Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros




Base de datos
Asunto principal
Intervalo de año de publicación
1.
Langenbecks Arch Surg ; 408(1): 152, 2023 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-37069276

RESUMEN

OBJECTIVE: Direct insertion of the trocar is an alternative method to Veress needle insertion for the creation of pneumoperitoneum. We conducted a systematic review and meta-analysis to compare these two entry closed techniques. DATA SOURCE: A systematic review of the literature was done on PubMed, MEDLINE, Embase, Scopus, and EBSCO. METHODS: The literature search was constructed until May 01, 2022, around search terms for "Veress," "direct trocar," "needle," "insertion," and "laparoscopic ways of entry." This systematic review was reported according to the PRISMA Statement 2020. RESULTS: Sixteen controlled trials (RCTs) and 5 observational studies were included in the systematic review. We found no significant differences in the risk of major complication during the access manoeuvres between DTI and VN: bowel injuries (OR = 0.76, 95% CI: 0.24-2.36, P = 0.63), major vascular injuries (OR = 1.74, 95% CI 0.56-5.38, P = 0.34), port site hernia (OR = 2.41, 95% CI: 0.28-20.71, P = 0.42). DTI has a lower risk of minor complications such as subcutaneous emphysema (OR = 5.19 95% CI: 2.27-11.87, P < 0.0001), extraperitoneal insufflation (OR = 5.93 95% CI: 1.69-20.87, P = 0.006), omental emphysema (OR = 18.41, 95% CI: 7. 01-48.34, P < 0.00001), omental bleeding (OR = 2.32, 95% CI: 1.18-4.55, P = 0.01), and lower number of unsuccessful entry or insufflation attempts (OR = 2.25, 95% CI: 1.05-4.81, P = 0.04). No significant differences were found between the two groups in terms of time required to achieve complete insufflation (MD = - 15.53, 95% CI: - 91.32 to 60.27, P = 0.69), trocar site bleeding (OR = 0.66, 95% CI, 0.25-1.79, P = 0.42), and trocar site infection (OR = 1.19, 95% CI, 0.34-4.20, P = 0.78). CONCLUSION: There were no statistically significant differences in the risk of major complications during the access manoeuvres between DTI and VN. A lower number of minor complications were observed in DTI compared with those in Veress access.


Asunto(s)
Laparoscopía , Humanos , Laparoscopía/efectos adversos , Laparoscopía/métodos , Instrumentos Quirúrgicos/efectos adversos , Neumoperitoneo Artificial/efectos adversos
2.
Appl Opt ; 35(34): 6839-41, 1996 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-21151279

RESUMEN

A gravity referenced optical inclinometer which uses a transparent fluid as angle-sensor element is described. Its principle of operation is based on light refraction at a free surface of the fluid. Measurements were carried out in an optical inclinometer built by the authors, and a resolution of 0.007° was obtained. The inclinometer permits real-time angle determinations along two perpendicular axis.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA