Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
J Oral Maxillofac Res ; 15(1): e4, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38812952

RESUMEN

Objectives: The purpose of this comparative study in vitro was to evaluate the effect of organic and inorganic nanoparticles on colour stability, tear strength and hardness of maxillofacial silicone elastomer at baseline and when subjected to outdoor weathering for 6 months. Material and Methods: A total of 240 specimens were fabricated using M511 platinum silicone which were divided into total 4 groups (n = 60) based on the type of nanoparticles (control, polytetrafuoroethylene [PTFE], titanium dioxide [TiO2], zinc oxide [ZnO]) added and each group was further divided into 3 subgroups (n = 20) for colour, tear strength (TS) and hardness (H) testing. The tests were conducted and data was obtained both before and after outdoor weathering of 6 months. Results: Minimum colour change after weathering was observed in PTFE group (∆E = 2.23). TiO2 group showed maximum TS (12.01 N/mm) followed by PTFE group (10.85 N/mm) before weathering. After weathering, maximum TS was shown by TiO2 group (12.9 N/mm) and PTFE group (12.54 N/mm). TiO2 group showed maximum hardness (24.15 shore A) before weathering and PTFE group showed maximum hardness (33.43 shore A) after weathering. Conclusions: Within the limitations of this study, it can be concluded that the addition of polytetrafuoroethylene nanoparticles to the polymer enhances both the optical as well as mechanical properties and can be considered favourable for the extended life of the prosthesis.

2.
Indian J Microbiol ; 61(2): 203-211, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33927461

RESUMEN

Despite recent improvement in implant survival rates, there remains a significant demand for enhancing the long-term clinical efficacy of titanium (Ti) implants, particularly for the prevention of peri-implantitis. Bioactive substances such as antimicrobial peptides are emerging as effective alternatives for contemporary antimicrobial agents used in dental health care. Current research work was focused to use laterosporulins that are non-haemolytic cationic antimicrobial peptides from Brevibacillus spp. for coating commercially available Ti discs. The coated Ti surfaces were evaluated in vitro for biofilm formation by two dental plaque isolates Streptococcus gordonii strain DIGK25 and S. mutans strain DIGK119 as representatives of commensal and pathogenic streptococci respectively. The biofilm inhibition was ascertained with replicated experiments on hydroxyapatite discs and confirmed by florescence microscopy. The laterosporulin coated Ti discs showed significantly reduced biofilm formation by oral streptococci and displayed promising potential to enhance the antibacterial surface properties. Such improvised Ti surfaces may curb the menace of oral streptococcal biofilm formation on dental implants and the associated implant failures.

3.
J Int Soc Prev Community Dent ; 7(Suppl 2): S99-S106, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29184836

RESUMEN

AIMS AND OBJECTIVE: Denture fractures are a common problem in clinical practice. Despite the use of different reinforcement materials (metal wires, metal plates, and various types of fibers) for denture repairs, recurrent fractures are still common. The purpose of this study was to compare the maximum flexural loads of the heat-polymerized denture base resin when repaired with autopolymerizing resin reinforced with relatively smaller diameter metal wires and glass fibers, before and after thermocycling. MATERIALS AND METHODS: Heat polymerized rectangular specimens were fabricated and repaired with autopolymerized resin and different reinforcement materials. Stainless steel wires, coaxial wires, beta-titanium wires, and glass fibers were used as reinforcement materials. Metal wires were sandblasted before placing in the center of the specimen along with autopolymerizing resin. Control specimens were repaired without any reinforcements. Intact heat- and self-cure specimens were also prepared for comparison. Half of the specimens of each group were subjected to thermocycle stressing (5°C and 55°C, 30 s dwell time) for 2000 cycles. All the specimens, nonthermocycled as well as thermocycled, were then tested for flexural strength by using 3 point flexural test in Lloyd's Universal testing machine at 5 mm/min crosshead speed. The maximum flexural loads (N) for each specimen were recorded. The readings, thus obtained, were subjected to statistical analysis using two-way ANOVA and Tukey's multiple comparison test. RESULTS: The metal wire reinforcements increased the flexural strength of repaired specimens, whereas, glass fiber reinforcement produced slightly lower flexural strength when compared to those of control specimens, i.e., repair without any reinforcement. The highest flexural strength was demonstrated by specimens repaired with coaxial wire reinforcements (50.01 and 43.77 N before and after thermocycling, respectively). The increase in flexural strength with the use of stainless steel wire (45.12 and 41.56 N) and beta-titanium wire reinforcements (45.54 and 42.61N) was insignificant. CONCLUSIONS: Coaxial wire reinforcement produced significantly higher flexural loads than control. Increase in strength with stainless steel wire and beta-titanium wire was insignificant, whereas glass fiber reinforcement reduced the strength.

4.
J Clin Diagn Res ; 8(6): ZD04-6, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25121066

RESUMEN

Implants have been designed to rehabilitate edentulous patients with fixed prosthesis or implant supported overdentures. Implant-supported single crowns and fixed partial dentures have become successful treatment alternatives to removable and fixed partial dentures. However, it is common to have clinical situations which make it impossible to use conventional as well as implant supported fixed partial dentures. The implant supported removable partial dentures can be a treatment modality that offers the multitude of benefits of implant-based therapy-biologic, biomechanical, social, and psychological to such patients. The aim of this article is to present a case report describing the fabrication and advantages of removable partial denture supported by teeth and implants for a patient with long edentulous span. The patient was satisfied with his dentures in terms of function and aesthetics. Regular follow-up visits over a period of three years revealed that the periodontal condition of remaining natural dentition and peri-implant conditions were stable. There was no evidence of excessive residual ridge resorption or mobility of the teeth, nor were any visible changes in the bone levels of the natural teeth or implants noted on radiographs.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA