Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros




Base de datos
Asunto principal
Intervalo de año de publicación
1.
Biomed Opt Express ; 15(2): 1278-1287, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38404299

RESUMEN

The ability to perceive polarization-related entoptic phenomena arises from the dichroism of macular pigments held in Henle's fiber layer of the retina and can be inhibited by retinal diseases, such as age-related macular degeneration, which alters the structure of the macula. Structured light tools enable the direct probing of macular pigment density and retinal structure through the perception of polarization-dependent entoptic patterns. Here, we directly measure the visual angle of an entoptic pattern created through the illumination of the retina with a structured state of light and a perception task that is insensitive to corneal birefringence. The central region of the structured light stimuli was obstructed, with the size of the obstruction varying according to a psychophysical staircase. Two stimuli, one producing 11 azimuthal fringes and the other three azimuthal fringes, were presented to 24 healthy participants. The pattern with 11 azimuthal fringes produced an average visual angle threshold of 10° ± 1° and a 95% confidence interval (C.I.) of [6°, 14°]. For the pattern with three azimuthal fringes, a threshold extent of 3.6° ± 0.3° C.I. = [1.3°, 5.8°] was measured, a value similar to the published extent of Haidinger's brush (4°). The increase in apparent size and clarity of entoptic phenomena produced by the presented structured light stimuli offers the potential to detect the early signs of macular disease over perception tasks using uniform polarization stimuli.

2.
Sci Rep ; 12(1): 3245, 2022 02 28.
Artículo en Inglés | MEDLINE | ID: mdl-35228565

RESUMEN

We tested the ability of human observers to discriminate distinct profiles of spatially dependant geometric phases when directly viewing stationary structured light beams. Participants viewed polarization coupled orbital angular momentum (OAM) states, or "spin-orbit" states, in which the OAM was induced through Pancharatnam-Berry phases. The coupling between polarization and OAM in these beams manifests as spatially dependant polarization. Regions of uniform polarization are perceived as specifically oriented Haidinger's brushes, and study participants discriminated between two spin-orbit states based on the rotational symmetry in the spatial orientations of these brushes. Participants used self-generated eye movements to prevent adaptation to the visual stimuli. After initial training, the participants were able to correctly discriminate between two spin-orbit states, differentiated by OAM [Formula: see text], with an average success probability of [Formula: see text] ([Formula: see text], [Formula: see text]). These results support our previous observation that human observers can directly perceive spin-orbit states, and extend this finding to non-rotating beams, OAM modes induced via Pancharatnam-Berry phases, and the discrimination of states that are differentiated by OAM.


Asunto(s)
Refracción Ocular , Humanos , Movimientos Oculares , Matemática , Movimiento (Física)
3.
IUCrJ ; 7(Pt 5): 893-900, 2020 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-32939281

RESUMEN

Neutrons are valuable probes for various material samples across many areas of research. Neutron imaging typically has a spatial resolution of larger than 20 µm, whereas neutron scattering is sensitive to smaller features but does not provide a real-space image of the sample. A computed-tomography technique is demonstrated that uses neutron-scattering data to generate an image of a periodic sample with a spatial resolution of ∼300 nm. The achieved resolution is over an order of magnitude smaller than the resolution of other forms of neutron tomography. This method consists of measuring neutron diffraction using a double-crystal diffractometer as a function of sample rotation and then using a phase-retrieval algorithm followed by tomographic reconstruction to generate a map of the sample's scattering-length density. Topological features found in the reconstructions are confirmed with scanning electron micrographs. This technique should be applicable to any sample that generates clear neutron-diffraction patterns, including nanofabricated samples, biological membranes and magnetic materials, such as skyrmion lattices.

4.
Phys Rev Lett ; 121(18): 183602, 2018 Nov 02.
Artículo en Inglés | MEDLINE | ID: mdl-30444408

RESUMEN

We describe a highly robust method, applicable to both electromagnetic and matter-wave beams, that can produce a beam consisting of a lattice of orbital angular momentum (OAM) states coupled to a two-level system. We also define efficient protocols for controlling and manipulating the lattice characteristics. These protocols are applied in an experimental realization of a lattice of optical spin-orbit beams. The novel passive devices we demonstrate here are also a natural alternative to existing methods for producing single-axis OAM and spin-orbit beams. Our techniques provide new tools for investigations of chiral and topological materials with light and particle beams.

5.
Phys Rev Lett ; 120(11): 113201, 2018 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-29601748

RESUMEN

We demonstrate a three phase-grating moiré neutron interferometer in a highly intense neutron beam as a robust candidate for large area interferometry applications and for the characterization of materials. This novel far-field moiré technique allows for broad wavelength acceptance and relaxed requirements related to fabrication and alignment, thus circumventing the main obstacles associated with perfect crystal neutron interferometry. We observed interference fringes with an interferometer length of 4 m and examined the effects of an aluminum 6061 alloy sample on the coherence of the system. Experiments to measure the autocorrelation length of samples and the universal gravitational constant are proposed and discussed.

6.
Rev Sci Instrum ; 89(2): 023502, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29495801

RESUMEN

We find that annealing a previously chemically etched interferometer at 800 °C dramatically increased the interference fringe visibility from 23% to 90%. The Bragg plane misalignments were also measured before and after annealing using neutron rocking curves, showing that Bragg plane alignment was improved across the interferometer after annealing. This suggests that current interferometers with low fringe visibility may be salvageable and that annealing may become an important step in the fabrication process of future neutron interferometers, leading to less need for chemical etching and larger more exotic neutron interferometers.

7.
New J Phys ; 20(10)2018.
Artículo en Inglés | MEDLINE | ID: mdl-34858077

RESUMEN

The generation and control of neutron orbital angular momentum (OAM) states and spin correlated OAM (spin-orbit) states provides a powerful probe of materials with unique penetrating abilities and magnetic sensitivity. We describe techniques to prepare and characterize neutron spin-orbit states, and provide a quantitative comparison to known procedures. The proposed detection method directly measures the correlations of spin state and transverse momentum, and overcomes the major challenges associated with neutrons, which are low flux and small spatial coherence length. Our preparation techniques, utilizing special geometries of magnetic fields, are based on coherent averaging and spatial control methods borrowed from nuclear magnetic resonance. The described procedures may be extended to other probes such as electrons and electromagnetic waves.

8.
J Appl Phys ; 122(5)2017.
Artículo en Inglés | MEDLINE | ID: mdl-34916709

RESUMEN

We provide a quantum information description of a proposed five-blade neutron interferometer geometry and show that it is robust against low-frequency mechanical vibrations and dephasing due to the dynamical phase. The extent to which the dynamical phase affects the contrast in a neutron interferometer is experimentally shown. In our model, we consider the coherent evolution of a neutron wavepacket in an interferometer crystal blade and simulate the effect of mechanical vibrations and momentum spread of the neutron through the interferometer. The standard three-blade neutron interferometer is shown to be immune to dynamical phase noise but prone to noise from mechanical vibrations, and the decoherence free subspace four-blade neutron interferometer is shown to be immune to mechanical vibration noise but prone to noise from the dynamical phase. Here, we propose a five-blade neutron interferometer and show that it is immune to both low-frequency mechanical vibration noise and dynamical phase noise.

9.
Rev Sci Instrum ; 87(12): 123507, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28040910

RESUMEN

Neutron interferometry enables precision measurements that are typically operated within elaborate, multi-layered facilities which provide substantial shielding from environmental noise. These facilities are necessary to maintain the coherence requirements in a perfect crystal neutron interferometer which is extremely sensitive to local environmental conditions such as temperature gradients across the interferometer, external vibrations, and acoustic waves. The ease of operation and breadth of applications of perfect crystal neutron interferometry would greatly benefit from a mode of operation which relaxes these stringent isolation requirements. Here, the INDEX Collaboration and National Institute of Standards and Technology demonstrates the functionality of a neutron interferometer in vacuum and characterize the use of a compact vacuum chamber enclosure as a means to isolate the interferometer from spatial temperature gradients and time-dependent temperature fluctuations. The vacuum chamber is found to have no depreciable effect on the performance of the interferometer (contrast) while improving system stability, thereby showing that it is feasible to replace large temperature isolation and control systems with a compact vacuum enclosure for perfect crystal neutron interferometry.

10.
Phys Rev D ; 93(6)2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34859165

RESUMEN

The physical origin of the dark energy that causes the accelerated expansion rate of the Universe is one of the major open questions of cosmology. One set of theories postulates the existence of a self-interacting scalar field for dark energy coupling to matter. In the chameleon dark energy theory, this coupling induces a screening mechanism such that the field amplitude is nonzero in empty space but is greatly suppressed in regions of terrestrial matter density. However measurements performed under appropriate vacuum conditions can enable the chameleon field to appear in the apparatus, where it can be subjected to laboratory experiments. Here we report the most stringent upper bound on the free neutron-chameleon coupling in the strongly coupled limit of the chameleon theory using neutron interferometric techniques. Our experiment sought the chameleon field through the relative phase shift it would induce along one of the neutron paths inside a perfect crystal neutron interferometer. The amplitude of the chameleon field was actively modulated by varying the millibar pressures inside a dual-chamber aluminum cell. We report a 95% confidence level upper bound on the neutron-chameleon coupling ß ranging from ß < 4.7 × 106 for a Ratra-Peebles index of n = 1 in the nonlinear scalar field potential to ß < 2.4 × 107 for n = 6, one order of magnitude more sensitive than the most recent free neutron limit for intermediate n. Similar experiments can explore the full parameter range for chameleon dark energy in the foreseeable future.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA