Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros




Base de datos
Asunto de la revista
Intervalo de año de publicación
2.
Pediatr Pulmonol ; 58(12): 3416-3427, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37701973

RESUMEN

INTRODUCTION: Outpatient monitoring of children using invasive home mechanical ventilation (IHMV) is recommended, but access to care can be difficult. This study tested if remote (home-based) data collection was feasible and acceptable in chronic IHMV management. METHODS: A codesign study was conducted with an IHMV program, home nurses, and English- and Spanish-speaking parent-guardians of children using IHMV (0-17 years; n = 19). After prototyping, parents used a remote patient monitoring (RPM) bundle to collect patient heart rate, respiratory rate (RR), oxygen saturation, end-tidal carbon dioxide (EtCO2 ), and ventilator pressure/volume over 8 weeks. User feedback was analyzed using qualitative methods and the System Usability Scale (SUS). Expected marginal mean differences within patient measures when awake, asleep, or after a break were calculated using mixed effects models. RESULTS: Patients were a median 2.9 years old and 11 (58%) took breaks off the ventilator. RPM data were entered on a mean of 83.7% (SD ± 29.1%) weeks. SUS scores were 84.8 (SD ± 10.5) for nurses and 91.8 (SD ± 10.1) for parents. Over 90% of parents agreed/strongly agreed that RPM data collection was feasible and relevant to their child's care. Within-patient comparisons revealed that EtCO2 (break-vs-asleep 2.55 mmHg, d = 0.79 [0.42-1.15], p < .001; awake-vs-break 1.48, d = -0.49 [0.13-0.84], p = .02) and RR (break-vs-asleep 16.14, d = 2.12 [1.71-2.53], p < .001; awake-vs-break 3.44, d = 0.45 [0.10-0.04], p = .03) were significantly higher during ventilator breaks. CONCLUSIONS: RPM data collection in children with IHMV was feasible, acceptable, and captured clinically meaningful vital sign changes during ventilator breaks, supporting the clinical utility of RPM in IHMV management.


Asunto(s)
Servicios de Atención de Salud a Domicilio , Respiración Artificial , Humanos , Niño , Preescolar , Respiración Artificial/métodos , Dióxido de Carbono , Ventiladores Mecánicos , Monitoreo Fisiológico/métodos
3.
Pediatr Pulmonol ; 57(11): 2735-2744, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35959530

RESUMEN

BACKGROUND: Carbon dioxide concentration trending is used in chronic management of children with invasive home mechanical ventilation (HMV) in clinical settings, but options for end-tidal carbon dioxide (EtCO2 ) monitoring at home are limited. We hypothesized that a palm-sized, portable endotracheal capnograph (PEC) that measures EtCO2 could be adapted for in-home use in children with HMV. METHODS: We evaluated the internal consistency of the PEC by calculating an intraclass correlation coefficient of three back-to-back breaths by children (0-17 years) at baseline health in the clinic. Pearson's correlation was calculated for PEC EtCO2 values with concurrent mean values of in-clinic EtCO2 and transcutaneous CO2 (TCM) capnometers. The Bland-Altman test determined their level of agreement. Qualitative interviews and surveys assessed usability and acceptability by family-caregivers at home. RESULTS: CO2 values were collected in awake children in varied activity levels and positions (N = 30). The intraclass correlation coefficient for the PEC was 0.95 (p < 0.05). The correlation between the PEC and in-clinic EtCO2 device was 0.85 with a mean difference of -3.8 mmHg and precision of ±1.1 mmHg. The correlation between the PEC and the clinic TCM device was 0.92 with a mean difference of 0.2 mmHg and precision of ±1.0. Family-caregivers (N = 10) trialed the PEC at home; all were able to obtain measurements at home while children were awake and sometimes asleep. CONCLUSIONS: A portable, noninvasive device for measuring EtCO2 was feasible and acceptable, with values that trend similarly to currently in-practice, outpatient models. These devices may facilitate monitoring of EtCO2 at home in children with invasive HMV.


Asunto(s)
Dióxido de Carbono , Respiración Artificial , Análisis de los Gases de la Sangre , Capnografía , Niño , Humanos
5.
J Clin Microbiol ; 52(6): 2242-4, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24648553

RESUMEN

We describe the clinical course of four patients who had Trichosporon mycotoxinivorans recovered from multiple sputum cultures over time with various clinical consequences but no fatalities. We also report successful rapid identification of this organism using matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry.


Asunto(s)
Fibrosis Quística/complicaciones , Trichosporon/aislamiento & purificación , Tricosporonosis/diagnóstico , Tricosporonosis/patología , Adolescente , Técnicas Bacteriológicas/métodos , Niño , Femenino , Humanos , Masculino , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Esputo/microbiología , Factores de Tiempo , Tricosporonosis/microbiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA