Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
2.
ESC Heart Fail ; 5(2): 222-232, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29235244

RESUMEN

The present update is dedicated to the evolution of the interaction between heart failure (HF) and exercise and how the scientific community has handled it. Indeed, on the one hand, HF is a leading cause of morbidity and mortality with a stable prevalence from 1998 onward varying between 6.3% and 13.3%. On the other hand, exercise is seen as a diagnostic and prognostic tool as well as a therapeutic intervention in chronic HF. More precisely, the knowledge, the clinical application, and the research interest on the mutual interactions between exercise and HF have different phases in disease progression: Before HF onset (past): exercise provides protective benefit in preventing HF (primary prevention). With HF present: exercise improvement with training provides benefits in HF (secondary prevention). The prediction of future in HF patients: exercise impairment, as a leading characteristic of HF, is used as a prognostic factor.


Asunto(s)
Terapia por Ejercicio/métodos , Ejercicio Físico/fisiología , Insuficiencia Cardíaca/rehabilitación , Insuficiencia Cardíaca/fisiopatología , Humanos , Pronóstico
3.
Int J Cardiol ; 228: 805-811, 2017 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-27888758

RESUMEN

BACKGROUND: The outcome of radiofrequency catheter ablation (RFCA) of atrial fibrillation (AF) has improved thanks to left atrium (LA) anatomy reconstruction by cardiac computed tomography (CCT). A new model-based iterative reconstruction algorithm (MBIR) provides image noise reduction achieving effective radiation dose (ED) close to chest X-ray exposure. Aim of this study was comparing RFCA procedural characteristics, AF recurrence and radiation exposure between patients in whom RFCA was guided by CCT image integration with MBIR versus a CCT standard protocol. METHODS: Three-hundred consecutive patients with drug-refractory AF were studied with CCT using MBIR (Group 1; N:150) or CCT with standard protocol (Group 2; N:150) for LA evaluation and treated by image integration-supported RFCA. Image noise, signal to noise ratio (SNR), contrast to noise ratio (CNR), RFCA procedural characteristics, rate of AF recurrence and radiation exposure were compared. RESULTS: Group 1 showed higher SNR (25.9±7.1 vs. 16.2±4.8, p<0.001) and CNR (23.3±7.1 vs. 12.2±4.2, p<0.001) and lower image noise (22.3±5.2 vs. 32.6±8.1 HU, p<0.001), fluoroscopy time (21±12 vs. 29±15min, p<0.01) and procedural duration (135±89 vs. 172±55, p<0.001). Group 1 showed a 94% reduction of ED as compared to Group 2 (CCT-ED related: 0.41±0.04 vs. 6.17±4.11mSv, p<0.001; cumulative CCT+RFCA-ED related: 21.9±17.9 vs. 36.0±24.1mSv, p<0.001) with similar rate of AF recurrence (25% vs. 29%, p=0.437). CONCLUSIONS: CCT with MBIR allows accurate reconstruction of LA anatomy in AF patients undergoing RFCA with a sub-millisievert ED and comparable success rate of RFCA as compared to a standard CCT scan protocol.


Asunto(s)
Fibrilación Atrial/diagnóstico por imagen , Ablación por Catéter , Atrios Cardíacos/diagnóstico por imagen , Venas Pulmonares/diagnóstico por imagen , Exposición a la Radiación , Tomografía Computarizada por Rayos X , Anciano , Algoritmos , Fibrilación Atrial/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Relación Señal-Ruido , Resultado del Tratamiento
4.
J Am Coll Cardiol ; 68(20): 2166-2181, 2016 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-27855806

RESUMEN

BACKGROUND: Cardiac magnetic resonance (CMR) is useful for the diagnosis of left ventricular noncompaction (LVNC). However, there are limited data regarding its prognostic value. OBJECTIVES: The goal of this study was to evaluate the prognostic relevance of CMR findings in patients with LVNC. METHODS: A total of 113 patients with an echocardiographic diagnosis of LVNC underwent CMR at 5 referral centers. CMR diagnostic criterion of LVNC (noncompacted/compacted ratio >2.3 in end-diastole) was confirmed in all patients. We performed left ventricular (LV) and right ventricular quantitative analysis and late gadolinium enhancement (LGE) assessments and analyzed the following LVNC diagnostic criteria: left ventricular noncompacted myocardial mass (LV-ncMM) >20% and >25%, total LV-ncMM index >15 g/m2, noncompacted/compacted ratio ≥3:1 ≥1 of segments 1 to 3 and 7 to 16 or ≥2:1 in at least 1 of segments 4 to 6 of the American Heart Association model. Outcome was a composite of thromboembolic events, heart failure hospitalizations, ventricular arrhythmias, and cardiac death. RESULTS: At a mean follow-up of 48 ± 24 months, cardiac events (CEs) occurred in 36 patients (16 heart failure hospitalizations, 10 ventricular arrhythmias, 5 cardiac deaths, and 5 thromboembolic events). LV dilation, impaired LV ejection fraction, and LV-ncMM >20% was significantly more frequent in patients with CEs. LV fibrosis was detected by using LGE in 11 cases. CMR predictors of CEs were LV dilation and LGE. LGE was associated with improved prediction of CEs, compared with clinical data and CMR functional parameters in all 3 models. No CEs occurred in patients without dilated cardiomyopathy and/or LGE. CONCLUSIONS: In patients with LVNC evaluated by using CMR, the degree of LV trabeculation seems to have no prognostic impact over and above LV dilation, LV systolic dysfunction, and presence of LGE.


Asunto(s)
Ventrículos Cardíacos/diagnóstico por imagen , No Compactación Aislada del Miocardio Ventricular/diagnóstico , Imagen por Resonancia Cinemagnética/métodos , Adulto , Progresión de la Enfermedad , Ecocardiografía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Prospectivos , Reproducibilidad de los Resultados , Factores de Tiempo
5.
Circ Cardiovasc Imaging ; 9(10)2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27894070

RESUMEN

BACKGROUND: Computed tomography coronary angiography (cTCA) and stress cardiac magnetic resonance (stress-CMR) are suitable tools for diagnosing obstructive coronary artery disease in symptomatic patients with previous history of revascularization. However, performance appraisal of noninvasive tests must take in account the consequent diagnostic testing, invasive procedures, clinical outcomes, radiation exposure, and cumulative costs rather than their diagnostic accuracy only. We aimed to compare an anatomic (cTCA) versus a functional (stress-CMR) strategy in symptomatic patients with previous myocardial revascularization procedures. METHODS AND RESULTS: Six hundred patients with chest pain and previous revascularization included in a prospective observational registry and evaluated by clinically indicated cTCA (n=300, mean age 68.2±9.7 years, male 255) or stress-CMR (n=300, mean age 67.6±9.7 years, male 263) were enrolled and followed-up in terms of subsequent noninvasive tests, invasive coronary angiography, revascularization procedures, cumulative effective radiation dose, major adverse cardiac events, defined as a composite end point of nonfatal myocardial infarction and cardiac death, and medical costs. The mean follow-up for cTCA and stress-CMR groups was similar (773.6±345 versus 752.8±291 days; P=0.21). Compared with stress-CMR, cTCA was associated with a higher rate of subsequent noninvasive tests (28% versus 17%; P=0.0009), invasive coronary angiography (31% versus 20%; P=0.0009), and revascularization procedures (24% versus 16%; P=0.007). Stress-CMR strategy was associated with a significant reduction of radiation exposure and cumulative costs (59% and 24%, respectively; P<0.001). Finally, patients undergoing stress-CMR showed a lower rate of major adverse cardiac events (5% versus 10%; P<0.010) and cost-effectiveness ratio (119.98±250.92 versus 218.12±298.45 Euro/y; P<0.001). CONCLUSIONS: Compared with cTCA, stress-CMR is more cost-effective in symptomatic revascularized patients.


Asunto(s)
Angiografía por Tomografía Computarizada , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Revascularización Miocárdica , Vasodilatadores/administración & dosificación , Anciano , Causas de Muerte , Angiografía por Tomografía Computarizada/economía , Angiografía Coronaria/economía , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/economía , Enfermedad de la Arteria Coronaria/fisiopatología , Vasos Coronarios/fisiopatología , Análisis Costo-Beneficio , Femenino , Costos de la Atención en Salud , Humanos , Italia , Imagen por Resonancia Magnética/economía , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Revascularización Miocárdica/efectos adversos , Revascularización Miocárdica/economía , Revascularización Miocárdica/mortalidad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Dosis de Radiación , Exposición a la Radiación , Sistema de Registros , Reproducibilidad de los Resultados , Factores de Tiempo , Resultado del Tratamiento , Vasodilatadores/economía
6.
Circ Cardiovasc Imaging ; 9(10)2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27729359

RESUMEN

BACKGROUND: The aim of this study was to determine the prognostic benefit of cardiac magnetic resonance (CMR) over transthoracic echocardiography (TTE) in ischemic cardiomyopathy and nonischemic dilated cardiomyopathy patients evaluated for primary prevention implantable cardioverter-defibrillator therapy. METHODS AND RESULTS: We enrolled 409 consecutive ischemic and dilated cardiomyopathy patients (mean age: 64±12 years; 331 men). All patients underwent TTE and CMR, and left ventricle end-diastolic volume, left ventricle end-systolic volume, and left ventricle ejection fraction (LVEF) were evaluated. In addition, late gadolinium enhancement was also assessed. All patients were followed up for major adverse cardiac events (MACE) defined as a composite end point of long runs of nonsustained ventricular tachycardia, sustained ventricular tachycardia, aborted sudden cardiac death, or sudden cardiac death. The median follow-up was 545 days. CMR showed higher left ventricle end-diastolic volume (mean difference: 43±22.5 mL), higher left ventricle end-systolic volume (mean difference: 34±20.5 mL), and lower LVEF (mean difference: -4.9±10%) as compared to TTE (P<0.01). MACE occurred in 103 (25%) patients. Patients experiencing MACE showed higher left ventricle end-diastolic volume, higher left ventricle end-systolic volume, and lower LVEF with both imaging modalities and higher late gadolinium enhancement per-patient prevalence as compared to patients without MACE. At multivariable analysis, CMR-LVEF ≤35% (hazard ratio=2.18 [1.3-3.8]) and the presence of late gadolinium enhancement (hazard ratio=2.2 [1.4-3.6]) were independently associated with MACE (P<0.01). A model based on CMR-LVEF ≤35% or CMR-LVEF ≤35% plus late gadolinium enhancement detection showed a higher performance in the prediction of MACE as compared to TTE-LVEF resulting in net reclassification improvement of 0.468 (95% confidence interval, 0.283-0.654; P<0.001) and 0.413 (95% confidence interval, 0.23-0.63; P<0.001), respectively. CONCLUSIONS: CMR provides additional prognostic stratification as compared to TTE, which may have direct impact on the indication of implantable cardioverter-defibrillator implantation.


Asunto(s)
Cardiomiopatía Dilatada/diagnóstico por imagen , Cardiomiopatía Dilatada/terapia , Desfibriladores Implantables , Ecocardiografía/métodos , Cardioversión Eléctrica/instrumentación , Imagen por Resonancia Cinemagnética , Isquemia Miocárdica/complicaciones , Prevención Primaria/instrumentación , Derivación y Consulta , Anciano , Arritmias Cardíacas/etiología , Arritmias Cardíacas/prevención & control , Cardiomiopatía Dilatada/etiología , Cardiomiopatía Dilatada/fisiopatología , Distribución de Chi-Cuadrado , Medios de Contraste/administración & dosificación , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Meglumina/administración & dosificación , Meglumina/análogos & derivados , Persona de Mediana Edad , Análisis Multivariante , Isquemia Miocárdica/diagnóstico por imagen , Isquemia Miocárdica/fisiopatología , Compuestos Organometálicos/administración & dosificación , Valor Predictivo de las Pruebas , Prevención Primaria/métodos , Modelos de Riesgos Proporcionales , Factores de Riesgo , Volumen Sistólico , Función Ventricular Izquierda
7.
J Cardiovasc Comput Tomogr ; 10(4): 322-6, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27357327

RESUMEN

BACKGROUND: Coronary CT angiography (CTA) is gaining widespread acceptance for the non-invasive evaluation of coronary arteries. However, radiation exposure and administration of iodinated contrast agents are still reasons of some concern. The 80 kV tube voltage increases the attenuation of iodine, allowing to use lower iodine concentration contrast agents for coronary CTA. OBJECTIVE: We evaluated the diagnostic accuracy of coronary CTA performed with 64-slice scanner, 80 kV tube voltage, iterative reconstruction algorithm and ultra-low concentration contrast medium to reduce iodine load and radiation dose. METHODS: We enrolled 45 patients with low body weight and indication for elective invasive coronary angiography (ICA). All patients received an 80 ml bolus of Iodixanol-270 at an infusion rate of 5 mL/s and underwent coronary CTA (80 kV and 500-550 mA) with prospective ECG-triggering. Image quality score, type of artifacts, coronary CTA evaluability, diagnostic accuracy and radiation exposure were assessed. RESULTS: Pre-test probability of CAD was low-to-intermediate (48%). Accordingly, the prevalence of obstructive CAD was 47% (21 out of 45 patients). Most (93%) of the patients were pre-treated with intravenous metoprolol before scanning and achieved a heart rate suitable for prospective ECG-triggering coronary CTA (53 ± 3 bpm). The mean effective dose and iodine load were 1.1 ± 0.4 mSv and 21.6 gI, respectively. We rated 443 out of 720 coronary segments as being of excellent image quality. In a segment-based model, coronary evaluability (number of coronary segments evaluable/total number of coronary segments), was 97% (699/720 segments). In a segment-based analysis, sensitivity, specificity, positive predictive value, negative predictive value and accuracy for >50% coronary stenosis identification vs. ICA were 89%, 99%, 89%, 99% and 99%, respectively. In a patient-based analysis, sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 94%, 89%, 83%, 96% and 91%, respectively. CONCLUSIONS: In patients with low body weight, image quality and diagnostic accuracy of ultra-low radiation dose and low-iodine load coronary CTA are good and similar to values reported in the literature for standard tube voltage and iodine load protocols.


Asunto(s)
Peso Corporal , Angiografía por Tomografía Computarizada/métodos , Medios de Contraste/administración & dosificación , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Tomografía Computarizada Multidetector/métodos , Dosis de Radiación , Exposición a la Radiación/prevención & control , Delgadez/complicaciones , Ácidos Triyodobenzoicos/administración & dosificación , Anciano , Algoritmos , Angiografía por Tomografía Computarizada/efectos adversos , Medios de Contraste/efectos adversos , Angiografía Coronaria/efectos adversos , Enfermedad de la Arteria Coronaria/complicaciones , Estudios de Factibilidad , Femenino , Humanos , Infusiones Intravenosas , Masculino , Persona de Mediana Edad , Tomografía Computarizada Multidetector/efectos adversos , Valor Predictivo de las Pruebas , Exposición a la Radiación/efectos adversos , Interpretación de Imagen Radiográfica Asistida por Computador , Reproducibilidad de los Resultados , Factores de Riesgo , Delgadez/diagnóstico , Ácidos Triyodobenzoicos/efectos adversos
8.
Eur Radiol ; 26(1): 147-56, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25953001

RESUMEN

OBJECTIVES: The aim of this study was to evaluate the impact of a novel intra-cycle motion correction algorithm (MCA) on overall evaluability and diagnostic accuracy of cardiac computed tomography coronary angiography (CCT). METHODS: From a cohort of 900 consecutive patients referred for CCT for suspected coronary artery disease (CAD), we enrolled 160 (18 %) patients (mean age 65.3 ± 11.7 years, 101 male) with at least one coronary segment classified as non-evaluable for motion artefacts. The CCT data sets were evaluated using a standard reconstruction algorithm (SRA) and MCA and compared in terms of subjective image quality, evaluability and diagnostic accuracy. RESULTS: The mean heart rate during the examination was 68.3 ± 9.4 bpm. The MCA showed a higher Likert score (3.1 ± 0.9 vs. 2.5 ± 1.1, p < 0.001) and evaluability (94%vs.79 %, p < 0.001) than the SRA. In a 45-patient subgroup studied by clinically indicated invasive coronary angiography, specificity, positive predictive value and accuracy were higher in MCA vs. SRA in segment-based and vessel-based models, respectively (87%vs.73 %, 50%vs.34 %, 85%vs.73 %, p < 0.001 and 62%vs.28 %, 66%vs.51 % and 75%vs.57 %, p < 0.001). In a patient-based model, MCA showed higher accuracy vs. SCA (93%vs.76 %, p < 0.05). CONCLUSIONS: MCA can significantly improve subjective image quality, overall evaluability and diagnostic accuracy of CCT. KEY POINTS: Cardiac computed tomographic coronary angiography (CCT) allows non-invasive evaluation of coronary arteries. Intra-cycle motion correction algorithm (MCA) allows for compensation of coronary motion. An MCA improves image quality, CCT evaluability and diagnostic accuracy.


Asunto(s)
Algoritmos , Artefactos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Anciano , Femenino , Humanos , Masculino , Movimiento (Física) , Reproducibilidad de los Resultados
9.
Eur Radiol ; 26(7): 2155-65, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26515549

RESUMEN

OBJECTIVES: Dipyridamole stress cardiac magnetic resonance (CMR) evaluates the key phases (perfusion and wall motion) of the ischemic cascade. We sought to determine the prognostic value of dipyridamole stress-CMR in consecutive patients symptomatic for chest pain. METHODS: Seven hundred and ninety-three consecutive patients symptomatic for chest pain underwent dipyridamole stress-CMR and were followed up for 810 ± 665 days. Patients were classified in group 1 (no- reversible ischemia), group 2 (stress perfusion defect alone), and group 3 [stress perfusion defect plus abnormal wall motion (AWM)]. End points were "all cardiac events" (myocardial infarction, cardiac death and revascularization) and "hard cardiac events" (all cardiac events excluding revascularization). RESULTS: One hundred and ninety-five (24 %) all cardiac events and 53 (7 %) hard cardiac events were observed. All and hard cardiac event rates in groups 1, 2, and 3 were 11 %, 49 %, 69 % and 4 %, 8 %, 21 %, respectively, with a higher rate in group 2 vs. group 1 (p<0.01) and group 3 vs. groups 1 and 2 (p<0.01). Multivariate analysis showed the presence of late gadolinium enhancement and stress perfusion defect plus AWM as independent predictors of all and hard cardiac events. CONCLUSIONS: Dipyridamole stress-CMR improves prognostic stratification of patients through differentiation between the different components of the ischemic cascade. KEY POINTS: • Dipyridamole stress cardiac magnetic resonance helps to assess coronary artery disease. • Novel technique to study the key phases of myocardial ischemia. • Combined assessment of perfusion and motion defects. • Dipyridamole stress imaging has additional value for predicting cardiac events.


Asunto(s)
Enfermedades Cardiovasculares/mortalidad , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Infarto del Miocardio/epidemiología , Revascularización Miocárdica/estadística & datos numéricos , Anciano , Dolor en el Pecho/etiología , Medios de Contraste , Dipiridamol , Prueba de Esfuerzo , Femenino , Estudios de Seguimiento , Gadolinio , Humanos , Imagen por Resonancia Magnética , Imagen por Resonancia Cinemagnética , Masculino , Persona de Mediana Edad , Análisis Multivariante , Imagen de Perfusión Miocárdica , Pronóstico , Vasodilatadores
10.
Int J Cardiol ; 203: 1067-72, 2016 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-26638056

RESUMEN

BACKGROUND: The Metabolic Exercise test data combined with Cardiac and Kidney Indexes (MECKI) score is a prognostic model to identify heart failure (HF) patients at risk for cardiovascular mortality (CVM) and urgent heart transplantation (uHT) based on 6 routine clinical parameters: hemoglobin, sodium, kidney function by the Modification of Diet in Renal Disease (MDRD) equation, left ventricle ejection fraction (LVEF), percentage of predicted peak oxygen consumption (VO2) and VE/VCO2 slope. OBJECTIVES: MECKI score must be generalizable to be considered useful: therefore, its performance was validated in a new sequence of HF patients. METHODS: Both the development (MECKI-D) and the validation (MECKI-V) cohorts were composed of consecutive HF patients with LVEF <40% able to perform a symptom-limited cardiopulmonary exercise testing. The CVM or uHT rates were analyzed at one, two and three years in both cohorts: all patients with a censoring time shorter than the scheduled follow-up were excluded, while those with events occurring after 1, 2 and 3 years were considered as censored. RESULTS: MECKI-D and MECKI-V consisted of 2009 and 992 patients, respectively. MECKI-V patients had a higher LVEF, higher peak VO2 and lower VE/VCO2 slope, higher prescription of beta-blockers and device therapy: after the 3-year follow-up, CVM or uHT occurred in 206 (18%) MECKI-D and 44 (13%) MECKI-V patients (p<0.000), respectively. MECKI-V AUC values at one, two and three years were 0.81 ± 0.04, 0.76 ± 0.04, and 0.80 ± 0.03, respectively, not significantly different from MECKI-D. CONCLUSIONS: MECKI score preserves its predictive ability in a HF population at a lower risk.


Asunto(s)
Prueba de Esfuerzo/métodos , Insuficiencia Cardíaca/diagnóstico , Trasplante de Corazón/métodos , Anciano , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/metabolismo , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/cirugía , Pruebas de Función Cardíaca/métodos , Pruebas de Función Cardíaca/normas , Trasplante de Corazón/normas , Humanos , Pruebas de Función Renal/métodos , Pruebas de Función Renal/normas , Masculino , Persona de Mediana Edad , Consumo de Oxígeno/fisiología , Valor Predictivo de las Pruebas , Pronóstico , Índice de Severidad de la Enfermedad , Volumen Sistólico/fisiología
11.
Eur Heart J Cardiovasc Imaging ; 16(10): 1093-100, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25762564

RESUMEN

AIMS: Motion artefacts due to high or irregular heart rate (HR) are common limitations of coronary computed tomography (CT) angiography (CCTA). The aim of the study was to evaluate the impact of a new motion-correction (MC) algorithm used in conjunction with low-dose prospective ECG-triggering CCTA on motion artefacts, image quality, and coronary assessability. METHODS AND RESULTS: Among 380 patients undergoing CCTA for suspected CAD, we selected 120 patients with pre-scanning HR >70 bpm or HR variability (HRv) >10 bpm during scanning irrespective of pre-scanning HR or both conditions. In patients with pre-scanning HR <65 or ≥65 bpm, prospective ECG triggering with padding of 80 ms (58 cases) or padding of 200 ms (62 cases) was used, respectively. Mean pre-scanning HR and HRv were 70 ± 7 and 10.9 ± 4 bpm, respectively. Overall, the mean effective dose was 3.4 ± 1.3 mSv, while a lower dose (2.4 ± 0.9 mSv) was measured for padding of 80 ms. In a segment-based analysis, coronary assessability was significantly higher (P < 0.0001) with MC (97%) when compared with standard (STD) reconstruction (81%) due to a significant reduction (P < 0.0001) in severe artefacts (54 vs. 356 cases, respectively). An artefact sub-analysis showed significantly lower number of motion artefacts and artefacts related to chest movement with MC (16 and 4 cases) than with STD reconstruction (286 and 24 cases, P < 0.0001 and P < 0.05, respectively). The number of coronary segments ranked among those of excellent image quality was significantly higher with MC (P < 0.001). CONCLUSIONS: The MC algorithm improves CCTA image quality and coronary assessability in patients with high HR and HRv, despite low radiation dose.


Asunto(s)
Algoritmos , Artefactos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Frecuencia Cardíaca/fisiología , Tomografía Computarizada por Rayos X/métodos , Técnicas de Imagen Sincronizada Cardíacas/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Movimiento (Física) , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador
13.
Int J Cardiol ; 179: 114-21, 2015 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-25464427

RESUMEN

BACKGROUND: The outcome of radiofrequency catheter ablation (RFCA) has been improved by the pivotal role of cardiovascular imaging such as cardiac computed tomography (CCT) or cardiac magnetic resonance (CMR) for the characterization of left atrium (LA) anatomy before RFCA. The aim of this study is to compare the procedural characteristics, overall radiation exposure and clinical outcomes between RFCA guided by image integration with CCT versus CMR. METHODS: Four-hundred patients with drug-refractory paroxysmal or persistent AF referred to RCFA were matched with the propensity score matching analysis to CCT (n: 200) or CMR (n: 200) for evaluation of LA before RFCA procedure. Left atrium diameter, left atrium volume, variant of pulmonary veins' anatomy, pulmonary veins' ostial dimensions, procedural characteristics, overall radiation exposure and rate of AF recurrence after RFCA were measured and compared between the two groups. RESULTS: The 2 groups were homogeneous with similar follow-up (557 ± 302 vs. 523 ± 265 days, respectively, p:0.24). The CCT group showed higher LA volume vs. CMR group (117 ± 46 vs. 101 ± 40 mL, p<0.001). No differences were observed regarding procedural characteristics. AF recurrence at follow-up was similar (29% vs. 26%, p:0.5) despite a higher radiation exposure in the CCT group vs. CMR group (40.4 ± 23.7 mSv vs. 32.8 ± 23.5 mSv, p<0.005). LA volume detected by CMR was the most robust independent predictor of AF recurrence at multivariate analysis [(HR: 1.08 (1.01-1.15), p: 0.02]. CONCLUSIONS: CCT and CMR provide similar information before RFCA. However, RFCA CMR-guided is associated with a lower overall cumulative radiation despite similar outcome in comparison with CCT-guided RFCA.


Asunto(s)
Fibrilación Atrial/patología , Fibrilación Atrial/cirugía , Ablación por Catéter , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos , Técnicas de Imagen Sincronizada Cardíacas , Medios de Contraste , Ecocardiografía Transesofágica , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Yopamidol/análogos & derivados , Masculino , Meglumina/análogos & derivados , Persona de Mediana Edad , Compuestos Organometálicos , Puntaje de Propensión
14.
Am Heart J ; 168(3): 332-9, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25173545

RESUMEN

BACKGROUND: Multidetector computed tomography (MDCT) provides detailed assessment of valve annulus and iliofemoral vessels in transcatheter aortic valve replacement (TAVR) patients. However, data on diagnostic performance of MDCT coronary angiography (MDCT-CA) are scarce. The aim of the study is to assess diagnostic performance of MDCT for coronary artery evaluation before TAVR. METHODS: A total of 325 consecutive patients (234 without previous myocardial revascularization, 49 with previous coronary stenting, and 42 with previous coronary artery bypass graft [CABG]) underwent invasive coronary angiography and MDCT before TAVR. MDCT-CA was performed using the same data set dedicated to standard MDCT aortic annulus evaluation. Multidetector computed tomography-CA evaluability and diagnostic accuracy in comparison with invasive coronary angiography as criterion standard were assessed. RESULTS: The MDCT-CA evaluability of native coronaries was 95.6%. The leading cause of unevaluability was beam-hardening artifact due to coronary calcifications. In a segment-based analysis, MDCT-CA showed sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy for detecting ≥50% stenosis of 91%, 99.2%, 83.4%, 99.6% and 98.8%, respectively. The MDCT-CA evaluability of coronary stents was 82.1%. In a segment-based analysis, MDCT-CA showed sensitivity, specificity, PPV, NPV, and accuracy for detecting ≥50% in-stent restenosis of 94.1%, 86.7%, 66.7%, 98.1%, and 88.3%, respectively. All CABGs were correctly assessed by MDCT-CA. In a patient-based analysis, MDCT-CA showed sensitivity, specificity, PPV, NPV, and accuracy of 89.7%, 90.8%, 80.6%, 95.4%, and 90.5%, respectively. CONCLUSIONS: Multidetector computed tomography-CA allows to correctly rule out the presence of significant native coronary artery stenosis, significant in-stent restenosis, and CABG disease in patients referred for TAVR.


Asunto(s)
Válvula Aórtica , Angiografía Coronaria/métodos , Vasos Coronarios/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Comorbilidad , Puente de Arteria Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/epidemiología , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/epidemiología , Femenino , Enfermedades de las Válvulas Cardíacas/epidemiología , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Tomografía Computarizada Multidetector , Valor Predictivo de las Pruebas , Dosis de Radiación , Sensibilidad y Especificidad , Stents
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA