Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
Rev Sci Instrum ; 89(10): 10B109, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30399682

RESUMEN

Great advancements in modern field-reversed configuration (FRC) experiments motivated the development of a 14-chord three-wave far infrared (FIR) laser interferometry and polarimetry diagnostic system, which can provide simultaneous high temporal resolution measurements of density and Faraday rotation profiles with high accuracy. The unique challenges facing FIR diagnostics in high beta FRC plasmas are the extremely small (<0.5°) Faraday rotation angles, and severe laser beam refraction effects due to high density gradient and choice of long wavelength. The diagnostic system design and development are described with methods to overcome the challenges, and initial experimental data are also presented.

2.
Rev Sci Instrum ; 87(11): 11E125, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910420

RESUMEN

A high sensitivity multi-channel far infrared laser diagnostics with switchable interferometry and polarimetry operation modes for the advanced neutral beam-driven C-2U field-reversed configuration (FRC) plasmas is described. The interferometer achieved superior resolution of 1 × 1016 m-2 at >1.5 MHz bandwidth, illustrated by measurement of small amplitude high frequency fluctuations. The polarimetry achieved 0.04° instrument resolution and 0.1° actual resolution in the challenging high density gradient environment with >0.5 MHz bandwidth, making it suitable for weak internal magnetic field measurements in the C-2U plasmas, where the maximum Faraday rotation angle is less than 1°. The polarimetry resolution data is analyzed, and high resolution Faraday rotation data in C-2U is presented together with direct evidences of field reversal in FRC magnetic structure obtained for the first time by a non-perturbative method.

3.
Chem Senses ; 37(6): 553-66, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22473924

RESUMEN

Olfaction begins when an animal draws odorant-laden air into its nasal cavity by sniffing, thus transporting odorant molecules from the external environment to olfactory receptor neurons (ORNs) in the sensory region of the nose. In the dog and other macrosmatic mammals, ORNs are relegated to a recess in the rear of the nasal cavity that is comprised of a labyrinth of scroll-like airways. Evidence from recent studies suggests that nasal airflow patterns enhance olfactory sensitivity by efficiently delivering odorant molecules to the olfactory recess. Here, we simulate odorant transport and deposition during steady inspiration in an anatomically correct reconstructed model of the canine nasal cavity. Our simulations show that highly soluble odorants are deposited in the front of the olfactory recess along the dorsal meatus and nasal septum, whereas moderately soluble and insoluble odorants are more uniformly deposited throughout the entire olfactory recess. These results demonstrate that odorant deposition patterns correspond with the anatomical organization of ORNs in the olfactory recess. Specifically, ORNs that are sensitive to a particular class of odorants are located in regions where that class of odorants is deposited. The correlation of odorant deposition patterns with the anatomical organization of ORNs may partially explain macrosmia in the dog and other keen-scented species.


Asunto(s)
Simulación por Computador , Cavidad Nasal/metabolismo , Odorantes , Olfato/fisiología , Movimientos del Aire , Animales , Transporte Biológico , Perros , Odorantes/análisis
4.
J Hosp Infect ; 77(3): 213-22, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21194796

RESUMEN

With concerns about the potential for the aerosol and airborne transmission of infectious agents, particularly influenza, more attention is being focused on the effectiveness of infection control procedures to prevent hospital-acquired infections by this route. More recently a number of different techniques have been applied to examine the temporal-spatial information about the airflow patterns and the movement of related, suspended material within this air in a hospital setting. Closer collaboration with engineers has allowed clinical microbiologists, virologists and infection control teams to assess the effectiveness of hospital isolation and ventilation facilities. The characteristics of human respiratory activities have also been investigated using some familiar engineering techniques. Such studies aim to enhance the effectiveness of such preventive measures and have included experiments with human-like mannequins using various tracer gas/particle techniques, real human volunteers with real-time non-invasive Schlieren imaging, numerical modelling using computational fluid dynamics, and small scale physical analogues with water. This article outlines each of these techniques in a non-technical manner, suitable for a clinical readership without specialist airflow or engineering knowledge.


Asunto(s)
Aerosoles , Movimientos del Aire , Infección Hospitalaria/prevención & control , Espiración , Control de Infecciones/métodos , Microbiología del Aire , Contaminación del Aire Interior , Control de Enfermedades Transmisibles , Infección Hospitalaria/transmisión , Humanos , Hidrodinámica , Ventilación
5.
J Forensic Sci ; 46(6): 1324-31, 2001 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-11714142

RESUMEN

An experimental study of the natural sampling of trace signals from explosives concealed upon the human body was performed by taking proper account of the thermal behavior of the air surrounding the human body and the particles therein. Experiments were conducted in a dispersal chamber to identify variables affecting the detectibility of concealed RDX and TNT patches. Movement by human volunteers was found to enhance the available explosive trace signal above a baseline level. Clothing blocked some of this movement-generated trace signal. The detected signal levels were also found to vary significantly from volunteer to volunteer, indicating that human variability is an issue in explosive trace detection. Further, under the conditions studied here, the detectibility of RDX and TNT was dependent upon the efficient sampling of contaminated particulate matter, not the vapor phase. The present results are now being applied to the design of a practical, nonintrusive trace detection portal for aviation security screening and related applications.


Asunto(s)
Temperatura Corporal , Explosiones/prevención & control , Triazinas/análisis , Trinitrotolueno/análisis , Aire/análisis , Humanos , Terrorismo/prevención & control , Termografía/métodos , Triazinas/química , Trinitrotolueno/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA