensus meeting. Triangulation methods were used to integrate survey findings prior tobefore the consensus meeting. In the consensus panel, broad agreement was reached on a core measure set, and recommendations were made for future measurement directions in paediatric critical care. Setting and participants: Australian and New Zealand paediatric critical care survivors (aged >18 years) and families were invited to rank measure priorities in an online survey distributed via social media and consumer groups. A concurrent Delphi study was undertaken with paediatric critical care clinicians, policy makers, and a consumer representative. Interventions: None. Main outcome measures: Priorities for quality measures. Results: Respondents to the consumer survey (n = 117) identified (i) nurse-patient ratios; (ii) visible patient goals; and (iii) long-term follow-up as their quality measure priorities. In the Delphi process, clinicians (Round 1 n = 191; Round 2 n = 117 [61% retention]; Round 3 n = 14) and a consumer representative reached broad agreement on a 51-item (61% of 83 initial measures) core measure set. Clinician priorities were (i) nurse-patient ratio; (ii) staff turnover; and (iii) long term-follow up. Measure feasibility was rated low due to a perceived lack of standardised case definitions or data collection burden. Five recommendations were generated. Conclusions: We defined a 51-item core measurement set for paediatric critical care, aligned with clinician and consumer priorities. Next steps are implementation and methodological evaluation in quality programs, and where appropriate, retirement of redundant measures.

10.
Cochrane Database Syst Rev ; 5: CD013023, 2024 05 23.
Artículo en Inglés | MEDLINE | ID: mdl-38780138

RESUMEN

BACKGROUND: Peripheral arterial catheters (ACs) are used in anaesthesia and intensive care settings for blood sampling and monitoring. Despite their importance, ACs often fail, requiring reinsertion. Dressings and securement devices maintain AC function and prevent complications such as infection. OBJECTIVES: To evaluate the effectiveness of peripheral AC dressing and securement devices to prevent failure and complications in hospitalised people. SEARCH METHODS: We searched the Cochrane Wounds Specialised Register, CENTRAL, MEDLINE, Embase, and CINAHL Plus up to 16 May 2023. We also searched ClinicalTrials.gov and the World Health Organization International Clinical Trials Registry Platform up to 16 May 2023. SELECTION CRITERIA: We included randomised controlled trials (RCTs) comparing different dressing and securement devices for the stabilisation of ACs in hospitalised people. DATA COLLECTION AND ANALYSIS: Two review authors independently selected trials for inclusion, extracted data, and assessed risk of bias using Cochrane's RoB 1 tool. We resolved disagreements by discussion, or by consulting a third review author when necessary. We assessed the certainty of evidence using GRADE. MAIN RESULTS: We included five RCTs with 1228 participants and 1228 ACs. All included studies had high risk of bias in one or more domains. We present the following four comparisons, with the remaining comparisons reported in the main review. Standard polyurethane (SPU) plus tissue adhesive (TA) compared with SPU: we are very uncertain whether use of SPU plus TA impacts rates of AC failure (risk ratio (RR) 0.44, 95% confidence interval (CI) 0.20 to 0.98; I² = 0%; 2 studies, 165 participants; very low-certainty evidence). Neither study (165 participants) reported catheter-related bloodstream infections (CRBSI), thus we are very uncertain whether SPU plus TA impacts on the incidence of CRBSI (very low-certainty evidence). It is very uncertain whether use of SPU plus TA impacts AC dislodgement risk (RR 0.54, 95% CI 0.03 to 9.62; I² = 44%; 2 studies, 165 participants; very low-certainty evidence). We are very uncertain whether use of SPU plus TA impacts AC occlusion rates (RR 1.20, 95% CI 0.37 to 3.91; I² = 3%; 2 studies, 165 participants; very low-certainty evidence). We are very uncertain whether use of SPU plus TA impacts rates of adverse events with few reported events across groups (RR 0.89, 95% CI 0.09 to 8.33; I² = 0%; 2 studies, 165 participants; very low-certainty evidence). Bordered polyurethane (BPU) compared to SPU: we are very uncertain whether use of BPU impacts rates of AC failure (RR 0.67, 95% CI 0.21 to 2.13; 1 study, 60 participants; very low-certainty evidence). BPU may make little or no difference to CRBSI compared to SPU (RR 3.05, 95% CI 0.12 to 74.45; I² = not applicable as 1 study (60 participants) reported 0 events; 2 studies, 572 participants; low-certainty evidence). BPU may make little or no difference to the risk of AC dislodgement compared with SPU (RR 0.75, 95% CI 0.17 to 3.22; I² = 0%; 2 studies, 572 participants; low-certainty evidence). BPU may make little or no difference to occlusion risk compared with SPU (RR 0.80, 95% CI 0.60 to 1.07; I² = 0%; 2 studies, 572 participants; low-certainty evidence). It is very uncertain whether BPU impacts on the risk of adverse events compared with SPU (RR 0.33, 95% CI 0.01 to 7.87; 1 study, 60 participants; very low-certainty evidence). SPU plus sutureless securement devices (SSD) compared to SPU: we are very uncertain whether SPU plus SSD impacts risk of AC failure compared with SPU (RR 0.78, 95% CI 0.40 to 1.52; I² = 0%; 2 studies, 157 participants; very low-certainty evidence). We are very uncertain if SPU plus SSD impacts CRBSI incidence rate with no events in both groups (2 studies, 157 participants; very low-certainty evidence). It is very uncertain whether SPU plus SSD impacts risk of dislodgement (RR 0.14, 95% CI 0.01 to 2.57; I² = not applicable as 1 study (96 participants) reported 0 events; 2 studies, 157 participants; very low-certainty evidence). It is very uncertain whether SPU plus SSD impacts risk of AC occlusion (RR 1.94, 95% CI 0.50 to 7.48; I² = 38%; 2 studies, 157 participants; very low-certainty evidence). We are very uncertain whether SPU plus SSD impacts on the risk of adverse events (RR 1.94, 95% CI 0.19 to 20.24; I² = not applicable as 1 study (96 participants) reported 0 events; 2 studies, 157 participants; very low-certainty evidence). Integrated securement dressings compared to SPU: integrated securement dressings may result in little or no difference in risk of AC failure compared with SPU (RR 1.96, 95% CI 0.80 to 4.84; 1 study, 105 participants; low-certainty evidence); may result in little or no difference in CRBSI incidence with no events reported (1 study, 105 participants; low-certainty evidence); may result in little or no difference in the risk of dislodgement (RR 0.33, 95% CI 0.04 to 3.04; 1 study, 105 participants; low-certainty evidence), may result in little or no difference in occlusion rates with no events reported (1 study, 105 participants; low-certainty evidence), and may result in little or no difference in the risk of adverse events (RR 0.35, 95% CI 0.01 to 8.45; 1 study, 105 participants; low-certainty evidence). AUTHORS' CONCLUSIONS: There is currently limited rigorous RCT evidence available about the relative clinical effectiveness of AC dressing and securement products. Limitations of current evidence include small sample size, infrequent events, and heterogeneous outcome measurements. We found no clear difference in the incidence of AC failure, CRBSI, or adverse events across AC dressing or securement products including SPU, BPU, SSD, TA, and integrated securement products. The limitations of current evidence means further rigorous RCTs are needed to reduce uncertainty around the use of dressing and securement devices for ACs.


Asunto(s)
Vendajes , Infecciones Relacionadas con Catéteres , Cateterismo Periférico , Poliuretanos , Ensayos Clínicos Controlados Aleatorios como Asunto , Humanos , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/instrumentación , Infecciones Relacionadas con Catéteres/prevención & control , Sesgo , Falla de Equipo
11.
J Hosp Med ; 19(10): 905-917, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38800854

RESUMEN

BACKGROUND: Central venous access devices (CVADs) allow intravenous therapy, haemodynamic monitoring and blood sampling but many fail before therapy completion. OBJECTIVE: To quantify CVAD failure and complications; and identify risk factors. DESIGNS, SETTINGS, AND PARTICIPANTS: Secondary analysis of multicentre randomised controlled trial including patients aged ≥16 years with a non-tunnelled CVAD (NTCVAD), peripherally-inserted central catheter (PICC) or tunnelled CVAD (TCVAD). Primary outcome was incidence of all-cause CVAD failure (central line-associated bloodstream infection [CLABSI], occlusion, accidental dislodgement, catheter fracture, thrombosis, pain). Secondary outcomes were CLABSI, occlusion and dislodgement. Cox regression was used to report time-to-event associations. RESULTS: In 1892 CVADs, all-cause failure occurred in 10.2% of devices: 49 NTCVADs (6.1%); 100 PICCs (13.2%); 44 TCVADs (13.4%). Failure rates for CLABSI, occlusion and dislodgement were 5.3%, 1.8%, and 1.7%, respectively. Independent CLABSI predictors were blood product administration through PICCs (hazard ratio (HR) 2.62, 95% confidence interval (CI) 1.24-5.55); and in TCVADs, one or two lumens, compared with three to four (HR 3.36, 95%CI 1.68-6.71), intravenous chemotherapy (HR 2.96, 95%CI 1.31-6.68), and diabetes (HR 3.25, 95%CI 1.40-7.57). Independent factors protective for CLABSI include antimicrobial NTCVADs (HR 0.23, 95%CI 0.08-0.63) and lipids in TCVADs (HR 0.32, 95%CI 0.14-0.72). NTCVADs inserted at another hospital (HR 7.06, 95%CI 1.48-33.7) and baseline infection in patients with PICCs (HR 2.72, 95%CI 1.08-6.83) were predictors for dislodgement. No independent occlusion predictors were found. Modifiable risk factors were identified for CVAD failure, which occurred for 1-in-10 catheters. Strict infection prevention measures and improved CVAD securement could reduce CLABSI and dislodgement risk.


Asunto(s)
Infecciones Relacionadas con Catéteres , Cateterismo Venoso Central , Catéteres Venosos Centrales , Falla de Equipo , Humanos , Masculino , Femenino , Factores de Riesgo , Persona de Mediana Edad , Catéteres Venosos Centrales/efectos adversos , Incidencia , Falla de Equipo/estadística & datos numéricos , Cateterismo Venoso Central/efectos adversos , Infecciones Relacionadas con Catéteres/epidemiología , Anciano , Adulto , Hospitalización
12.
Semin Oncol Nurs ; 40(3): 151618, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38622044

RESUMEN

OBJECTIVES: To identify the prevalence and type of central venous access device-associated skin complications for adult cancer patients, describe central venous access device management practices, and identify clinical and demographic characteristics associated with risk of central venous access device-associated skin complications. METHODS: A prospective cohort study of 369 patients (626 central venous access devices; 7,682 catheter days) was undertaken between March 2017 and March 2018 across two cancer care in-patient units in a large teaching hospital. RESULTS: Twenty-seven percent (n = 168) of participants had a central venous access device-associated skin complication. In the final multivariable analysis, significant (P < .05) risk factors for skin complications were cutaneous graft versus host disease (2.1 times greater risk) and female sex (1.4 times greater risk), whereas totally implanted vascular access device reduced risk for skin complications by two-thirds (incidence risk ratio 0.37). CONCLUSION: Central venous access device-associated skin complications are a significant, potentially avoidable injury, requiring cancer nurses to be aware of high-risk groups and use evidence-based preventative and treatment strategies. IMPLICATIONS FOR PRACTICE: This study has confirmed how common these potentially preventable injuries are. Therefore, the prevalence of these complications could be reduced by focusing on improvements in skin assessment, reductions in central venous access device dressing variation and improving clinician knowledge of this injury.


Asunto(s)
Cateterismo Venoso Central , Neoplasias , Humanos , Femenino , Masculino , Estudios Prospectivos , Persona de Mediana Edad , Anciano , Adulto , Cateterismo Venoso Central/efectos adversos , Catéteres Venosos Centrales/efectos adversos , Enfermedades de la Piel/etiología , Enfermedades de la Piel/epidemiología , Factores de Riesgo , Anciano de 80 o más Años , Estudios de Cohortes
13.
J Vasc Access ; : 11297298241246300, 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38659089

RESUMEN

BACKGROUND: There is little information regarding complications of arterial catheterization in modern clinical care. We aimed to determine the incidence of abnormal duplex vascular ultrasound and catheter related infections following perioperative arterial catheterization. METHODS: Patients requiring arterial catheterization for elective surgery were included and insertion details collected prospectively. Duplex ultrasound evaluation was performed 24 h after catheter removal. Symptomatic patients were identified by self-reported questionnaire. On Day 7, patients answered questions by telephone, related to the insertion site, pain, and function. Results of catheter tip and blood culture analyses were sought. Univariate associations of patient and surgical characteristics with abnormal ultrasound were assessed with p < 0.05 considered significant. RESULTS: Of 339 catheterizations, 105 (40%) had ultrasound evaluation. Catheters were indwelling for median (IQR, range) duration of 6.0 h (4.4-8.2, 1.8-28) with no catheter-related infections. There were 16 (15.2%, 95% CI 9.0%-23.6%) abnormal results, including 14 radial artery thromboses, one radial artery dissection, and one radial vein thrombosis. Those with abnormal ultrasound results were more likely to have had Arrow catheters inserted (68.8% vs 27%, p = 0.023) and more than one skin puncture (37.5% vs 26.8%, p = 0.031). Two of the 16 (12.5%) patients with abnormal ultrasound results reported new symptoms related to the hand compared with nine of the 88 (10.2%) with normal results (p = 0.1). No patients required urgent referral for management. CONCLUSIONS: Thrombosis was the most common abnormality and was usually asymptomatic. There were no infections, few post-operative symptoms, and minimal functional impairment following arterial catheterization.

14.
J Intensive Care ; 12(1): 12, 2024 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-38459599

RESUMEN

OBJECTIVES: Arterial catheters (ACs) are critical for haemodynamic monitoring and blood sampling but are prone to complications. We investigated the incidence and risk factors of AC failure. METHODS: Secondary analysis of a multi-centre randomised controlled trial (ACTRN 12610000505000). Analysis included a subset of adult intensive care unit patients with an AC. The primary outcome was all-cause device failure. Secondary outcomes were catheter associated bloodstream infection (CABSI), suspected CABSI, occlusion, thrombosis, accidental removal, pain, and line fracture. Risk factors associated with AC failure were investigated using Cox proportional hazards and competing-risk models. RESULTS: Of 664 patients, 173 (26%) experienced AC failure (incidence rate [IR] 37/1000 catheter days). Suspected CABSI was the most common failure type (11%; IR 15.3/1000 catheter days), followed by occlusion (8%; IR 11.9/1,000 catheter days), and accidental removal (4%; IR 5.5/1000 catheter days). CABSI occurred in 16 (2%) patients. All-cause failure and occlusion were reduced with ultrasound-assisted insertion (failure: adjusted hazard ratio [HR] 0.43, 95% CI 0.25, 0.76; occlusion: sub-HR 0.11, 95% CI 0.03, 0.43). Increased age was associated with less AC failure (60-74 years HR 0.63, 95% CI 0.44 to 0.89; 75 + years HR 0.36, 95% CI 0.20, 0.64; referent 15-59 years). Females experienced more occlusion (adjusted sub-HR 2.53, 95% CI 1.49, 4.29), while patients with diabetes had less (SHR 0.15, 95% CI 0.04, 0.63). Suspected CABSI was associated with an abnormal insertion site appearance (SHR 2.71, 95% CI 1.48, 4.99). CONCLUSIONS: AC failure is common with ultrasound-guided insertion associated with lower failure rates. Trial registration Australian New Zealand Clinical Trial Registry (ACTRN 12610000505000); date registered: 18 June 2010.

15.
J Pediatr Nurs ; 76: 68-75, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38364591

RESUMEN

PURPOSE: Children with chronic and complex health conditions frequently need intravenous devices. The current approach to intravenous device selection, insertion, and monitoring is inconsistent, and healthcare consumers are often negatively affected by siloed health information, and poor future planning. Despite child- and family-centred care being recognised as a pillar of paediatric nursing care, limited implementation for vascular access device planning and management is evident. DESIGN AND METHODS: To address this, we conducted a multi-phased approach to co-create, then evaluate, a mobile health (mHealth) application: IV Passport. Co-creation involved a prioritisation survey, followed by a Passport advisory panel consensus meeting. Following confirmation of the required content and features of the Passport, the mHealth application was designed and content validation achieved via survey. RESULTS: The prioritisation survey yielded recommendations for seven features (e.g., graphical presentations of current/past devices). Content for nine device types (e.g., totally implanted ports) was suggested, each with 10 related items (e.g., insertion site). Content items for device-associated complications, future vascular access plans, and educational resources were also suggested. Following design, the application was released through Apple and Android platforms; and adapted to a paper version. Content validation was established; 100% strongly agreed the application was easy to use; 80% agreed/strongly agreed that they would recommend the Passport to others. CONCLUSION: IV Passport embodies effective child- and family-centred care through consumer co-creation to empower patients and families manage vascular access devices. PRACTICE IMPLICATIONS: IV Passport remains active; and can be utilised across many healthcare settings and patient populations.


Asunto(s)
Telemedicina , Dispositivos de Acceso Vascular , Humanos , Niño , Aplicaciones Móviles , Masculino , Femenino , Enfermedad Crónica , Enfermería Pediátrica
16.
J Infus Nurs ; 47(2): 75-95, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38422403

RESUMEN

Ultrasound-guided insertion of peripheral intravenous catheters (PIVCs) is recommended for patients with difficult intravenous access, but access to ultrasound equipment is often limited to specialty departments. Compact, affordable handheld ultrasound devices are available, but the extent of their clinical adoption and impact on patient outcomes is unknown. This scoping review aimed to explore evidence regarding handheld and pocket ultrasound devices for PIVC insertion. Databases were searched for studies published in English between January 2000 and January 2023 evaluating handheld or pocket ultrasound devices weighing ≤3 kg for PIVC insertion. Data were extracted using standardized forms and summarized using descriptive statistics. Seventeen studies reporting the use of handheld or pocket ultrasound devices were identified. Most studies were conducted in adult inpatient facilities; 3 included pediatrics, and 2 reported out-of-hospital use. Participants with difficult intravenous access featured in 9 studies. Ultrasound training programs were described in 12 studies, with competency defined by number of successful PIVC insertions. Five studies reported clinician and/or patient perspectives. Ultrasound for PIVC insertion is not widely accessible in nonspecialist areas, but more compact and affordable handheld models could provide a solution, especially for patients with difficult access. More research evidence using handheld ultrasound is needed.


Asunto(s)
Cateterismo , Adulto , Humanos , Niño , Administración Intravenosa , Bases de Datos Factuales
17.
J Clin Nurs ; 33(5): 1762-1776, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38413831

RESUMEN

BACKGROUND: Healthcare consumers require diverse resources to assist their navigation of complex healthcare interactions, however, these resources need to be fit for purpose. AIM: In this study, we evaluated the utility, usability and feasibility of children, families and adults requiring long-term intravenous therapy using a recently developed mobile health application (App), intravenous (IV) Passport. DESIGN: Multi-site, parallel, multi-method, prospective cohort study. METHODS: A multi-site, multi-method study was carried out in 2020-2021, with 46 participants (20 adults, 26 children/family) reporting on their experiences surrounding the use of the IV Passport for up to 6 months. RESULTS: Overall, utility rates were acceptable, with 78.3% (N = 36) using the IV Passport over the follow-up period, with high rates of planned future use for those still active in the project (N = 21; 73%), especially in the child/family cohort (N = 13; 100%). Acceptability rates were high (9/10; IQR 6.5-10), with the IV Passport primarily used for documenting new devices and complications. Thematic analysis revealed three main themes (and multiple subthemes) in the qualitative data: Advocacy for healthcare needs, Complexity of healthcare and App design and functionality. CONCLUSION: Several recommendations were made to improve the end-user experience including 'how to' instructions; and scheduling functionality for routine care. IMPLICATIONS FOR THE PROFESSION AND/OR PATIENT CARE: The IV Passport can be safely and appropriately integrated into healthcare, to support consumers. IMPACT: Patient-/parent-reported feedback suggests the Intravenous Passport is a useful tool for record-keeping, and positive communication between patients/parents, and clinicians. REPORTING METHOD: Not applicable. PATIENT CONTRIBUTION: Consumers reported their experiences surrounding the use of the IV Passport for up to 6 months.


Asunto(s)
Telemedicina , Adulto , Niño , Humanos , Estudios Prospectivos , Telemedicina/métodos , Atención a la Salud , Padres , Comunicación
18.
Health Qual Life Outcomes ; 22(1): 1, 2024 Jan 02.
Artículo en Inglés | MEDLINE | ID: mdl-38167165

RESUMEN

BACKGROUND: Peripheral intravenous catheters (PIVCs) are essential for successful administration of intravenous treatments. However, insertion failure and PIVC complications are common and negatively impact patients' health-outcomes and experiences. We aimed to assess whether generic (not condition-specific) quality of life and experience measures were suitable for assessing outcomes and experiences of patients with PIVCs. METHODS: We undertook a secondary analysis of data collected on three existing instruments within a large randomised controlled trial, conducted at two adult tertiary hospitals in Queensland, Australia. Instruments included the EuroQol Five Dimension - Five Level (EQ5D-5L), the Functional Assessment of Chronic Illness Therapy - Treatment Satisfaction - General measure (FACIT-TS-G, eight items), and the Australian Hospital Patient Experience Question Set (AHPEQS, 12 items). Responses were compared against two clinical PIVC outcomes of interest: all-cause failure and multiple insertion attempts. Classic descriptives were reported for ceiling and floor effects. Regression analyses examined validity (discrimination). Standardised response mean and effect size (ES) assessed responsiveness (EQ5D-5L, only). RESULTS: In total, 685 participants completed the EQ5D-5L at insertion and 526 at removal. The FACIT-TS-G was completed by 264 and the AHPEQS by 262 participants. Two FACIT-TS-G items and one AHPEQS item demonstrated ceiling effect. Instruments overall demonstrated poor discrimination, however, all-cause PIVC failure was significantly associated with several individual items in the instruments (e.g., AHPEQS, 'unexpected physical and emotional harm'). EQ5D-5L demonstrated trivial (ES < 0.20) responsiveness. CONCLUSIONS: Initial investigation of an existing health-related quality of life measure (EQ5D-5L) and two patient-reported experience measures (FACIT-TS-G; AHPEQS) suggest they are inadequate (as a summary measure) to assess outcomes and experiences for patients with PIVCs. Reliable instruments are urgently needed to inform quality improvement and benchmark standards of care.


Asunto(s)
Calidad de Vida , Análisis de Datos Secundarios , Adulto , Humanos , Australia , Queensland , Catéteres
19.
Aust Crit Care ; 37(3): 495-498, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-37385895

RESUMEN

BACKGROUND: Infusion sets (comprising the tubing, measuring burettes, fluid containers, transducers) that are connected to invasive vascular devices are changed on a regular basis in an effort to reduce bacterial colonisation and bloodstream infection. There is a balance between reducing infection and creating unnecessary waste. Current evidence suggests that for central venous catheters (CVCs), changing infusion sets at 7 days does not increase infection risks. OBJECTIVES: The objective of this study was to describe the current unit guidelines in Australian and New Zealand intensive care units (ICUs) for changing infusion sets for CVCs. METHODS: prospective cross-sectional point prevalence study, as a part of the 2021 Australian and New Zealand Intensive Care Society Point Prevalence Program. PARTICIPANTS: Australia and New Zealand (ANZ) adult ICUs and their patients on the day of the study. RESULTS: Data were collected from 51 ICUs across ANZ. One-third of these (16/49) ICUs had a guideline that specified a 7-day replacement period, with the rest having a more frequent replacement period. CONCLUSION: Most ICUs participating in this survey had policies to change their CVC infusion tubing in 3-4 days, and recent high-level evidence supports an update to extend this to 7 days. There remains work to be done to spread this evidence to ANZ ICUs and improve environmental sustainability initiatives.


Asunto(s)
Catéteres Venosos Centrales , Adulto , Humanos , Estudios Transversales , Nueva Zelanda/epidemiología , Prevalencia , Estudios Prospectivos , Australia/epidemiología , Unidades de Cuidados Intensivos
20.
Int J Nurs Stud ; 151: 104673, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38142634

RESUMEN

BACKGROUND: Peripheral intravenous catheters are the most frequently used invasive device in nursing practice, yet are commonly associated with complications. We performed a systematic review to determine the prevalence of peripheral intravenous catheter infection and all-cause failure. METHODS: The Cochrane Library, PubMed, CINAHL, and EMBASE were searched for observational studies and randomised controlled trials that reported peripheral intravenous catheter related infections or failure. The review was limited to English language and articles published from the year 2000. Pooled estimates were calculated with random-effects models. Meta-analysis of observation studies in epidemiology guidelines and the Cochrane process for randomised controlled trials were used to guide the review. Prospero registration number: CRD42022349956. FINDINGS: Our search retrieved 34,725 studies. Of these, 41 observational studies and 28 randomised controlled trials (478,586 peripheral intravenous catheters) met inclusion criteria. The pooled proportion of catheter-associated bloodstream infections was 0.028 % (95 % confidence interval (CI): 0.009-0.081; 38 studies), or 4.40 catheter-associated bloodstream infections per 100,000 catheter-days (20 studies, 95 % CI: 3.47-5.58). Local infection was reported in 0.150 % of peripheral intravenous catheters (95 % CI: 0.047-0.479, 30 studies) with an incidence rate of 65.1 per 100,000 catheter-days (16 studies; 95 % CI: 49.2-86.2). All cause peripheral intravenous catheter failure before treatment completion occurred in 36.4 % of catheters (95 % CI: 31.7-41.3, 53 studies) with an overall incidence rate of 4.42 per 100 catheter days (78,891 catheter days; 19 studies; 95 % CI: 4.27-4.57). INTERPRETATION: Peripheral intravenous catheter failure is a significant worldwide problem, affecting one in three catheters. Per peripheral intravenous catheter, infection occurrence was low, however, with over two billion catheters used globally each year, the absolute number of infections and associated burden remains high. Substantial and systemwide efforts are needed to address peripheral intravenous catheter infection and failure and the sequelae of treatment disruption, increased health costs and poor patient outcomes.


Asunto(s)
Infecciones Relacionadas con Catéteres , Cateterismo Periférico , Humanos , Cateterismo Periférico/efectos adversos , Infecciones Relacionadas con Catéteres/epidemiología , Infecciones Relacionadas con Catéteres/prevención & control
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA