Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
2.
Clin Chem ; 51(10): 1946-54, 2005 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-16081505

RESUMEN

BACKGROUND: Researchers typically search for disease markers using a "targeted" approach in which a hypothesis about the disease mechanism is tested and experimental results either confirm or disprove the involvement of a particular gene or protein in the disease. Recently, there has been interest in developing disease diagnostics based on unbiased quantification of differences in global patterns of protein and peptide masses, typically in blood from individuals with and without disease. We combined a suite of methods and technologies, including novel sample preparation based on carrier-protein capture and biomarker enrichment, high-resolution mass spectrometry, a unique cohort of well-characterized persons with and without Alzheimer disease (AD), and powerful bioinformatic analysis, that add statistical and procedural robustness to biomarker discovery from blood. METHODS: Carrier-protein-bound peptides were isolated from serum samples by affinity chromatography, and peptide mass spectra were acquired by a matrix-assisted laser desorption/ionization (MALDI) orthogonal time-of-flight (O-TOF) mass spectrometer capable of collecting data over a broad mass range (100 to >300,000 Da) in a single acquisition. Discriminatory analysis of mass spectra was used to process and analyze the raw mass spectral data. RESULTS: Coupled with the biomarker enrichment protocol, the high-resolution MALDI O-TOF mass spectra provided informative, reproducible peptide signatures. The raw mass spectra were analyzed and used to build discriminant disease models that were challenged with blinded samples for classification. CONCLUSIONS: Carrier-protein enrichment of disease biomarkers coupled with high-resolution mass spectrometry and discriminant pattern analysis is a powerful technology for diagnostics and population screening. The mass fingerprint model successfully classified blinded AD patient and control samples with high sensitivity and specificity.


Asunto(s)
Enfermedad de Alzheimer/diagnóstico , Péptidos/química , Proteómica/métodos , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Enfermedad de Alzheimer/sangre , Enfermedad de Alzheimer/clasificación , Biomarcadores/sangre , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Péptidos/sangre , Péptidos/aislamiento & purificación , Sensibilidad y Especificidad
3.
J Am Soc Mass Spectrom ; 16(9): 1552-1560, 2005 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-16054389

RESUMEN

Metastable decomposition of ions generated in matrix-assisted laser desorption/ionization (MALDI) mass spectrometers complicates analysis of biological samples that have labile bonds. Recently, several academic laboratories and manufacturers of commercial instruments have designed instruments that introduce a cooling gas into the ion source during the MALDI event and have shown that the resulting vibrational cooling stabilizes these labile bonds. In this study, we compared stabilization and detection of desorbed gangliosides on a commercial orthogonal time-of-flight (oTOF) instrument with results we reported previously that had been obtained on a home-built Fourier transform mass spectrometer. Decoupling of the desorption/ionization from the detection steps resulted in an opportunity for desorbing thin-layer chromatography (TLC)-separated gangliosides directly from a TLC plate without compromising mass spectral accuracy and resolution of the ganglioside analysis, thus coupling TLC and oTOF mass spectrometry. The application of a declustering potential allowed control of the matrix cluster and matrix adduct formation, and, thus, enhanced the detection of the gangliosides.


Asunto(s)
Cromatografía en Capa Delgada/métodos , Gangliósidos/química , Manejo de Especímenes/métodos , Espectrometría de Masa por Ionización de Electrospray/métodos , Peso Molecular , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA