Resultados 1 - 14 de 14
Filtrar
1.
Commun Med (Lond) ; 4(1): 146, 2024 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-39026075

RESUMEN

BACKGROUND: 7 T cardiac magnetic resonance imaging (MRI) studies may enable higher precision in clinical metrics like cardiac function, ventricular mass, and more. Higher precision may allow early detection of functional impairment and early evaluation of treatment responses in clinical practice and pre-clinical studies. METHODS: Seven female German Landrace pigs were scanned prior to and at three time points (3-4 days, 7-10 days, and ~60 days) post myocardial infarction using a whole body 7 T system and three radiofrequency (RF) coils developed and built in-house to accompany animal growth. RESULTS: The combination of dedicated RF hardware and 7 T MRI enables a longitudinal study in a pig model of acute and chronic infarction, providing consistent blood tissue contrast and high signal-to-noise ratio (SNR) in measurements of cardiac function, as well as low coefficients of variation (CoV) for ejection fraction (CoVintra-observer: 2%, CoVinter-observer: 3.8%) and infarct size (CoVintra-observer: 8.4%, CoVinter-observer: 3.8%), despite drastic animal growth. CONCLUSIONS: Best results are achieved via manual segmentation. We define state-of-the-art procedures for large animal studies at 7 T.


In magnetic resonance imaging (MRI), scanners use magnets to generate detailed images of structures in the body, such as the heart. Stronger magnets can produce stronger magnetic fields, which can be leveraged for better image quality and developing new methods for disease diagnosis. In clinical practice, such systems using strong magnets are not yet used for imaging of the heart and some safety aspects remain challenging. We apply such an imaging approach in pigs, in which heart structure and function are similar to humans. We focus on the most important clinical imaging aspects following a heart attack, namely heart function and scar detection. We demonstrate that the high magnetic strength system enabled consistent image quality and accuracy. These findings may help to guide future developments in MRI of the heart, for example in patients who have had a heart attack.

2.
PLoS One ; 16(7): e0252797, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34297720

RESUMEN

INTRODUCTION: Cardiac magnetic resonance (CMR) at ultrahigh field (UHF) offers the potential of high resolution and fast image acquisition. Both technical and physiological challenges associated with CMR at 7T require specific hardware and pulse sequences. This study aimed to assess the current status and existing, publicly available technology regarding the potential of a clinical application of 7T CMR. METHODS: Using a 7T MRI scanner and a commercially available radiofrequency coil, a total of 84 CMR examinations on 72 healthy volunteers (32 males, age 19-70 years, weight 50-103 kg) were obtained. Both electrocardiographic and acoustic triggering were employed. The data were analyzed regarding the diagnostic image quality and the influence of patient and hardware dependent factors. 50 complete short axis stacks and 35 four chamber CINE views were used for left ventricular (LV) and right ventricular (RV), mono-planar LV function, and RV fractional area change (FAC). Twenty-seven data sets included aortic flow measurements that were used to calculate stroke volumes. Subjective acceptance was obtained from all volunteers with a standardized questionnaire. RESULTS: Functional analysis showed good functions of LV (mean EF 56%), RV (mean EF 59%) and RV FAC (mean FAC 52%). Flow measurements showed congruent results with both ECG and ACT triggering. No significant influence of experimental parameters on the image quality of the LV was detected. Small fractions of 5.4% of LV and 2.5% of RV segments showed a non-diagnostic image quality. The nominal flip angle significantly influenced the RV image quality. CONCLUSION: The results demonstrate that already now a commercially available 7T MRI system, without major methods developments, allows for a solid morphological and functional analysis similar to the clinically established CMR routine approach. This opens the door towards combing routine CMR in patients with development of advanced 7T technology.


Asunto(s)
Imagen por Resonancia Magnética , Adulto , Anciano , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Volumen Sistólico , Función Ventricular Derecha , Adulto Joven
3.
Magn Reson Med ; 86(4): 2179-2191, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34002412

RESUMEN

PURPOSE: Artificial neural networks show promising performance in automatic segmentation of cardiac MRI. However, training requires large amounts of annotated data and generalization to different vendors, field strengths, sequence parameters, and pathologies is limited. Transfer learning addresses this challenge, but specific recommendations regarding type and amount of data required is lacking. In this study, we assess data requirements for transfer learning to experimental cardiac MRI at 7T where the segmentation task can be challenging. In addition, we provide guidelines, tools, and annotated data to enable transfer learning approaches by other researchers and clinicians. METHODS: A publicly available segmentation model was used to annotate a publicly available data set. This labeled data set was subsequently used to train a neural network for segmentation of left ventricle and myocardium in cardiac cine MRI. The network is used as starting point for transfer learning to 7T cine data of healthy volunteers (n = 22; 7873 images) by updating the pre-trained weights. Structured and random data subsets of different sizes were used to systematically assess data requirements for successful transfer learning. RESULTS: Inconsistencies in the publically available data set were corrected, labels created, and a neural network trained. On 7T cardiac cine images the model pre-trained on public imaging data, acquired at 1.5T and 3T, achieved DICELV = 0.835 and DICEMY = 0.670. Transfer learning using 7T cine data and ImageNet weight initialization improved model performance to DICELV = 0.900 and DICEMY = 0.791. Using only end-systolic and end-diastolic images reduced training data by 90%, with no negative impact on segmentation performance (DICELV = 0.908, DICEMY = 0.805). CONCLUSIONS: This work demonstrates and quantifies the benefits of transfer learning for cardiac cine image segmentation. We provide practical guidelines for researchers planning transfer learning projects in cardiac MRI and make data, models, and code publicly available.


Asunto(s)
Aprendizaje Profundo , Corazón/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Imagen por Resonancia Cinemagnética , Redes Neurales de la Computación
4.
Magn Reson Med ; 85(1): 182-196, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32700791

RESUMEN

PURPOSE: Inhomogeneities of the static magnetic B0 field are a major limiting factor in cardiac MRI at ultrahigh field (≥ 7T), as they result in signal loss and image distortions. Different magnetic susceptibilities of the myocardium and surrounding tissue in combination with cardiac motion lead to strong spatio-temporal B0 -field inhomogeneities, and their homogenization (B0 shimming) is a prerequisite. Limitations of state-of-the-art shimming are described, regional B0 variations are measured, and a methodology for spherical harmonics shimming of the B0 field within the human myocardium is proposed. METHODS: The spatial B0 -field distribution in the heart was analyzed as well as temporal B0 -field variations in the myocardium over the cardiac cycle. Different shim region-of-interest selections were compared, and hardware limitations of spherical harmonics B0 shimming were evaluated by calibration-based B0 -field modeling. The role of third-order spherical harmonics terms was analyzed as well as potential benefits from cardiac phase-specific shimming. RESULTS: The strongest B0 -field inhomogeneities were observed in localized spots within the left-ventricular and right-ventricular myocardium and varied between systolic and diastolic cardiac phases. An anatomy-driven shim region-of-interest selection allowed for improved B0 -field homogeneity compared with a standard shim region-of-interest cuboid. Third-order spherical harmonics terms were demonstrated to be beneficial for shimming of these myocardial B0 -field inhomogeneities. Initial results from the in vivo implementation of a potential shim strategy were obtained. Simulated cardiac phase-specific shimming was performed, and a shim term-by-term analysis revealed periodic variations of required currents. CONCLUSION: Challenges in state-of-the-art B0 shimming of the human heart at 7 T were described. Cardiac phase-specific shimming strategies were found to be superior to vendor-supplied shimming.


Asunto(s)
Corazón , Procesamiento de Imagen Asistido por Computador , Calibración , Corazón/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética
5.
NMR Biomed ; 33(7): e4298, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32207190

RESUMEN

In this study we aimed to assess the effects of continuous formalin fixation on diffusion and relaxation metrics of the ex vivo porcine heart at 7 T. Magnetic resonance imaging was performed on eight piglet hearts using a 7 T whole body system. Hearts were measured fresh within 3 hours of cardiac arrest followed by immersion in 10% neutral buffered formalin. T2* and T2 were assessed using a gradient multi-echo and multi-echo spin echo sequence, respectively. A spin echo and a custom stimulated echo sequence were employed to assess diffusion time-dependent changes in metrics of cardiac diffusion tensor imaging. SNR was determined for b = 0 images. Scans were performed for 5 mm thick apical, midcavity and basal slices (in-plane resolution: 1 mm) and repeated 7, 15, 50, 100 and 200 days postfixation. Eigenvalues of the apparent diffusion coefficient (ADC) and fractional anisotropy (FA) decreased significantly (P < 0.05) following fixation. Relative to fresh hearts, FA values 7 and 200 days postfixation were 90% and 80%, while respective relative ADC values at those fixation stages were 78% and 92%. Statistical helix and sheetlet angle distributions as well as respective mean and median values showed no systematic influence of continuous formalin fixation. Similar to changes in the ADC, values for T2 , T2* and SNR dropped initially postfixation. Respective relative values compared with fresh hearts at day 7 were 64%, 79% and 68%, whereas continuous fixation restored T2 , T2* and SNR leading to relative values of 74%, 100%, and 81% at day 200, respectively. Relaxation parameters and diffusion metrics are significantly altered by continuous formalin fixation. The preservation of microstructure metrics following prolonged fixation is a key finding that may enable future studies of ventricular remodeling in cardiac pathologies.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Formaldehído/química , Corazón/diagnóstico por imagen , Fijación del Tejido , Animales , Relación Señal-Ruido , Marcadores de Spin , Porcinos
6.
PLoS One ; 14(3): e0213994, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30908510

RESUMEN

Purpose of this work was to assess feasibility of cardiac diffusion tensor imaging (cDTI) at 7 T in a set of healthy, unfixed, porcine hearts using various parallel imaging acceleration factors and to compare SNR and derived cDTI metrics to a reference measured at 3 T. Magnetic resonance imaging was performed on 7T and 3T whole body systems using a spin echo diffusion encoding sequence with echo planar imaging readout. Five reference (b = 0 s/mm2) images and 30 diffusion directions (b = 700 s/mm2) were acquired at both 7 T and 3 T using a GRAPPA acceleration factor R = 1. Scans at 7 T were repeated using R = 2, R = 3, and R = 4. SNR evaluation was based on 30 reference (b = 0 s/mm2) images of 30 slices of the left ventricle and cardiac DTI metrics were compared within AHA segmentation. The number of hearts scanned at 7 T and 3 T was n = 11. No statistically significant differences were found for evaluated helix angle, secondary eigenvector angle, fractional anisotropy and apparent diffusion coefficient at the different field strengths, given sufficiently high SNR and geometrically undistorted images. R≥3 was needed to reduce susceptibility induced geometric distortions to an acceptable amount. On average SNR in myocardium of the left ventricle was increased from 29±3 to 44±6 in the reference image (b = 0 s/mm2) when switching from 3 T to 7 T. Our study demonstrates that high resolution, ex vivo cDTI is feasible at 7 T using commercial hardware.


Asunto(s)
Imagen de Difusión Tensora/métodos , Corazón/anatomía & histología , Sus scrofa/anatomía & histología , Animales , Imagen de Difusión Tensora/estadística & datos numéricos , Imagen Eco-Planar/métodos , Imagen Eco-Planar/estadística & datos numéricos , Estudios de Factibilidad , Corazón/diagnóstico por imagen , Imagenología Tridimensional/métodos , Imagenología Tridimensional/estadística & datos numéricos , Técnicas In Vitro , Masculino , Modelos Animales , Modelos Cardiovasculares , Relación Señal-Ruido
7.
Magn Reson Med ; 75(3): 985-96, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25884985

RESUMEN

PURPOSE: Overhauser dynamic nuclear polarization (DNP) allows the production of liquid hyperpolarized substrate inside the MRI magnet bore as well as its administration in continuous flow mode to acquire MR images with enhanced signal-to-noise ratio. We implemented inversion recovery preparation in order to improve contrast-to-noise ratio and to quantify the overall imaging performance of Overhauser DNP-enhanced MRI. METHOD: The negative enhancement created by DNP in combination with inversion recovery (IR) preparation allows canceling selectively the signal originated from Boltzmann magnetization and visualizing only hyperpolarized fluid. The theoretical model describing gain of MR image intensity produced by steady-state continuous flow DNP hyperpolarized magnetization was established and proved experimentally. RESULTS: A precise quantification of signal originated purely from DNP hyperpolarization was achieved. A temperature effect on longitudinal relaxation had to be taken into account to fit experimental results with numerical prediction. CONCLUSION: Using properly adjusted IR preparation, the complete zeroing of thermal background magnetization was achieved, providing an essential increase of contrast-to-noise ratio of DNP-hyperpolarized water images. To quantify and optimize the steady-state conditions for MRI with continuous flow DNP, an approach similar to that incorporating transient-state thermal magnetization equilibrium in spoiled fast field echo imaging sequences can be used.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Procesamiento de Señales Asistido por Computador , Animales , Aorta/fisiología , Diseño de Equipo , Espectroscopía de Resonancia Magnética , Ratones , Modelos Teóricos , Fantasmas de Imagen , Agua
8.
Magn Reson Med ; 69(1): 229-37, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22392633

RESUMEN

The purpose of this work was to validate ventilation-weighted (VW) and perfusion-weighted (QW) Fourier decomposition (FD) magnetic resonance imaging (MRI) with hyperpolarized (3)He MRI and dynamic contrast-enhanced perfusion (DCE) MRI in a controlled animal experiment. Three healthy pigs were studied on 1.5-T MR scanner. For FD MRI, the VW and QW images were obtained by postprocessing of time-resolved lung image sets. DCE acquisitions were performed immediately after contrast agent injection. (3)He MRI data were acquired following the administration of hyperpolarized helium and nitrogen mixture. After baseline MR scans, pulmonary embolism was artificially produced. FD MRI and DCE MRI perfusion measurements were repeated. Subsequently, atelectasis and air trapping were induced, which followed with FD MRI and (3)He MRI ventilation measurements. Distributions of signal intensities in healthy and pathologic lung tissue were compared by statistical analysis. Images acquired using FD, (3)He, and DCE MRI in all animals before the interventional procedure showed homogeneous ventilation and perfusion. Functional defects were detected by all MRI techniques at identical anatomical locations. Signal intensity in VW and QW images was significantly lower in pathological than in healthy lung parenchyma. The study has shown usefulness of FD MRI as an alternative, noninvasive, and easily implementable technique for the assessment of acute changes in lung function.


Asunto(s)
Medios de Contraste , Gadolinio DTPA , Helio , Angiografía por Resonancia Magnética , Imagen por Resonancia Magnética , Relación Ventilacion-Perfusión , Animales , Análisis de Fourier , Isótopos , Pulmón/anatomía & histología , Masculino , Embolia Pulmonar/patología , Embolia Pulmonar/fisiopatología , Ventilación Pulmonar , Sus scrofa
9.
Chem Commun (Camb) ; 47(31): 8898-900, 2011 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-21748171

RESUMEN

A wet chemical approach from organometallic reactants allowed the targeted synthesis of Co@Fe(2)O(3) heterodimer and CoFe(2)O(4) ferrite nanoparticles. They display magnetic properties that are useful for magnetic MRI detection.


Asunto(s)
Cobalto/química , Compuestos Férricos/química , Nanopartículas del Metal/química , Medios de Contraste/química , Imagen por Resonancia Magnética , Magnetismo , Nanopartículas del Metal/ultraestructura
10.
J Magn Reson Imaging ; 32(4): 887-94, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-20882619

RESUMEN

PURPOSE: To protect the patient with acute respiratory distress syndrome from ventilator associated lung injury (VALI) high-frequency oscillatory ventilation (HFOV) is used. Clinical experience has proven that HFOV is an efficient therapy when conventional artificial ventilation is insufficient. However, the optimal settings of HFOV parameters, eg, tidal volumes, pressure amplitudes and frequency for maximal lung protection, and efficient gas exchange are not established unambiguously. METHODS: In this work magnetic resonance imaging (MRI) with hyperpolarized (3)He was employed to visualize the redistribution of gas within the cadaver pig lung during HFOV. The saturated slice method was used to characterize fast gas kinetics. RESULTS: The strong differences in kinetics were observed for HFOV-driven gas exchange in comparison with diffusive gas transport (apnea). The significant regional and HFOV frequency dependence was detected for washout and gas exchange within the lungs. Gas redistribution was much faster in posterior than in anterior parts of the lungs during HFOV, in contrast to minor differences with an opposite trend observed in apnea. CONCLUSION: The method shows significant potential for visualization and quantification of gas redistribution under HFOV and may help in optimization of the parameters to improve the clinical effect of HFOV for patients.


Asunto(s)
Helio/química , Pulmón/patología , Imagen por Resonancia Magnética/métodos , Oscilometría/métodos , Síndrome de Dificultad Respiratoria/complicaciones , Animales , Gases , Ventilación de Alta Frecuencia/efectos adversos , Cinética , Modelos Teóricos , Presión , Respiración Artificial/efectos adversos , Síndrome de Dificultad Respiratoria/terapia , Porcinos
11.
Magn Reson Med ; 64(5): 1478-83, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-20593369

RESUMEN

High-frequency oscillatory ventilation is looked upon as a lung-protective ventilation strategy. For a further clarification of the physical processes promoting gas transport, a visualization of gas flow and the distribution of ventilation are of considerable interest. Therefore, fluorine-19 magnetic resonance imaging of the imaging gas octafluorocyclobutane (C(4) F(8) ) during high-frequency oscillatory ventilation was performed in five healthy pigs. For that, a mutually compatible ventilation-imaging system was set up and transverse images were acquired every 5 sec using FLASH sequences on a 1.5 T scanner. Despite a drop in signal-to-noise ratio after the onset of high-frequency oscillatory ventilation, for each pig, the four experiments could be analyzed. A mean wash-out time (τ) at 5 Hz of 52.7 ± 18 sec and 125.9 ± 39 sec at 10 Hz, respectively, were found for regions of interest including the whole lung. This is in agreement with the clinical findings, in that wash-out of respiratory gases is significantly prolonged for increased high-frequency oscillatory ventilation frequencies. Our study could be a good starting-point for a further optimization of high-frequency oscillatory ventilation.


Asunto(s)
Flúor , Ventilación de Alta Frecuencia/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Intercambio Gaseoso Pulmonar/fisiología , Animales , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Porcinos
12.
Magn Reson Med ; 64(5): 1461-70, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-20597123

RESUMEN

Physiologic motion of the heart is one of the major problems of myocardial blood flow quantification using first pass perfusion-MRI method. To overcome these problems, a perfusion pulse sequence with prospective slice tracking was developed. Cardiac motion was monitored by a navigator directly positioned at heart's basis to overcome no additional underlying model calculations connecting diaphragm and cardiac motion. Additional prescans were used before the perfusion measurement to detect slice displacements caused by remaining cardiac motion between navigator and the perfusion slice readout. The pulse sequence and subsequent quantification of myocardial blood flow was tested in healthy pigs with and without prospective slice tracking under both free-breathing and breath-hold conditions. To avoid influences by residual contrast agent concentration time courses were analyzed. Median myocardial blood flow values and interquartile ranges with prospective slice tracking under free-breathing and in a breath-hold were (1.04, interquartile range = 0.58 mL/min/g) and (1.20, interquartile range = 0.59 mL/min/g), respectively. This is in agreement with published positron emission tomography values. In measurements without prospective slice tracking (1.15, interquartile range = 1.58 mL/min/g), the interquartile range is significantly (P < 0.012) larger because of residual cardiac motion. In conclusion, prospective slice tracking reduces motion-induced variations of myocardial blood flow under both during breath-hold and under conditions of free-breathing.


Asunto(s)
Algoritmos , Circulación Coronaria/fisiología , Interpretación de Imagen Asistida por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Técnicas de Imagen Sincronizada Respiratorias/métodos , Animales , Humanos , Aumento de la Imagen/métodos , Angiografía por Resonancia Magnética/instrumentación , Fantasmas de Imagen , Reproducibilidad de los Resultados , Mecánica Respiratoria , Técnicas de Imagen Sincronizada Respiratorias/instrumentación , Sensibilidad y Especificidad , Porcinos
14.
Magn Reson Med ; 62(2): 476-87, 2009 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19488992

RESUMEN

Validation of quantification of pulmonary blood flow (PBF) with dynamic, contrast-enhanced MRI is still missing. A possible reason certainly lies in difficulties based on the nonlinear dependence of signal intensity (SI) from contrast agent (CA) concentration. Both aspects were addressed in this study. Nine healthy pigs were examined by first-pass perfusion MRI using gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA) and H(2)(15)O positron emission tomography (PET) imaging. Calculations of hemodynamic parameters were based on a one-compartment model (MR) and a two-compartment model (PET). Simulations showed a significant error when assuming a linear relation between MR SI and CA dose in the arterial input function (AIF), even at low doses of 0.025 mmol/kg body weight (BW). To correct for nonlinearity, a calibration curve was calculated on the basis of the signal equation. The required accuracy of equation parameters (like longitudinal relaxation time) was evaluated. Error analysis estimates <5% over-/underestimation of the corrected SI. Comparison of PET and MR flow values yielded a significant correlation (P < 0.001) in dorsal regions where signal-to-noise ratio (SNR) was sufficient. Changes in PBF due to the correction method were significant (P < 0.001) and resulted in a better agreement: mean values (standard deviation) in units of ml/min/100 ml lung tissue were 59 (15) for PET, 112 (28) for uncorrected MRI, and 80 (21) for corrected MRI.


Asunto(s)
Artefactos , Gadolinio DTPA , Aumento de la Imagen/métodos , Angiografía por Resonancia Magnética/métodos , Imagen de Perfusión/métodos , Tomografía de Emisión de Positrones/métodos , Circulación Pulmonar/fisiología , Animales , Medios de Contraste , Radioisótopos de Oxígeno , Radiofármacos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Porcinos , Agua
SELECCIÓN DE REFERENCIAS