RESUMEN
Background: Reliable data on the adult SARS-CoV-2 infection fatality rate in Germany are still scarce. We performed a federal state-wide cross-sectional seroprevalence study named SaarCoPS, that is representative for the adult population including elderly individuals and nursing home residents in the Saarland. Methods: Serum was collected from 2940 adults via stationary or mobile teams during the 1st pandemic wave steady state period. We selected an antibody test system with maximal specificity, also excluding seroreversion effects due to a high longitudinal test performance. For the calculations of infection and fatality rates, we accounted for the delays of seroconversion and death after infection. Results: Using a highly specific total antibody test detecting anti-SARS-CoV-2 responses over more than 180 days, we estimate an adult infection rate of 1.02% (95% CI: [0.64; 1.44]), an underreporting rate of 2.68-fold (95% CI: [1.68; 3.79]) and infection fatality rates of 2.09% (95% CI: (1.48; 3.32]) or 0.36% (95% CI: [0.25; 0.59]) in all adults including elderly individuals, or adults younger than 70 years, respectively. Conclusion: The study highlights the importance of study design and test performance for seroprevalence studies, particularly when seroprevalences are low. Our results provide a valuable baseline for evaluation of future pandemic dynamics and impact of public health measures on virus spread and human health in comparison to neighbouring countries such as Luxembourg or France.
RESUMEN
BACKGROUND: The tension band wiring technique is the most common method of transverse patella fracture fixation. Since post-operative instabilities have been reported for this technique, alternative osteosynthesis solutions are of interest. We investigated the biomechanical behaviour of a new staple technique for treatment of transverse patella fractures in a cadaveric model. METHODS: Eight human cadaveric knees with femur and tibia including soft tissue were used. A transverse osteotomy of the patella was created. Each specimen was fixed consecutively with tension band wiring and two Nitinol compression staples. Testing was performed by pull on the quadriceps tendon between a 90 degrees flexed position and full knee extension for up to 5,000 cycles. FINDINGS: At 1,000 cycles, fracture site displacements in flexion and extension were significantly smaller for the staple group at the ventral aspect of the patella as compared to the tension band wiring group. With a failure criterion of 2mm fracture site displacement, cycles until failure were significantly smaller for the staple group. INTERPRETATION: This study provides evidence based on a cadaveric model that compression staples have a promising potential to treat transverse patella fractures.