Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 109
Filtrar
1.
EuroIntervention ; 19(4): e323-e329, 2023 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-37306039

RESUMEN

Dual antiplatelet therapy (DAPT) is currently the standard of care after percutaneous coronary intervention (PCI). Recent studies suggest that reducing DAPT to 1-3 months followed by an aspirin-free single antiplatelet therapy (SAPT) strategy with a potent P2Y12 inhibitor is safe and associated with less bleeding. However, to date, no randomised trial has tested the impact of initiating SAPT immediately after PCI, particularly in patients with acute coronary syndromes (ACS). NEOMINDSET is a multicentre, randomised, open-label trial with a blinded outcome assessment designed to compare SAPT versus DAPT in 3,400 ACS patients undergoing PCI with the latest-generation drug-eluting stents (DES). After successful PCI and up to 4 days following hospital admission, patients are randomised to receive SAPT with a potent P2Y12 inhibitor (ticagrelor or prasugrel) or DAPT (aspirin plus a potent P2Y12 inhibitor) for 12 months. Aspirin is discontinued immediately after randomisation in the SAPT group. The choice between ticagrelor and prasugrel is at the investigator's discretion. The primary hypothesis is that SAPT will be non-inferior to DAPT with respect to the composite endpoint of all-cause mortality, stroke, myocardial infarction or urgent target vessel revascularisation, but superior to DAPT on rates of bleeding defined by Bleeding Academic Research Consortium 2, 3 or 5 criteria. NEOMINDSET is the first study that is specifically designed to test SAPT versus DAPT immediately following PCI with DES in ACS patients. This trial will provide important insights on the efficacy and safety of withdrawing aspirin in the early phase of ACS. (ClinicalTrials.gov: NCT04360720).


Asunto(s)
Síndrome Coronario Agudo , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Humanos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Ticagrelor/uso terapéutico , Síndrome Coronario Agudo/tratamiento farmacológico , Síndrome Coronario Agudo/cirugía , Clorhidrato de Prasugrel/uso terapéutico , Intervención Coronaria Percutánea/efectos adversos , Quimioterapia Combinada , Aspirina/uso terapéutico , Hemorragia/inducido químicamente , Resultado del Tratamiento
2.
Tex Heart Inst J ; 50(2)2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36944120

RESUMEN

BACKGROUND: The transradial approach (TRA) to coronary angiography reduces vascular complications but is associated with greater radiation exposure than the transfemoral approach (TFA). It is unknown whether exposure remains higher when TRA is performed by experienced operators. METHODS: Patients were randomly, prospectively assigned to TRA or TFA. The primary end point was patient radiation dose; secondary end points were the physician radiation dose and 30-day major adverse cardiac event rate. Coronary angiography was performed by experienced operators using a standardized protocol. RESULTS: Clinical and procedural characteristics were similar between the TRA (n = 150) and TFA (n = 149) groups, and they had comparable mean (SD) radiation doses for patients (616.51 [252] vs 585.57 [225] mGy; P = .13) and physicians (0.49 [0.3] vs 0.46 [0.29] mSv; P = .32). The mean (SD) fluoroscopy time (3.52 [2.02] vs 3.13 [2.46] min; P = .14) and the mean (SD) dose area product (35,496.5 [15,670] vs 38,313.4 [17,764.9] mGy·cm2; P = .2) did not differ. None of the following factors predicted higher radiation doses: female sex (hazard ratio [HR], 0.69 [95% CI, 0.38-1.3]; P = .34), body mass index >25 (HR, 0.84 [95% CI, 0.43-1.6]; P = .76), age >65 years (HR, 1.67 [95% CI, 0.89-3.1]; P = .11), severe valve disease (HR, 1.37 [95% CI, 0.52-3.5]; P = .68), or previous coronary artery bypass graft (HR, 0.6; 95% CI, 0.2-1.8; P = .38). CONCLUSION: TRA for elective coronary angiography is noninferior to TFA when performed by experienced operators.


Asunto(s)
Intervención Coronaria Percutánea , Exposición a la Radiación , Humanos , Femenino , Anciano , Angiografía Coronaria/efectos adversos , Angiografía Coronaria/métodos , Exposición a la Radiación/efectos adversos , Exposición a la Radiación/prevención & control , Factores de Tiempo , Arteria Radial , Arteria Femoral , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Resultado del Tratamiento
5.
J Am Heart Assoc ; 10(18): e020682, 2021 09 21.
Artículo en Inglés | MEDLINE | ID: mdl-34546114

RESUMEN

Background No study has evaluated the impact of the additional manipulation demanded by multiple resheathing (MR) in patients undergoing transcatheter aortic valve replacement with repositionable self-expanding valves. Methods and Results This study included a real-world, multicenter registry involving 16 centers from Canada, Germany, Latin America, and Spain. All consecutive patients who underwent transcatheter aortic valve replacement with the Evolut R, Evolut PRO, and Portico valves were included. Patients were divided according to the number of resheathing: no resheathing, single resheathing (SR), and MR. The primary end point was device success. Secondary outcomes included procedural complications, early safety events, and 1-year mortality. In 1026 patients, the proportion who required SR and MR was 23.9% and 9.3%, respectively. MR was predicted by the use of Portico and moderate/severe aortic regurgitation at baseline (both with P<0.01). Patients undergoing MR had less device success (no resheathing=89.9%, SR=89.8%, and MR=80%; P=0.01), driven by more need for a second prosthesis and device embolization. At 30 days, there were no differences in safety events. At 1 year, more deaths occurred with MR (no resheathing=10.5%, SR=8.0%, and MR=18.8%; P=0.014). After adjusting for baseline differences and center experience by annual volume, MR associated with less device success (odds ratio, 0.42; P=0.003) and increased 1-year mortality (hazard ratio, 2.06; P=0.01). When including only the Evolut R/PRO cases (N=837), MR continued to have less device success (P<0.001) and a trend toward increased mortality (P=0.05). Conclusions Repositioning a self-expanding valve is used in a third of patients, being multiple in ≈10%. MR, but not SR, was associated with more device failure and higher 1-year mortality, regardless of the type of valve implanted.


Asunto(s)
Reemplazo de la Válvula Aórtica Transcatéter , Catéteres , Humanos , Incidencia , Oportunidad Relativa , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
6.
Arq Bras Cardiol ; 116(6): 1059-1069, 2021 06.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-34133587

RESUMEN

BACKGROUND: Mitral regurgitation (MR) is prevalent in patients undergoing transcatheter aortic valve implantation (TAVI). There are some controversies about the prognostic impact of MR in survival of TAVI patients. OBJECTIVE: To examine the relationship between TAVI and MR in a patient population from the Brazilian TAVI Registry. METHODS: Seven hundred and ninety-five patients from the Brazilian TAVI Registry were divided at baseline, discharge, and follow-up according to their MR grade as follows: absent/mild (AMMR) or moderate/severe (MSMR). They were subsequently regrouped according to their immediate and late changes in MR severity after TAVI as follows: no change, improved, or worsened MR. Predictors and prognostic impact on baseline as well as changes in MR severity were analyzed. Statistical significance was set at p < 0.05. RESULTS: Baseline MSMR was present in 19.3% of patients and was a predictor of increased late mortality. Immediately after TAVI, 47.4 % of cases improved to AMMR, predicted by a higher Society of Thoracic Surgeons score and a higher grade of baseline aortic regurgitation. Upon follow-up, 9.2% of cases of AMMR worsened to MSMR, whereas 36.8% of cases of MSMR improved to AMMR. Lower baseline left ventricular ejection fraction (LVEF) and improvement in LVEF at follow-up were predictors of MR improvement. Progressive worsening of MR upon follow-up was an independent predictor of higher late mortality after TAVI (p = 0.005). CONCLUSIONS: Baseline MSMR predicts late mortality after TAVI. Lower LVEF and improved LVEF at follow-up predict MR improvement after TAVI. Progressive worsening of MR severity at follow-up is an independent predictor of late mortality, which is a rare finding in the literature.


FUNDAMENTO: A regurgitação mitral (RM) é prevalente em pacientes submetidos a implante transcateter de válvula aórtica (TAVI). Há algumas controvérsias sobre o impacto prognóstico da RM na sobrevida de pacientes submetidos a TAVI. OBJETIVO: Examinar a relação entre TAVI e RM em uma população de pacientes do Registro Brasileiro de TAVI. MÉTODOS: Setecentos e noventa e cinco pacientes do Registro Brasileiro de TAVI foram divididos na linha de base, alta e acompanhamento de acordo com o grau da RM da maneira seguinte: ausente/leve (RMAL) ou moderado/grave (RMMG). Eles foram subsequentemente reagrupados de acordo com as mudanças imediatas e tardias na gravidade da RM após TAVI da maneira seguinte: RM sem mudança, melhora ou piora. Foram analisados os preditores e o impacto prognóstico na linha de base, bem como as mudanças na gravidade da RM. A significância estatística foi estabelecida em p < 0,05. RESULTADOS: RMMG basal estava presente em 19,3% dos pacientes e foi um preditor de aumento da mortalidade tardia. Imediatamente após o TAVI, 47,4% dos casos melhoraram para RMAL, previsto por uma pontuação mais alta da Society of Thoracic Surgeons e um grau mais alto de regurgitação aórtica basal. No acompanhamento, 9,2% dos casos de RMAL pioraram para RMMG, enquanto 36,8% dos casos de RMMG melhoraram para RMAL. Fração de ejeção do ventrículo esquerdo (FEVE) mais baixa na linha de base e melhora na FEVE durante o acompanhamento foram preditores de melhora da RM. Piora progressiva da RM no acompanhamento foi um preditor independente de maior mortalidade tardia após TAVI (p = 0,005). CONCLUSÕES: A RMMG na linha de base é um preditor de mortalidade tardia após TAVI. FEVE mais baixa e melhora na FEVE durante o acompanhamento são preditores de melhora da RM após TAVI. A pior progressiva da gravidade da RM durante o acompanhamento é um preditor independente de mortalidade tardia; isto é um achado raro na literatura.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Brasil , Estudios de Seguimiento , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Índice de Severidad de la Enfermedad , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
7.
Arq. bras. cardiol ; 116(6): 1059-1069, Jun. 2021. tab, graf
Artículo en Inglés, Portugués | LILACS | ID: biblio-1278328

RESUMEN

Resumo Fundamento A regurgitação mitral (RM) é prevalente em pacientes submetidos a implante transcateter de válvula aórtica (TAVI). Há algumas controvérsias sobre o impacto prognóstico da RM na sobrevida de pacientes submetidos a TAVI. Objetivo Examinar a relação entre TAVI e RM em uma população de pacientes do Registro Brasileiro de TAVI. Métodos Setecentos e noventa e cinco pacientes do Registro Brasileiro de TAVI foram divididos na linha de base, alta e acompanhamento de acordo com o grau da RM da maneira seguinte: ausente/leve (RMAL) ou moderado/grave (RMMG). Eles foram subsequentemente reagrupados de acordo com as mudanças imediatas e tardias na gravidade da RM após TAVI da maneira seguinte: RM sem mudança, melhora ou piora. Foram analisados os preditores e o impacto prognóstico na linha de base, bem como as mudanças na gravidade da RM. A significância estatística foi estabelecida em p < 0,05. Resultados RMMG basal estava presente em 19,3% dos pacientes e foi um preditor de aumento da mortalidade tardia. Imediatamente após o TAVI, 47,4% dos casos melhoraram para RMAL, previsto por uma pontuação mais alta da Society of Thoracic Surgeons e um grau mais alto de regurgitação aórtica basal. No acompanhamento, 9,2% dos casos de RMAL pioraram para RMMG, enquanto 36,8% dos casos de RMMG melhoraram para RMAL. Fração de ejeção do ventrículo esquerdo (FEVE) mais baixa na linha de base e melhora na FEVE durante o acompanhamento foram preditores de melhora da RM. Piora progressiva da RM no acompanhamento foi um preditor independente de maior mortalidade tardia após TAVI (p = 0,005). Conclusões A RMMG na linha de base é um preditor de mortalidade tardia após TAVI. FEVE mais baixa e melhora na FEVE durante o acompanhamento são preditores de melhora da RM após TAVI. A pior progressiva da gravidade da RM durante o acompanhamento é um preditor independente de mortalidade tardia; isto é um achado raro na literatura.


Abstract Background Mitral regurgitation (MR) is prevalent in patients undergoing transcatheter aortic valve implantation (TAVI). There are some controversies about the prognostic impact of MR in survival of TAVI patients. Objective To examine the relationship between TAVI and MR in a patient population from the Brazilian TAVI Registry. Methods Seven hundred and ninety-five patients from the Brazilian TAVI Registry were divided at baseline, discharge, and follow-up according to their MR grade as follows: absent/mild (AMMR) or moderate/severe (MSMR). They were subsequently regrouped according to their immediate and late changes in MR severity after TAVI as follows: no change, improved, or worsened MR. Predictors and prognostic impact on baseline as well as changes in MR severity were analyzed. Statistical significance was set at p < 0.05. Results Baseline MSMR was present in 19.3% of patients and was a predictor of increased late mortality. Immediately after TAVI, 47.4 % of cases improved to AMMR, predicted by a higher Society of Thoracic Surgeons score and a higher grade of baseline aortic regurgitation. Upon follow-up, 9.2% of cases of AMMR worsened to MSMR, whereas 36.8% of cases of MSMR improved to AMMR. Lower baseline left ventricular ejection fraction (LVEF) and improvement in LVEF at follow-up were predictors of MR improvement. Progressive worsening of MR upon follow-up was an independent predictor of higher late mortality after TAVI (p = 0.005). Conclusions Baseline MSMR predicts late mortality after TAVI. Lower LVEF and improved LVEF at follow-up predict MR improvement after TAVI. Progressive worsening of MR severity at follow-up is an independent predictor of late mortality, which is a rare finding in the literature.


Asunto(s)
Humanos , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Insuficiencia de la Válvula Mitral/cirugía , Válvula Aórtica/cirugía , Volumen Sistólico , Índice de Severidad de la Enfermedad , Brasil , Estudios de Seguimiento , Función Ventricular Izquierda , Resultado del Tratamiento
8.
PLoS One ; 16(5): e0251066, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33984005

RESUMEN

BACKGROUND: Chronic kidney disease is commonly found in patients with aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) and has marked impact in their prognosis. It has been shown however that TAVR may improve renal function by alleviating the hemodynamic barrier imposed by AS. Nevertheless, the predictors of and clinical consequences of renal function improvement are not well established. Our aim was to assess the predictors of improvement of renal function after TAVR. METHODS: The present work is an analysis of the Brazilian Registry of TAVR, a national non-randomized prospective study with 22 Brazilian centers. Patients with baseline renal dysfunction (estimated glomerular filtration rate [eGFR] < 60mL/min/1.73m2) were stratified according to renal function after TAVR: increase >10% in eGFR were classified as TAVR induced renal function improvement (TIRFI); decrease > 10% in eGFR were classified as acute kidney injury (AKI) and stable renal function (neither criteria). RESULTS: A total of 819 consecutive patients with symptomatic severe AS were included. Of these, baseline renal dysfunction (estimated glomerular filtration rate [eGFR] < 60mL/min/1.73m2) was present in 577 (70%) patients. Considering variance in renal function between baseline and at discharge after TAVR procedure, TIRFI was seen in 197 (34.1%) patients, AKI in 203 (35.2%), and stable renal function in 177 (30.7%). The independent predictors of TIRFI were: absence of coronary artery disease (OR: 0.69; 95% CI 0.48-0.98; P = 0.039) and lower baseline eGFR (OR: 0.98; 95% CI 0.97-1.00; P = 0.039). There was no significant difference in 30-day and 1-year all-cause mortality between patients with stable renal function or TIRFI. Nonetheless, individuals that had AKI after TAVR presented higher mortality compared with TIRFI and stable renal function groups (29.3% vs. 15.4% vs. 9.5%, respectively; p < 0.001). CONCLUSIONS: TIRFI was frequently found among baseline impaired renal function individuals but was not associated with improved 1-year outcomes.


Asunto(s)
Riñón/fisiología , Insuficiencia Renal Crónica/fisiopatología , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Femenino , Tasa de Filtración Glomerular/fisiología , Implantación de Prótesis de Válvulas Cardíacas/métodos , Hemodinámica/fisiología , Humanos , Pruebas de Función Renal/métodos , Modelos Logísticos , Masculino , Oportunidad Relativa , Pronóstico , Estudios Prospectivos , Insuficiencia Renal Crónica/complicaciones , Insuficiencia Renal Crónica/cirugía , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
9.
Rev Port Cardiol (Engl Ed) ; 40(2): 71-76, 2021 Feb.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-33402278

RESUMEN

INTRODUCTION AND OBJECTIVES: The Stents Coated With the Biodegradable Polymer on Their Abluminal Faces and Elution of Sirolimus Versus Biolimus Elution for the Treatment of de Novo Coronary Lesions - DESTINY Trial is a non-inferiority randomized study that compared the Inspiron™ sirolimus-eluting stent (SES) with the control Biomatrix™ Flex biolimus-eluting stent (BES). Previous reports in the first year showed similar outcomes for both stents, in clinical, angiographic, optical coherence tomography, and intravascular ultrasound assessments. The present analysis aims to compare the clinical performance of these two biodegradable polymer drug-eluting stents five years after the index procedure. METHODS: A total of 170 patients (194 lesions) were randomized in a 2:1 ratio for treatment with SES or BES, respectively. The primary endpoint for the present study was the five-year rate of combined major adverse cardiac events, defined as cardiac death, myocardial infarction, or target lesion revascularization. RESULTS: At five years, the primary endpoint occurred in 12.5% and 17.9% of the SES and BES groups, respectively (p=0.4). There was no definite or probable stent thrombosis among patients treated with the novel SES stent during the five years of follow-up, and no stent thrombosis after the first year in the BES group. CONCLUSIONS: The novel Inspiron™ stent had similar good clinical performance in long-term follow-up when compared head-to-head with the control latest-generation Biomatrix™ Flex biolimus-eluting stent.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Implantes Absorbibles , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Polímeros , Diseño de Prótesis , Resultado del Tratamiento
10.
Int. j. cardiovasc. sci. (Impr.) ; 33(5): 537-549, Sept.-Oct. 2020. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1134402

RESUMEN

Abstract Aortic stenosis is an insidious disease of rapid progression after the onset of symptoms. Aortic valve replacement surgery is a well-established therapy that reduces symptoms and increases survival rates. However, the procedure may be associated with high operative mortality rates and promote comorbidity. Depending on the local reality, the prevalence of patients considered inoperable (due to medical comorbidities and age) may achieve 30%. For these patients, transcatheter aortic valve implantation (TAVI) was initially indicated; over time, the method has advanced technologically and been simplified, and become an alternative therapy for patients at low and intermediate surgical risk also, and considered one of the major advances of modern medicine.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/estadística & datos numéricos , Válvula Aórtica , Estenosis de la Válvula Aórtica/epidemiología , Complicaciones Posoperatorias , Prevalencia , Tasa de Supervivencia , Fibrinolíticos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Complicaciones Intraoperatorias
12.
Circ Cardiovasc Interv ; 12(3): e007546, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30871358

RESUMEN

BACKGROUND: Stroke remains one of the most devastating complications of transcatheter aortic valve implantation (TAVI). The aim of this study was to identify the incidence, timing, temporal trends, and predictors of stroke after TAVI and evaluate the outcomes of patients with stroke. METHODS AND RESULTS: The CENTER-Collaboration is an international collaboration consisting of 3 national registries and 7 local registries or prospective clinical trials, selected through a systematic review. Accordingly, a total of 10 982 patients undergoing transfemoral TAVI between 2007 and 2018 were included in the current patient-level pooled analyses. A total of 261 patients (2.4%) experienced stroke during the first month after TAVI. The median time between TAVI and stroke was 1 day (interquartile range, 0-6 days). The stroke rate was comparable in procedures performed in the early years of TAVI (2007-2012) to those in the more recent years of TAVI (2013-2018; both 2.4%; P=1.0). Independent predictors of stroke at 30 days were a history of cerebrovascular events (odds ratio, 2.2; 95% CI, 1.4-3.6; P=0.0012) and a glomerular filtration rate of <30 mL/min per 1.73 m2 (odds ratio, 1.7; 95% CI, 1.0-2.8; P=0.05). Stroke occurring within the first 30 days after TAVI was associated with a 6-fold increase of 30-day mortality (odds ratio, 6.0; 95% CI, 4.4-8.1; P<0.001). Moreover, patients with stroke more frequently had documented new-onset atrial fibrillation (16% versus 3%; P<0.001) and major or life-threatening bleedings (12% versus 7%; P=0.002) at 30-day follow-up. CONCLUSIONS: In this large, global, patient-level analysis, the incidence of stroke after transfemoral TAVI was 2.4%. Prior cerebrovascular events and a low glomerular filtration rate independently predicted the occurrence of stroke after TAVI. The occurrence of stroke after TAVI was associated with a strikingly 6-fold increase of 30-day mortality; additionally, there was a 5-fold higher rate of new-onset atrial fibrillation in patients with stroke. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT03588247.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Cateterismo Periférico/efectos adversos , Arteria Femoral , Accidente Cerebrovascular/epidemiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Cateterismo Periférico/mortalidad , Ensayos Clínicos como Asunto , Femenino , Humanos , Incidencia , Masculino , Punciones , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/mortalidad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
13.
Rev Esp Cardiol (Engl Ed) ; 72(1): 21-29, 2019 Jan.
Artículo en Inglés, Español | MEDLINE | ID: mdl-29358043

RESUMEN

INTRODUCTION AND OBJECTIVES: Acute kidney injury (AKI) is frequently observed after transcatheter aortic valve implantation (TAVI) and is associated with higher mortality. However, the impact of AKI on long-term outcomes remains controversial. Therefore, we sought to evaluate the impact of AKI on short- and long-term outcomes following TAVI using the Valve Academic Research Consortium 2 criteria. METHODS: Consecutive patients (n = 794) with severe aortic stenosis who underwent TAVI were included in a multicenter Brazilian registry. Logistic regression analysis was used to identify predictors of AKI. Four-year outcomes were determined as Kaplan-Meier survival curves, and an adjusted landmark analysis was used to test the impact of AKI on mortality among survivors at 12 months. RESULTS: The incidence of AKI after TAVI was 18%. Independent predictors of AKI were age, diabetes mellitus, major or life-threatening bleeding and valve malpositioning. Acute kidney injury was independently associated with higher risk of all-cause death (adjusted HR, 2.8; 95%CI, 2.0-3.9; P < .001) and cardiovascular mortality (adjusted HR, 2.9; 95%CI, 1.9-4.4; P < .001) over the entire follow-up period. However, when considering only survivors at 12 months, there was no difference in both clinical endpoints (adjusted HR, 1.2; 95%CI, 0.5-2.4; P = .71, and HR, 0.7; 95%CI, 0.2-2.1; P = .57, respectively). CONCLUSIONS: Acute kidney injury is a frequent complication after TAVI. Older age, diabetes, major or life-threatening bleeding, and valve malpositioning were independent predictors of AKI. Acute kidney injury is associated with worse short- and long-term outcomes. However, the major impact of AKI on mortality is limited to the first year after TAVI.


Asunto(s)
Lesión Renal Aguda/epidemiología , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Lesión Renal Aguda/etiología , Anciano de 80 o más Años , Brasil/epidemiología , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Pronóstico , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo
14.
Circ Cardiovasc Interv ; 11(11): e006927, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30571207

RESUMEN

BACKGROUND: The impact of preexisting left bundle branch block (LBBB) in transcatheter aortic valve replacement (TAVR) recipients is unknown. The aim of this study was to determine the impact of preexisting LBBB on clinical outcomes after TAVR. METHODS AND RESULTS: This multicenter study evaluated 3404 TAVR candidates according to the presence or absence of LBBB on baseline ECG. TAVR complications and causes of death were defined according to Valve Academic Research Consortium-2 definitions. Follow-up outpatient visits or telephone interviews were conducted at 30 days, 12 months, and yearly thereafter. Echocardiography examinations were performed at baseline, at hospital discharge, and at 1-year follow-up. Preexisting LBBB was present in 398 patients (11.7%) and was associated with an increased risk of permanent pacemaker implantation (PPI; 21.1% versus 14.8%; adjusted odds ratio, 1.51; 95% CI, 1.12-2.04) but not death (7.3% versus 5.5%; adjusted odds ratio, 1.33; 95% CI, 0.84-2.12) at 30 days. At a mean follow-up of 22±21 months, there were no differences between patients with and without preexisting LBBB in overall mortality (adjusted hazard ratio, 0.94; 95% CI, 0.75-1.18) and cardiovascular mortality (adjusted hazard ratio, 0.90; 95% CI, 0.68-1.21). In a subanalysis of 2421 patients without PPI at 30 days and with complete follow-up about the PPI, preexisting LBBB was not associated with an increased risk of PPI or sudden cardiac death. Patients with preexisting LBBB had a lower left ventricular ejection fraction (LVEF) at baseline and at 1-year follow-up ( P <0.001 for both), but those with low LVEF exhibited a similar increase in LVEF over time after TAVR compared with patients with no preexisting LBBB ( P=0.327). CONCLUSIONS: Preexisting LBBB significantly increased the risk of early (but not late) PPI after TAVR, without any significant effect on overall mortality or cardiovascular mortality. Preexisting LBBB was associated with lower LVEF pre-TAVR but did not prevent an increase in LVEF post-TAVR similar to patients without LBBB.


Asunto(s)
Válvula Aórtica/cirugía , Bloqueo de Rama/terapia , Estimulación Cardíaca Artificial , Enfermedades de las Válvulas Cardíacas/cirugía , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Brasil/epidemiología , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/mortalidad , Bloqueo de Rama/fisiopatología , Canadá/epidemiología , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/mortalidad , Ecocardiografía , Electrocardiografía , Europa (Continente)/epidemiología , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/mortalidad , Enfermedades de las Válvulas Cardíacas/fisiopatología , Humanos , Masculino , Marcapaso Artificial , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/terapia , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
15.
Arq Bras Cardiol ; 111(2): 193-202, 2018 Aug.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-30183986

RESUMEN

BACKGROUND: Balloon post-dilatation (BPD) is often needed for optimizing transcatheter heart valve (THV) implantation, since paravalvular leak (PVL) after transcatheter aortic valve implantation is associated with poor outcome and mortality. Quantitative assessment of PVL severity before and after BPD is mandatory to properly assess PVL, thus improving implantation results and outcomes. OBJECTIVE: To investigate a quantitative angiographic assessment of aortic regurgitation (AR) by videodensitometry before and after BPD. METHODS: Videodensitometric-AR assessments (VD-AR) before and after BPD were analysed in 61 cases. RESULTS: VD-AR decreased significantly from 24.0[18.0-30.5]% to 12.0[5.5-19.0]% (p < 0.001, a two-tailed p < 0.05 defined the statistical significance). The relative delta of VD-AR after BPD ranged from -100% (improvement) to +40% (deterioration) and its median value was -46.2%. The frequency of improvement, no change, and deterioration were 70% (n = 43), 25% (n = 15) and 5% (n = 3), respectively. Significant AR (VD-AR > 17%) was observed in 47 patients (77%) before and in 19 patients (31%) after BPD. CONCLUSIONS: VD-AR after THV implantation provides a quantitative assessment of post-TAVI regurgitation and can help in the decision-making process on performing BPD and in determining its efficacy.


Asunto(s)
Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano de 80 o más Años , Aortografía , Densitometría , Femenino , Humanos , Masculino , Complicaciones Posoperatorias/diagnóstico por imagen , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Grabación en Video
16.
Arq. bras. cardiol ; 111(2): 193-202, Aug. 2018. tab, graf
Artículo en Inglés, Portugués | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-950218

RESUMEN

Abstract Background: Balloon post-dilatation (BPD) is often needed for optimizing transcatheter heart valve (THV) implantation, since paravalvular leak (PVL) after transcatheter aortic valve implantation is associated with poor outcome and mortality. Quantitative assessment of PVL severity before and after BPD is mandatory to properly assess PVL, thus improving implantation results and outcomes. Objective: To investigate a quantitative angiographic assessment of aortic regurgitation (AR) by videodensitometry before and after BPD. Methods: Videodensitometric-AR assessments (VD-AR) before and after BPD were analysed in 61 cases. Results: VD-AR decreased significantly from 24.0[18.0-30.5]% to 12.0[5.5-19.0]% (p < 0.001, a two-tailed p < 0.05 defined the statistical significance). The relative delta of VD-AR after BPD ranged from -100% (improvement) to +40% (deterioration) and its median value was -46.2%. The frequency of improvement, no change, and deterioration were 70% (n = 43), 25% (n = 15) and 5% (n = 3), respectively. Significant AR (VD-AR > 17%) was observed in 47 patients (77%) before and in 19 patients (31%) after BPD. Conclusions: VD-AR after THV implantation provides a quantitative assessment of post-TAVI regurgitation and can help in the decision-making process on performing BPD and in determining its efficacy.


Resumo Fundamento: A pós-dilatação com balão (PDB) é normalmente necessária para otimização do implante da válvula cardíaca transcateter (THV), uma vez que o "escape" ou leak paravalvar (PVL) após implante de valva aórtica transcateter está associada com desfecho ruim e mortalidade. A avaliação quantitativa da gravidade do PVL antes e após a PDB é mandatória para se avaliar adequadamente o PVL e, assim, melhorar os resultados e os desfechos do implante. Objetivo: Investigar uma avalição angiográfica quantitativa da regurgitação aórtica (RA) por videodensitometria (VD-RA) antes e após a PDB. Métodos: Resultados da VD-RA antes e após a PDB foram analisados em 61 casos. Resultados Houve diminuição significativa da VD-RA de 24,0(18,0-30,5)% para 12,0(5,5-19,0)% (p < 0,001; p < 0,05 bilateral foi definido como significância estatística). O delta relativo de VD-RA após a PDB variou de -100% (melhora) a +40% (piora) e o valor mediano foi -46,2%. As frequências de melhora, ausência de mudança, e piora foram 70% (n = 43), 25% (n = 15) e 5% (n = 3), respectivamente. Observou-se RA significativo (VD-RA > 17%) em 47 pacientes (77%) antes e em 19 pacientes (31%) após a PDB. Conclusões: A VD-RA após o implante de THV possibilita a avaliação quantitativa da regurgitação pós-TAVI, e pode auxiliar na tomada de decisão quanto à realização ou não da PDB, bem como na avaliação de sua eficácia.


Asunto(s)
Humanos , Masculino , Femenino , Anciano de 80 o más Años , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Reemplazo de la Válvula Aórtica Transcatéter , Complicaciones Posoperatorias/diagnóstico por imagen , Grabación en Video , Índice de Severidad de la Enfermedad , Aortografía , Densitometría , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
17.
Catheter Cardiovasc Interv ; 92(5): 945-953, 2018 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-29520970

RESUMEN

OBJECTIVES: To explore the rate, the determinants of success, and the hemodynamic impact of balloon postdilatation (BPD) of self-expanding transcatheter heart valves (SE-THVs) BACKGROUND: BPD is commonly used to optimize valve expansion and reduce paravalvular leakage (PVL) after transcatheter aortic valve implantation (TAVI) without clearly knowing its hemodynamic benefits. METHODS: Patients (n = 307) who received a SE-THV were stratified according to whether a BPD was performed or not. Patients who received BPD were stratified according to the severity of PVL remaining after BPD into two groups: Successful BPD (≤mild PVL + BPD) and Failed BPD (moderate-severe PVL + BPD). RESULTS: BPD was performed in 121 patients (39.4%) and was successful in 106 patients (87.6% of attempts). A ratio of the postdilatation balloon diameter to the annulus diameter ≤0.95 was an independent predictor of BPD failure (OR: 10.72 [2.02-56.76], P = .005). Peak transvalvular pressure gradient (PG) was lower in the Successful BPD group (14[12-22] mm Hg) than in the Failed BPD group (18[16-23] mm Hg, P = .029), and did not rise in either group during follow-up (median [IQR], 364[161-739] days). CONCLUSION: BPD was performed in 39% of patients who received a SE-THV, and was successful in the majority of attempts. BPD failure was more likely in patients with a small postdilatation balloon-to-annulus diameter ratio. Effective BPD improved THV hemodynamic performance, and this was maintained in the intermediate-term post-TAVI.


Asunto(s)
Insuficiencia de la Válvula Aórtica/prevención & control , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Valvuloplastia con Balón , Prótesis Valvulares Cardíacas , Hemodinámica , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/fisiopatología , Valvuloplastia con Balón/efectos adversos , Brasil , Femenino , Humanos , Masculino , Diseño de Prótesis , Recuperación de la Función , Sistema de Registros , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
18.
Rev. Soc. Cardiol. Estado de Säo Paulo ; 28(1): 47-53, jan.-mar. 2018. graf
Artículo en Inglés, Portugués | LILACS | ID: biblio-906727

RESUMEN

Por cerca de 15 anos, o Implante Transcateter Valvar Aórtico (TAVI) passou por avanços tecnológicos, adquiriu experiência acumulada e tornou-se alternativa à cirurgia convencional. A principal indicação é a estenose aórtica degenerativa do idoso. Evidências atuais foram ampliadas para aqueles de risco intermediário e se tornaram mais robustas nos pacientes de alto risco e inoperáveis. Em situações específicas, como valva aórtica bicúspide, regurgitação aórtica pura, pacientes de baixo risco e bioprótese cirúrgica degenerada, os resultados ainda não são totalmente previsíveis, mas muito promissores. Os tipos de dispositivos atualmente liberados para uso clinico são divididos em: da geração inicial e os da nova geração, assim como em auto expansível, balão expansível e expansível mecanicamente. O sítio de acesso preferencial na atualidade é a via transfemoral. Outras alternativas de acessos também têm se mostrado viáveis e confiáveis. As principais complicações são vasculares, eventos neurológicos, distúrbios de condução e regurgitação paravalvar. Apesar da baixa incidência, a ruptura aórtica e a oclusão coronária são uma fonte de maior interesse, devido ao seu potencial impacto na morbimortalidade. A realização mais recente do procedimento em pacientes mais jovens faz necessária mais atenção à questões referentes à durabilidade e ao risco de trombose. Embora o TAVI ainda possa ser um procedimento complexo, após atingida experiência, existe a tendência de migração para uma abordagem mais simplificada com segurança. A seleção do paciente deve, idealmente, ser feita por uma equipe multidisciplinar e uma completa avaliação por imagem, em que a angitomografia é imprescindível, mandatória


For around fifteen years, Transcatheter Aortic Valve Implant (TAVI) has undergone technological advances, acquired accumulated experience, and become an alternative to conventional surgery. The main indication is degenerative aortic stenosis in the elderly patient. Current evidence has been extended to those with intermediate risk, and has become more robust in high-risk and inoperable patients. In specific situations, such as bicuspid aortic valve, pure aortic regurgitation, low-risk patients, and degenerated surgical bioprosthesis, the results are not totally predictable, but are very promising. The types of device currently released for clinical use are divided into first generation and new generation devices, and into auto-expandable, balloon-expandable, and mechanically-expandable. The preferential access site is currently the transfermoral route. Other access alternatives have also proven viable and reliable. The main complications are vascular, neurological events, conduction disturbances, and paravalvular regurgitation. Despite their low incidence, aortic rupture and coronary occlusion have attracted greater interest due to their potential impact on morbimortality. The more recent use of the procedure in younger patients raises issues related to durability and the risk of thrombosis. Although TAVI is still a complex procedure, after gaining experience, there is a tendency to move towards a more simplified, safer approach. The patient selection should ideally be carried out by a multidisciplinary team, and a complete imaging assessment that includes angiotomography is absolutely essential


Asunto(s)
Humanos , Masculino , Femenino , Válvula Aórtica/anomalías , Implantación de Prótesis , Enfermedades de las Válvulas Cardíacas , Válvula Mitral/anomalías , Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Marcapaso Artificial , Bioprótesis , Ecocardiografía/métodos , Tomografía/métodos , Factores de Riesgo , Bloqueo Atrioventricular
19.
JACC Cardiovasc Interv ; 10(15): 1564-1574, 2017 08 14.
Artículo en Inglés | MEDLINE | ID: mdl-28734885

RESUMEN

OBJECTIVES: This study sought to assess the influence of baseline right bundle branch block (RBBB) on all-cause and cardiovascular mortality as well as sudden cardiac death (SCD) among patients undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: Few data exist regarding the late clinical impact of pre-existing RBBB in TAVR recipients. METHODS: A total of 3,527 patients (mean age 82 ± 8 years, 50.1% men) were evaluated according to the presence of RBBB on baseline electrocardiography. Intraventricular conduction abnormalities were classified according to the American Heart Association, American College of Cardiology Foundation, and Heart Rhythm Society recommendations for standardization and interpretation of the electrocardiogram. TAVR complications and causes of death were defined according to Valve Academic Research Consortium 2 definitions. RESULTS: RBBB was present on baseline electrocardiography in 362 patients (10.3%) and associated with higher 30-day rates of permanent pacemaker implantation (PPI) (40.1% vs. 13.5%; p < 0.001) and death (10.2% vs. 6.9%; p = 0.024). At a mean follow-up of 20 ± 18 months, pre-existing RBBB was independently associated with all-cause mortality (hazard ratio [HR]: 1.31; 95% confidence interval [CI]: 1.06 to 1.63; p = 0.014) and cardiovascular mortality (HR: 1.45; 95% CI: 1.11 to 1.89; p = 0.006) but not with SCD (HR: 0.71; 95% CI: 0.22 to 2.32; p = 0.57). Patients with pre-existing RBBB and without PPI at discharge from the index hospitalization had the highest 2-year risk for cardiovascular death (27.8%; 95% CI: 20.9% to 36.1%; log-rank p = 0.007). In a subanalysis of 1,245 patients without PPI at discharge from the index hospitalization and with complete follow-up regarding the need for PPI, pre-existing RBBB was independently associated with the composite of SCD and PPI (HR: 2.68; 95% CI: 1.16 to 6.17; p = 0.023). CONCLUSIONS: Pre-existing RBBB was found in 10% of TAVR recipients and was associated with poorer clinical outcomes. Patients with baseline RBBB without permanent pacemakers at hospital discharge may be at especially high risk for high-degree atrioventricular block and/or SCD during follow-up. Future studies should evaluate strategies aimed at the early detection of patients at risk for late development of high-degree atrioventricular block.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bloqueo de Rama/mortalidad , Muerte Súbita Cardíaca/epidemiología , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Brasil/epidemiología , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/fisiopatología , Canadá/epidemiología , Causas de Muerte , Ecocardiografía , Electrocardiografía , Europa (Continente)/epidemiología , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Análisis Multivariante , Modelos de Riesgos Proporcionales , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
20.
EuroIntervention ; 13(10): 1157-1165, 2017 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-28691910

RESUMEN

AIMS: In addition to patients with pure/predominant aortic stenosis (PAS), real-world transcatheter aortic valve implantation (TAVI) referrals include patients with mixed aortic valve disease (MAVD; severe stenosis+moderate-severe regurgitation). We sought to compare TAVI outcomes in patients with MAVD vs. PAS. METHODS AND RESULTS: Out of 793 consecutive patients undergoing TAVI, 106 (13.4%) had MAVD. Patients with MAVD were younger and had a higher operative risk, a more severe adverse cardiac remodelling, and a worse functional status than patients with PAS. Moderate-severe prosthetic valve regurgitation (PVR) was significantly more frequent in patients with MAVD than in patients with PAS (15.7% vs. 3.6%, p=0.003), even after propensity-score and multivariable adjustments. Moderate-severe PVR was associated with increased one-year mortality in patients with PAS (log-rank p=0.002), but not in patients with MAVD (log-rank p=0.27). Eventually, all-cause and cardiac mortality as well as the functional capacity were similar in the two study groups up to one year. CONCLUSIONS: A significant proportion of patients referred for TAVI in a real-world registry has MAVD. Moderate-severe AR at baseline can influence the rate and modify the clinical sequelae of post-TAVI PVR. Eventually, clinical outcomes in patients with MAVD are comparable to those in patients with PAS in the acute and midterm phases, in spite of a baseline higher risk. MAVD should not be considered a contraindication for TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Cardiopatías Congénitas/cirugía , Enfermedades de las Válvulas Cardíacas/cirugía , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Enfermedad de la Válvula Aórtica Bicúspide , Cateterismo Cardíaco/métodos , Femenino , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Masculino , Persona de Mediana Edad , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA