RESUMEN
The European Council Directive 2013/59/Euratom (BSS Directive) includes optimisation of treatment with radiotherapeutic procedures based on patient dosimetry and verification of the absorbed doses delivered. The present policy statement summarises aspects of three directives relating to the therapeutic use of radiopharmaceuticals and medical devices, and outlines the steps needed for implementation of patient dosimetry for radioactive drugs. To support the transition from administrations of fixed activities to personalised treatments based on patient-specific dosimetry, EFOMP presents a number of recommendations including: increased networking between centres and disciplines to support data collection and development of codes-of-practice; resourcing to support an infrastructure that permits routine patient dosimetry; research funding to support investigation into individualised treatments; inter-disciplinary training and education programmes; and support for investigator led clinical trials. Close collaborations between the medical physicist and responsible practitioner are encouraged to develop a similar pathway as is routine for external beam radiotherapy and brachytherapy. EFOMP's policy is to promote the roles and responsibilities of medical physics throughout Europe in the development of molecular radiotherapy to ensure patient benefit. As the BSS directive is adopted throughout Europe, unprecedented opportunities arise to develop informed treatments that will mitigate the risks of under- or over-treatments.
Asunto(s)
Medicina Nuclear , Humanos , Radiometría , Políticas , Europa (Continente)RESUMEN
PREAMBLE: The Society of Nuclear Medicine and Molecular Imaging (SNMMI) is an international scientific and professional organization founded in 1954 to promote the science, technology, and practical application of nuclear medicine. The European Association of Nuclear Medicine (EANM) is a professional non-profit medical association that facilitates communication worldwide between individuals pursuing clinical and research excellence in nuclear medicine. The EANM was founded in 1985. The merged International Society for Magnetic Resonance in Medicine (ISMRM) is an international, nonprofit, scientific association whose purpose is to promote communication, research, development, and applications in the field of magnetic resonance in medicine and biology and other related topics and to develop and provide channels and facilities for continuing education in the field.The ISMRM was founded in 1994 through the merger of the Society of Magnetic Resonance in Medicine and the Society of Magnetic Resonance Imaging. SNMMI, ISMRM, and EANM members are physicians, technologists, and scientists specializing in the research and practice of nuclear medicine and/or magnetic resonance imaging. The SNMMI, ISMRM, and EANM will periodically define new guidelines for nuclear medicine practice to help advance the science of nuclear medicine and/or magnetic resonance imaging and to improve the quality of service to patients throughout the world. Existing practice guidelines will be reviewed for revision or renewal, as appropriate, on their fifth anniversary or sooner, if indicated. Each practice guideline, representing a policy statement by the SNMMI/EANM/ISMRM, has undergone a thorough consensus process in which it has been subjected to extensive review. The SNMMI, ISMRM, and EANM recognize that the safe and effective use of diagnostic nuclear medicine imaging and magnetic resonance imaging requires specific training, skills, and techniques, as described in each document. Reproduction or modification of the published practice guideline by those entities not providing these services is not authorized. These guidelines are an educational tool designed to assist practitioners in providing appropriate care for patients. They are not inflexible rules or requirements of practice and are not intended, nor should they be used, to establish a legal standard of care. For these reasons and those set forth below, the SNMMI, the ISMRM, and the EANM caution against the use of these guidelines in litigation in which the clinical decisions of a practitioner are called into question. The ultimate judgment regarding the propriety of any specific procedure or course of action must be made by the physician or medical physicist in light of all the circumstances presented. Thus, there is no implication that an approach differing from the guidelines, standing alone, is below the standard of care. To the contrary, a conscientious practitioner may responsibly adopt a course of action different from that set forth in the guidelines when, in the reasonable judgment of the practitioner, such course of action is indicated by the condition of the patient, limitations of available resources, or advances in knowledge or technology subsequent to publication of the guidelines. The practice of medicine includes both the art and the science of the prevention, diagnosis, alleviation, and treatment of disease. The variety and complexity of human conditions make it impossible to always reach the most appropriate diagnosis or to predict with certainty a particular response to treatment. Therefore, it should be recognized that adherence to these guidelines will not ensure an accurate diagnosis or a successful outcome. All that should be expected is that the practitioner will follow a reasonable course of action based on current knowledge, available resources, and the needs of the patient to deliver effective and safe medical care. The sole purpose of these guidelines is to assist practitioners in achieving this objective.
RESUMEN
This article presents the protocol on Quality Controls in PET/CT and PET/MRI published online in May 2022 by the European Federation of Organisations for Medical Physics (EFOMP), which was developed by the Working group for PET/CT and PET/MRI Quality Control (QC) protocol. The main objective of this protocol was to comprehensively provide simple and practical procedures that may be integrated into clinical practice to identify changes in the PET/CT/MRI system's performance and avoid short- and long-term quality deterioration. The protocol describes the quality control procedures on radionuclide calibrators, weighing scales, PET, CT and MRI systems using selected and measurable parameters that are directly linked to clinical images quality. It helps to detect problems before they can impact clinical studies in terms of safety, image quality, quantification accuracy and patient radiation dose. CT and MRI QCs are described only in the context of their use for PET (attenuation correction and anatomical localization) imaging. Detailed step-by-step instructions have been provided, limiting any misinterpretations or interpersonal variations as much as possible. This paper presents the main characteristics of the protocol illustrated together with a brief summary of the content of each chapter. A regular QC based on the proposed protocol would guarantee that PET/CT and PET/MRI systems operate under optimal conditions, resulting in the best performance for routine clinical tasks.
Asunto(s)
Imagen Multimodal , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Imagen Multimodal/métodos , Tomografía de Emisión de Positrones/métodos , Imagen por Resonancia Magnética/métodos , Control de Calidad , Procesamiento de Imagen Asistido por Computador/métodosRESUMEN
We present guidelines by the European Association of Nuclear Medicine (EANM) for routine quality control (QC) of PET-CT and PET-MR systems. These guidelines are partially based on the current EANM guidelines for routine quality control of Nuclear Medicine instrumentation but focus more on the inherent multimodal aspect of the current, state-of-the-art PET-CT and PET-MR scanners. We briefly discuss the regulatory context put forward by the International Electrotechnical Commission (IEC) and European Commission (EC) and consider relevant guidelines and recommendations by other societies and professional organizations. As such, a comprehensive overview of recommended quality control procedures is provided to ensure the optimal operational status of a PET system, integrated with either a CT or MR system. In doing so, we also discuss the rationale of the different tests, advice on the frequency of each test and present the relevant MR and CT tests for an integrated system. In addition, we recommend a scheme of preventive actions to avoid QC tests from drifting out of the predefined range of acceptable performance values such that an optimal performance of the PET system is maintained for routine clinical use.
Asunto(s)
Medicina Nuclear , Tomografía Computarizada por Tomografía de Emisión de Positrones , Tomografía de Emisión de Positrones/métodos , Control de Calidad , Fantasmas de ImagenRESUMEN
The cerebral expression of the A2A adenosine receptor (A2AAR) is altered in neurodegenerative diseases such as Parkinson's (PD) and Huntington's (HD) diseases, making these receptors an attractive diagnostic and therapeutic target. We aimed to further investigate the pharmacokinetic properties in the brain of our recently developed A2AAR-specific antagonist radiotracer [18F]FLUDA. For this purpose, we retrospectively analysed dynamic PET studies of healthy mice and rotenone-treated mice, and conducted dynamic PET studies with healthy pigs. We performed analysis of mouse brain time-activity curves to calculate the mean residence time (MRT) by non-compartmental analysis, and the binding potential (BPND) of [18F]FLUDA using the simplified reference tissue model (SRTM). For the pig studies, we performed a Logan graphical analysis to calculate the radiotracer distribution volume (VT) at baseline and under blocking conditions with tozadenant. The MRT of [18F]FLUDA in the striatum of mice was decreased by 30% after treatment with the A2AAR antagonist istradefylline. Mouse results showed the highest BPND (3.9 to 5.9) in the striatum. SRTM analysis showed a 20% lower A2AAR availability in the rotenone-treated mice compared to the control-aged group. Tozadenant treatment significantly decreased the VT (14.6 vs. 8.5 mL · g-1) and BPND values (1.3 vs. 0.3) in pig striatum. This study confirms the target specificity and a high BPND of [18F]FLUDA in the striatum. We conclude that [18F]FLUDA is a suitable tool for the non-invasive quantitation of altered A2AAR expression in neurodegenerative diseases such as PD and HD, by PET.
RESUMEN
BACKGROUND: Due to comparatively long measurement times in simultaneous positron emission tomography and magnetic resonance (PET/MR) imaging, patient movement during the measurement can be challenging. This leads to artifacts which have a negative impact on the visual assessment and quantitative validity of the image data and, in the worst case, can lead to misinterpretations. Simultaneous PET/MR systems allow the MR-based registration of movements and enable correction of the PET data. To assess the effectiveness of motion correction methods, it is necessary to carry out measurements on phantoms that are moved in a reproducible way. This study explores the possibility of using such a phantom-based setup to evaluate motion correction strategies in PET/MR of the human head. METHOD: An MR-compatible robotic system was used to generate rigid movements of a head-like phantom. Different tools, either from the manufacturer or open-source software, were used to estimate and correct for motion based on the PET data itself (SIRF with SPM and NiftyReg) and MR data acquired simultaneously (e.g. MCLFIRT, BrainCompass). Different motion estimates were compared using data acquired during robot-induced motion. The effectiveness of motion correction of PET data was evaluated by determining the segmented volume of an activity-filled flask inside the phantom. In addition, the segmented volume was used to determine the centre-of-mass and the change in maximum activity concentration. RESULTS: The results showed a volume increase between 2.7 and 36.3% could be induced by the experimental setup depending on the motion pattern. Both, BrainCompass and MCFLIRT, produced corrected PET images, by reducing the volume increase to 0.7-4.7% (BrainCompass) and to -2.8-0.4% (MCFLIRT). The same was observed for example for the centre-of-mass, where the results show that MCFLIRT (0.2-0.6 mm after motion correction) had a smaller deviation from the reference position than BrainCompass (0.5-1.8 mm) for all displacements. CONCLUSIONS: The experimental setup is suitable for the reproducible generation of movement patterns. Using open-source software for motion correction is a viable alternative to the vendor-provided motion-correction software.
RESUMEN
BACKGROUND: MR-based methods for attenuation correction (AC) in PET/MRI either neglect attenuation of bone, or use MR-signal derived information about bone, which leads to a bias in quantification of tracer uptake in PET. In a previous study, we presented a PET/MRI specific MR coil with an integrated transmission source (TX) system allowing for direct measurement of attenuation. In phantom measurements, this system successfully reproduced the linear attenuation coefficient of water. PURPOSE: The purpose of this study is to validate the TX system in a clinical setting using animals and to show its applicability compared to standard clinical methods. METHODS: As test subject, a 15-kg piglet was injected with 53 MBq of 18F-NaF. The µ-map obtained with the TX system and the reconstructed activity distribution were compared to four established AC methods: a Dixon sequence, an ultra-short echo time (UTE) sequence, a CT scan, and a 511 keV transmission scan using a Siemens ECAT EXACT HR+ as the reference. The PET/MRI measurements were performed on a Siemens Biograph mMR to obtain the µ-map using the TX system as well as the Dixon and UTE sequence directly followed by the CT and ECAT measurements. RESULTS: The reconstructed activity distribution using the TX system for AC showed similar results compared to the reference (<5% difference in hot regions) and outperformed the MR-based methods as implemented in the PET/MRI system (<10% difference in hot regions). However, the additional hardware of the TX system adds complexity to the acquisition process. CONCLUSION: Our porcine study demonstrates the feasibility of post-injection transmission scans using the developed TX system in a clinical setting. This makes it a useful tool for PET/MRI in cases where transmission information is needed for AC. Potential applications are studies using larger animals where state-of-the-art atlas-based or artificial intelligence AC methods are not available.
Asunto(s)
Inteligencia Artificial , Imagen Multimodal , Animales , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Imagen Multimodal/métodos , Fantasmas de Imagen , Tomografía de Emisión de Positrones/métodos , PorcinosRESUMEN
The expression of monocarboxylate transporters (MCTs) is linked to pathophysiological changes in diseases, including cancer, such that MCTs could potentially serve as diagnostic markers or therapeutic targets. We recently developed [18F]FACH as a radiotracer for non-invasive molecular imaging of MCTs by positron emission tomography (PET). The aim of this study was to evaluate further the specificity, metabolic stability, and pharmacokinetics of [18F]FACH in healthy mice and piglets. We measured the [18F]FACH plasma protein binding fractions in mice and piglets and the specific binding in cryosections of murine kidney and lung. The biodistribution of [18F]FACH was evaluated by tissue sampling ex vivo and by dynamic PET/MRI in vivo, with and without pre-treatment by the MCT inhibitor α-CCA-Na or the reference compound, FACH-Na. Additionally, we performed compartmental modelling of the PET signal in kidney cortex and liver. Saturation binding studies in kidney cortex cryosections indicated a KD of 118 ± 12 nM and Bmax of 6.0 pmol/mg wet weight. The specificity of [18F]FACH uptake in the kidney cortex was confirmed in vivo by reductions in AUC0-60min after pre-treatment with α-CCA-Na in mice (-47%) and in piglets (-66%). [18F]FACH was metabolically stable in mouse, but polar radio-metabolites were present in plasma and tissues of piglets. The [18F]FACH binding potential (BPND) in the kidney cortex was approximately 1.3 in mice. The MCT1 specificity of [18F]FACH uptake was confirmed by displacement studies in 4T1 cells. [18F]FACH has suitable properties for the detection of the MCTs in kidney, and thus has potential as a molecular imaging tool for MCT-related pathologies, which should next be assessed in relevant disease models.
Asunto(s)
Evaluación Preclínica de Medicamentos/métodos , Ácido Láctico/metabolismo , Transportadores de Ácidos Monocarboxílicos/metabolismo , Tomografía de Emisión de Positrones/métodos , Radiofármacos/farmacología , Animales , Línea Celular Tumoral , Femenino , Radioisótopos de Flúor/química , Vesícula Biliar/metabolismo , Riñón/metabolismo , Hígado/metabolismo , Ratones , Transportadores de Ácidos Monocarboxílicos/antagonistas & inhibidores , Ratas , PorcinosRESUMEN
PURPOSE: The adenosine A2A receptor has emerged as a therapeutic target for multiple diseases, and thus the non-invasive imaging of the expression or occupancy of the A2A receptor has potential to contribute to diagnosis and drug development. We aimed at the development of a metabolically stable A2A receptor radiotracer and report herein the preclinical evaluation of [18F]FLUDA, a deuterated isotopologue of [18F]FESCH. METHODS: [18F]FLUDA was synthesized by a two-step one-pot approach and evaluated in vitro by autoradiographic studies as well as in vivo by metabolism and dynamic PET/MRI studies in mice and piglets under baseline and blocking conditions. A single-dose toxicity study was performed in rats. RESULTS: [18F]FLUDA was obtained with a radiochemical yield of 19% and molar activities of 72-180 GBq/µmol. Autoradiography proved A2A receptor-specific accumulation of [18F]FLUDA in the striatum of a mouse and pig brain. In vivo evaluation in mice revealed improved stability of [18F]FLUDA compared to that of [18F]FESCH, resulting in the absence of brain-penetrant radiometabolites. Furthermore, the radiometabolites detected in piglets are expected to have a low tendency for brain penetration. PET/MRI studies confirmed high specific binding of [18F]FLUDA towards striatal A2A receptor with a maximum specific-to-non-specific binding ratio in mice of 8.3. The toxicity study revealed no adverse effects of FLUDA up to 30 µg/kg, ~ 4000-fold the dose applied in human PET studies using [18F]FLUDA. CONCLUSIONS: The new radiotracer [18F]FLUDA is suitable to detect the availability of the A2A receptor in the brain with high target specificity. It is regarded ready for human application.
Asunto(s)
Tomografía de Emisión de Positrones , Receptor de Adenosina A2A , Adenosina , Animales , Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Radioisótopos de Flúor , Ratones , Radiofármacos , Ratas , Receptor de Adenosina A2A/metabolismo , PorcinosRESUMEN
PURPOSE: Pridopidine is an investigational drug for Huntington disease (HD). Pridopidine was originally thought to act as a dopamine stabilizer. However, pridopidine shows highest affinity to the sigma-1 receptor (S1R) and enhances neuroprotection via the S1R in preclinical studies. Using [18F] fluspidine and [18F] fallypride PET, the purpose of this study was to assess in vivo target engagement/receptor occupancy of pridopidine to the S1R and dopamine D2/D3 receptor (D2/D3R) at clinical relevant doses in healthy volunteers (HVs) and as proof-of-concept in a small number of patients with HD. METHODS: Using [18F] fluspidine PET (300 MBq, 0-90 min), 11 male HVs (pridopidine 0.5 to 90 mg; six dose groups) and three male patients with HD (pridopidine 90 mg) were investigated twice, without and 2 h after single dose of pridopidine. Using [18F] fallypride PET (200 MBq, 0-210 min), four male HVs were studied without and 2 h following pridopidine administration (90 mg). Receptor occupancy was analyzed by the Lassen plot. RESULTS: S1R occupancy as function of pridopidine dose (or plasma concentration) in HVs could be described by a three-parameter Hill equation with a Hill coefficient larger than one. A high degree of S1R occupancy (87% to 91%) was found throughout the brain at pridopidine doses ranging from 22.5 to 90 mg. S1R occupancy was 43% at 1 mg pridopidine. In contrast, at 90 mg pridopidine, the D2/D3R occupancy was only minimal (~ 3%). CONCLUSIONS: Our PET findings indicate that at clinically relevant single dose of 90 mg, pridopidine acts as a selective S1R ligand showing near to complete S1R occupancy with negligible occupancy of the D2/D3R. The dose S1R occupancy relationship suggests cooperative binding of pridopidine to the S1R. Our findings provide significant clarification about pridopidine's mechanism of action and support further use of the 45-mg twice-daily dose to achieve full and selective targeting of the S1R in future clinical trials of neurodegenerative disorders. Clinical Trials.gov Identifier: NCT03019289 January 12, 2017; EUDRA-CT-Nr. 2016-001757-41.
Asunto(s)
Dopamina , Enfermedad de Huntington , Benzamidas , Benzofuranos , Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Voluntarios Sanos , Humanos , Enfermedad de Huntington/diagnóstico por imagen , Masculino , Piperidinas , Tomografía de Emisión de Positrones , Receptores de Dopamina D2/metabolismo , Receptores de Dopamina D3/metabolismoRESUMEN
PURPOSES: We present the first in-human brain PET imaging data of the new α4ß2 nicotinic acetylcholine receptor (nAChR)-targeting radioligand (+)-[18F]Flubatine. Aims were to develop a kinetic modeling-based approach to quantify (+)-[18F]Flubatine and compare the data of healthy controls (HCs) and patients with Alzheimer's disease (AD); to investigate the partial volume effect (PVE) on regional (+)-[18F]Flubatine binding; and whether (+)-[18F]Flubatine binding and cognitive test data respective ß-amyloid radiotracer accumulation were correlated. METHODS: We examined 11 HCs and 9 mild AD patients. All subjects underwent neuropsychological testing and [11C]PiB PET/MRI examination. (+)-[18F]Flubatine PET data were evaluated using full kinetic modeling and regional as well as voxel-based analyses. RESULTS: With 270-min p.i., the unchanged parent compound amounted to 97 ± 2%. Adequate fits of the time-activity curves were obtained with the 1 tissue compartment model (1TCM). (+)-[18F]Flubatine distribution volume (binding) was significantly reduced in bilateral mesial temporal cortex in AD patients compared with HCs (right 10.6 ± 1.1 vs 11.6 ± 1.4, p = 0.049; left 11.0 ± 1.1 vs 12.2 ± 1.8, p = 0.046; one-sided t tests each). PVE correction increased not only (+)-[18F]Flubatine binding of approximately 15% but also standard deviation of 0.4-70%. Cognitive test data and (+)-[18F]Flubatine binding were significantly correlated in the left anterior cingulate, right posterior cingulate, and right parietal cortex (r > 0.5, p < 0.05 each). In AD patients, (+)-[18F]Flubatine binding and [11C]PiB standardized uptake value ratios were negatively correlated in several regions; whereas in HCs, a positive correlation between cortical (+)-[18F]Flubatine binding and [11C]PiB accumulation in the white matter was found. No adverse event related to (+)-[18F]Flubatine occurred. CONCLUSION: (+)-[18F]Flubatine is a safe and stable PET ligand. Full kinetic modeling can be realized by 1TCM without metabolite correction. (+)-[18F]Flubatine binding affinity was high enough to detect group differences. Of interest, correlation between white matter ß-amyloid PET uptake and (+)-[18F]Flubatine binding indicated an association between white matter integrity and availability of α4ß2 nAChRs. Overall, (+)-[18F]Flubatine showed favorable characteristics and has therefore the potential to serve as α4ß2 nAChR-targeting PET ligand in further clinical trials.
Asunto(s)
Enfermedad de Alzheimer , Enfermedad de Alzheimer/diagnóstico por imagen , Péptidos beta-Amiloides , Compuestos de Anilina , Benzamidas , Encéfalo/diagnóstico por imagen , Compuestos Bicíclicos Heterocíclicos con Puentes , Humanos , Ligandos , Neuroimagen , Tomografía de Emisión de Positrones , Receptores NicotínicosRESUMEN
Multimodality imaging has emerged from a vision thirty years ago to routine clinical use today. Positron emission tomography (PET)/magnetic resonance imaging (MRI) is still relatively new in this arena and particularly suitable for clinical research and technical development. PET/MRI-guidance for interventions opens up opportunities for novel treatments but at the same time demands certain technical and organizational requirements to be fulfilled. In this work, we aimed to demonstrate a practical setting and potential application of PET/MRI guidance of interventional procedures. The superior quantitative physiologic information of PET, the various unique imaging characteristics of MRI, and the reduced radiation exposure are the most relevant advantages of this technique. As a noninvasive interventional tool, focused ultrasound (FUS) ablation of tumor cells would benefit from PET/MRI for diagnostics, treatment planning and intervention. Yet, technical limitations might impeed preclinical research, given that PET/MRI sites are per se not designed as interventional suites. Nonetheless, several approaches have been offered in the past years to upgrade MRI suites for interventional purposes. Taking advantage of state of the art and easy-to-use technology it is possible to create a supporting infrastructure that is suitable for broad preclinical adaption. Several aspects are to be addressed, including remote control of the imaging system, display of the imaging results, communication technology, and implementation of additional devices such as a FUS platform and an MR-compatible robotic system for positioning of the FUS equipment. Feasibility could be demostrated with an examplary experimental setup for interventional PET/MRI. Most PET/MRI sites could allow for interventions with just a few add-ons and modifications, such as comunication, in room image display and sytems control. By unlocking this feature, and driving preclinical research in interventional PET/MRI, translation of the protocol and methodology into clinical settings seems feasible.
Asunto(s)
Imagen por Resonancia Magnética Intervencional/métodos , Neoplasias/diagnóstico por imagen , Neoplasias/tratamiento farmacológico , Tomografía de Emisión de Positrones/métodos , Diseño de Equipo , Humanos , Aumento de la Imagen , Procesamiento de Imagen Asistido por Computador , Imagen MultimodalRESUMEN
BACKGROUND: The combination of positron emission tomography (PET) and magnetic resonance imaging (MRI) (PET-MRI) is a unique hybrid imaging modality mainly used in oncology and neurology. The MRI-based attenuation correction (MRAC) is crucial for correct quantification of PET data. A suitable phantom to validate quantitative results in PET-MRI is currently missing. In particular, the correction of attenuation due to bone is usually not verified by commonly available phantoms. The aim of this work was, thus, the development of such a phantom and to explore whether such a phantom might be used to validate MRACs. METHOD: Various materials were investigated for their attenuation and MR properties. For the substitution of bone, water-saturated gypsum plaster was used. The attenuation of 511 keV annihilation photons was regulated by addition of iodine. Adipose tissue was imitated by silicone and brain tissue by agarose gel, respectively. The practicability with respect to the comparison of MRACs was checked as follows: A small flask inserted into the phantom and a large spherical phantom (serving as a reference with negligible error in MRAC) were filled with the very same activity concentration. The activity concentration was measured and compared using clinical protocols on PET-MRI and different built-in and offline MRACs. The same measurements were carried out using PET-CT for comparison. RESULTS: The phantom imitates the human head in sufficient detail. All tissue types including bone were detected as such so that the phantom-based comparison of the quantification accuracy of PET-MRI was possible. Quantitatively, the activity concentration in the brain, which was determined using different MRACs, showed a deviation of about 5% on average and a maximum deviation of 11% compared to the spherical phantom. For PET-CT, the deviation was 5%. CONCLUSIONS: The comparatively small error in quantification indicates that it is possible to construct a brain PET-MRI phantom that leads to MR-based attenuation-corrected images with reasonable accuracy.
RESUMEN
Overexpression of monocarboxylate transporters (MCTs) has been shown for a variety of human cancers (e.g., colon, brain, breast, and kidney) and inhibition resulted in intracellular lactate accumulation, acidosis, and cell death. Thus, MCTs are promising targets to investigate tumor cancer metabolism with positron emission tomography (PET). Here, the organ doses (ODs) and the effective dose (ED) of the first 18F-labeled MCT1/MCT4 inhibitor were estimated in juvenile pigs. Whole-body dosimetry was performed in three piglets (age: ~6 weeks, weight: ~13-15 kg). The animals were anesthetized and subjected to sequential hybrid Positron Emission Tomography and Computed Tomography (PET/CT) up to 5 h after an intravenous (iv) injection of 156 ± 54 MBq [18F]FACH. All relevant organs were defined by volumes of interest. Exponential curves were fitted to the time-activity data. Time and mass scales were adapted to the human order of magnitude and the ODs calculated using the ICRP 89 adult male phantom with OLINDA 2.1. The ED was calculated using tissue weighting factors as published in Publication 103 of the International Commission of Radiation Protection (ICRP103). The highest organ dose was received by the urinary bladder (62.6 ± 28.9 µSv/MBq), followed by the gall bladder (50.4 ± 37.5 µSv/MBq) and the pancreas (30.5 ± 27.3 µSv/MBq). The highest contribution to the ED was by the urinary bladder (2.5 ± 1.1 µSv/MBq), followed by the red marrow (1.7 ± 0.3 µSv/MBq) and the stomach (1.3 ± 0.4 µSv/MBq). According to this preclinical analysis, the ED to humans is 12.4 µSv/MBq when applying the ICRP103 tissue weighting factors. Taking into account that preclinical dosimetry underestimates the dose to humans by up to 40%, the conversion factor applied for estimation of the ED to humans would rise to 20.6 µSv/MBq. In this case, the ED to humans upon an iv application of ~300 MBq [18F]FACH would be about 6.2 mSv. This risk assessment encourages the translation of [18F]FACH into clinical study phases and the further investigation of its potential as a clinical tool for cancer imaging with PET.
Asunto(s)
Transportadores de Ácidos Monocarboxílicos/antagonistas & inhibidores , Neoplasias/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Radiometría/métodos , Radiofármacos/farmacología , Simportadores/antagonistas & inhibidores , Distribución Tisular/efectos de los fármacos , Animales , Médula Ósea/efectos de los fármacos , Radioisótopos de Flúor , Radiofármacos/síntesis química , Radiofármacos/química , Estómago/efectos de los fármacos , Porcinos , Tomografía Computarizada por Rayos X/métodos , Vejiga Urinaria/efectos de los fármacosRESUMEN
These joint practice guidelines, or procedure standards, were developed collaboratively by the European Association of Nuclear Medicine (EANM), the Society of Nuclear Medicine and Molecular Imaging (SNMMI), the European Association of Neurooncology (EANO), and the working group for Response Assessment in Neurooncology with PET (PET-RANO). Brain PET imaging is being increasingly used to supplement MRI in the clinical management of glioma. The aim of these standards/guidelines is to assist nuclear medicine practitioners in recommending, performing, interpreting and reporting the results of brain PET imaging in patients with glioma to achieve a high-quality imaging standard for PET using FDG and the radiolabelled amino acids MET, FET and FDOPA. This will help promote the appropriate use of PET imaging and contribute to evidence-based medicine that may improve the diagnostic impact of this technique in neurooncological practice. The present document replaces a former version of the guidelines published in 2006 (Vander Borght et al. Eur J Nucl Med Mol Imaging. 33:1374-80, 2006), and supplements a recent evidence-based recommendation by the PET-RANO working group and EANO on the clinical use of PET imaging in patients with glioma (Albert et al. Neuro Oncol. 18:1199-208, 2016). The information provided should be taken in the context of local conditions and regulations.
Asunto(s)
Aminoácidos , Fluorodesoxiglucosa F18 , Glioma/diagnóstico por imagen , Medicina Nuclear , Tomografía de Emisión de Positrones/normas , Guías de Práctica Clínica como Asunto , Sociedades Médicas , Adulto , Niño , Humanos , Procesamiento de Imagen Asistido por Computador , Marcaje Isotópico , Control de Calidad , Recurrencia , Estándares de Referencia , Proyectos de InvestigaciónRESUMEN
BACKGROUND: Current research diagnostic criteria for Alzheimer's disease (AD) and mild cognitive impairment (MCI) due to AD include biomarkers to supplement clinical testing. Recently, we demonstrated that dual time-point [18F]FBB PET is able to deliver both blood flow and amyloid-ß (Aß) load surrogates. OBJECTIVE: The aim of this study was to investigate whether these surrogates can be utilized as AD biomarkers. METHODS: 112 subjects (41 with MCI, 50 with probable/possible AD, 21 with other dementias) underwent dual time-point [18F]FBB PET. Data were visually and relative quantitatively (Herholz scores for the early and composite SUVRs for the late PET data) analyzed. RESULTS: In the early images AD-typical patterns were present in 42% /27% /33% of probable/possible AD/MCI/other dementia cases. In late [18F]FBB PET, 42% /29% /38% of probable/possible AD/ MCI/other dementia cases were Aß-positive. 17% of the MCIs were categorized as "MCI due to AD-high likelihood", 44% of the probable ADs as "probable AD with high evidence of AD pathophysiological process" and 28% of the possible ADs as "possible AD with evidence of AD pathophysiological process". 27% of all subjects showed a positive diagnostic and progression biomarker. Herholz scores were lower (0.85±0.05 versus 0.88±0.04, pâ=â0.015) for probable/possible AD versus MCI. Composite late phase SUVRs were significantly higher (1.65±0.23 versus 1.15±0.17, pâ<â0.005) in Aß-positive versus Aß-negative patients. Herholz and MMSE scores were positively correlated (Râ=â0.30 pâ=â0.006). CONCLUSION: Dual time-point [18F]FBB PET provides dual biomarker information which enables to categorize MCI and AD dementia patients according to established diagnostic criteria. Thus, dual time-point [18F]FBB PET has great potential to supplement diagnostic dementia workups.
Asunto(s)
Enfermedad de Alzheimer/diagnóstico por imagen , Encéfalo/diagnóstico por imagen , Disfunción Cognitiva/diagnóstico por imagen , Tomografía de Emisión de Positrones/métodos , Anciano , Anciano de 80 o más Años , Compuestos de Anilina , Biomarcadores , Diagnóstico Diferencial , Femenino , Radioisótopos de Flúor , Humanos , Masculino , Persona de Mediana Edad , Neuroimagen/métodos , Estudios Retrospectivos , EstilbenosRESUMEN
In early Alzheimer's dementia, there is a need for PET biomarkers of disease progression with close associations to cognitive dysfunction that may aid to predict further cognitive decline and neurodegeneration. Amyloid biomarkers are not suitable for that purpose. The α4ß2 nicotinic acetylcholine receptors (α4ß2-nAChRs) are widely abundant in the human brain. As neuromodulators they play an important role in cognitive functions such as attention, learning and memory. Post-mortem studies reported lower expression of α4ß2-nAChRs in more advanced Alzheimer's dementia. However, there is ongoing controversy whether α4ß2-nAChRs are reduced in early Alzheimer's dementia. Therefore, using the recently developed α4ß2-nAChR-specific radioligand (-)-18F-flubatine and PET, we aimed to quantify the α4ß2-nAChR availability and its relationship to specific cognitive dysfunction in mild Alzheimer's dementia. Fourteen non-smoking patients with mild Alzheimer's dementia, drug-naïve for cholinesterase therapy, were compared with 15 non-smoking healthy controls matched for age, sex and education by applying (-)-18F-flubatine PET together with a neuropsychological test battery. The one-tissue compartment model and Logan plot method with arterial input function were used for kinetic analysis to obtain the total distribution volume (VT) as the primary, and the specific binding part of the distribution volume (VS) as the secondary quantitative outcome measure of α4ß2-nAChR availability. VS was determined by using a pseudo-reference region. Correlations between VT within relevant brain regions and Z-scores of five cognitive functions (episodic memory, executive function/working memory, attention, language, visuospatial function) were calculated. VT (and VS) were applied for between-group comparisons. Volume of interest and statistical parametric mapping analyses were carried out. Analyses revealed that in patients with mild Alzheimer's dementia compared to healthy controls, there was significantly lower VT, especially within the hippocampus, fronto-temporal cortices, and basal forebrain, which was similar to comparisons of VS. VT decline in Alzheimer's dementia was associated with distinct domains of impaired cognitive functioning, especially episodic memory and executive function/working memory. Using (-)-18F-flubatine PET in patients with mild Alzheimer's dementia, we show for the first time a cholinergic α4ß2-nAChR deficiency mainly present within the basal forebrain-cortical and septohippocampal cholinergic projections and a relationship between lower α4ß2-nAChR availability and impairment of distinct cognitive domains, notably episodic memory and executive function/working memory. This shows the potential of (-)-18F-flubatine as PET biomarker of cholinergic α4ß2-nAChR dysfunction and specific cognitive decline. Thus, if validated by longitudinal PET studies, (-)-18F-flubatine might become a PET biomarker of progression of neurodegeneration in Alzheimer's dementia.
Asunto(s)
Enfermedad de Alzheimer/complicaciones , Trastornos del Conocimiento/etiología , Trastornos del Conocimiento/metabolismo , Receptores Nicotínicos/metabolismo , Factores de Edad , Anciano , Anciano de 80 o más Años , Enfermedad de Alzheimer/diagnóstico por imagen , Atención/fisiología , Benzamidas/farmacocinética , Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Compuestos Bicíclicos Heterocíclicos con Puentes/farmacocinética , Trastornos del Conocimiento/diagnóstico por imagen , Estudios de Cohortes , Escolaridad , Función Ejecutiva , Femenino , Humanos , Masculino , Memoria a Corto Plazo/fisiología , Persona de Mediana Edad , Pruebas Neuropsicológicas , Tomografía de Emisión de Positrones , Factores SexualesRESUMEN
Quantitative positron emission tomography/computed tomography (PET/CT) can be used as diagnostic or prognostic tools (i.e. single measurement) or for therapy monitoring (i.e. longitudinal studies) in multicentre studies. Use of quantitative parameters, such as standardized uptake values (SUVs), metabolic active tumor volumes (MATVs) or total lesion glycolysis (TLG), in a multicenter setting requires that these parameters be comparable among patients and sites, regardless of the PET/CT system used. This review describes the motivations and the methodologies for quantitative PET/CT performance harmonization with emphasis on the EANM Research Ltd. (EARL) Fluorodeoxyglucose (FDG) PET/CT accreditation program, one of the international harmonization programs aiming at using FDG PET as a quantitative imaging biomarker. In addition, future accreditation initiatives will be discussed. The validation of the EARL accreditation program to harmonize SUVs and MATVs is described in a wide range of tumor types, with focus on therapy assessment using either the European Organization for Research and Treatment of Cancer (EORTC) criteria or PET Evaluation Response Criteria in Solid Tumors (PERCIST), as well as liver-based scales such as the Deauville score. Finally, also presented in this paper are the results from a survey across 51 EARL-accredited centers reporting how the program was implemented and its impact on daily routine and in clinical trials, harmonization of new metrics such as MATV and heterogeneity features.
Asunto(s)
Estudios Multicéntricos como Asunto , Neoplasias/diagnóstico por imagen , Tomografía de Emisión de Positrones/métodos , Sociedades Médicas , Humanos , Imagen por Resonancia Magnética , Tomografía de Emisión de Positrones/normas , Estándares de ReferenciaRESUMEN
This paper highlights the origins of combined positron emission tomography (PET) and magnetic resonance imaging (MRI) whole-body systems that were first introduced for applications in humans in 2010. This text first covers basic aspects of each imaging modality before describing the technical and methodological challenges of combining PET and MRI within a single system. After several years of development, combined and even fully-integrated PET/MRI systems have become available and made their way into the clinic. This multi-modality imaging system lends itself to the advanced exploration of diseases to support personalized medicine in a long run. To that extent, this paper provides an introduction to PET/MRI methodology and important technical solutions.