Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
2.
JACC Cardiovasc Interv ; 17(4): 552-560, 2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38418058

RESUMEN

BACKGROUND: Transcatheter tricuspid valve replacement (TTVR) abolishes tricuspid regurgitation (TR) and has emerged as a definitive treatment for TR. OBJECTIVES: The purpose of this multicenter, observational study was to determine the clinical characteristics and short-term outcomes of patients with TR screened for TTVR. METHODS: Patients underwent TTVR screening at 7 centers on a compassionate-use basis. The primary endpoints were NYHA functional class and TR grade at 30-day follow-up. Secondary endpoints included all-cause mortality, heart failure hospitalization, technical success, and reasons for TTVR screening failure. RESULTS: A total of 149 patients (median age 79 years [Q1-Q3: 72-84 years], 54% women) underwent TTVR screening. The TTVR screening failure rate was 74%, mainly related to large tricuspid annular diameter. Patients undergoing TTVR (n = 38) had significant functional improvements (NYHA functional class I or II from 21% to 68%; P < 0.001), with TR ≤1+ in 97% at 30-day follow-up (P < 0.001 from baseline). Technical success was achieved in 91%, with no intraprocedural mortality or conversion to surgery. At 30-day follow-up, mortality was 8%, heart failure hospitalization 5%, major bleeding 18%, and reintervention 9%. Patients who failed screening for TTVR and subsequently underwent "bailout" transcatheter edge-to-edge repair (n = 26) had favorable outcomes (NYHA functional class I or II from 27% to 58%; P < 0.001), with TR ≤1+ in 43% at 30-day follow-up (P < 0.001 from baseline). CONCLUSIONS: This first real-world report of TTVR screening demonstrated a high screening failure rate, mainly related to large tricuspid annular diameter. Patients undergoing TTVR had superior TR reduction and symptom alleviation compared with bailout tricuspid transcatheter edge-to-edge repair, at the cost of greater procedural complications.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Femenino , Anciano , Masculino , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Hemodinámica , Cateterismo Cardíaco/efectos adversos , Resultado del Tratamiento , Recuperación de la Función , Factores de Tiempo , Índice de Severidad de la Enfermedad , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Sistema de Registros
4.
Am J Cardiol ; 204: 32-39, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37536202

RESUMEN

Healthcare systems adopted various strategies to minimize the impact of the COVID-19 pandemic on clinical outcomes of patients with symptomatic severe aortic stenosis referred for transcatheter aortic valve implantation (TAVI). We aimed to compare baseline characteristics and procedural and clinical outcomes of patients who underwent TAVI during COVID-19 surge periods with those of patients who underwent TAVI during the nonsurge and prepandemic periods. In the prospective Bern TAVI registry, the pandemic period was divided into surge and nonsurge periods on the basis of the mean number of occupied beds in the intensive care unit in each month and matched with 11 months immediately preceding the pandemic. A total of 1,069 patients underwent TAVI between April 1, 2019 and December 31, 2021. Patients who underwent TAVI during surge periods had a higher surgical risk (Society of Thoracic Surgeons predicted risk of mortality) than that of patients who underwent TAVI during nonsurge and prepandemic periods. Diagnosis-to-procedure time (in days) was longer for patients who underwent TAVI during the surge period than during the nonsurge and prepandemic periods (95.20 ± 121.07 vs 70.99 ± 72.25 and 60.46 ± 75.43, both p <0.001). At 30 days, all-cause mortality was higher in the surge than in the nonsurge group (4.9 vs 1.1%, hazard ratio 4.68, 95% confidence interval 1.55 to 14.10, p = 0.006), and in the surge than in the prepandemic group (4.9 vs 1.3%, hazard ratio 3.67, 95% confidence interval 1.34 to 10.11, p = 0.012). In conclusion, TAVI during COVID-19 surge periods was associated with higher Society of Thoracic Surgeons predicted risk of mortality score, delayed procedure scheduling, and increased 30-day mortality than that of TAVI during nonsurge and prepandemic periods.


Asunto(s)
Estenosis de la Válvula Aórtica , COVID-19 , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/epidemiología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Resultado del Tratamiento , Estudios Prospectivos , Pandemias , Factores de Riesgo , COVID-19/epidemiología , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos
5.
Swiss Med Wkly ; 153: 40048, 2023 03 31.
Artículo en Inglés | MEDLINE | ID: mdl-37021783

RESUMEN

AIMS OF THE STUDY: Acquired haemophilia A is a rare disease with an annual incidence of 1.48 per million. Based on clinical observations, we suspect a higher incidence in southern Switzerland, and aimed at providing local epidemiological data, and clinical information regarding diagnosis, treatment and outcome in our region. METHODS: All adult patients with acquired haemophilia A treated between 2013 and 2019 in our facility were included in the present retrospective analysis. RESULTS: We treated 11 patients with acquired haemophilia A between 2013 and 2019, resulting in an annual incidence of 4.5 per million (95% confidence interval [CI] 0-9.0). Median delay from first symptoms to diagnosis was 4.5 days, and the median age at diagnosis was 79 years (range 23-87). Possible causative conditions were: pregnancy (n = 1), polyarteritis nodosa (n = 1), myelodysplastic syndrome (n = 1), chronic human immunodeficiency virus (HIV) (n = 1), and HIV postexposure prophylaxis (n = 1). In five patients no underlying or associated condition was identified. Median activated partial thromboplastin time (aPTT)) at baseline was 79 seconds (65-117; ref. value <38 sec), and FVIII:C 2.15% (<1-3.75%). A FVIII:C <1% was present in 4/10 patients. Median FVIII-inhibitor titre was 10.3 BU/ml (2.4-75.0 BU/ml). All patients had bleeding symptoms, 5/10 patients had major bleedings, and 7/10 patients were treated with bypassing agents. All patients received corticosteroids; 7/10 patients received immunosuppressive combination therapy. FVIII levels of ≥50% were achieved after a median of 40 days (8-62). One patient had a severe immunosuppressive therapy-related infection. An 87-years-old woman died for reasons not related to acquired haemophilia A or immunosuppressive therapy. CONCLUSIONS: Acquired haemophilia A is a rare disease, but manageable despite the advanced patient age and comorbidities. Its incidence in Southern Switzerland is higher than previously suspected.


Asunto(s)
Hemofilia A , Adulto , Embarazo , Femenino , Humanos , Adulto Joven , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Hemofilia A/complicaciones , Hemofilia A/tratamiento farmacológico , Estudios Retrospectivos , Suiza , Enfermedades Raras/complicaciones , Hemorragia
6.
Front Cardiovasc Med ; 9: 909204, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35911559

RESUMEN

Background: Microvascular obstruction (MVO) and Late Gadolinium Enhancement (LGE) assessed in cardiac magnetic resonance (CMR) are associated with adverse outcome in patients with ST-elevation myocardial infarction (STEMI). Our aim was to analyze the diagnostic performance of segmental strain for the detection of MVO and LGE. Methods: Patients with anterior STEMI, who underwent additional CMR were enrolled in this sub-study of the CARE-AMI trial. Using CMR feature tracking (FT) segmental circumferential peak strain (SCS) was measured and the diagnostic performance of SCS to discriminate MVO and LGE was assessed in a derivation and validation cohort. Results: Forty-eight STEMI patients (62 ± 12 years old), 39 (81%) males, who underwent CMR (i.e., mean 3.0 ± 1.5 days) after primary percutaneous coronary intervention (PCI) were included. All patients presented with LGE and in 40 (83%) patients, MVO was additionally present. Segments in all patients were visually classified and 146 (19%) segments showed MVO (i.e., LGE+/MVO+), 308 (40%) segments showed LGE and no MVO (i.e., LGE+/MVO-), and 314 (41%) segments showed no LGE (i.e., LGE-). Diagnostic performance of SCS for detecting MVO segments (i.e., LGE+/MVO+ vs. LGE+/MVO-, and LGE-) showed an AUC = 0.764 and SCS cut-off value was -11.2%, resulting in a sensitivity of 78% and a specificity of 67% with a positive predictive value (PPV) of 30% and a negative predictive value (NPV) of 94% when tested in the validation group. For LGE segments (i.e., LGE+/MVO+ and LGE+/MVO- vs. LGE-) AUC = 0.848 and SCS with a cut-off value of -13.8% yielded to a sensitivity of 76%, specificity of 74%, PPV of 81%, and NPV of 70%. Conclusion: Segmental strain in STEMI patients was associated with good diagnostic performance for detection of MVO+ segments and very good diagnostic performance of LGE+ segments. Segmental strain may be useful as a potential contrast-free surrogate marker to improve early risk stratification in patients after primary PCI.

7.
Front Cardiovasc Med ; 9: 1026230, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36698931

RESUMEN

Objectives: The objective of this study was to characterize a population of patients with severe tricuspid regurgitation (TR) evaluated at a tertiary care center, assess mid-term clinical outcomes, and identify prognostic factors. Background: The impact of TR on morbidity and mortality is increasingly recognized. Clinical characteristics and long-term outcomes of patients suffering from TR remain unclear. Methods: This is a retrospective observational single-center study from a tertiary care hospital including patients with echocardiographic diagnosis of severe TR between January 2017 and December 2018. We used the Kaplan-Meier method to estimate survival for up to 4 years. After excluding patients with tricuspid valve (TV) intervention and surgery during follow-up, a multivariate analysis was performed to assess predictors of 2-year mortality using the Cox regression model. Results: A total of 278 patients (mean age 74.9 ± 13.7 years, 47.8% female) with severe TR were included in the study. The majority (83.1%; n = 231) had secondary TR. Comorbidities such as atrial fibrillation (AFib) (68.0%; n = 189), severe renal failure (44.2%; n = 123), pulmonary hypertension (PHT) (80.9%; n = 225), and right ventricular (RV) dysfunction (59.7%; n = 166) were highly prevalent. More than half of patients with a cardiac implantable electronic device (CIED) (54.3%; n = 44) showed echocardiographic signs of lead-leaflet interaction causing or contributing to TR. The estimated 2- and 4-year all-cause mortality was 50 and 69%, respectively. Using multivariate analysis, age, severe renal failure, heart failure with reduced ejection fraction (HFrEF), and vena contracta width ≥14 mm were identified as predictors of 2-year mortality. Nine percent (n = 25) of the study cohort underwent transcatheter or surgical treatment for TR during follow-up. Conclusion: Our study shows the high burden of morbidity and the dismal survival of patients with severe TR. It also highlights the extent of the therapeutic need, since the vast majority of patients were left untreated. Additionally, CIED RV lead-associated TR was prevalent suggesting a need for more attention in clinical routine and research.

8.
Med Glas (Zenica) ; 17(2): 490-497, 2020 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-32329326

RESUMEN

Aim The gradual increase in shoulder implants in active elderly patients has appeared in a parallel increase in periprosthetic humeral fractures. The aim of this study was to investigate the advantages of using strut grafting with plate fixation during periprosthetic humerus fractures. Methods Thirty patients diagnosed with periprosthetic humeral fracture were divided into two groups. The first group of 15 patients (PS) underwent plate, ring, screws and strut allografts. The second group with resting 15 patients (PWS) was treated with only plate and screws. The criteria to evaluate the groups during followup were the Constant Shoulder Score (CSS) and Oxford Shoulder Score (OSS); the bone healing was measured by X-rays, controls measured by radiographic union score (RUS), and complications. The follow up was terminated at 12nd month in both groups. Results The difference between the two groups in all parameters was not significant. However, all patients gained adequate shoulder motor skills for normal daily living activities. All fractures were healed. Only two complications were registered, and blood loss was minimal. Conclusion We believe a revision to reverse shoulder prosthesis with a long-stem implant with or without cortical strut allograft augmentation to be safe and appropriate in the management of these complex injuries, though technically challenging, and having good results for normal activities daily life.


Asunto(s)
Fracturas del Húmero , Fracturas Periprotésicas , Anciano , Placas Óseas , Fijación Interna de Fracturas , Humanos , Fracturas del Húmero/cirugía , Húmero , Fracturas Periprotésicas/cirugía , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA