Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
ACS Omega ; 5(42): 27245-27253, 2020 Oct 27.
Artículo en Inglés | MEDLINE | ID: mdl-33134686

RESUMEN

New quinoline-based thiazole derivatives QPT and QBT were synthesized and characterized by various spectroscopic and single-crystal X-ray crystallographic studies. The metal-sensing properties of the probes were further examined by absorption and fluorescence spectrometry. The fluorescence intensity of QPT and QBT was remarkably quenched during the addition of Fe3+, Fe2+, and Cu2+ ions in THF/H2O (1:1) at pH = 7.4 in HEPES buffer, while the addition of other metal ions did not affect the fluorescence intensity of the ligands. The detection ability of the probes QPT and QBT was further investigated by titration with various equivalents of metal ions, optimized pH ranges for detection, and reversibility with Na2EDTA for biological applications.

2.
Spectrochim Acta A Mol Biomol Spectrosc ; 241: 118684, 2020 Nov 05.
Artículo en Inglés | MEDLINE | ID: mdl-32659705

RESUMEN

A new chemosensor (NANH) based on naphthyl moiety was synthesized with good selectivity and sensitivity towards Al3+ ions via the inhibition by operating through dual mechanisms like photo-induced electron transfer (PET) and excited-state intramolecular proton transfer (ESIPT). The synthesized NANH was validated by various techniques such as 1H, 13C NMR and mass spectrum. While prominent fluorescent enhancement was observed from the NANH upon binding with Al3+ ions, however, other metal ions have not responded in the emission spectrum. Detection limit and association constant of NANH for Al3+ were calculated as 1.2 × 10-7 M and 4.09 × 104 M-1 by using fluorescence titration method. Binding ratio (1:1) of NANH with Al3+ ions were proved by Job's plot and DFT studies. Furthermore, aluminium in variety of water samples was determined, and NANH could be used for biosensing of Al3+ in living cells.


Asunto(s)
Aluminio , Protones , Colorantes , Transporte de Electrón , Iones
3.
Bioorg Chem ; 97: 103709, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32146178

RESUMEN

A series of novel 8-nitro quinoline-based thiosemicarbazone analogues were synthesized and characterized by various spectroscopic and single crystal X-ray analyses. The potent antitumor effects of synthesized compounds towards the cancer cells were evaluated by MTT assay. Amongst, the compound 3a exhibited the highest inhibitory activity and the compounds 3f and 3b were also showed significant activity. The molecular mechanistic studies of cell death have demonstrated that the treated potent compound 3a induced G1/S & G2/M phase cell cycle arrest and induced apoptosis via mitochondrial dysfunction and increased the production of cytotoxic ROS levels. The RT-PCR gene expression analysis revealed that the cell death induced by activation of caspase-3 dependent intrinsic apoptotic signaling pathway. Further, the molecular binding affinity of compounds with estrogen receptor alpha was calculated by molecular docking studies. Thus, novel 8-nitro quinoline-thiosemicarbazone analogues provide a unique tool for breast cancer therapeutic tactics.


Asunto(s)
Antineoplásicos/química , Antineoplásicos/farmacología , Quinolinas/química , Quinolinas/farmacología , Tiosemicarbazonas/química , Tiosemicarbazonas/farmacología , Animales , Antineoplásicos/síntesis química , Antineoplásicos/farmacocinética , Apoptosis/efectos de los fármacos , Neoplasias de la Mama/tratamiento farmacológico , Neoplasias de la Mama/metabolismo , Puntos de Control del Ciclo Celular/efectos de los fármacos , Línea Celular Tumoral , Cristalografía por Rayos X , Femenino , Humanos , Ratones Endogámicos BALB C , Ratones Desnudos , Mitocondrias/efectos de los fármacos , Mitocondrias/metabolismo , Modelos Moleculares , Simulación del Acoplamiento Molecular , Quinolinas/síntesis química , Quinolinas/farmacocinética , Especies Reactivas de Oxígeno/metabolismo , Tiosemicarbazonas/síntesis química , Tiosemicarbazonas/farmacocinética , Neoplasias del Cuello Uterino/tratamiento farmacológico , Neoplasias del Cuello Uterino/metabolismo
4.
Medchemcomm ; 10(3): 439-449, 2019 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-31015907

RESUMEN

A series of unique dispiro analogues containing an oxindole pyrrolidine 8-nitroquinolone hybrid has been obtained through a one-pot three-component 1,3-dipolar cycloaddition of azomethine ylides generated in situ from the condensation of isatins and benzylamine with (E)-3-arylidene-2,3-dihydro-8-nitro-4-quinolones. The structures of the newly synthesized compounds were characterized by using different spectroscopic techniques and by X-ray diffraction studies of their regio- and stereochemistry. All the synthesized compounds were screened for in vitro cytotoxic activity against the human cervical cancer cell line HeLa. The compounds have exhibited potent inhibition against human cervical cancer cells and insignificant toxicity to normal cells. The compounds 6d, 6a, 6h, 6b, and 6e induced apoptosis of HeLa cells, through ROS influx. The expression levels of proteins involved in the mitochondrion-related pathways were detected, and Western blot analysis showed that apoptosis occurred via activation of caspase-3.

5.
Talanta ; 198: 249-256, 2019 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-30876558

RESUMEN

A new simple pyrene based schiff base chemosensor 1 (nicotinic acid pyren-1-ylmethylene-hydrazide) has been constructed and is prepared from 1-pyrenecarboxaldehyde and nicotinic hydrazide. Notably, the chemosensor 1 exhibited remarkable colour changes while in the presence of trivalent metal ions like Bi3+ & Al3+ ion in DMSO-H2O, (1:1 v/v, HEPES = 50 mM, pH = 7.4). The UV-Vis spectral investigation of chemosensor 1 showed that the maximum absorption peak appeared at 378 nm. In emission studies, chemosensor 1 develops weak fluorescence, while upon the addition of Bi3+ and Al3+ ions, it exhibits an enhancement of fluorescence intensity. Nevertheless, rest of metal ions have no changes in the emission spectra. The association constant of chemosensor 1 for binding to Bi3+ & Al3+ system had a value of 1.27 × 104 M-1 and 1.53 × 104 M-1. The detection limits were 0.12 µM for Bi3+ and 0.17 µM for Al3+ respectively. The overall results reveal that chemosensor 1 can act as a dual-channel, highly selective, and sensitive probe for Bi3+ and Al3+ ions. Moreover, the fluorescence imaging of chemosensor 1 was applied in RAW 264.7 cell line and cytotoxicity assay prove that this chemosensor 1 is non-toxic as well as highly biocompatible.


Asunto(s)
Aluminio/análisis , Bismuto/análisis , Colorantes Fluorescentes/química , Imagen Óptica , Pirenos/química , Animales , Iones/análisis , Ratones , Células RAW 264.7 , Espectrometría de Fluorescencia
6.
BMC Gastroenterol ; 16(1): 133, 2016 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-27737636

RESUMEN

BACKGROUND: Adequate bowel preparation is an essential prerequisite for complete mucosal visualization during colonoscopy. Polyethylene glycol (PEG) solutions are commonly used. However the large volume of the solution is often poorly tolerated. Addition of Lubiprostone (LB) could improve the adequacy of standard PEG preparation & reduce requirement. The aims to assess adequacy of PEG preparation with addition of single dose LB (24mcg) vs placebo and efficacy of reduced dose PEG + LB compared with full dose PEG + LB. METHODS: Single center prospective double blind randomized controlled trial. Part I: 442 patients for colonoscopy randomized to receive placebo (GrA) or single dose of LB (GrB) prior to PEG preparation. Quality of bowel preparation graded 0-9 according to Boston Bowel Preparation Scale (BBPS). BBPS-9: excellent and BBPS 0-4: repeat procedure. Part II: 146 patients randomized to receive LB + 1.5 L PEG (GrC; 75) or LB + 1 L PEG (GrD; 71). BBPS score compared with GrB (2 L PEG). RESULTS: Part I: 442 patients (221 GrA & 221 Gr B). LB resulted in significant improvement in total BBPS (7.44 + 0.14 vs. 6.36 + 0.16, p < 0.0001). 66.5 % Gr B vs 38 % Gr A had excellent prep; 42.5 % GrB vs 24 % GrA had adequate prep. Repeat procedure needed 9.5 % Gr B vs 16.7 % Gr A (P < 0.01). Part II: No difference in BBPS scores with lower doses (Gr C&D) compared to standard (GrB) (Mean BBPS 7.44 + 0.14 GrA,7.30 + 0.25 GrC;7.25 + 0.26 GrD;p >0.05). CONCLUSION: Single dose LB prior to PEG significantly enhanced bowel preparation compared to PEG alone. There was no significant difference in quality of preparation with lower doses of PEG when combined with LB. TRIAL REGISTRATION: The study protocol was approved by institutional review board and the trial was registered on March 22, 2011 with clinicaltrials.gov ( NCT01324284 ).


Asunto(s)
Catárticos/administración & dosificación , Colonoscopía , Lubiprostona/administración & dosificación , Polietilenglicoles/administración & dosificación , Cuidados Preoperatorios/métodos , Adulto , Método Doble Ciego , Quimioterapia Combinada , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento
7.
Indian J Gastroenterol ; 31(6): 324-32, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22996048

RESUMEN

AIM: Ampullary tumors are rare. Reports on ampullary tumor staging are heterogeneous and combine both periampullary and ampullary tumors. This study assessed the performance of endoscopic ultrasound (EUS) in the local staging of ampullary tumors only. METHODS: Data were collected retrospectively. We included patients with an ampullary tumor who underwent EUS and surgical resection. Tumor (T) and nodal (N) TNM staging for EUS and histopathological (HP) staging were compared. RESULTS: From 2009 to 2010, a total of 79 patients with ampullary tumors were identified. Of these, 26 had both EUS and Whipple's surgery and were included (28 did not undergo resection, 13 had palliative surgery only and 12 had resection without EUS). For T staging by HP, there were 2 (7.7 %) T1, 11 (42.3 %) T2, 12 (46.2 %) T3 and 1 (3.8 %) T4 tumors. The accuracy of EUS T staging was 73.1 % with a Kappa value of 0.564 (p < 0.0001). The sensitivity, specificity, positive predictive value (PPV), negative predictive values (NPV) of EUS, respectively were 50.0 %, 91.7 %, 33.3 % and 95.7 % for T1 tumors; 81.8 %, 80.0 %, 75.0 % and 85.7 % for T2; 75.0 %, 92.9 %, 90.0 % and 81.3 % for T3 tumors. For N staging by HP, 17 (65.4 %) were N0 and 9 (34.6 %) N1. The N staging diagnostic accuracy was 80.8 % with a Kappa value of 0.586 (p = 0.003). The sensitivity, specificity, PPV, NPV for N0 disease were 82.4 %, 77.8 %, 87.5 % and 70.0 %, respectively while for N1 they were 77.8 %, 82.4 %, 70.0 % and 87.5 %, respectively. CONCLUSIONS: EUS had a moderate strength of agreement with histopathology for both T and N staging, and a high diagnostic accuracy for nodal staging.


Asunto(s)
Adenocarcinoma/patología , Adenoma/diagnóstico por imagen , Adenoma/patología , Ampolla Hepatopancreática , Neoplasias del Conducto Colédoco/diagnóstico por imagen , Neoplasias del Conducto Colédoco/patología , Adenocarcinoma/diagnóstico por imagen , Adulto , Endosonografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Valor Predictivo de las Pruebas , Estudios Retrospectivos
8.
BMC Gastroenterol ; 11: 86, 2011 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-21798022

RESUMEN

BACKGROUND: Risk factors for poor bowel preparation are recognized to be independent of the type of bowel preparation method used. Patient and administrative factors influencing bowel preparation are known to vary in different healthcare systems. METHODS: A prospective, cross-sectional study of patients undergoing colonoscopy in an Asian tertiary centre was conducted to identify risk factors associated with poor bowel preparation, and to evaluate the impact of poor bowel preparation on technical performance and patient comfort. RESULTS: Data on 501 patients (mean age 60.1 ± 14.0 years old, 51.2% males, 60.9% with secondary education or higher) was available for analysis. Poor bowel preparation was present in 151 patients (30.1%). Lower education level (OR = 2.35, 95% CI = 1.54 - 3.60), colonoscopy appointment waiting time beyond 16 weeks (OR = 1.86, 95% CI = 1.04 - 3.37) and non-adherence to bowel preparation instructions (OR = 4.76, 95% CI = 3.00 - 7.55) were identified as independent risk factors for poor bowel preparation. Poor bowel preparation was associated with a lower cecal intubation rate (78.1% versus 98.3%, p < 0.001), prolonged total colonoscopy time (25.4 ± 12.6 minutes versus 16.7 ± 10.2 minutes, p < 0.001), and increased patient discomfort during colonoscopy (patient with moderate to severe abdominal discomfort 31.8% versus 3.2%, p < 0.001). CONCLUSIONS: Education levels and appointment waiting times, in addition to non-adherence to bowel preparation instructions, increase the risk of poor bowel preparation in adult patients undergoing colonoscopy. The latter has a significant impact on colonoscopy performance and patient comfort.


Asunto(s)
Citas y Horarios , Catárticos/administración & dosificación , Colonoscopía/normas , Escolaridad , Cooperación del Paciente , Anciano , Estudios de Cohortes , Enfermedades del Colon/diagnóstico , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Riesgo , Listas de Espera
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA