Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-39033774

RESUMEN

BACKGROUND: Computer-aided detection (CADe) systems for colonoscopy have been shown to increase small polyp detection during colonoscopy in the general population. People with Lynch syndrome represent an ideal target population for CADe-assisted colonoscopy because adenomas, the primary cancer precursor lesions, are characterised by their small size and higher likelihood of showing advanced histology. We aimed to evaluate the performance of CADe-assisted colonoscopy in detecting adenomas in individuals with Lynch syndrome. METHODS: TIMELY was an international, multicentre, parallel, randomised controlled trial done in 11 academic centres and six community centres in Belgium, Germany, Italy, and Spain. We enrolled individuals aged 18 years or older with pathogenic or likely pathogenic MLH1, MSH2, MSH6, or EPCAM variants. Participants were consecutively randomly assigned (1:1) to either CADe (GI Genius) assisted white light endoscopy (WLE) or WLE alone. A centre-stratified randomisation sequence was generated through a computer-generated system with a separate randomisation list for each centre according to block-permuted randomisation (block size 26 patients per centre). Allocation was automatically provided by the online AEG-REDCap database. Participants were masked to the random assignment but endoscopists were not. The primary outcome was the mean number of adenomas per colonoscopy, calculated by dividing the total number of adenomas detected by the total number of colonoscopies and assessed in the intention-to-treat population. This trial is registered with ClinicalTrials.gov, NCT04909671. FINDINGS: Between Sept 13, 2021, and April 6, 2023, 456 participants were screened for eligibility, 430 of whom were randomly assigned to receive CADe-assisted colonoscopy (n=214) or WLE (n=216). 256 (60%) participants were female and 174 (40%) were male. In the intention-to-treat analysis, the mean number of adenomas per colonoscopy was 0·64 (SD 1·57) in the CADe group and 0·64 (1·17) in the WLE group (adjusted rate ratio 1·03 [95% CI 0·72-1·47); p=0·87). No adverse events were reported during the trial. INTERPRETATION: In this multicentre international trial, CADe did not improve the detection of adenomas in individuals with Lynch syndrome. High-quality procedures and thorough inspection and exposure of the colonic mucosa remain the cornerstone in surveillance of Lynch syndrome. FUNDING: Spanish Gastroenterology Association, Spanish Society of Digestive Endoscopy, European Society of Gastrointestinal Endoscopy, Societat Catalana de Digestologia, Instituto Carlos III, Beca de la Marato de TV3 2020. Co-funded by the European Union.

2.
Endosc Int Open ; 12(3): E344-E351, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38481597

RESUMEN

Background and study aims In 2019, the European Society of Gastrointestinal Endoscopy (ESGE) created a working group to develop technical and quality standards for small-bowel capsule endoscopy (SBCE) to improve the daily practice of endoscopy services. They developed 10 quality parameters, which have yet to be tested in a real-life setting. Our study aimed to evaluate the accomplishment of the quality standards in SBCE established by the ESGE in several Spanish centers. Materials and methods An online survey of 11 multiple-choice questions related to the ESGE performance measures was sent to Spanish centers with experience in SBCE. In order to participate and obtain reliable data, at least 100 questionnaires had to be answered per center because that is the minimum number established by ESGE. Results 20 centers participated in the study, compiling 2049 SBCEs for the analysis. Only one of 10 performance measures (cecal visualization) reached the minimum standard established by the ESGE. In five of 10 performance measures (Indication, lesion detection rate, terminology, and retention rate) the minimum standard was nearly achieved. Conclusions Our study is the first multicenter study regarding SBCE quality performance measures in a real setting. Our results show that the minimum standard is hardly reached in most procedures, which calls into question their clinical applicability in real life. We suggest performing similar studies in other countries to evaluate whether there is a need for quality improvement programs or a need to reevaluate the minimum and target values published so far.

3.
Diagnostics (Basel) ; 12(9)2022 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-36140627

RESUMEN

(1) Background: Fecal calprotectin (FC) correlates well with colonic inflammatory activity of Crohn's disease (CD); data about relation of FC and small bowel (SB) lesions are still contradictory. The main aim was to analyze the relationship between FC levels and SB inflammatory activity in patients with established or suspected Crohn's disease, assessed by small bowel capsule endoscopy (SBCE) or magnetic resonance enterography (MRE). (2) Methods: Two cohorts of patients were included: 1. Prospective data were collected from patients with established or suspected CD who underwent SBCE and FC (Cohort A); 2. A retrospective cohort of patients who underwent MRE and FC determination (Cohort B). Different cutoffs for FC were tested in both cohorts. (3) Results: 83 patients were included and 66 were finally analyzed. A total of 69.6% had SB lesions seen by SBCE (n = 25) or MRE (n = 21). FC mean levels were 605.74 + 607.07 µg/g (IQ range: 99.00−878.75), being significantly higher in patients with SB lesions compared to patients without lesions (735.91 + 639.70 µg/g (IQ range: 107.75−1366.25) vs. 306.35 + 395.26 µg/g (IQ range: 78.25−411.0), p < 0.005). For cohort A, 25 out of 35 patients had SB lesions and a significant correlation between Lewis Score and FC levels was achieved (R2: 0.34; p = 0.04). FC sensitivity (S), specificity (E), positive predictive value (PPV), and negative predictive values (NPV) for predicting SB lesions were 80%, 50%, 80%, and 50%, respectively, for FC > 100 µg/g. For cohort B, inflammatory SB activity, measured by MaRIA score, was detected in 21 out of 31 patients (67.7%). Patients with positive findings in MRE had significantly higher values of FC than those with no lesions (944.9 + 672.1 µg/g vs. 221 + 212.2 µg/g, p < 0.05). S, E, PPV, and NPV of FC were 89%, 50%, 77.2%, and 71.4% for FC levels > 100 µg/g. The higher sensitivity and specificity of the FC levels for the detection of SB lesions with SBCE and MRE was obtained for an FC cutoff >265 µg/g and >430 µg/g, respectively. (4) Conclusions: FC has a good correlation with the presence of SB lesions, assessed by SBCE and MRE, in patients with established or suspected Crohn's disease. However, the ideal cutoff is here proven to be higher than previously reported. Multicenter and large prospective studies are needed in order to establish definitive FC cutoff levels.

5.
Dig Endosc ; 34(6): 1176-1184, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35189669

RESUMEN

OBJECTIVES: When bowel preparation (BP) is inadequate, international guidelines recommend repeating the colonoscopy within 1 year to avoid missing clinically relevant lesions. We aimed to determine the rate of missed lesions in patients with inadequate BP through a very early repeat colonoscopy with adequate BP. METHODS: Post hoc analysis was conducted using data collected from a prospective multicenter randomized clinical trial including patients with inadequate BP and then repeat colonoscopy. Inadequate BP was defined as the Boston Bowel Preparation Scale (BBPS) score <2 points in any segment. We included patients with any indication for colonoscopy. The adenoma detection rate (ADR), advanced ADR (AADR), and serrated polyp detection rate (SPDR) were calculated for index and repeat colonoscopies. RESULTS: Of the 651 patients with inadequate BP from the original trial, 413 (63.4%) achieved adequate BP on repeat colonoscopy. The median interval between index and repeat colonoscopies was 28 days. On repeat colonoscopy, the ADR was 45.3% (95% confidence interval [CI] 40.5-50.1%), the AADR was 10.9% (95% CI 8.1-14.3%), and the SPDR was 14.3% (95% CI 10.9-17.7%). Cancer was discovered in four patients (1%; 95% CI 0.2-2.5%). A total of 60.2% of all advanced adenoma (AA) were discovered on repeat colonoscopy. A colon segment scored BBPS = 0 had most AA (66.1%) and all four cancers. CONCLUSION: Patients with inadequate BP present a high rate of AAs on repeat colonoscopy. When a colonoscopy has a colon segment score BBPS = 0, we recommend repeating the colonoscopy as soon as possible.


Asunto(s)
Adenoma , Pólipos del Colon , Adenoma/diagnóstico , Catárticos , Pólipos del Colon/diagnóstico , Pólipos del Colon/patología , Colonoscopía , Humanos , Prevalencia , Estudios Prospectivos
6.
Endoscopy ; 52(11): 1026-1035, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32557475

RESUMEN

BACKGROUND: The most important predictor of unsuccessful bowel preparation is previous failure. For those patients with previous failure, we hypothesized that a nurse-led educational intervention by telephone shortly before the colonoscopy appointment could improve cleansing efficacy. METHODS: We performed a multicenter, endoscopist-blinded, randomized controlled trial. Consecutive outpatients with previous inadequate bowel preparation were enrolled. Both groups received the same standard bowel preparation protocol. The intervention group also received reinforced education by telephone within 48 hours before the colonoscopy. The primary outcome was effective bowel preparation according to the Boston Bowel Preparation Scale. Intention-to-treat (ITT) analysis included all randomized patients. Per-protocol analysis included patients who could be contacted by telephone and the control cases. RESULTS: 657 participants were recruited by 11 Spanish hospitals. In the ITT analysis, there was no significant difference between the intervention and control groups in the rate of successful bowel preparation (77.3 % vs. 72 %; P = 0.12). In the intervention group, 267 patients (82.9 %) were contacted by telephone. Per-protocol analysis revealed significantly improved bowel preparation in the intervention group (83.5 % vs. 72.0 %; P = 0.001). CONCLUSION: Among all patients with previous inadequate bowel preparation, nurse-led telephone education did not result in a significant improvement in bowel cleansing. However, in the 83 % of patients who could be contacted, bowel preparation was substantially improved. Phone education may therefore be a useful tool for improving the quality of bowel preparation in those cases.


Asunto(s)
Colonoscopía , Teléfono , Catárticos , Humanos , Análisis de Intención de Tratar , Polietilenglicoles , Estudios Prospectivos , Método Simple Ciego
7.
Rev Esp Enferm Dig ; 109(2): 152-154, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28196424

RESUMEN

Pyogenic granuloma is a non-infectious and non-granulomatous lesion. Its location in the small bowel is very rare. We present a 46 year-old woman with a chronic liver disorder that had a severe chronic anemia with occult blood losses. Upper endoscopy and colonoscopy were normal. A small bowel capsule endoscopy showed a pyogenic granuloma in jejunum that was resected endoscopically with single balloon enteroscopy with no major complications. The patient recovered from anemia and six months latter capsule endoscopy did not show lesions.


Asunto(s)
Endoscopía Gastrointestinal/métodos , Granuloma Piogénico/cirugía , Enfermedades del Yeyuno/cirugía , Síndrome de Inmunodeficiencia Adquirida/complicaciones , Endoscopía Capsular , Femenino , Granuloma Piogénico/diagnóstico por imagen , Hepatitis C Crónica/complicaciones , Humanos , Enfermedades del Yeyuno/diagnóstico por imagen , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA