Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
1.
Acta Otolaryngol ; 144(5-6): 366-370, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39250174

RESUMEN

BACKGROUND: Previous studies found that in patients with profound hearing loss the NEO- personality factor Openness-to-experience is lowered. OBJECTIVE: Assuming that lowered Openness-to-experience may be due to limited access to sounds, we hypothesized that levels of Openness-to-experience would increase in these patients after cochlear implantation. MATERIAL AND METHODS: Twenty adults (mean age: 61 years; active CI users) with bilateral profound hearing loss were assessed with the NEO-Five-Factor-Inventory before cochlear implantation (pre) and five years later (post). RESULTS: No significant pre-post changes in personality were seen. Both before and five years after cochlear implantation, the sample had normal age- and gender-specific mean values on the factors Extraversion, Neuroticism, Agreeableness, and Conscientiousness (T ≈ 50), but significantly lowered mean values on Openness-to-experience (T ≈ 42, p < 0.001). CONCLUSIONS AND SIGNIFICANCE: Cochlear implantation apparently has no (or at best very little) effect on Openness-to-experience in profoundly hearing impaired patients. While this study demonstrates once again, that high-grade hearing loss may be associated with less openness to new experiences, the reason for this association remains unclear.


Asunto(s)
Implantación Coclear , Personalidad , Humanos , Persona de Mediana Edad , Masculino , Femenino , Implantación Coclear/psicología , Estudios de Seguimiento , Anciano , Adulto , Pérdida Auditiva/psicología , Pérdida Auditiva/cirugía
2.
Artículo en Inglés | MEDLINE | ID: mdl-39179912

RESUMEN

OBJECTIVE: The goal of the study was to determine the short- and long-term outcome of health-related quality of life (HRQoL) in adults implanted with a Vibrant Soundbridge (VSB). METHODS: Twenty-one adults (8 females, 13 males; mean age at implantation: 57 ±10 years) who received a unilateral VSB for combined or conductive hearing loss, were administered two questionnaires: the Nijmegen Cochlear Implant Questionnaire (NCIQ) as a measure of hearing-specific HRQoL, and the Health Utility Index 3 (HUI 3) as a measure of generic HRQoL. The questionnaires were administered before implantation and three, six, 12 and 24 months after processor activation. RESULTS: The NCIQ total score raised significantly from 62 points before implantation to 76 points at three months after processor activation (p < 0.005). Thereafter, no significant increases occurred anymore. The HUI 3 multi-attribute score (MAUS) increased from 0.59 before implantation to 0.70 at three months and at six months after processor activation and then declined slightly to 0.68 at 24 months after processor activation. Similar values were observed with the HUI 3 single-attribute score (SAUS) of Hearing. The increases of the HUI 3 scores were not statistically significant, but all pre-post-implantation differences were clinically relevant. DISCUSSION: VSB recipients experienced a quick improvement of their HRQoL. After just three months of device use, a significant improvement of hearing-specific HRQoL and a clinically relevant improvement of generic HRQoL were seen. After three months, no essential changes of HRQoL occurred in our sample, suggesting that the achieved level of HRQoL may remain stable in the long term.

3.
Artículo en Inglés | MEDLINE | ID: mdl-39078472

RESUMEN

PURPOSE: To evaluate the diagnostic performance (DP) of the high-resolution contrast computed tomography (HR-contrast-CT) based Neck-Persistency-Net in distinguishing vital from non-vital persistent cervical lymph nodes (pcLNs) in patients with advanced head and neck squamous cell carcinoma (HNSCC) following primary concurrent chemoradiotherapy (CRT) with [18F]-fluorodeoxyglucose positron emission tomography and high-resolution contrast-enhanced computed tomography ([18F]FDG-PET-CT). Furthermore, the Neck-Persistency-Net's potential to justify omitting post-CRT neck dissection (ND) without risking treatment delays or preventing unnecessary surgery was explored. METHODS: All HNSCC patients undergoing primary CRT followed by post-CRT-ND for pcLNs recorded in the institutional HNSCC registry were analyzed. The Neck-Persistency-Net DP was explored for three scenarios: balanced performance (BalPerf), optimized sensitivity (OptSens), and optimized specificity (OptSpec). Histopathology of post-CRT-ND served as a reference. RESULTS: Among 68 included patients, 11 were female and 32 had vital pcLNs. The Neck-Persistency-Net demonstrated good DP with an area under the curve of 0.82. For BalPerf, both sensitivity and specificity were 78%; for OptSens (90%), specificity was 62%; for OptSpec (95%), sensitivity was 54%. Limiting post-CRT-ND to negative results would have delayed treatment in 27%, 40%, and 7% for BalPerf, OptSens and OptSpec, respectively, versus 23% for [18F]FDG-PET-CT. Conversely, restricting post-CRT-ND to positive results would have prevented unnecessary post-CRT-ND in 78%, 60%, and 95% for BalPerf, OptSens and OptSpec, respectively, versus 55% for [18F]FDG-PET-CT. CONCLUSION: The DP of the Neck-Persistency-Net was comparable to [18F]-FDG-PET-CT. Depending on the chosen decision boundary, the potential to justify the omission of post-CRT-ND without risking treatment delays in false negative findings or reliably prevent unnecessary surgery in false positive findings outperforms the [18F]-FDG-PET-CT.

4.
J Vis Exp ; (208)2024 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-38975780

RESUMEN

Measuring the electrically evoked stapedius reflex during the fitting of cochlear implants (CIs) provides a reliable estimation of maximum comfort levels, resulting in the programming of the CI with high hearing comfort and good speech understanding. Detection of the stapedius reflex and the required stimulation level on each implant channel is already being performed during surgery, whereby intraoperative stapedius reflexes are observed through the surgical microscope. Intraoperative stapedius reflex detection is both an indicator that the auditory nerve is responding to electrical stimulation up to the brainstem and a test for the ability to perform postoperative stapedius reflex measurements. Postoperative stapedius reflex thresholds can be used to estimate upper stimulation levels in the CI fitting process. In particular, in children or patients unable to provide feedback on loudness perception, this method avoids inadequate stimulation with the CI, which can result in poor hearing performance. In addition, overstimulation can be avoided, which could even lead to refusal to use the device.


Asunto(s)
Implantación Coclear , Estimulación Eléctrica , Estapedio , Humanos , Estapedio/fisiología , Implantación Coclear/métodos , Estimulación Eléctrica/métodos , Implantes Cocleares , Reflejo Acústico/fisiología
6.
Eur Arch Otorhinolaryngol ; 281(8): 4121-4131, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38564010

RESUMEN

PURPOSE: Cochlear implantation is a prevalent remedy for severe-to-profound hearing loss. Optimising outcomes and hearing preservation, and minimising insertion trauma, require precise electrode placement. Objective monitoring during the insertion process can provide valuable insights and enhance surgical precision. This study assesses the feasibility and performance of an impedance-based method for monitoring electrode insertion, compared to the surgeon's feedback. METHODS: The study utilised the Insertion Monitoring Tool (IMT) research software, allowing for real-time measurement of impedance and evoked compound action potential (eCAP) during electrode insertion in 20 patient implantations. This enabled an impedance-based method to continuously assess the status of each electrode during the insertion process. The feasibility and performance was evaluated and compared to the surgeon's feedback approach. eCAP measurements focused merely on feasibility without searching specific responses. RESULTS: The IMT demonstrated feasibility in measuring real-time impedances and eCAP during the insertion of the electrode array. The impedance-based method exhibited potential for accurately monitoring the insertion depth with a high success rate. However, further development is needed to improve the number of usable contacts. CONCLUSIONS: Objective monitoring with the impedance-based method shows promise as a valuable tool to enhance the precision of cochlear implant electrode insertion respecting insertion distance estimation. The IMT research software proved feasible in recording real-time impedances and eCAP during electrode insertion. While this impedance-based method exhibits high success rates, further improvements are required to optimise the number of usable contacts. This study highlights the potential of objective monitoring techniques to enhance cochlear implantation outcomes.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Impedancia Eléctrica , Estudios de Factibilidad , Humanos , Implantación Coclear/métodos , Masculino , Femenino , Persona de Mediana Edad , Adulto , Anciano , Niño , Preescolar , Adolescente , Electrodos Implantados , Potenciales Evocados Auditivos/fisiología , Adulto Joven , Monitoreo Intraoperatorio/métodos , Monitoreo Intraoperatorio/instrumentación
7.
Otol Neurotol ; 45(3): e228-e233, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38238908

RESUMEN

BACKGROUND AND OBJECTIVES: The ability to localize sounds is partly recovered in patients using a cochlear implant (CI) in one ear and a hearing aid (HA) on the contralateral side. Binaural processing seems effective at least to some extent, despite the difference between electric and acoustic stimulation in each ear. To obtain further insights into the mechanisms of binaural hearing in these listeners, localization of low- and high-frequency sounds was tested. STUDY DESIGN: The study used a within-subject design, where participants were tasked with localizing sound sources in the horizontal plane. The experiment was conducted in an anechoic chamber, where an array of seven loudspeakers was mounted along the 24 azimuthal angle span from -90° to +90°. Stimuli were applied with different frequencies: broadband noise and high- and low-frequency noise. SUBJECTS: Ten CI recipients participated in the study. All had an asymmetric hearing loss with a CI in the poorer ear and an HA on the contralateral side. MAIN OUTCOME MEASURES: Accuracy of sound localization in terms of angular error and percentage of correct localization scores. RESULTS: The median angular error was 40° in bimodal conditions for both broadband noise and high-frequency noise stimuli. The angular error increased to 47° for low-frequency noise stimuli. In the unilaterally aided condition with an HA, only a median angular error of 78° was observed. CONCLUSIONS: Irrespective of the frequency composition of the stimuli, this group of bimodal listeners showed some ability to localize sounds. Angular errors were larger than those reported in the literature for bilateral CI users or single-sided deaf listeners with a CI. In the unilateral listening condition with HA, only localization of sounds was not possible for most subjects.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Audífonos , Localización de Sonidos , Percepción del Habla , Humanos , Audición
9.
Cancers (Basel) ; 15(18)2023 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-37760620

RESUMEN

Patients with locally advanced head and neck squamous cell carcinoma (HNSCC) frequently require primary radiochemotherapy (RCT). Despite intensity modulation, the desired radiation-induced effects observed in HNSCC may also be observed as side effects in healthy tissue, e.g., the sternocleidomastoid muscle (SCM). These side effects (e.g., tissue fibrosis) depend on the interval between the completion of RCT and restaging CT. For salvage surgery, the optimal time window for surgery is currently clinically postulated at between 6 and 12 weeks after completion of RCT. Thus, no extensive tissue fibrosis is to be expected. This interval is based on clinical studies exploring surgical complications. Studies directly exploring radiation-induced changes of the SCM in HNSCC patients are sparse. The present study quantified tissue alterations in the SCM and paravertebral musculature (PVM) after RCT, applying radiomics to determine the optimal time window for salvage surgery. Three radiomic key parameters, (1) volume, (2) mean positivity of pixels (MPP), and (3) uniformity, were extracted with mint LesionTM in the staging CTs and restaging CTs of 98 HNSCC patients. Of these, 25 were female, the mean age was 62 (±9.6) years, and 80.9% were UICC Stage IV. The mean restaging interval was 55 (±28; range 29-229) days. Only the mean volume significantly decreased after RCT, from 9.0 to 8.4 and 96.5 to 91.9 mL for the SCM and PVM, respectively (both p = 0.007, both Cohen's d = 0.28). In addition, the mean body mass index (BMI) decreased from 23.9 (±4.2) to 21.0 (±3.6) kg/m² (p < 0.001; Cohen's d = 0.9). The mean BMI decreased significantly and was correlated with the volume decrease for the SCM (r = 0.27; p = 0.007) and PVM (r = 0.41; p < 0.001). If t-test p-values were adjusted for the BMI decrease, no significant change in volumes for the SCM and PVM was observed (both p > 0.05). The present data support the clinically postulated optimal interval for salvage surgery of 6 to 12 weeks.

10.
J Vis Exp ; (198)2023 08 04.
Artículo en Inglés | MEDLINE | ID: mdl-37590502

RESUMEN

Impedance measurements are routinely performed during cochlear implantation (CI) after finalized electrode insertion. They may allow conclusions on the electrode's and implant's function. In the postoperative setting, the analysis of impedance changes enables the identification of scarring or inflammation processes around the electrode. Recent studies report associations between impedance telemetry and the site of stimulation. Consequently, repeated impedance measurements during cochlear implant electrode insertion may enable objective feedback on whether the electrode is positioned inside the perilymph or outside the inner ear. With the presented novel method, impedances can be measured in real-time during cochlear implantation. This protocol systematically explains how to perform repeated impedance recordings during CI surgery. These repeated measurements are challenging since they depend on multiple intraoperative methodological factors starting with the draping of the patient. Thus, for successful recordings, a standardized procedure is mandatory. In this article, we comprehensively illustrate the system setup and procedure of performing intraoperative measurements during CI surgery.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Humanos , Impedancia Eléctrica , Cicatriz , Telemetría
11.
Int J Mol Sci ; 24(10)2023 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-37240196

RESUMEN

Globally, over the next few decades, more than 2.5 billion people will suffer from hearing impairment, including profound hearing loss, and millions could potentially benefit from a cochlea implant. To date, several studies have focused on tissue trauma caused by cochlea implantation. The direct immune reaction in the inner ear after an implantation has not been well studied. Recently, therapeutic hypothermia has been found to positively influence the inflammatory reaction caused by electrode insertion trauma. The present study aimed to evaluate the hypothermic effect on the structure, numbers, function and reactivity of macrophages and microglial cells. Therefore, the distribution and activated forms of macrophages in the cochlea were evaluated in an electrode insertion trauma cochlea culture model in normothermic and mild hypothermic conditions. In 10-day-old mouse cochleae, artificial electrode insertion trauma was inflicted, and then they were cultured for 24 h at 37 °C and 32 °C. The influence of mild hypothermia on macrophages was evaluated using immunostaining of cryosections using antibodies against IBA1, F4/80, CD45 and CD163. A clear influence of mild hypothermia on the distribution of activated and non-activated forms of macrophages and monocytes in the inner ear was observed. Furthermore, these cells were located in the mesenchymal tissue in and around the cochlea, and the activated forms were found in and around the spiral ganglion tissue at 37 °C. Our findings suggest that mild hypothermic treatment has a beneficial effect on immune system activation after electrode insertion trauma.


Asunto(s)
Hipotermia Inducida , Hipotermia , Ratones , Animales , Cóclea , Electrodos Implantados , Macrófagos
12.
Front Pediatr ; 11: 1124567, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37234860

RESUMEN

Background: The role of respiratory viruses in chronic otitis media with effusion (COME) in children is not clearly defined. In our study we aimed to investigate the detection of respiratory viruses in middle ear effusions (MEE) as well as the association with local bacteria, respiratory viruses in the nasopharynx and cellular immune response of children with COME. Methods: This 2017-2019 cross-sectional study included 69 children aged 2-6 undergoing myringotomy for COME. MEE and nasopharyngeal swabs were analyzed via PCR and CT-values for the genome and loads of typical respiratory viruses. Immune cell populations and exhaustion markers in MEE related to respiratory virus detection were studied via FACS. Clinical data including the BMI was correlated. Results: Respiratory viruses were detected in MEE of 44 children (64%). Rhinovirus (43%), Parainfluenzavirus (26%) and Bocavirus (10%) were detected most frequently. Average Ct values were 33.6 and 33.5 in MEE and nasopharynx, respectively. Higher detection rates correlated with elevated BMI. Monocytes were elevated in MEE (9.5 ± 7.3%/blood leucocytes). Exhaustion markers were elevated on CD4+ and CD8+ T cells and monocytes in MEE. Conclusion: Respiratory viruses are associated with pediatric COME. Elevated BMI was associated with increased rates of virus associated COME. Changes in cell proportions of innate immunity and expression of exhaustion markers may be related to chronic viral infection.

13.
Front Neurosci ; 17: 1112243, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37123355

RESUMEN

Introduction: Local therapeutic hypothermia (32°C) has been linked experimentally to an otoprotective effect in the electrode insertion trauma. The pathomechanism of the electrode insertion trauma is connected to the activation of apoptosis and necrosis pathways, pro-inflammatory and fibrotic mechanisms. In a whole organ cochlea culture setting the effect of therapeutic hypothermia in an electrode insertion trauma model is evaluated. Material and Methods: The cochleae of C57Bl6/J mice (Charles River®, Freiburg, Germany) are cultured for 24 hours at 37°C and 32°C after inserting a fishing line through the round window simulating an insertion trauma. The resulting effect was evaluated for the apoptotic reaction - B-cell-Lymphoma-2-Associated-X-Protein (BAX), B-Cell-Lymphoma-2-Protein (BCL2) and Cleaved-Caspase-3 (CC3) -, the inflammatory response - Tumor-Necrosis-Factor-Alpha (TNFα), Interleukin-1-Beta (IL-1Imm) and Cyclooxygenase-2 (COX2) - and proliferation process - Transforming-Growth-Factor-Beta-1 (TGFß1) - using immunohistochemistry and real-time PCR technique. A minimum of 12 cochlea per experiment were used. Results: A pro-apoptotic situation was observed in the normothermic group (BAX, CC3 ˃ Bcl2) whereas an anti-apoptotic constellation was found at 32°C culture conditions (BAX, CC3 < Bcl2). Furthermore the effect of the IT knowing to effect the pro-inflammatory cytokine (TNFα, Il1ß) and enzyme (COX2) expression has been reproduced. This reaction was reversed with the application of therapeutic hypothermia resulting in significant lower pro-inflammatory cytokine (TNFα, Il1ß) and enzyme (COX2) expression. TGFß1 was increased by hypothermia. Discussion: Concluding a protective effect of hypothermia on the experimental electrode insertion trauma can be described by an anti-apoptotic and anti-inflammatory reaction.

16.
Eur Arch Otorhinolaryngol ; 280(4): 1565-1579, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36625869

RESUMEN

AIM: This European multicentric study aimed to prove safety and performance of the Bonebridge BCI 602 in children and adults suffering from either conductive hearing loss (CHL), mixed hearing loss (MHL), or single-sided sensorineural deafness (SSD). METHODS: 33 patients (13 adults and 10 children with either CHL or MHL and 10 patients with SSD) in three study groups were included. Patients were their own controls (single-subject repeated measures), comparing the unaided or pre-operative to the 3-month post-operative outcomes. Performance was evaluated by sound field thresholds (SF), word recognition scores (WRS) and/or speech reception thresholds in quiet (SRT) and in noise (SNR). Safety was demonstrated with a device-specific surgical questionnaire, adverse event reporting and stable pure-tone measurements. RESULTS: The Bonebridge BCI 602 significantly improved SF thresholds (+ 25.5 dB CHL/MHL/SSD), speech intelligibility in WRS (+ 68.0% CHL/MHL) and SRT in quiet (- 16.5 dB C/MHL) and in noise (- 3.51 dB SNR SSD). Air conduction (AC) and bone conduction (BC) thresholds remained stable over time. All adverse events were resolved, with none unanticipated. Mean audio processor wearing times in hours [h] per day for the CHL/MHL group were ~ 13 h for adults, ~ 11 h for paediatrics and ~ 6 h for the SSD group. The average surgical length was 57 min for the CHL/MHL group and 42 min for the SSD group. The versatility of the BCI 602 (reduced drilling depth and ability to bend the transition for optimal placement) allows for treatment of normal, pre-operated and malformed anatomies. All audiological endpoints were reached. CONCLUSIONS: The Bonebridge BCI 602 significantly improved hearing thresholds and speech understanding. Since implant placement follows the patient's anatomy instead of the shape of the device and the duration of surgery is shorter than with its predecessor, implantation is easier with the BCI 602. Performance and safety were proven for adults and children as well as for the CHL/MHL and SSD indications 3 months post-operatively.


Asunto(s)
Interfaces Cerebro-Computador , Sordera , Audífonos , Perdida Auditiva Conductiva-Sensorineural Mixta , Pérdida Auditiva Sensorineural , Pérdida Auditiva , Percepción del Habla , Adulto , Humanos , Niño , Conducción Ósea , Audición , Perdida Auditiva Conductiva-Sensorineural Mixta/cirugía , Pérdida Auditiva Conductiva/cirugía , Sordera/cirugía , Pérdida Auditiva/cirugía , Pérdida Auditiva Sensorineural/cirugía , Resultado del Tratamiento , Estudios Multicéntricos como Asunto
17.
Otol Neurotol Open ; 3(4): e045, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38516541

RESUMEN

Objective: The suitable electrode array choice is broadly discussed in cochlear implantation surgery. Whether to use a shorter electrode length under the aim of structure preservation versus choosing a longer array to achieve a greater cochlear coverage is a matter of debate. The aim of this review is to identify the impact of the insertion depth of a cochlear implant (CI) electrode array on CI users' speech perception outcomes. Databases Reviewed: PubMed was searched for English-language articles that were published in a peer-reviewed journal from 1997 to 2022. Methods: A systematic electronic search of the literature was carried out using PubMed to find relevant literature on the impact of insertion depth on speech perception. The review was conducted according to the preferred reporting items for systematic reviews and meta-analyses guidelines of reporting. Studies in both, children and adults with pre- or postlingual hearing loss, implanted with a CI were included in this study. Articles written in languages other than English, literature reviews, meta-analyses, animal studies, histopathological studies, or studies pertaining exclusively to imaging modalities without reporting correlations between insertion depth and speech outcomes were excluded. The risk of bias was determined using the "Risk of Bias in Nonrandomized Studies of Interventions" tool. Articles were extracted by 2 authors independently using predefined search terms. The titles and abstracts were screened manually to identify studies that potentially meet the inclusion criteria. The extracted information included: the study population, type of hearing loss, outcomes reported, devices used, speech perception outcomes, insertion depth (linear insertion depth and/or the angular insertion depth), and correlation between insertion depth and the speech perception outcomes. Results: A total of 215 relevant studies were assessed for eligibility. Twenty-three studies met the inclusion criteria and were analyzed further. Seven studies found no significant correlation between insertion depth and speech perception outcomes. Fifteen found either a significant positive correlation or a positive effect between insertion depth and speech perception. Only 1 study found a significant negative correlation between insertion depth and speech perception outcomes. Conclusion: Although most studies reported a positive effect of insertion depth on speech perception outcomes, one-third of the identified studies reported no correlation. Thus, the insertion depth must be considered as a contributing factor to speech perception rather than as a major decisive criterion. Registration: This review has been registered in PROSPERO, the international prospective register of systematic reviews (CRD42021257547), available at https://www.crd.york.ac.uk/PROSPERO/.

18.
Cancers (Basel) ; 14(21)2022 Nov 02.
Artículo en Inglés | MEDLINE | ID: mdl-36358815

RESUMEN

Locally-advanced head and neck squamous cell carcinoma (HNSCC) is mainly defined by the presence of pathologic cervical lymph nodes (LNs) with or without extracapsular spread (ECS). Current radiologic criteria to classify LNs as non-pathologic, pathologic, or pathologic with ECS are primarily shape-based. However, significantly more quantitative information is contained within imaging modalities. This quantitative information could be exploited for classification of LNs in patients with locally-advanced HNSCC by means of artificial intelligence (AI). Currently, various reviews exploring the role of AI in HNSCC are available. However, reviews specifically addressing the current role of AI to classify LN in HNSCC-patients are sparse. The present work systematically reviews original articles that specifically explore the role of AI to classify LNs in locally-advanced HNSCC applying Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) guidelines and the Study Quality Assessment Tool of National Institute of Health (NIH). Between 2001 and 2022, out of 69 studies a total of 13 retrospective, mainly monocentric, studies were identified. The majority of the studies included patients with oropharyngeal and oral cavity (9 and 7 of 13 studies, respectively) HNSCC. Histopathologic findings were defined as reference in 9 of 13 studies. Machine learning was applied in 13 studies, 9 of them applying deep learning. The mean number of included patients was 75 (SD ± 72; range 10-258) and of LNs was 340 (SD ± 268; range 21-791). The mean diagnostic accuracy for the training sets was 86% (SD ± 14%; range: 43-99%) and for testing sets 86% (SD ± 5%; range 76-92%). Consequently, all of the identified studies concluded AI to be a potentially promising diagnostic support tool for LN-classification in HNSCC. However, adequately powered, prospective, and randomized control trials are urgently required to further assess AI's role in LN-classification in locally-advanced HNSCC.

19.
J Pers Med ; 12(10)2022 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-36294690

RESUMEN

This study aimed to discover expert opinion on the surgical techniques and materials most likely to achieve maximum postoperative residual hearing preservation in cochlear implant (CI) surgery and to determine how these opinions have changed since 2010. A previously published questionnaire used in a study published in 2010 was adapted and expanded. The questionnaire was distributed to an international group of experienced CI surgeons. Present results were compared, via descriptive statistics, to those from the 2010 survey. Eighteen surgeons completed the questionnaire. Respondents clearly favored the following: round window insertion, slow array insertion, and the peri- and postoperative use of systematic antibiotics. Insertion depth was regarded as important, and electrode arrays less likely to induce trauma were preferred. The usefulness of dedicated soft-surgery training was also recognized. A lack of agreement was found on whether the middle ear cavity should be flushed with a non-aminoglycoside antibiotic solution or whether a sheath or insertion tube should be used to avoid contaminating the array with blood or bone dust. In conclusion, this paper demonstrates how beliefs about CI soft surgery have changed since 2010 and shows areas of current consensus and disagreement.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA